• Title/Summary/Keyword: Cu tube

Search Result 148, Processing Time 0.024 seconds

Effect of Vapor-Cooled Heat Stations in a Cryogenic Vessel (극저온액체 저장용기에서 열전도 차폐단의 영향)

  • Kim, S.Y.;Kang, B.H.;Choi, H.J.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.9 no.4
    • /
    • pp.169-176
    • /
    • 1998
  • An experimental study on effect of vapor-cooled heat stations in a 5.5 liter cryogenic vessel has been performed. The cryogenic vessel is made of stainless steel of thickness of 1mm and insulated by the combined insulation of vacuum, MLI(multi-layer insulation) and vapor-cooled radiation shield. Vapor-cooled heat stations are also constructed based on the 1-dimensional thermal analysis to reduce the heat inleak through a filling tube. Thermal analysis indicates that the vapor-cooled heat stations can substantially enhance the performance of vessel for cryogenic fluids with high $C_p/h_{fg}$ where $C_p$ the specific heat and $h_{fg}$ the heat of vaporization, such as $LH_2$ and LHe. The experimental results for $LN_2$ shows that the total heat inleak into inner vessel consists of 14% radiation and 86% conduction through the filling tube. Therefore, it is expected that the conduction heat in leak of the vessel for high $C_p/h_{fg}$ cryogenic fluids can be significantly reduced. powders. The amount of copper coating was 20wt%. In order to examine corrosion behavior of the electrodes, the corrosion current and the current density, in 6M KOH aqueous solution after removal of oxygen in the solution, were measured by potentiodynamic and cyclic voltamo methods. The results showed that Co in the alloy increased corrosion resistance of the electrode whereas Ni decreased the stability of the electrode during the charge-discharge cycles. The electrode used Si sealant as a binder showed a lower corrosion current density than the electrode used PTFE and the electrode used Cu-coated alloy powders showed the best corrosion resistance.

  • PDF

X-ray Induced Electron emission Spectroscopy

  • 송세안;이재철;최진학;김준홍;이재학;임창빈
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.191-191
    • /
    • 1999
  • Extended X-ray Absorption Fine Structure (EXAFS)는 일반적으로 널리 사용하는 X선 회절분광기로 분석하기 힘든 chemical 또는 biological system의 structural analyses에 매우 유용한 분석방법이다. 특히 세라믹이나 유전체 비정질 재료의 미세 원자 구조에 관한 정보를 얻는데는 가장 강력한 분석방법중의 하나로 알려져 있다. 현재까지 대부분의 EXAFS 실험은 방사광 가속기를 이용하여 수행하였다. 그런데 신제품 개발의 순환주기가 급속하게 단축되는 현실적인 문제에 부응하기 위하여 실험실에서 EXAFS 실험을 수행할 수 있는 system을 개발하게 되었다. 개발한 XIEES 장비는 rotating anode 형의 18kW X-ray source, Optical system, Detection system, Stepping motor control system, vacuum system, Utility 등으로 구성하였다. Optical system에서의 6개의 Johanson type monochromator를 사용하여 분석가능한 x-ray energy range를 480eV에서 41keV까지 구현하였다. 이는 산소에서 우라늄까지 분석이 가능함을 의미하는 것으로, 산화물 연구에 많이 활용할 것으로 기대한다. XIEES는 투과 및 형광 X-ray를 검출할 수 있는 기능과 X-ray에 의해 여기 되는 모든(광전자, Aiger 전자, 이차전자)들을 검출할 수 있는 기능을 갖추고 있는데 이를 Total Electron Yield 측정이라고 한다. Total Electron Yield 측정은 박막 시료와 같이 투과가 되지 않는 시료를 분석할 뿐만 아니라, 경원소 분석, 낮은 에너지에서 흡수 edge가 나타나는 L-edge 측정을 통한 전자 구조 분석 등에 유용한다. 실험실용 XIEES 장비는 방사광가속기에 비해 x-ray flux가 크게 뒤지는 문제와 Total Electron Yield를 측정하는 데 있어서 source에서 나오는 x-ray beam이 진공용기 안에서 산란되어 이차전자를 여기하고 이 이차전자들이 전자검출기에 유입되어 측정에 영향을 미치는 background 문제 등이 있다. 이 두 가지 문제를 해결하기 위하여 Capillary tube를 사용하였다. 본 연구에서는 실험실용 XIEES 장비를 소개하고 이를 이용하여 Cu standard 시료에서 측정한 EXAFS 결과와 Capillary tube를 사용하여 얻은 x-ray flux 증진 및 background 제거 효과에 대해서 발표한다.

