• Title/Summary/Keyword: CsF

Search Result 237, Processing Time 0.027 seconds

Storage stability of reduced sulfur gases in Tedlar bag sampler: Test of two different storing approaches (Tedlar-bag 시료채집법을 이용한 황화합물의 경시적 농도 변화특성: 시료의 생성방식의 차이에 따른 비교연구)

  • Jo, Hyo-Jae;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.212-218
    • /
    • 2011
  • In this study, temporal stability of 5 reduced sulfur compounds (RSCs) including ($H_2S$, $CH_3SH$, DMS, $CS_2$, and DMDS) was investigated up to 30 days. To learn the temporal changes in RSC concentration levels, two types of long-term storage experiment were carried out by employing two different approaches for sample storing in Tedlar bag samplers. The first one named as a forward (F) storage method consists of preparing all samples in the beginning of experiment. All these samples were analyzed sequentially through time. The second approach named as a reversed (R) storage method was carried out by preparing each sample through time and by analyzing all of them in the last day. For these experiments, RSC standards were prepared at 10 ppb in 10 L Tedlar bag. The results of both methods were consistent enough to show a tendency of the concentration reduction through time. Moreover, the lightest RSC, $H_2S$ showed the most significant reduction of 84.8% at the end of experiment. To validate difference between these results, t-test was applied to the data obtained between the two methods at 90% significance level. According to t-test, the results of the two approaches were greatly distinguished from 3 RSCs ($H_2S$, $CH_3SH$, and DMDS). The results also indicated that the temporal reduction of RSC differs greatly between light ($H_2S$ and $CH_3SH$) and heavy RSCs (DMS, DMDS, and $CS_2$). The former generally exhibited much significant reduction through time due probably to their lower stability.

Quantitative Differences between X-Ray CT-Based and $^{137}Cs$-Based Attenuation Correction in Philips Gemini PET/CT (GEMINI PET/CT의 X-ray CT, $^{137}Cs$ 기반 511 keV 광자 감쇠계수의 정량적 차이)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Park, Eun-Kyung;Kim, Jong-Hyo;Kim, Jae-Il;Lee, Hong-Jae;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.182-190
    • /
    • 2005
  • Purpose: There are differences between Standard Uptake Value (SUV) of CT attenuation corrected PET and that of $^{137}Cs$. Since various causes lead to difference of SUV, it is important to know what is the cause of these difference. Since only the X-ray CT and $^{137}Cs$ transmission data are used for the attenuation correction, in Philips GEMINI PET/CT scanner, proper transformation of these data into usable attenuation coefficients for 511 keV photon has to be ascertained. The aim of this study was to evaluate the accuracy in the CT measurement and compare the CT and $^{137}Cs$-based attenuation correction in this scanner. Methods: For all the experiments, CT was set to 40 keV (120 kVp) and 50 mAs. To evaluate the accuracy of the CT measurement, CT performance phantom was scanned and Hounsfield units (HU) for those regions were compared to the true values. For the comparison of CT and $^{137}Cs$-based attenuation corrections, transmission scans of the elliptical lung-spine-body phantom and electron density CT phantom composed of various components, such as water, bone, brain and adipose, were performed using CT and $^{137}Cs$. Transformed attenuation coefficients from these data were compared to each other and true 511 keV attenuation coefficient acquired using $^{68}Ge$ and ECAT EXACT 47 scanner. In addition, CT and $^{137}Cs$-derived attenuation coefficients and SUV values for $^{18}F$-FDG measured from the regions with normal and pathological uptake in patients' data were also compared. Results: HU of all the regions in CT performance phantom measured using GEMINI PET/CT were equivalent to the known true values. CT based attenuation coefficients were lower than those of $^{68}Ge$ about 10% in bony region of NEMA ECT phantom. Attenuation coefficients derived from $^{137}Cs$ data was slightly higher than those from CT data also in the images of electron density CT phantom and patients' body with electron density. However, the SUV values in attenuation corrected images using $^{137}Cs$ were lower than images corrected using CT. Percent difference between SUV values was about 15%. Conclusion: Although the HU measured using this scanner was accurate, accuracy in the conversion from CT data into the 511 keV attenuation coefficients was limited in the bony region. Discrepancy in the transformed attenuation coefficients and SUV values between CT and $^{137}Cs$-based data shown in this study suggests that further optimization of various parameters in data acquisition and processing would be necessary for this scanner.

