• 제목/요약/키워드: Cubic building

검색결과 41건 처리시간 0.025초

Estimation of Users' Waiting Cost at Container Terminals in Northern Vietnam

  • Duc, Nguyen Minh;Kim, Sung-June;Jeong, Jung-Sik
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2017년도 추계학술대회
    • /
    • pp.27-29
    • /
    • 2017
  • Container terminals in Northern Vietnam have recorded an impressive development in recent years. This development, however, also raises a fierce competition among local container terminals to attract customers. Beside the handling charges, the vessels' waiting cost is also an important factor that drive the opinion of users in choosing appropriate terminal. This research plans to estimate the waiting cost in different container terminals in Northern Vietnam by building regression equation that describe the relationship between the rate of throughput/capacity and waiting cost/TEU. Queuing theory with the application of Poisson distibution is used to estimate the waiting time of arrival vessels and uncertainty theory is applied to estimate the vessel's daily expenses. Previous studies suggested two different formation of the equation and according to the research results, cubic equation is more suitable in the given case. The research results are also useful for further research which require calculation of waiting cost per TEU in each container terminal in Northern Vietnam.

  • PDF

월터 그로피우스의 건축선언과 작품특성에 관한 연구 (A Study on the Architectural Manifesto and Design Works Characteristics of Walter Gropius)

  • 이용재
    • 한국실내디자인학회논문집
    • /
    • 제41호
    • /
    • pp.29-35
    • /
    • 2003
  • The purpose of this study is to analyze the architectural manifesto and design works characteristics of Walter Gropius. He was the director of Weimar Bauhaus that one of the advanced artificial movements in the early modern period. The almost of the early modern movements was related to the radical ideology and the manifesto. Especially Bauhaus originated from manifesto of artists teaching group with architect Walter Gropius. Therefore, the category of the study pitch upon Bauhaus architectural manifesto - Bauhaus Manifesto and Programme(1919) - and the representative works of Walter Gropius - Fagus Factory(1911-14), Dessau Bauhaus Building(1925-26), Siedlung Berlin-Siemensstadt(1929-30) and Harvard Graduate Center(1949). The conclusions of the study as per the above mentioned pill pose are the dynamic integration by non-symmetry in cubic form (formal characteristics) and organic continuity by reciprocality in transparent space (spatial characteristics).

화재 발생시 연기 거동에 대한 수치해석적 연구 - 아트리움 공간을 중심으로 - (A Numerical Study of Smoke Movement by Fire In Atrium Space)

  • 노재성;유홍선;정연태
    • 한국안전학회지
    • /
    • 제13권1호
    • /
    • pp.70-76
    • /
    • 1998
  • The smoke filling process for the atrium space containing a fire source is simulated using two types of deterministic fire models : Zone model and Field model. The zone model used is the CFAST(version 1.6) model developed at the Building and Fire Research Laboratories, NIST in the USA. The field model is a self-developed fire field model based on Computational Fluid Dynamics(CFD) theories. This article is focused on finding out the smoke movement and temperature distribution in atrium space which is cubic in shape. A computational procedure for predicting velocity and temperature distribution in fire-induced flow is based on the solution, in finite volume method and non-staggered grid system, of 3-dimensional equations for the conservation of mass, momentum, energy, species and so forth. The fire model i. e. Zone model and Field model predicted similar results for the clear height and the smoke layer temperature.

  • PDF

A simple mathematical model for static analysis of tall buildings with two outrigger-belt truss systems

  • Rahgozar, Reza;Ahmadi, Ali Reza;Hosseini, Omid;Malekinejad, Mohsen
    • Structural Engineering and Mechanics
    • /
    • 제40권1호
    • /
    • pp.65-84
    • /
    • 2011
  • In this paper a simple mathematical model for approximate static analysis of combined system of framed tube, shear core and two outrigger-belt truss structures subjected to lateral loads is presented. In the proposed methodology, framed tube is modeled as a cantilevered beam with a box section and interaction between shear core and outrigger-belt truss system with framed tube is modeled using torsional springs placed at location of outrigger-belt truss; these torsional springs act in a direction opposite to rotation generated by lateral loads. The effect of shear lag on axial deformation in flange is quadratic and in web it is a cubic function of geometry. Here the total energy of the combined system is minimized with respect to lateral deflection and rotation in plane section. Solution of the resulting equilibrium equations yields the unknown coefficients of shear lag along with the stress and displacement distributions. The results of a numerical example, 50 storey building subjected to three different types of lateral loading obtained from SAP2000 are compared to those of the proposed method and the differences are found to be reasonable. The proposed method can be used during the preliminary design stages of a tall building and can provide a better understanding of the effects of various parameters on the overall structural behavior.