  • PDF

Studies on Solvent Sublation of Trace Heavy Metals by Continuous Flow System as Ternary Complexes of 1,10-Phenanthroline and Thiocyanate Ion

  • Kim, Young-Sang;Choi, Yoon-Seok;Lee, Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1775-1780
    • /
    • 2003
  • A continuous flow system has been developed to determine trace Cu(II), Mn(II), Ni(II) and Zn(II) in a large volume of water samples by a solvent sublation technique. The mixed solution of 1,10-phenanthroline(phen) and thiocyanate ion was used as ligands for the formation of their ternary complexes. The continuous system was constructed in this laboratory with a peristaltic pump, a mini shaker, three mixing bottles and a flotation cell by connecting each part with a polyethylene tube. The flotation conditions such as the flow rate of sample solution and the injection rates of ligand, buffer and surfactant solutions have been investigated to obtain the best sublation efficiencies. Each solution flowed into the flotation cell through each polyethylene tube by the peristaltic pumps. The ternary complexes were floated and extracted into MIBK in a flotation cell of 2 L by bubbling a nitrogen gas. The absorbances of extracted analytes in MIBK were directly measured by graphite furnace-AAS. The concentrations of 1,10-phenanthroline and thiocyanate ion were $2.6\;{\times}\;10^{-3}$ M and $2.3\;{\times}\;10^{-2}$ M in the mixed solution, respectively. The pH of sample solution was adjusted to 5.0 with a buffer solution and 1%(m/v) sodium lauryl sulphate solution was added as a surfactant to support the effective flotation of the complexes. The $N_2$ gas was bubbled at 30 mL/min for 90 minutes for 20 L of sample. Reproducible results of less than 10% RSD and recoveries of 80-120% could be obtained in real samples.

Heavy Metal Adsorption Characteristics and Produced of Food Waste Activated Carbon (음식물류 폐기물 활성탄의 제조 및 중금속 흡착특성)

  • Lee, Jun-Hee;Lee, Seung-Chul;Ju, Min;Kim, Ji-Hye;Lee, Don-Gil
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1601-1608
    • /
    • 2015
  • This study evaluates heavy metal(Cu and Cr) adsorption characteristics produced from food waste charcoal extracted in an optimal operation condition after analyzing activated charcoal of iodine adsorption and heavy metals that derived from an activation process of carbide by the developed by-products of food waste treatment facility using the methods from previous studies. As experiment apparatus, this study used a tube-shaped high temp furnace. The mixing ratio of by-products of food waste treatment facility, carbide, and activation component($ZnCl_2$) was 1:1. The experiment was proceeded as adjusting the activation temperature from 400 to $800^{\circ}C$ and activation time from 30 to 120 minutes. The optimal activation condition for iodine absorption was 90 minutes at $700^{\circ}C$ and by using the produced food waste charcoal, this study conducted an experiment on absorption of heavy metals (Cu and Cr) as changing pH of artificial wastewater and stirring time. As a result, pH 7 showed the highest heavy metal decontamination ratio and in terms of stirring time, it revealed balance adsorption after 10 minutes. This result can be particularly applied as basic data for recyclability of high concentration organic waste, by-products of food waste treatment facility, as an food waste charcoal.

