• Title/Summary/Keyword: Cs-Coefficient

Search Result 211, Processing Time 0.031 seconds

Separation Behavior of Cs and Sr on the Various Zeolites (각종 제올라이트계에서의 Cs 및 Sr 분리특성)

  • Lee, Eil-Hee;Lee, Won-Kyung;Yoo, Jae-Hyung;Park, Hyun-Soo
    • Applied Chemistry for Engineering
    • /
    • v.4 no.4
    • /
    • pp.731-738
    • /
    • 1993
  • This study showed the adsorption behavior of Cs and Sr into the inorganic ion-exchanger zeolites such as 4A, 13X, AW300, AW500 and natural. It was found that the best type of zeolite is AW500 for Cs and 13X for Sr in terms of ion-exchange capacity. The temperature effect was also examined for the following systems : AW500-Cs, AW300-Cs, natural zeolite-Cs, 4A-Sr and 13X-Sr. Experiments showed that the effect of temperature on the ion-exchange capacity is negligible in all cases except for the systems of 4A-Sr and natural zeolite-Cs. The enhancement in the ion-exchange capacity for 4A-Sr would be caused by the Sr ion movement and the multilayer adsorption due to the heterogeneous characteristics of ion-exchange site. The distribution coefficient was increased with pH of the solution which is in equilibrium with zeolite particles. The values of $K_d$ in the systems of AW500-Cs and 4A-Sr were found to be about $10^3cm^3/g$ and $10^3{\sim}10^4cm^3/g$ respectively.

  • PDF

Chitosan-Cu-salen/Carbon Nano-Composite Based Electrode for the Enzyme-less Electrochemical Sensing of Hydrogen Peroxide

  • Jirimali, Harishchandra Digambar;Saravanakumar, Duraisamy;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.169-175
    • /
    • 2018
  • Cu-Salen complex was prepared and attached into chitosan (Cs) polymer backbone. Nanocomposite of the synthesized polymer was prepared with functionalized carbon nano-particles (Cs-Cu-sal/C) to modify the electrode surface. The surface morphology of (Cs-Cu-sal/C) nanocomposite film showed a homogeneous distribution of carbon nanoparticles within the polymeric matrix. The cyclic voltammogram of the modified electrode exhibited a redox behavior at -0.1 V vs. Ag/AgCl (3 M KCl) in 0.1 M PB (pH 7) and showed an excellent hydrogen peroxide reduction activity. The Cs-Cu-sal/C electrode displays a linear response from $5{\times}10^{-6}$ to $5{\times}10^{-4}M$, with a correlation coefficient of 0.993 and detection limit of $0.9{\mu}M$ (at S/N = 3). The sensitivity of the electrode was found to be $0.356{\mu}A\;{\mu}M^{-1}\;cm^{-2}$.

SEPARATION OF STRONTIUM AND CESIUM FROM TERNARY AND QUATERNARY LITHIUM CHLORIDE-POTASSIUM CHLORIDE SALTS VIA MELT CRYSTALLIZATION

  • WILLIAMS, AMMON N.;PACK, MICHAEL;PHONGIKAROON, SUPATHORN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.7
    • /
    • pp.867-874
    • /
    • 2015
  • Separation of cesium chloride (CsCl) and strontium chloride ($SrCl_2$) from the lithium chloride-potassium chloride (LiCl-KCl) salt was studied using a melt crystallization process similar to the reverse vertical Bridgeman growth technique. A ternary $SrCl_2-LiCl-KCl$ salt was explored at similar growth rates (1.8-5 mm/h) and compared with CsCl ternary results to identify similarities. Quaternary experiments were also conducted and compared with the ternary cases to identify trends and possible limitations to the separations process. In the ternary case, as much as 68% of the total salt could be recycled per batch process. In the quaternary experiments, separation of Cs and Sr was nearly identical at the slower rates; however, as the growth rate increased, $SrCl_2$ separated more easily than CsCl. The quaternary results show less separation and rate dependence than in both ternary cases. As an estimated result, only 51% of the total salt could be recycled per batch. Furthermore, two models have been explored to further understand the growth process and separation. A comparison of the experimental and modeling results reveals that the nonmixed model fits reasonably well with the ternary and quaternary data sets. A dimensional analysis was performed and a correlation was identified to semipredict the segregation coefficient.

