• 제목/요약/키워드: Cu electrode

검색결과 494건 처리시간 0.028초

PASB 아크 플라즈마 챔버에서 발생하는 유동 및 물질전달에 관한 연구 (Study on the Flow and Mass Transfer in a PASB Arc Plasma Chamber)

  • 이종철;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제11권4호
    • /
    • pp.7-13
    • /
    • 2008
  • The computational investigation is performed to find out the interaction of arc plasmas with surrounding materials and the thermal flow characteristics in a PASB (Puffer-Assisted Self-Blast) chamber, which is one of new breaking concepts in $SF_6$ switchgears. It is very important to define the flow and mass transfer happened during the full arcing history for further understanding complex physics inside the chamber. In this study, we have considered two diffusion processes by the hot arc plasma, one is PTFE nozzle ablation and the other is Cu electrode evaporation, simultaneously. It was found that the principle of the pressure-rise inside the chamber is confirmed by the computational results and the increase of the electrical conductivity of the residual gas near current zero is critical to the chamber design.

자동차 배기가스용 NOx센서의 감도향상를 위한 새로운 산화물 감지물질과 변형된 혼합전위 센서의 개발 (The development of new oxide materials and modified mixed potential sensing method for highly sensitive NOx sensor)

  • 박진수;윤병영;박종욱
    • 센서학회지
    • /
    • 제17권1호
    • /
    • pp.61-68
    • /
    • 2008
  • The sensing characteristics of new oxide sensing materials, NiO, NiO-YSZ and CuO, were evaluated at the temperature of $700^{\circ}C$ in 10 % $O_2$containing atmosphere. Through simultaneous response to $NO_2$ and NO, the sensing mechanism of oxide electrode was studied and the relation of EMF and NO/$NO_2$ concentrations was elucidated. Moreover, for highly sensitive NOx sensor, modified mixed potential sensor which has at least two oxide electrodes was proposed.

Influence of Tank Inner Side Dielectric Coating on the Particle Behaviour and Flashover Voltage in SF\ulcorner Gas Insulated System

  • Lee, Bang-Wook;Koo, Ja-Yoon
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권3호
    • /
    • pp.77-81
    • /
    • 1997
  • In his work, the influence of wire type conducting particles on the insulation reliability of GIS has been systematically investigated when the epoxy resin based dielectric coating was made on he inner side of outer electrode. For this purpose, coaxial cylinder-type electrode was adopted in 362 kV chamber and various sizes of Cu conducting particle were used under different gas pressures. In order to elucidate the coating effect on the gas insulation, different thickness of dielectric coating has been considered and then the lift-off voltage and flashover voltages have been measured. The results shown that the dielectric coating has a remarkable influence by restraining the movement of particle in GIS system, and thus GIS insulation reliability is noticeably improved.

  • PDF

Ion Beam Assisted DC Planar Magnetron Sputtering 장치에 의한 PDP용 방전전극 형성에 관한 연구 (A Study on Discharge Electrode Formation for PDP with Ion Beam Assisted DC Planar Magnetron Sputtering Device)

  • 김준호;손진부;신중홍;조정수;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1791-1793
    • /
    • 1998
  • The thin film metal electrode for PDP needs low resistivity and strong adhesion. But the sputtered copper film is weak, in the adhesion between copper and glass. In this paper, we investigated the characteristics of resistivity and adhesion about Cu thin film using Ion Beam Assisted DC Planar Magnetron Sputtering(DCPM) Device.

  • PDF

금속 니트로소 R염 착물을 이용한 염기성 의약품 선택성 전극의 특성 (Potentiometric Characteristics of Nitroso.R-Salt-Metal Complex Based Basic Drug Selective Electrodes)

  • 이미나;안문규
    • 약학회지
    • /
    • 제47권6호
    • /
    • pp.356-360
    • /
    • 2003
  • Nitroso-2-naphthol-3,6-disulfonic acid, disodium salt (NRS) was used as an organic ligand to prepare basic drug-selective polymeric membrane electrode. The sensing membrane of the electrode consited of basic drug-meta1(II)-NRS as an ion-exchanger site in a poly(vinyl chloride) matrix plasticized with 2-nitrophenyl octyl ether (NPOE). The metal ions used were Fe$^{2+}$, Co$^{2+}$, Ni$^{2+}$ and Cu$^{2+}$. The electrodes exhibited fast and wide linear response in the basic drug concentration of 10$^{-5}$ ∼10$^{-3}$ mol/l with a response slope of 50∼60 mV/decade in a buffer solution of pH 4∼8. The electrodes exhibited good selectivity for many basic compounds.mpounds.

플렉서블 디스플레이용 투명전극 제조를 위한 ITO 대체소재 연구동향

  • 김선옥;최수빈;김종웅
    • 세라미스트
    • /
    • 제21권1호
    • /
    • pp.12-23
    • /
    • 2018
  • As the flexible displays have been considered as a breakthrough to make a new electronics category, transparent electrodes have also confronted with an emerging issue, i.e., they also need to be mechanically flexible. For this to be made possible, a transparent electrode capable of withstanding large amounts of strain must be developed. Indium tin oxide (ITO) has been one of the most widely adopted transparent electrodes for displays and other transparent electronics, mainly supported by its high electrical conductivity and optical transparency. However, its brittle nature has forced the display industry to search for other alternatives. Recently, advances in nano-material researches have opened the door for various transparent conductive materials, which include carbon nanotube, graphene, Ag and Cu nanowire, and printable metal grids. Here we reviewed recently-published research works introducing flexible displays, all of which are employing the novel candidates for a conducting material.