Adsorption of Heavy Metal Ions onto Chemically Oxidized Ceiba pentandra (L.) Gaertn. (Kapok) Fibers

  • Chung, Byung-Yeoup;Cho, Jae-Young;Lee, Min-Hee;Wi, Seung-Gon;Kim, Jin-Hong;Kim, Jae-Sung;Kang, Phil-Hyun;Nho, Young-Chang
    • Journal of Applied Biological Chemistry
    • /
    • v.51 no.1
    • /
    • pp.28-35
    • /
    • 2008
  • The physico-chemical properties of kapok fibers were altered via the combination processes of chlorite-periodate oxidation, in order to assess their efficacy as a heavy metal adsorbent. The chemically-oxidized kapok fibers were found to harbor a certain amount of polysaccharides, together with lowered lignin content. This alteration in lignin characteristics was clearly confirmed via FTIR and NBO yield. Moreover, chemically oxidized kapok fibers retained their hollow tube shape, although some changes were noted. The chemically oxidized kapok fibers evidenced elevated ability to adsorb heavy metal ions with the best fit for the Langmuir adsorption isotherm model. Three cycles of adsorption-desorption were conducted with in-between regeneration steps. Our experimental results indicated that chemically oxidized kapok fibers possessed excellent adsorption characteristics, and the modified kapok fibers could be completely regenerated with almost equimolar diluted sodium hydroxide. Pb, Cu, Cd and Zn ions evidenced adsorption rates of 93.55%, 91.83%, 89.75%, and 92.85% on the chemically oxidized kapok fibers. The regeneration efficiency showed 73.58% of Pb, 71.55% of Cu, 66.87% of Cd, and 75.00% of Zn for 3rd cycle with 0.0125N NaOH.

Comparison of microstructures in T1-1223/Ag tapes with different chemical compositions and J$_c$'s

  • Jeong, D.Y.;Kim, H.K.;Lee, H.Y.;Cha, M.K.;Ha, H.S.;Oh, S.S.;Tsuruta, T.;Horiuchi, S.
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.280-290
    • /
    • 1999
  • The microstructures of a Tl$_{0.8}Pb_{0.2}Bi_{0.2}Sr_{1.6}Ca_2Cu_3O_{9+{\delta}}$/Ag tape (tape I ) with J$_c$ of 17,600 A/cm$^2$ at 77 K and 0 T and three Tl$_{0.8}Pb_{0.2}Bi_{0.2}Sr_{1.8}Ba_{0.2}Ca_{2.2}Cu_3O_{9+{\delta}}$/Ag tapes with J$_c$'s of 9,300 (tape II), 16,700 (tape III) and 25,200 A/cm$^2$ (tape IV)prepared using the powder-in-tube method and an in-situ reaction method, were investigated using scanning electron microscopy and high-resolution transmission electron microscopy, and compared each other. ln the tape preparation, an intermediate rolling process was incorporated during final heat-treatment for the last tape, but not for the rest of the tapes. The microstructural analysis revealed clear differences in grain-texturing, crystallographic defects and impurity phases, depending on the chemical composition of the tape. Tendency of directional grain-alignment increased in an order of tapes I, II III and IV. In tape IV, T1-1223 grains are textured, at least in local regions. In crystallographic defects, while stacking faults were prevalent in the former composition, dislocations and voids were frequently observed in the latter. Also impurity phases were appeared to be more abundant in the former than in the latter. The relationship between 1,and the microstructure in the tapes was attempted to explain in a term of grain-linking.

  • PDF

Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy (복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구)

  • Hong, Seon Sook;Kang, Kyeong Mi;Seong, Min Suk;Lee, Jong Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

