• Title/Summary/Keyword: Cs-137 조사기

Search Result 35, Processing Time 0.022 seconds

Determination of TRS-398 Quality Factors for Cs-137 Gamma Rays in Reference Dosimetry (Cs-137 감마선의 선량측정을 위한 TRS-398 선질인자 결정에 관한 연구)

  • Kang, Sang Koo;Rhee, Dong Joo;Kang, Yeong Rok;Kim, Jeung Kee;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.123-127
    • /
    • 2014
  • The Cs-137 irradiator is widely used to irradiate biological samples for radiobiological research. To obtain the accurate outcomes, correct measurements of the delivered absorbed dose to a sample is important. The IAEA protocols such as TRS-277 and TRS-398 were recommended for the Cs-137 reference dosimetry. However in TRS-398 protocol, currently known as the most practical dosimetry protocol, the quality factor ($k_{Q,Q_0}$) for Cs-137 gamma rays is not suggested. Therefore, the use of TRS-398 protocol is currently unavailable for the Cs-137 dosimetry directly. The calculation method previously introduced for high energy photon beams in radiotherapy was used for deriving the Cs-137 beam qualities ($k_{Q,Q_0}$) for the 15 commercially available farmer type ionization chambers in this study. In conclusion, $k_{Q,Q_0}$ values were ranged from 0.998 to 1.002 for Cs-137 gamma rays. These results can be used as the reference and dosimeter calibrations for Cs-137 gamma rays in the future radiobiological researches.

Reference Dosimetry and Calibration of Glass Dosimeters for Cs-137 Gamma-rays (연구용 세슘-137 조사기에 대한 흡수선량 측정과 유리선량계 교정에 관한 연구)

  • Moon, Young Min;Rhee, Dong Joo;Kim, Jung Ki;Kang, Yeong-Rok;Lee, Man Woo;Lim, Heuijin;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.140-144
    • /
    • 2013
  • In this research, the glass dosimeter was calibrated to measure the standard absorbed dose of the Cs-137 irradiator and absorbed dose in a biological sample. Absorbed dose in water for Cs-137 gamma ray was determined by the IAEA TRS-277 protocol. The PTW-TM30013 ion chamber and the PTW-TM41023 water phantom were utilized for measuring absorbed dose and the value was compared with the reading from DoseAce GD-302M glass dosimeter from Asahi Techno Glass Corporation for its calibration. The uncertainty of measurement ($1{\sigma}$) of the calibrated glass dosimeter was 2.7% and this result would be applied to improve the accuracy in measurement of absorbed dose in a biological sample.

Survey Study on Radioactivity of Domestic Fishery Product (국내 시중 유통 수산물에 대한 방사능 농도 조사)

  • Kim, Chang-Jong;Lim, Chung-seop;Lee, Wanno;Jang, Mee;Ji, Young-Yong;Chung, Kun-Ho;Kang, and Mun-Ja
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.6
    • /
    • pp.789-792
    • /
    • 2015
  • Samples of fishery products were tested for radioactivity by using the intake frequency data from Korea Health Statistics. The radioactivity of $^{40}K$, $^{137}Cs$, $^{134}Cs$, and $^{131}I$ was analyzed using gamma spectrometry with a simplified sample pre-treatment procedure. The radioactivity range for $^{40}K$ was 21.9-3050 Bq/kg, whereas the radioactivities of $^{137}Cs$, $^{134}Cs$, and $^{131}I$ were under minimum detectable activity which were in the range of 0.140-1.97, 0.0900-1.89 and 0.124-1.94 Bq/kg, respectively, for the three species. The results suggest that the Fukushima accident did not have a significant impact on domestic fishery products, which were analyzed during the period from 2013 to 2015. Additionally, there seemed to be no significant impact of additional exposure dose by the analyzed radionuclides.