Study of Composite Adsorbent Synthesis and Characterization for the Removal of Cs in the High-salt and High-radioactive Wastewater (고염/고방사성 폐액 내 Cs 제거를 위한 복합 흡착제 합성 및 특성 연구)

  • Kim, Jimin;Lee, Keun-Young;Kim, Kwang-Wook;Lee, Eil-Hee;Chung, Dong-Yong;Moon, Jei-Kwon;Hyun, Jae-Hyuk
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.1
    • /
    • pp.1-14
    • /
    • 2017
  • For the removal of cesium (Cs) from high radioactive/high salt-laden liquid waste, this study synthesized a highly efficient composite adsorbent (potassium cobalt ferrocyanide (PCFC)-loaded chabazite (CHA)) and evaluated its applicability. The composite adsorbent used CHA, which could accommodate Cs as well as other molecules, as a supporting material and was synthesized by immobilizing the PCFC in the pores of CHA through stepwise impregnation/precipitation with $CoCl_2$ and $K_4Fe(CN)_6$ solutions. When CHA, with average particle size of more than $10{\mu}m$, is used in synthesizing the composite adsorbent, the PCFC particles were immobilized in a stable form. Also, the physical stability of the composite adsorbent was improved by optimizing the washing methodology to increase the purity of the composite adsorbent during the synthesis. The composite adsorbent obtained from the optimal synthesis showed a high adsorption rate of Cs in both fresh water (salt-free condition) and seawater (high-salt condition), and had a relatively high value of distribution coefficient (larger than $10^4mL{\cdot}g^{-1}$) regardless of the salt concentration. Therefore, the composite adsorbent synthesized in this study is an optimized material considering both the high selectivity of PCFC on Cs and the physical stability of CHA. It is proved that this composite adsorbent can remove rapidly Cs contained in high radioactive/high salt-laden liquid waste with high efficiency.

Soil-to-Plant Transfer Coefficients of Mn-54, Co-6O, Zn-65 and Cs-137 for Rice, Soybean and Vegetalbles (벼, 콩 및 채소류에 대한 Mn-54, Co-60, Zn-65, Cs-137의 토양-작물체간 전이계수)

  • Choi, Yong-Ho;Kim, Kug-Chan;Lee, Chang-Woo;Lee, Kang-Suk;Lee, Jeong-Ho;Pak, Chan-Kirl;Cho, Yong-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.55-65
    • /
    • 1991
  • Soil-to-plant transfer coefficients of Mn-54, Co-60, Zn-65, and Cs-137 were estimated for the edible parts of the rice, soybean, lettuce, carrot, and squash grown in different soils by radiotracer uptake experiments using pot cultures. The transfer coefficients of radionuclides were in the order of Zn-65 > Mn-54 > Cs-137 > Co-60 in most of the cases studied. The coefficients for soybean were roughly an order of magnitude higher than those for rice. Among vegetables, lettuce mostly showed the highest value and squash, the lowest. In the strongly acidic soils, transfer coefficients were much higher than in the moderately acidic soils. From the data obtained. crop-specific transfer coefficients of the four nuclides were proposed for the use in Korean food-chain radiation dose assessment.

  • PDF

Inhibitory Actions of HERG Currents by the Immunosuppressant Drug Cyclosporin A

  • Lee, Seung-Ho;Hahn, Sang-June;Min, Gye-Sik;Kim, Ji-Mok;Jo, Su-Hyun;Choe, Han;Choi, Bok-Hee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.15 no.5
    • /
    • pp.291-297
    • /
    • 2011
  • The effect of cyclosporin A (CsA), an immunosuppressant, on human ether-a-go-go-related gene (HERG) channel as it is expressed in human embryonic kidney cells was studied using a whole-cell, patch-clamp technique. CsA inhibited the HERG channel in a concentration-dependent manner, with an $IC_{50}$ value and a Hill coefficient of $3.17{\mu}m$ and 0.89, respectively. Pretreatment with cypermethrine, a calcineurin inhibitor, had no effect on the CsA-induced inhibition of the HERG channel. The CsA-induced inhibition of HERG channels was voltage-dependent, with a steep increase over the voltage range of the channel opening. However, the inhibition exhibited voltage independence over the voltage range of fully activated channels. CsA blocked the HERG channels predominantly in the open and inactivated states rather than in the closed state. Results of the present study suggest that CsA acts directly on the HERG channel as an open-channel blocker, and it acts independently of its effect on calcineurin activity.