Relationship between academic stress, sleep quality and depression in nursing college students (간호대학생의 학업스트레스, 수면의 질과 우울과의 관계)

  • Jeon, Misoon
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.9
    • /
    • pp.58-64
    • /
    • 2021
  • This study identifies the relationship between academic stress, sleep quality and depression of nursing college students. The data was collected from 155 nursing students by the online survey. Data were analyzed using SPSS 18.0. As a result of analyzing the differences in academic stress, sleep quality, and depression according to general characteristics. It was confirmed that academic stress had a significant difference from physical health (F=6.326, p<.001) and mental health (F=11.630, p<.001). Sleep quality was different from physical health (F=8.834, p<.001), and depression was found to be different from physical health (F=9.619, p<.001) and mental health (F=28.625, p<.001). The results of analyzing the correlation between academic stress, sleep quality, and depression were found to have a positive correlation between academic stress and depression (r=.242, p<.01). Therefore, identifying the relationship between academic stress, sleep quality and depression among nursing college students is necessary to devise a plan to maintain and improve their physical and mental health

Optimum Design of Packaging Container for Bulk Materials(I)-Algorithm Development (벌크화물용 포장용기의 최적 설계(I)-알고리즘 개발)

  • Park, Jong-Min;Kwon, Soon-Goo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.6 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • In optimum design of packaging container for bulk materials, minimum board area, compression performance and distribution efficiency must be considered. In this study, mathematical models for minimum board area (RMA), compression strength (CS) and maximum compression strength per unit board area (MCSA) of container as algorithm for optimum design of packaging conatiner for bulk materials were developed as follows : RMA=f(V,D), ${\alpha}_{RMA}=f(V,D)$, MCSA=f(V,D), and ${\alpha}_{MCSA}=f(V,D)$. In order to develop these models, compression test according to various dimensions of container and response surface analysis for minimum board area, compression strength, and maximum compression strength per unit board area of container were carried out. In developed models, volume and depth of container were principal independent variables. Through the verified results for these models, optimum design of packaging container on the design conditions and limit conditions was possible. These models might be used in developing optimum design software of packaging container for bulk materials.

  • PDF

The Influence of Adolescents' Social Network(SNS) Addiction Tendency on Personal Relations (청소년의 SNS 중독경향성이 대인관계에 미치는 영향)

  • Park, Gong-Ju
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.8
    • /
    • pp.170-179
    • /
    • 2019
  • This study was narrative research study to find out the effect of adolescents' social media addiction tendencies on interpersonal relationships. This research data was collected from 250 middle high school students in G city, Gyeongnam and collected data was analyzed with t-test, ANOVA, Pearson's correlation, Multiple regression coefficient using SPSS 23.0 program. SNS addiction tendency scores according to general characteristics of adolescents were gender (t= -2.25, p = .011), duration of SNS use (F= 3.15, p= .015), average usage time (F= 15.87, p=. 001), SNS media (F= 3.12, p= .027), and SNS media usage time (F= 6.58, p= .001) were statistically significant. As a result of verifying the correlation of main variables, addiction tendency of SNS had statistically significant static correlation with interpersonal relationships. Influencing factors of interpersonal relations were Addiction tendency of SNS(${\beta}=-.64$, p=.<001) Interpersonal relationship explained 37% of the total variability.

Very Efficient Nucleophilic Aromatic Fluorination Reaction in Molten Salts: A Mechanistic Study

  • Jang, Sung-Woo;Park, Sung-Woo;Lee, Byoung-Se;Chi, Dae-Yoon;Song, Choong-Eui;Lee, Sung-Yul
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.881-884
    • /
    • 2012
  • We report a quantum chemical study of an extremely efficient nucleophilic aromatic fluorination in molten salts. We describe that the mechanism involves solvent anion interacting with the ion pair nucleophile $M^+F^-$(M = Na, K, Rb, Cs) to accelerate the reaction. We show that our proposed mechanism may well explain the excellent efficiency of molten salts for SNAr reactions, the relative efficacy of the metal cations, and also the observed large difference in rate constants in two molten salts $(n-C_4H_9)_4N^+\;CX_3SO_3^-$, (X=H, F) with slightly different sidechain ($-CH_3$ vs. $-CF_3$).

