• 제목/요약/키워드: CsI

Search Result 626, Processing Time 0.024 seconds

Comparative and Feasibility Evaluation of Detection Ability of Relative Dosimeters using CsPbI2Br and CsPbIBr2 Materials in Brachytherapy QA (근접방사선치료 QA에서 CsPbI2Br과 CsPbIBr2를 이용한 상대 선량계들의 검출 능력 비교 및 적용가능성 평가)

  • Seung-Woo Yang;Sung-Kwang Park
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.433-440
    • /
    • 2023
  • High dose rate brachytherapy is a cancer treatment that intensively irradiates radiation to tumors by inserting isotopes with high dose rates into the body. For such a treatment, it is necessary to deliver an accurate dose to the tumor tissue through an accurate treatment plan while delivering only a minimum dose to the normal tissue. Therefore, it is very important to check the location accuracy of the source through accurate Quality Assurance (QA) in clinical practice. However, since the source position is determined using a ruler, automatic radiographer, video monitor, etc. in clinical practice, it yields inaccurate results. In this study, a semiconductor dosimeter using CsPbI2Br and CsPbIBr2 was fabricated. And, in order to analyze whether it is more suitable for the relative QA dosimeter for brachytherapy device among the two materials, the radiation detection ability of each was compared and evaluated. In order to evaluate the radiation detection ability in brachytherapy, the reproducibility and linearity of the two materials were evaluated in 192IR. In the reproducibility evaluation, CsPbI2Br presented a Relative Standard Deviatio(RSD) of 0.98% and CsPbIBr2 presented an RSD of 3.45%. In the linearity evaluation, the coefficient of determination (R2) of CsPbI2Br was presented as 0.9998, and the R2 of CsPbIBr2 was presented as 0.9994. As a result of the evaluation, it was found that CsPbI2Br was more stable in radiation detection while satisfying the evaluation criteria in the dosimeter manufactured in this experiment. Therefore, CsPbI2Br material is suitable for application as a relative dosimeter for radiation detection in brachytherapy devices.

Renal dehydropeptidase-I (DHP-I) Stability and Pharmacokinetics of DA-1131, A New Carbapenem Antibiotic

  • Kim, Ji-Young;Kim, Gye-Won;Park, Seong-Hak;We, Jeoung-Soon;Park, Haeng-Soon;Junnick Yang
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.238-238
    • /
    • 1996
  • 각종 동물 및 인체 신장 유래 DHP-I에 의한 DA-1131, imipenem(IPM) 및 meropenem(MEPM)의 속도 상수를 측정한 결과, DA-1131은 동물종에 관계없이 가장 안정성이 큰 결과를 나타내었고, 인체 DHP-I에 대한 Vmax/Km 값이 IPM의 21.9%로 관찰되어 IPM보다 하위 기질인 것으로 확인되었다. DA-1131, IPM/CS 및 MEPM/CS의 20mg/kg투여 후의 혈중농도 반감기(T$_{1}$2/)는 각각 11.4분, 8.9분, 10.3분이었으며, 1$\mu\textrm{g}$/$m\ell$ 이상의 혈중농도룰 유지하는 시간은 66.6 분, 55.9 분, 63.1 분이었다. DA-1131, DA-l131/CS, IPM/CS, MEPM 및 MEPM/CS의 40 mg/kg 투여 후 24시간 동안의 뇨중 배설율은 57.9 %, 61.3%, 22.6 %, 11.3% 및 65.9%이었으며, 각 약물을 40 mg/kg 투여 15분 후 DA-ll3l의 폐중 농도는 11.2$\mu\textrm{g}$/g으로 DA-l131/CS, IPM/CS 및 MEPM/CS와 비슷한 결과를 나타내었으며 T/P ratio도 DA-1131, DA-l131/CS, IPM/CS 와 MEPM/CS 투여군에서 거의 동일한 것으로 확인되었다. 신장중 농도는 DA-1131 과 DA-l131/CS의 경우 29.l$\mu\textrm{g}$/g 및 34.2$\mu\textrm{g}$/g으로 큰 차이를 나타내지 않았으나, IPM/CS, MEPM 및 MEPM/CS 투여군에 비하여는 높은 결과로 나타났고 T/P ratio도 DA-1131과 DA-l131/CS 투여군이 IPM/CS, MEPM 및 MEPM/CS 투여군보다 놓은 것으로 확인되었다.