A Study on the Fabrication of CsI(T1) Radiation Sensor and its Spectroscopic Characteristics (CsI(T1) 방사선센서의 제작 및 분광특성 연구)

  • 권수일;신동호
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.44-50
    • /
    • 2002
  • CsI(T1) single crystal was grown in a Bridgman growing apparatus, which has the diameter of 11 mm and the mole ratio of 0.001 mol%. Radiation sensors were made with CsITl)crystal and two photodiodes, and measured spectroscopic characteristics and linearity for gamma-ray and X-ray. The energy resolution of CsI(T1) radiation sensor has been measured with $^{22}$ Na, $^{137}$ Cs and $^{60}$ Co gamma standard sources. Also output linearity of CsITl) sensor was measured for diagnostic radiation region. The energy resolutions of CsI(T1) radiation sensor for 0.511MeV gamma-ray from Na-22 source, 0.662MeV from Cs-137 source, and 1.17MeV and 1.332MeV from Co-60 source were 13.2%, 8.3%, 6.7%, and 5.1% respectively. Also the output linearity up to 80mAs current for 60kVp, 80kvp, 100kVp, 120kVp tube voltages has been studied.

  • PDF

Developement of Radiation Measuring System using Wireless Communication (무선통신을 이용한 방사선측정 시스템 개발)

  • Lee, Bong-Jae;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.85-95
    • /
    • 1995
  • Radiation measuring system using wireless communication method with single channel has been diveloped and tested. In this system, radiation signals from GM tube are transformed into digital pulses in pulse processing circuit and modulated in FSK (frequency shift keying) circuit for digital communication and then wirelessly transmitted to a receiving unit. The digital pulses received are then demodulated in FSK circuit and converted into radiation dose/dose rate in the data acquisition unit to display on the screen of a personal computer. The performance of this system was evaluated by using both a pulse generator and a standard radiation source(Cs-137). In both cases, digital pulses with 5V were observed in pulse processing circuit without distortion of their shape through wireless communication system. The experimental results of radiation measurement by this system after several test-irradiation of GM detector to a standard radiation source(Cs-137), showed good agreement with irradiation dose rate within 10% difference, and proved that this system could be effectively utillized as radiation measuring instrument. It is expected that this wireless radiation measuring system developed for the first time in Korea, can be used as a radiation monitor as well as a personal dosimeter if we can further improve this system to adopt wireless multichannel communication system.

  • PDF

Evaluation of Dose Distribution Using a Radiophotoluminescence Glass Dosimeter in Biobeam8000 Gamma Irradiation Device (유리선량계를 이용한 Biobeam8000 감마선 조사장치의 선량평가)

  • Shin, Sang-Hun;Lee, Sung-Hyun;Son, Ki-Hong;Lee, Hyun-Ho;Kim, Kum-Bae;Jung, Hai-Jo;Ji, Young-Hoon
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.198-205
    • /
    • 2011
  • Gamma irradiator is widely used for cell, animal experiment, irradiation for blood, dose measurement, and education. Biobeam8000 gamma irradiator (STS Steuerungstechnik &. Strahlenschutz GmbH, Braunschweig, Germany, Cs137, 81.4 TBq) that KIRAMS (Korea Institute of Radiological and Medical Science) has is a irradiation device that enables to be used in large-capacity of 7.5 L and extensive area. Cs-137 source moves range of 24 cm back-and-forth in a regular cycle in beaker for uniform irradiation and a beaker that puts a specimen like existing radiation irradiator such as Gammacell3000 rotates $360^{\circ}$ during irradiation. Precise dose information according to the location of radiation source would be needed because of the movement of radiation source, whereas radiation could be uniformly irradiated in comparison with existing gamma irradiator. In this study, dose distribution of the inside beaker located in Biomeam8000 gamma irradiator was measured using glass dosimeter, and dose evaluation and distribution regarding dose linearity and dose reproducibility were implemented based on measurement results. This aims to show guideline for efficient use of irradiator based on measurement result when doing experiment or radiation exposure.