Characteristic Improvements of Organic Light Emitting Diodes By Using Co-Evaporated Cathodes

  • Kwak, Y.H.;Lee, Y.S.;Park, J.H.;Choi, Jong-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.710-713
    • /
    • 2002
  • In order to improve the power efficiency of multi-layer organic light emitting diodes (OLEDs), electron injection into ETL(electron transport layer) from cathode at the interface between ETL and cathode was enhanced by interposing a proper electron injection layer at the interface. The HTL(hole transport layer) and ETL materials used were N, N'diphenyl- N, N' - bis(3-methylphenyl-1, 1'- biphenyl - 4, 4 'diamine (TPD) and tris (8-hydroxyquinoline) aluminum ($Alq_3$) respectively. Cathodes using co-evaporated Al-CsF, Al-KF, and Al-NaF composites are adopted to enhance the electrical and optical properties of OLEDs. OLEDs with alkaline metal-doped cathode show a luminance of as high as 35,000 cd/$m^2$, and external quantum efficiency about 1.35 %. In addition, they show higher power efficiency at all bias conditions and good reproducibility.

  • PDF

Feasibility Study on Development of an Underwater Beta-ray Monitoring Sensor (수중 내 베타선 모니터링 센서 개발을 위한 기초연구)

  • Park, Hye Min;Joo, Koan Sik
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.333-336
    • /
    • 2016
  • In this study, a beta monitoring sensor was developed as a part of basic research for quantitative beta monitoring underwater, and its performance was evaluated using a calibration source. A beta detection sensor was manufactured by using SiPM(silicon photomultiplier) and $CaF_2$:Eu, YAG:Ce, YAP:Ce scintillator. A large-area light guide was introduced to improve beta-ray detection efficiency. As calibration sources, the Beta source $^{90}Sr$, which is the main fission product of a nuclear accident, and the gamma source $^{137}Cs$ are used. In the performance evaluation, it is confirmed that scintillator $CaF_2:Eu$ gives the highest beta-ray detection response. Compared to gamma ray, beta-ray detection responsivity and detection efficiency are verified. Therefore, this study is expected to contribute to basic research in the development of an underwater beta-ray monitoring system.

Asymmetry of microwave transition signal in a Cs atomic beam frequency standard (광펌핑된 세슘빔원자시계에서 마이크로파 전이신호의 비대칭성)

  • 강훈수;김영기;정혜연;김재필;송석호;김필수;오차환;이호성
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.70-71
    • /
    • 2000
  • 세슘빔 공진기에서 세슘D$_2$ 전이선으로 광펌핑된 원자가 램지공진기에서 마이크로파의 주파수에 따른 초미세준위의 바닥상태간의 원자밀도 전이에 의한 형광 신호의 분포를 펌핑광의 세기에 따라 관측하였다. 펌핑광의 편광방향이 자기장에 나란한 $\pi$편광일 때 각 제만부준위의 마이크로파 전이 신호는 mF=0을 중심으로 $\pm$mF의 신호세기가 대칭적이었으나 펌핑광의 편광 방향이 자기장에 수직인 $\sigma$ $\pm$ 인 경우에는 비대칭적임을 확인하였다. 이것은 펌핑광의 주파수가 세슘빔 공진기에서의 세슘공진주파수에서 detuning이 있는 것에 의한 것으로 예상하였다. 이를 확인하기 위해 원자밀도행렬방정식으로 세슘빔공진기에서 마이크로파 전이신호를 계산하였다. 펌핑광의 세기와 편광방향, detuning에 따른 마이크로파 전이신호의 분포가 실험치와 잘 일치함을 알 수 있었다. 이 연구는 세슘빔 원자공진기에서 펌핑광의 주파수가 세슘공진주파수에 detuning된 정도를 관측할 수 있는 방법을 제시해 준다. (중략)

  • PDF

E-Safety Awareness of Saudi Youths: A Comparative Study and Recommendations

  • Alharbi, Nawaf F;Soh, Ben;AlZain, Mohammed A;Alharbi, Mawaddah F
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.11
    • /
    • pp.181-188
    • /
    • 2021
  • The use of the internet has become a basic need for many across the globe. The situation is very much the same for the youth in many countries like Saudi Arabia who have grown up surrounded and accessing the internet. This demographic, however, is at an increased risk of falling as victims to cybercrime because of a low level of technical awareness. This review looks at the level of technical awareness of internet use in 3 different countries which include the USA, South Africa, and New Zealand. The review will compare the situation in these nations with those in KSA. Based on the review and comparisons, recommendations are made for culturally and socially acceptable e-Safety awareness of Saudi youths.