  • PDF

Crystal Growth and Scintillation Properties of CsI:Gd (CsI:Gd 결정 육성과 섬광 특성)

  • Cheon, Jong-Kyu;Kim, Sung-Hwan;Kim, Hong-Joo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.293-297
    • /
    • 2012
  • CsI:Gd crystal was grown by the Bridgeman method and its scintillation properties were investigated. The wavelength peak of the luminescence spectrum for the crystal excited by X-ray was 419 nm. The range of the spectrum was from 300 nm to 800 nm. The spectrum well matched to the quantum efficiency of a typical bi-alkali photo-multiplier tube(PMT). An energy resolution of 48.2 % was obtained for 662 keV ${\gamma}$-rays of $^{137}Cs$. The three decay times were obtained as a fast(557.4 ns, 42.2 %), intermediate (1.78 ${\mu}s$, 29.7 %) and slow (5.43 ${\mu}s$, 28.1 %) components, respectively.

Image Quality Evaluation of CsI:Tl and Gd2O2S Detectors in the Indirect-Conversion DR System (간접변환방식 DR장비에서 CsI:Tl과 Gd2O2S의 검출기 화질 평가)

  • Kong, Changgi;Choi, Namgil;Jung, Myoyoung;Song, Jongnam;Kim, Wook;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • The purpose of this study was to investigate the features of CsI:Tl and $Gd_2O_2S$ detectors with an indirect conversion method using phantom in the DR (digital radiography) system by obtaining images of thick chest phantom, medium thickness thigh phantom, and thin hand phantom and by analyzing the SNR and CNR. As a result of measuring the SNR and CNR according to the thickness change of the subject, the SNR and CNR were higher in CsI:Tl detector than in $Gd_2O_2S$ detector when the medium thickness thigh phantom and thin hand phantom were scanned. However, when the thick chest phantom was used, for the SNR at 80~125 kVp and the CNR at 80~110 kVp in the $Gd_2O_2S$ detector, the values were higher than those of CsI:Tl detector. The SNR and CNR both increased as the tube voltage increased. The SNR and CNR of CsI:Tl detector in the medium thickness thigh phantom increased at 40~50 kVp and decreased as the tube voltage increased. The SNR and CNR of $Gd_2O_2S$ detector increased at 40~60 kVp and decreased as the tube voltage increased. The SNR and CNR of CsI:Tl detctor in the thin hand phantom decreased at the low tube voltage and increased as the tube voltage increased, but they decreased again at 100~110 kVp, while the SNR and CNR of $Gd_2O_2S$ detector were found to decrease as the tube voltage increased. The MTF of CsI:Tl detector was 6.02~90.90% higher than that of $Gd_2O_2S$ detector at 0.5~3 lp/mm. The DQE of CsI:Tl detector was 66.67~233.33% higher than that of $Gd_2O_2S$ detector. In conclusion, although the values of CsI:Tl detector were higher than those of $Gd_2O_2S$ detector in the comparison of MTF and DQE, the cheaper $Gd_2O_2S$ detector had higher SNR and CNR than the expensive CsI:Tl detector at a certain tube voltage range in the thick check phantom. At chest X-ray, if the $Gd_2O_2S$ detector is used rather than the CsI:Tl detector, chest images with excellent quality can be obtained, which will be useful for examination. Moreover, price/performance should be considered when determining the detector type from the viewpoint of the user.