Geostatistical Interpretation of Cs-137 and K-40 Result of the Lithosphere in the Vicinity of Youngkwang Nuclear Power Plant (지구통계학적 방법에 의한 영광원전주변 토층내 Cs-137 및 K-40 측정 결과의 해석)

  • 김경웅;이재석;문승현;박철승;고일원;고은정;조병옥;정철영;전수열
    • Economic and Environmental Geology
    • /
    • v.35 no.6
    • /
    • pp.545-552
    • /
    • 2002
  • In order to investigate the influence of nuclear power plant operation on its nearby environment, soil, stream and marine sediment samples were collected in the vicinity of the Youngkwang Nuclear Power Plant in Korea, and analyzed for artificial and natural radionuclide radioactivity. From the analytical result, Cs-137 was detected in most soil samples. but it may have been derived fiom past nuclear weapon tests because Cs-134 having short half-live was not detected. The radioactivities of Cs-137 in the sediment samples were also detected which are within the normal range in the sediments based upon the published literature between 1997 and 1999. For the quality control of radioactivity analysis of environmental samples, sets of marine sediments in the Gamami area were analyzed using two HPGe Gamma-ray Spectroscopes (30% and 45%) according to the geostatistical sampling strategy, and Cs-137 and K-40 results were interpreted by analysis of variance (ANOVA). In the two-way ANOVA, variances derived from the geochemical variation were significant, but errors from sampling and analytical procedures are negligible. In conclusion. all the radioanalytical procedures of this study including sampling are validated to be acceptable.

Effects of Temperature on the Uptake and Retention of Cesium-137 by the Clam Cyclina sinensis (가무락조개에 의한 세슘-137 의 농축(濃縮)과 잔류(殘留)에 미치는 온도(溫度)의 영향)

  • Yoo, Byung-Sun;Lee, Jeong-Ho;Lee, Su-Rae
    • Korean Journal of Environmental Agriculture
    • /
    • v.2 no.1
    • /
    • pp.24-29
    • /
    • 1983
  • The effects of temperature on the uptake of $^{137}Cs$ from seawater and on the retention after its uptake by the clam Cycling sinensis was investigated under laboratory conditions. The clams exhibited a greater bioaccumulation of $^{137}Cs$ in $25^{\circ}C$-acclimated animals than those acclimated at $15^{\circ}C$. The viscera of the clams reached the highest bioconcentration factor after 14 days uptake from seawater, but the tissue distribution pattern of $^{137}Cs$ was little influenced, if any, by the uptake temperature. The uptake rate slightly decreased with an increase of temperature in order of $10^{\circ}C$. The radionuclide accumulated in clams was released again in a radionuclide-free seawater according to a two-exponential compartment model. A temperature increase of $10^{\circ}C$ reduced the biological half-life of the long-lived component with a factor of about two, whereas it caused no change in the short-lived component.

  • PDF

Soil-to-Plant Transfer Factors of $^{137}Cs$ in Paddy and Upland Fields of Korea (한국의 논과 밭에서 $^{137}Cs$ 의 토양-작물체 전이계수)

  • Choi, Yong-Ho;Lim, Kwang-Muk;Lee, Myung-Ho;Choi, Geun-Sik;Chung, Kyu-Hoi
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.2
    • /
    • pp.164-168
    • /
    • 1999
  • For investigating transfer factors of $^{137}Cs$ in the arable land of Korea, mature crop plants and topsoils were collected from paddy and upland fields located at 33 areas of the country and $^{137}Cs$ concentrations were measured by ${\gamma}-spectrometry$. The $^{137}Cs$ concentrations in soil were in the range of $0.7{\sim}17.7$ Bq/kg-dry in the paddy fields and $1.2{\sim}27.8$ Bq/kg-dry in the upland fields. The $^{137}Cs$concentrations in hulled seed, detected for 12 areas only, were in the range of $0.019{\sim}0.111$ Bq/kg-dry and those in Chinese cabbage, detected also for 12 areas only, were in the range of $0.012{\sim}0.066$ Bq/kg-fresh. Soil-to-plant transfer factors of $^{137}Cs$ were in the range of $1.2{\times}10^{-3}{\sim}1.1{\times}10^{-2}$ for hulled seed and $6.8{\times}10^{-4}{\sim}1.7{\times}10^{-2}$ for Chinese cabbage. Inboth plant stuffs, the factor tended to decrease with increasing soil organic matter or cation exchange capacity and, in hulled seed, it tended to increase with increasing soil clay content. No statistical significance was, however, found in all those relationships. Present results can be utilized for estimating radiation risk resulting from the food consumption by Korean people and deciding agronomical counter-measures at the time of an nuclear accident.

  • PDF