Quantitative Differences between X-Ray CT-Based and $^{137}Cs$-Based Attenuation Correction in Philips Gemini PET/CT (GEMINI PET/CT의 X-ray CT, $^{137}Cs$ 기반 511 keV 광자 감쇠계수의 정량적 차이)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Park, Eun-Kyung;Kim, Jong-Hyo;Kim, Jae-Il;Lee, Hong-Jae;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.182-190
    • /
    • 2005
  • Purpose: There are differences between Standard Uptake Value (SUV) of CT attenuation corrected PET and that of $^{137}Cs$. Since various causes lead to difference of SUV, it is important to know what is the cause of these difference. Since only the X-ray CT and $^{137}Cs$ transmission data are used for the attenuation correction, in Philips GEMINI PET/CT scanner, proper transformation of these data into usable attenuation coefficients for 511 keV photon has to be ascertained. The aim of this study was to evaluate the accuracy in the CT measurement and compare the CT and $^{137}Cs$-based attenuation correction in this scanner. Methods: For all the experiments, CT was set to 40 keV (120 kVp) and 50 mAs. To evaluate the accuracy of the CT measurement, CT performance phantom was scanned and Hounsfield units (HU) for those regions were compared to the true values. For the comparison of CT and $^{137}Cs$-based attenuation corrections, transmission scans of the elliptical lung-spine-body phantom and electron density CT phantom composed of various components, such as water, bone, brain and adipose, were performed using CT and $^{137}Cs$. Transformed attenuation coefficients from these data were compared to each other and true 511 keV attenuation coefficient acquired using $^{68}Ge$ and ECAT EXACT 47 scanner. In addition, CT and $^{137}Cs$-derived attenuation coefficients and SUV values for $^{18}F$-FDG measured from the regions with normal and pathological uptake in patients' data were also compared. Results: HU of all the regions in CT performance phantom measured using GEMINI PET/CT were equivalent to the known true values. CT based attenuation coefficients were lower than those of $^{68}Ge$ about 10% in bony region of NEMA ECT phantom. Attenuation coefficients derived from $^{137}Cs$ data was slightly higher than those from CT data also in the images of electron density CT phantom and patients' body with electron density. However, the SUV values in attenuation corrected images using $^{137}Cs$ were lower than images corrected using CT. Percent difference between SUV values was about 15%. Conclusion: Although the HU measured using this scanner was accurate, accuracy in the conversion from CT data into the 511 keV attenuation coefficients was limited in the bony region. Discrepancy in the transformed attenuation coefficients and SUV values between CT and $^{137}Cs$-based data shown in this study suggests that further optimization of various parameters in data acquisition and processing would be necessary for this scanner.

Distributions of 137Cs and 90Sr in the Soil of Uljin, South Korea (울진토양에서의 137Cs 및 90Sr 분포)

  • Song, JiYeon;Kim, Wan;Maeng, Seongjin;Lee, Sang Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.49-55
    • /
    • 2016
  • Background: For the purpose of baseline data collection and enhancement of environmental monitoring the distribution studies of $^{137}Cs$ and $^{90}Sr$ in the soil of Uljin province was performed and the relation between surface soil activities and soil properties (pH, TOC and median of the surface soil) was analyzed. Materials and Methods: For 14 spots within 10 km from the NPP surface soil samples were collected and soils for depth profile were sampled for 3 spots in April 2011. Using ${\gamma}$-ray spectrometry with HPGe detector, the concentrations of $^{137}Cs$ were determined and the concentrations of $^{90}Sr$ were measured by counting ${\beta}$-activity of $^{90}Y$ (in equilibrium with $^{90}Sr$) in a gas flow proportional counter. Results and Discussion: The concentration ranges of $^{137}Cs$ and $^{90}Sr$ were $<0.479-39.6Bq{\cdot}(kg-dry)^{-1}$ (avg. $7.51Bq{\cdot}(kg-dry)^{-1}$) and $0.209-1.85Bq{\cdot}(kg-dry)^{-1}$ (avg. $0.74Bq{\cdot}(kg-dry)^{-1}$) which were similar to the reported values from other regions in Korea. The activity ratio of $^{137}Cs$ to $^{90}Sr$ in surface soils was around 9.67, which is much bigger than the initial value of 1.75 for worldwide fallouts because of faster downward movement of $^{90}Sr$ after fallout than that of $^{137}Cs$. For depth profile studies soils were collected down to 40 cm depth for the locations of Deokgu, Hujeong and Maehwa. The $^{137}Cs$ concentration distribution of the first two showed maximum values at top soils and decreased rapidly in exponential manner, while $^{90}Sr$ showed two local maximum values for soils near top and about 30 cm depth. Through linear fittings between the $^{137}Cs$ and $^{90}Sr$ concentrations of surface soil and pH, TOC and median of the surface soil, the only probable relationship obtained was between $^{137}Cs$ and TOC (determination coefficient $R^2=0.6$). Conclusion: The concentration ranges of $^{137}Cs$ and $^{90}Sr$ in Uljin were similar to the reported values from other regions in Korea. The only probable relationship obtained between activities and soil properties was between $^{137}Cs$ and TOC.