정양사(正陽寺) 약사전의 건축사적 변천 - 금강산 기행문을 중심으로 - (A Study on the Architectural Transformation of the Hall of Bhaisajyaguru(Healing) Budda(藥師殿) in Chung Yang Temple(正陽寺) -from the main source of the travelogues on Mt. Kumgang. -)

  • 강병희
    • 건축역사연구
    • /
    • 제12권3호
    • /
    • pp.163-179
    • /
    • 2003
  • The records of about 60 travel essays of the Hall of Bhaisajyaguru(Healing) Budda which was built in Chung Yang Temple passed down since 1525. The chronological change of that Hall architecture according to each period was traced upon. The building structure of the Hall of Bhaisajyaguru Budda which has a roundabout way, and 6 pillars inside, sometimes each 6 pillars inside and outside is hexagonal, one story building in Japanese colonial period(picture 3-1) or the present(picture 3-3). The panaromic picture of Chung Yang Temple shows no alterations of the layout of buildings(picture 1-1), in which the Hall of $Praj{\tilde{n}}{\bar{a}}$(般若殿), the main building in the center and the Hall of Bhaisajyaguru(Healing) Budda, three story stone pagoda, stone lighthouse in front of it became the central axis. The Hall of Bhaisajyaguru(Healing) Budda remained as it was until Japanese invasions in 1592 and 1597. However, it was greatly damaged by the flood in 1717. It was newly built by Lee Ha Gon's leading in 1717-1732. At that time, the interior design was changed. With Bhaisajyaguru(Healing) Budda, 53 Buddhas and ${\acute{S}}arira$ of Stone stupa which show itself by the flood in 1717 was located in the image of the Mountain of Chunchuk or Cheontae like Yu Jeom Temple. The doors of this Hall are located in the front and back. In the four walls each, two realistic and cubic buddhism pictures were drawn, The color of those picture was partly taken off in 1671 and repainted in 1714. The new building in 1717-1732 regained its colorful appearance. However, the names written beside each Images of Buddha disappeared. The notable remark in these records is that some of these travel essays in 17th-18th centuries was calling this hexagonal hall as the octagonal one. It is very important records because it means that before 1525 the octagonal hall might have existed. Chung Yang Temple was rebuilt between 1976 and 1985 after the destruction in the Korean War. After the records are carefully read, the full scale excavation about this historic site was not done yet. The interesting issue of the existence of octagonal building will be resolved by the full scale excavation.

  • PDF

(Bi1⁄2Na1⁄2)1-xCaxTiO3 세라믹스의 압전 특성 및 상전이 거동 (Piezoelectric Properties and Phase Transition behaviors of (Bi1/2Na1/2)1- xCaxTiO3Ceramics)

  • 이용현;조정호;김병익;최덕균
    • 한국세라믹학회지
    • /
    • 제45권5호
    • /
    • pp.263-267
    • /
    • 2008
  • $(Bi_{1/2}Na_{1/2})TiO_3$-based ceramics have been intensively studied as lead-free piezoelectric ceramics. In this study, the piezoelectric properties and phase transition behaviors of BNT based solid solution $(Bi_{0.5}Na_{0.5})_{1-x}Ca_xTiO_3$ ($X=0.01{\sim}0.25$) were investigated. The morphotropic phase boundary(MPB) zone which BNT is transformed from rhombohedral to cubic structure was appeared by adding $CaTiO_3$ with 0.12 mol by the measurement of permittivity and X-ray diffraction. The behavior which ferroelectric BNT with adding $CaTiO_3$ was changed to antiferroelectric and paraelectric state was confirmed by the measurement ofhysterisis loop and depolarization temperature as a function of temperature. As $CaTiO_3$ concentration was increased, the phase transition temperature was decreased. The piezoelectric properties were highest at 0.01 mol of $CaTiO_3$ concentration. The electromechanical coupling factor($K_t$) and mechanical quality factor($Q_m$) were 42% and 254, respectively.

Benefit of the Drinking Water Supply System in Office Building by Rainwater Harvesting: A Demo Project in Hanoi, Vietnam

  • Dao, Anh-Dzung;Nguyen, Viet-Anh;Han, Mooyoung
    • Environmental Engineering Research
    • /
    • 제18권2호
    • /
    • pp.103-108
    • /
    • 2013
  • Vietnam is a developing country with the rate around 5%-6% per year, especially in urban areas. Rapidly developed urban areas lead to stress for infrastructure and the water supply is also stressed. In Hanoi city, total water capacity from the manufactories is around one million cubic meters per day and almost the entire main water source is groundwater but it is not enough to supply all of Hanoi's people, especially in the summer. A demo project is implemented in Hanoi University of Civil Engineering (HUCE) to produce drinking water by using the rainwater and membrane system and supply for people. In this project, rainwater is collected on the rooftop of the lecture building with an area of around $500m^2$ and $100m^3$ volumetric rainwater tanks. Afterwards, the rainwater is treated by the micro-membrane system and supplied to the tap water. Total cost for construction, technology and operation in the first year is around USD 48,558. In the long-term (15 yr) if HUCE invests in the same system, with $20m^3$ volumetric storage tank, it can provide drinking water for 500 staffs in every year. The cost of investment and operation for this system is lower than 30% compared to buying bottled water with the price USD 1.8/bottle. The drinking water parameters after treatment are pH, 7.3-7.75; turbidity, 0.6-0.8 NUT; total dissolved solids, 60-89 mg/L; coliform, 0; heavy metal similar with water quality in the bottle water in Vietnam.