YBCO 박막형 선재의 개발현황

  • 홍계원;이희균
    • Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.14-20
    • /
    • 1999
  • 초전도 재료는 선재의 형태로 가공하면 송전선이나 변압기, 발전기 그리고 전력 저장장치 등에 사용되어 전력계통의 효율을 극대화시킬 수 있는 재료로서 실제 응용 기기의 개발을 위해 많은 연구가 수행되고 있다. 더우기 1980년대 후반에 개발된 고온초전도 산화물 재료는 액체질수의 비등점인 77K 이상에서 초전도현상을 나타내어 초전도 현상의 응용에 대한 기대를 고조시켜 이에 대한 연구를 더욱 활성화시키고 있다. 초전도선재 연구는 그간 PIT(Powder in Tube) 공정을 이용한 Ag/Bi-2223(Ag/$Bi_2Sr_2Ca_2Cu_3O$) 선재가 높은 전기적 성질과 장선 가공상의 잇점으로 인해 많은 연구와 성과가 있었다. 그러나 Ag/Bi-2223선재는 강한 자기장 하에서 통전 능력이 현저하게 저하되는 성질 때문에 높은 자기장하에서 사용하기 위해서는 사용온도를 액체질소온도보다 상당히 낮은 20K 부근까지 낮추어야 한다는 점 때문에 전력기기 개발에 제한이 따르는 단점이 있다. 이에 반해 최근에 개발된 금속/YBCO 박막 복합선재는 높은 전기적 특성 이외에 특히 높은 자장에서도 통전 능력의 저하가 적어 제한 없이 전력기기의 모든 분야에 사용할 수 있는 특징이 있다. 따라서 1993년에 일본에서 Ni 금속기판에 물리적 증착방법으로 YBCO($YiBa_2Cu_3O$) 박막을 증착시킨 선재제조에 성공하고 있어 1996년에 Oak Ridge National Laboratories (ORNL)에서 Rolling Assisted Biaxially Textured Substrate (RaBiTS) 라는 집합조직을 형성시킨 금속기판이 개발되어 연속적인 가공의 가능성이 확인된 후 이의 특성향상 및 가공기술 개발을 위한 많은 연구가 수행되고 이다. 이 글에서는 이제 까지 개발된 금속기판을 사용한 YBCO계 초전도 박막형 선재의 제조기술 중에서 최근 가장 가능성 있는 것으로 평가되는 RABiTS 방법을 위주로 그 외에 IBAD와 ISD 방법에 관하여 소개하고 현재까지의 개발현황 및 앞으로의 전망에 대하여 간략하게 기술하고자 한다.

  • PDF

Selective tyrosine conjugation with a newly synthesized PCB -TE2A-luminol bifunctional chelator

  • Subramani Rajkumar;Hyun Park;Abhinav Bhise;Seong Hwan Cho;Jung Young Kim;Kyo Chul Lee;Jeongsoo Yoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.7 no.2
    • /
    • pp.85-91
    • /
    • 2021
  • Selective amino acid conjugation of bulky antibodies is a valuable asset for real-time diagnosis and therapy. However, selective conjugation incorporating a chelate-bearing radioactive atom into an antibody without affecting its immunoreactivity is a challenging task. A bifunctional chelator (BFC), a selective amino acid-targeting probe, and a linker have been developed to overcome this problem. Here, we report the synthesis of a novel propylene cross-bridged chelator (PCB)-1,8-N,N'-bis-(carboxymethyl)-1,4,8,11-tetraazacyclotetradecane (TE2A)-luminol BFC via a click reaction and radiolabel it with a 64Cu ion for tyrosine-selective conjugation of trastuzumab. In the initial optimization study, we tried different oxidative addition conditions such as electro-oxidation, hemin, horseradish peroxidase, iodogen tube, chloramine-T, and iodo beads. In this study, up to 82% of 64Cu-PCB-TE2A-luminol was conjugated with the antibody in an iodo bead-catalyzed oxidative addition reaction with an isolated yield of 24.4%.

A Study on the Metal to Zirconia Joining by Applying Direct Current (직류전원부하에 의한 지르코니아와 금속의 접합)

  • Kim Sung Jin;Kim Moon Hyop;Park Sung Bum;Gwon Won Il
    • 한국전기화학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.383-390
    • /
    • 2005
  • Effect of applying a DC voltage on the interfacial reaction at the metal to zirconia interface was investigated utilizing an oxygen ionic conductivity of partially stabilized zirconia. The joining of copper rod and zirconia tube was carried out in Ar gas atmosphere at $1000^{\circ}C$. There are two type of the joining. The one is the reaction bond consisting of copper and zirconia was dominated by surface reaction with a undetectable very thin layer. It was found that copper elements were diffused to zirconia side, but that Zr ions were not diffused to copper side. These results mean application of a DC voltage to migrate oxygen to the copper-zirconia interface can oxidize metal at the copper-zirconia interface and the bonding reaction between zirconia and copper oxide may occur. The other is the reaction bonding was dominated by interdiffusion with a very thick interface layer. This result mean application of a DC voltage can reduce zirconia at the interface. The bonding reaction is to be an alloying between Zr and Cu.

  • PDF