Effect of pepper tree (Schinus molle) essential oil-loaded chitosan bio-nanocomposites on postharvest control of Colletotrichum gloeosporioides and quality evaluations in avocado (Persea americana) cv. Hass

  • Chavez-Magdaleno, Mireya Esbeiddy;Gonzalez-Estrada, Ramses Ramon;Ramos-Guerrero, Anelsy;Plascencia-Jatomea, Maribel;Gutierrez-Martinez, Porfirio
    • Food Science and Biotechnology
    • /
    • v.27 no.6
    • /
    • pp.1871-1875
    • /
    • 2018
  • Preventive and curative activity of postharvest treatments with chitosan nanoparticles (CS) and chitosan biocomposites loaded with pepper tree essential oil (CS-PEO) against anthracnose were evaluated on Avocado (Persea americana) cv. Hass artificially inoculated in rind wounds. After 10 days of storage significant preventive and curative activity against Colletotrichum gloeosporioides was observed with the absence of internal damage by applying CS and CS-PEO. Quality parameters like water losses and firmness changes were assessed on fruit treated. CS and CS-PEO were effective to reduce water losses and firmness losses.

TL Characteristics of CsI Single Crystal Scintillators and their Growth Conditions (CsI 단결정 섬광체의 열형광특성과 육성조건)

  • Doh, S.H.;Lee, W.G.;Hong, S.Y.;Bang, S.W.;Kang, K.J.;Kim, D.S.;Kim, W.;Kang, H.D.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.234-242
    • /
    • 1998
  • Changes in transmission and thermoluminescent characteristics were used in order to find out the optimum growth condition of CsI single crystal scintillators which were made relatively defect-free using Czochralski method. Impurity distribution in the crystals and the intensity and number of thermoluminescent glow peaks decreased as the process of crystallization was repeated. The direction of crystal growth turned out to be (110), the crystal structure of grown CsI was bee, and its lattice constant was found to be $4.568{\AA}$. The activation energy (trap depths) of CsI:3rd was 0.45 eV and its frequency factor was $5.18{\times}10^5\;sec^{-1}$.

  • PDF

Effect of FK506 and Cyclosporin A on $I{\kappa}B{\alpha}$ Degradation and $IKK{\alpha}$ Pathway in Bronchial Epithelial Cells, Monocytes, Lymphocytes and Alveolar Macrophages (FK506과 cyclosporin A가 기관지상피세포, 단핵구, 림프구 및 폐포대식세포에서 $I{\kappa}B{\alpha}$ 분해 및 $IKK{\alpha}$ 활성에 미치는 효과)

  • Yoon, Ho Il;Lee, Chang-Hoon;Lee, Hee-Seok;Lee, Choon-Taek;Kim, Young Whan;Han, Sung Koo;Shim, Young-Soo;Yoo, Chul-Gyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.4
    • /
    • pp.449-458
    • /
    • 2003
  • Background : Cyclosporin A(CsA) and tacrolimus(FK506) have been widely used as immunosuppressants. The effects of CsA, or FK506, on the $I{\kappa}B/NF-{\kappa}B$ pathway have been shown to vary according to the cell type. However, their effects on the $I{\kappa}B/NF-{\kappa}B$ pathway have not been reported in bronchial epithelial cells. In this study, the effects of CsA and FK506 on the $I{\kappa}B/NF-{\kappa}B$ pathway in bronchial epithelial cells, monocytes, lymphocytes and alveolar macrophages were evaluated. The relationship between their effects on the $I{\kappa}B/NF-{\kappa}B$ pathway and $I{\kappa}B$ kinase(IKK) activity was also investigated. Methods : BEAS-2B and A549 cells, pulmonary alveolar macrophages, peripheral blood monocytes and lymphocytes were used. The cells were pre-treated with CsA, or FK506, for various time periods, followed by stimulation with TNF-${\alpha}$, LPS or IL-$1{\beta}$. The $I{\kappa}B{\alpha}$ expressions were assayed by Western blot analyses. The IKK activity was evaluated by an in vitro immune complex kinase assay, using GST-$I{\kappa}B{\alpha}$ as the substrate. Results : Neither CsA nor FK506 affected the level of $I{\kappa}B{\alpha}$ expression in any of the cell types used in this study. CsA pre-treatment inhibited the TNF ${\alpha}$-induced $I{\kappa}B{\alpha}$ degradation in bronchial epithelial cells. In contrast, the TNF ${\alpha}$-induced $I{\kappa}B{\alpha}$ degradation was not affected by FK506 pre-treatment. However, FK506 suppressed the cytokine-induced $I{\kappa}B{\alpha}$ degradation in the pulmonary alveolar macrophages, peripheral blood monocytes and lymphocytes. The inhibitory effect of CsA, or FK506, on $I{\kappa}B{\alpha}$ degradation was not related to IKK. Conclusions : CsA and FK506 suppressed the $I{\kappa}B{\alpha}$ degradation in bronchial epithelial cells, monocytes, lymphocytes and alveolar macrophages, so this may not be mediated through IKK.