Development and validation of a non-linear k-ε model for flow over a full-scale building

  • Wright, N.G.;Easom, G.J.;Hoxey, R.J.
    • Wind and Structures
    • /
    • 제4권3호
    • /
    • pp.177-196
    • /
    • 2001
  • At present the most popular turbulence models used for engineering solutions to flow problems are the $k-{\varepsilon}$ and Reynolds stress models. The shortcoming of these models based on the isotropic eddy viscosity concept and Reynolds averaging in flow fields of the type found in the field of Wind Engineering are well documented. In view of these shortcomings this paper presents the implementation of a non-linear model and its evaluation for flow around a building. Tests were undertaken using the classical bluff body shape, a surface mounted cube, with orientations both normal and skewed at $45^{\circ}$ to the incident wind. Full-scale investigations have been undertaken at the Silsoe Research Institute with a 6 m surface mounted cube and a fetch of roughness height equal to 0.01 m. All tests were originally undertaken for a number of turbulence models including the standard, RNG and MMK $k-{\varepsilon}$ models and the differential stress model. The sensitivity of the CFD results to a number of solver parameters was tested. The accuracy of the turbulence model used was deduced by comparison to the full-scale predicted roof and wake recirculation zone lengths. Mean values of the predicted pressure coefficients were used to further validate the turbulence models. Preliminary comparisons have also been made with available published experimental and large eddy simulation data. Initial investigations suggested that a suitable turbulence model should be able to model the anisotropy of turbulent flow such as the Reynolds stress model whilst maintaining the ease of use and computational stability of the two equations models. Therefore development work concentrated on non-linear quadratic and cubic expansions of the Boussinesq eddy viscosity assumption. Comparisons of these with models based on an isotropic assumption are presented along with comparisons with measured data.

화강암의 실내 가열실험에 대한 수치해석적 검토 (Numerical Analysis of Laboratory Heating Experiment on Granite Specimen)

  • 윤동준;손장윤;장리
    • 터널과지하공간
    • /
    • 제32권6호
    • /
    • pp.558-567
    • /
    • 2022
  • 고준위방사성폐기물의 지중저장 안정성 평가의 일환으로 가열 중인 화강암의 온도변화와 열응력 발생 양상을 파악하기 위하여 가열실험을 실시하였다. 폐기물의 붕괴열 발생조건을 가정하고 정육면체 형태의 화강암 시편에 적용하여 온도와 변위의 분포를 측정하였다. 시편의 온도는 가열봉에서 발생하는 전도로 인하여 즉각적으로 상승하지만 동시에 외기에 노출되거나 하중재하장치에 접촉되어 있는 표면을 통하여 상당한 양의 열에너지가 소산되었다. 해당 실험에 대한 분석과 이해를 위해 실험조건을 삼차원 유한요소 수치해석으로 재구현하였다. 실험에서 관찰된 열-역학 연계 현상과 주변조건의 변화를 해석에 적용하고 이를 실내실험 결과와 비교하여 검증하였다. 이를 통해 가열실험에 영향을 주는 인자들을 분석하고 향후 관련 연구에서 고려되어야 할 부분을 요약하였다.

아트리움 공간에 있어서 화재에 의한 연기 유동에 관한 수치해석적 연구

  • 노재성;유홍선;정연태
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1997년도 추계 학술논문발표회 논문집
    • /
    • pp.43-48
    • /
    • 1997
  • 아트리움 공간에서 화재 발생시 연기 유동에 대하여 두 가지 형태의 화재 모델인 zone 모델과 field 모델을 이용하여 시뮬레이션 했다. 사용된 zone model은 NIST에서 개발된 CFAST(version 1.6) 모델이며 field 모델은 전산유체역학 이론을 바탕으로 자체 개발된 화재 모델이다. 본 연구는 정육면체 모양의 아트리움 공간에서 연기 유동과 온도 분포에 대하여 해석하고자 한다. 화재로 인해 야기된 유동에 대하여 속도장과 은도장을 예측하기 위한 계산 과정은 유한체적법 및 비엇갈림격자계를 이용하여 질량, 운동량, 에너지 및 성분 보존 방정식등에 대한 3차원 비정상상태 지배방정식을 사용했다. 수치해석 결과 zone 모델과 field 모델의 화재 모델에 의해 예측된 연기 층 평균 경계놀이와 상부 더운 연기 층의 평균 온도에 대하여 거의 유사한 결과를 얻었다.

  • PDF