흡착벗김 전압전류법에 의한 시안화이온의 정량 (Determination of Cyanide Ion by Adsorptive Stripping Voltammetry)

  • 차기원;고수진;김재균
    • 분석과학
    • /
    • 제14권6호
    • /
    • pp.540-544
    • /
    • 2001
  • Determination of cyanide ion has been studied by adsorptive stripping voltammetry using hanging mercury electrode. Cyanide ion complexed with copper ion is adsorpbed on the electrode and oxidised at the positive potential scan. Optimal conditions of CN determination were found to be ; supporting electrolyte solution ; 0.1 M NaCl of ammonium buffer at pH 10, accumulation potential; -800 mV vs Ag/AgCl, accumulation time ; 300 s, scan rate ; 50mV/s. The linear concentration of cyanide ion was observed in the range $1{\times}10^{-8}$, $1{\times}10^{-7}M$. The detection limit(n/s=3) was $0.13{\mu}g/L$($5{\times}10^{-9}M$) with 3.5% RSD.

  • PDF

이종금속전극이 증착된 XLPE필름의 전기전도 특성 (Electrical Conduction Characteristics of XLPE Film evaporated Different Metal Electrode)

  • 이흥규;이운영;임기조;김용주
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권8호
    • /
    • pp.557-562
    • /
    • 1999
  • Electrical conduction characteristics of XLPE film evaporated with different metal electrode are discussed. The relation between electrical current(I) and Voltage(V) in the M(metal)-I(XLPE)-M(metal) structure are measured in the temperature range from 25$[^{\circ}C]$ to 90[$[^{\circ}C]$ . Several kinds of metals are used as electrode, such as, Al, Ag and Cu.From the experimental results, it is conclused that the conduction mechanism at highelectric field is SCLC. The dependences of temperature and kinds of metal on the trap filled electric field level can be well explained by this theory.

  • PDF

Investigation of Water Safety in Non-treated Drinking Water with Trace Toxic Metals

  • Ly, Suw Young;Kim, Dae Hong;Lee, Ga Eun
    • Toxicological Research
    • /
    • 제29권3호
    • /
    • pp.211-215
    • /
    • 2013
  • The trace toxic metal copper was assayed using mercury immobilized on a carbon nanotube electrode (MCW), with a graphite counter and a reference electrode. In this study, a macro-scale convection motor was interfaced with a MCW three-electrode system, in which a handmade MCW was optimized using cyclic- and square-wave stripping voltammetry. An analytical electrolyte for tap water was used instead of an expensive acid or base ionic solution. Under these conditions, optimum parameters were 0.09 V amplitude, 40 Hz frequency, 0.01 V incremental potential, and a 60-s accumulation time. A diagnostic working curve was obtained from 50.0 to 350 ${\mu}g/L$. At a constant Cu(II) concentration of 10.0 ${\mu}g/L$, the statistical relative standard deviation was 1.78% (RSD, n = 15), the analytical accumulation time was only 60 s, and the analytical detection limit approached 4.6 ${\mu}g/L$ (signal/noise = 3). The results were applied to non-treated drinking water. The content of the analyzed copper using 9.0 and 4.0 ${\mu}g/L$ standards were 8.68 ${\mu}g/L$ and 3.96 ${\mu}g/L$; statistical values $R^2$ = 0.9987 and $R^2$ = 0.9534, respectively. This method is applicable to biological diagnostics or food surveys.

대전력 펄스용 횡자계형 및 종자계형 진공스위치의 에너지 손실 특성 비교 (A Comparison of Energy Loss Characteristics between Radial and Axial Magnetic Field Type Vacuum Switches)

  • 이태호;허창수;이홍식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권3호
    • /
    • pp.130-136
    • /
    • 2003
  • Crowbar system Vacuum switches, widely used In a pulsed power system, could use the magnetic force to prevent the electrode damage. Vacuum switches using the magnetic forces are classified roughly into RMF(Radial Magnetic Field) and AMF(Axial Magnetic Field) type. The RMF type switches restrain a main electrode from aging due to high temperature and high density arc by rotating the arc which is driven by the Lorenz force. The AMF type switches generate axial magnetic field which decreases the electrode damage by diffusing arc. In this paper, we present the energy loss characteristics of both RMF and AMF type switches which are made of CuCr(75:25 wt%) electrodes. The time-dependent dynamic arc resistance of high-current pulsed discharge in a high vacuum chamber(~10$^{-6}$ Torr). which occurs in RMF and AMF type switches, was obtained by solving the circuit equation using the measured values of the arc voltage and current. In addition, we compared energy loss characteristics of both switches. Based on our results, it was found that the arc voltage and the energy loss of an AMF type switch are lower than a RMF type switch.