Derivation of relationship between cross-site correlation among flows and among estimators of L-moments for GEV and GLO distribution (GEV와 GLO 분포의 유출량 교차상관과 L-moment 추정값의 교차상관의 관계 유도)

  • Jeong, Dae-Il;Stedinger, Jery R.
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.321-325
    • /
    • 2007
  • 3개의 매개변수(location, scale, shape)로 이루어진 GEV와 GLO 분포는, 미국의 공식적인 홍수빈도 분포인 Log Pearson Type III와 함께 수문분야에서 중요한 위치를 차지하고 있다. 본 연구에서는 Monte Carlo 실험을 이용하여 GEV와 GLO 분포에서 서로 다른 두 지점의 유출량 자료를 생성하여 L-CV(L-moment Coefficient of Variation; $\tau_2$)와 L-CS(L-moment Coefficient of Skewness; $\tau_3$)를 추정하였으며, L-moment 추정값들 간의 교차상관$(\tau_2-\tau_2,\;\tau_3-\tau_3,\;\tau_2-\tau_3)$과 유출량 자료간의 교차상관의 관계를 Simple Power 함수를 이용하여 유도하였다. 실험 과정에서 GEV와 GLO 분포가 비현실적인 음수 유출량을 생성하여, 실험 결과에 큰 영향이 있음을 확인하여, 두 분포에서 생성된 유출량 자료에서 음수값을 제외한 GEV+와 GLO+ 분포를 이용하여 관계식을 유도하고 이를 GEV와 GLO 분포의 결과와도 비교하였다. 본 연구에서 도출된 관계식은 향후 Generalized Least Square 회귀식을 이용하여 홍수분포의 지역 매개변수를 추정하기 위해 활용성이 클 것으로 기대한다.

  • PDF

Molecular Dynamics Study of the Self-Diffusion Coefficient and Velocity Autocorrelation Function of a Polymer Molecule in Solution

  • Kang, Hong-Seok;Lee, Young-Seek;Ree, Tai-kyue
    • Bulletin of the Korean Chemical Society
    • /
    • v.4 no.5
    • /
    • pp.223-227
    • /
    • 1983
  • A molecular dynamic computer experiment was performed on a system of 108 particles composed of a single polymer chain and solvent molecules. The state considered was in the immediate neighborhood of the triple point of the system. The polymer itself is an analog of a freely jointed chain. The Lennard-Jones potential was used to represent the interactions between all particles except for that between the chain elements forming a bond in the polymer chain, for which the interaction was expressed by a harmonic potential. The self-diffusion coefficient and velocity autocorrelation function (VACF) of a polymer were calculated at various chain lengths $N_p$, and various interaction strengths between solvent molecules and a polymer chain element. For self-diffusion coefficients D, the Einstein relation holds good; as chain length $N_p$ increases the D value decreases, and D also decreases as ${\varepsilon}_{cs}$ (the interaction parameter between the chain element and solvent molecules) increases. The relaxation time of velocity autocorrelation decreases as ${\varepsilon}_{cs}$ increases, and it is constant for various chain lengths. The diffusion coefficients in various conditions reveal that our systems are in a free draining limit as is well known from the behavior of low molecular weight polymers, this also agrees with the Kirkwood-Riesman theory.