Optical Properties of $Pr^{3+}$-Doped Chalcohalide Glasses ($Pr^{3+}$ 첨가 찰코할라이드 유리의 광학적 특성)

  • Choe, Yong-Gyu;Gang, Bong-Hun;Song, Jae-Hyeok;Jeong, Un-Jin;Heo, Jong;Park, Bong-Je;Seo, Hong-Suk;An, Jun-Tae
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.02a
    • /
    • pp.143-144
    • /
    • 2007
  • 낮은 포논 에너지를 가지는 대표적인 비정질 광소재인 Ge-Ga-Sb-Se 조성의 셀레나이드 유리에 CsI를 첨가한 찰코할라이드 유리 샘플을 제작하고 CsI 함량에 따른 소재의 광 특성 및 첨가된 $Pr^{3+}$ 이온의 광 특성 변화를 조사하였다. 안정한 비정질 상태를 유지하는 CsI의 함량은 약 7.5 몰%로 제한되었으며, 첨가량에 비례하여 단파장 흡수단 파장이 짧아지는 경향을 보였으나 weak absorption tail이 증가 하였다. $Pr^{3+}$ 이온으로부터 발생하는 1.6 ${\mu}m$대역 형광의 제반특성은 CsI의 첨가와 비교적 무관한 것으로 밝혀졌으며 1.06 ${\mu}m$장에서 측정한 비선형 흡수 계수 역시 CsI의 첨가에 영향을 거의 받지 않는 것으로 판명되었다.

  • PDF

The X-ray Detection Characteristic of vacuum evaporated CsI for Digital X-ray Image Sensor (디지털 X선 영상센서 적용을 위한 진공증착 CsI 특성평가)

  • Shin, Jung-Wook;Park, Ji-Koon;Choi, Jang-Yong;Seok, Dea-Woo;Kim, Jea-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.15-18
    • /
    • 2003
  • In recent years, there has been keen interest in phosphor materials responding X-ray. Cesium iodide of the materials is a material with a high $\gamma$-ray stopping power due to its relative high density and atomic number. CsI is noted for its high resistance to thermal and mechanical shock due to the absence of a cleavage plane. To design the structure of CsI detector, we analysed the structure with SEM and XRD and measured UV meter.

  • PDF

Toward iSchools: from the Perspective of the 5Cs

  • Yi, Myongho
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.50 no.1
    • /
    • pp.313-330
    • /
    • 2016
  • A coalition of information schools, called the iSchools Organization, was established to increase the visibility of library and information science and to cope with the new demands of the digital age. As of 2015, sixty-five schools from many different countries have joined the iSchools Organization. While some other schools are interested in adopting iSchools, there are still some issues that need to be considered before adopting the iSchool charter. This paper presents those issues from the perspectives of the 5C groups: curriculum, competencies, convergence, collaboration, and consensus. A survey was conducted to investigate some aspects of the 5Cs. This study identifies five iSchool-related issues - 5Cs. Providing perspectives in the areas of the 5Cs will be useful to establish stronger iSchools. These five Cs will resolve information problems that we are facing, prepare students or any organizations for the digital age, give students digital service skills, and train future data scientists. This paper represents practical guidelines to build a strong iSchool. With the success of iSchools, societies see us as more than the traditional librarian.