• Title/Summary/Keyword: Cryogenic characteristics

Search Result 304, Processing Time 0.025 seconds

Breakdown Characteristics of Insulation Materials for a Termination of Power Transmission Class HTS Cable

  • Kwag Dong-Soon;Cheon Hyeon-Gweon;Choi Jae-Hyeong;Kim Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.2
    • /
    • pp.37-42
    • /
    • 2006
  • A research on several characteristics such as volume breakdown and surface discharge of insulators for a termination of power transmission class HTS cable was performed. We investigated the surface discharge of glass fiber reinforced plastic (GFRP) under air, cryogenic nitrogen gas and nitrogen gas media. The breakdown characteristics of these media were studied. Experimental results revealed that flashover voltage greatly depends on pressure, temperature, the kinds of insulating media and voltages, but it is slightly affected by shape and material of electrode. The breakdown voltage of liquid nitrogen, cryogenic nitrogen gas and nitrogen gas deeply depends on the shape and dimension of electrode, kinds of voltages and pressure. Moreover, the breakdown voltage of cryogenic nitrogen gas and flashover voltage of GFRP in the cryogenic nitrogen gas is also influenced by temperature and vapour-mist density of the gas.

Effect of Packing Materials of Frozen Boar Semen on Sperm Characteristics and Reproductive Performance (동결정액 포장방법이 돼지정액의 성상 및 번식성적에 미치는 영향)

  • 김인철;이장희;김현종;이성호;박창식
    • Korean Journal of Animal Reproduction
    • /
    • v.26 no.2
    • /
    • pp.119-124
    • /
    • 2002
  • This study was carried out to investigate the effects of packing materials of frozen boar semen to improve reproductive performance efficiency in pig. Boars were raised at Swine Artificial Insemination Center in National Livestock Research Institute, Sunghwan, Chungnam, Korea. We compared packing protocols for frozen boar semen among 5$m\ell$ maxi-straw, 5$m\ell$ cryogenic-vial, and aluminum-pack. Cryogenic-vial packing material showed similar sperm characteristics compared with maxi-straw packing material when the sperm was frozen above 15cm from liquid nitrogen and thawed at 52$^{\circ}C$ for 190 seconds. We investigated different thawing times to find out the optimal condition of freezing and thawing protocol with cryogenic-vial. Freezing above 15cm from liquid nitrogen and thawing at 52$^{\circ}C$ for 190 seconds were the optimal protocol compared with 120 and 150 seconds. However, normal acrosome rates did not show any differences among thawing times. Post-thawing results of maxi-straw in water at 52$^{\circ}C$ for 45 seconds had better total motility and curve linear velocity than those of cryogenic-vial in water 52$^{\circ}C$ for 190 seconds. However, there were no differences on straightness and normal apical ridge of sperm between maxi-straw and cryogenic vial. Non-return rate, farrowing rate and litter size of sows inseminated with frozen boar semen of commercial farms were higher in the maxi-straw than cryogenic-vial, but there were no significant differences between maxi-straw and cryogenic-vial. In conclusion, there were no significant differences between maxi-straw and cryogenic-vial and so, we may replace cryogenic-vial packing method instead of maxi-straw packing method by improvement of freezing and thawing rate.

A Study of Mechanical Characteristics at Room/Cryogenic Temperature of Powder Insulation Materials Applied to Type C Fuel Tank (Type C 연료탱크에 적용되는 분말형 단열 소재의 상온/극저온 기계적 특성에 관한 연구)

  • Kim, Tae-Wook;Oh, Jae-Won;Seo, Young-Kyun;Han, Seong-Jong;Lee, Jae-Myung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.787-793
    • /
    • 2021
  • The global demand for Liquefied Natural Gas(LNG) continues to increase and is facing a big cycle. To keep pace with the increase in international demand for LNG, the demand for LNG fueled ships is also increasing. Since LNG fuel tanks are operated in a cryogenic environment, insulation technology is very important, and although there are various types of insulation applied to Type C tanks, multi-layer insulation and vacuum insulation are typically applied. Powder insulation materials are widely used for storage and transportation of cryogenic liquids in tanks with such a complex insulation structure. In this study, compression tests at room and cryogenic temperature were performed on closed perlite, glass bubble, and fumed silica, which are representative powder insulation material candidates. Finally, the applicability to the Type C fuel tank was reviewed by analyzing the experimental results of this study.

Fluorescent and Luminescent Proteins Derived from Marine Organisms: Functions and Applications

  • Sehyeok, Im;Jisub, Hwang;Hackwon, Do;Bo-Mi, Kim;Sung Gu, Lee;Jun Hyuck, Lee
    • Journal of Marine Life Science
    • /
    • v.7 no.2
    • /
    • pp.74-85
    • /
    • 2022
  • Organisms constituting a large proportion of marine ecosystems, ranging from bacteria to fish, exhibit fluorescence and bioluminescence. A variety of marine organisms utilize these biochemically generated light sources for feeding, reproduction, communication, and defense. Since the discovery of green fluorescent protein and the luciferin-luciferase system more than a century ago, numerous studies have been conducted to characterize their function and regulatory mechanism. The unique properties of fluorescent and bioluminescent proteins offer great potential for their use in a broad range of applications. This short review briefly describes the functions and characteristics of fluorescent and bioluminescent proteins, in addition to summarizing the recent status of their applications.

Design and manufacture of horn lens antennas of 80 GHz MM wave FMCW radar for cryogenic fluids level measurement

  • Jeon, S.M.;Mun, J.M.;Lee, S.C.;Sim, K.D.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.1
    • /
    • pp.29-33
    • /
    • 2022
  • Recently, development of a cryogenic fluids storage tank for storing or transporting liquid hydrogen is actively in progress. In cryogenic fluids storage tanks, hydrogen evaporates due to the extreme temperature difference inside and outside the tank. As the mass of the cryogenic fluids changes with continuous vaporization, the fluids level also changes. Therefore, there is need for a method of accurately measuring the level change in the storage tank. In the case of general cryogenic fluids, it is difficult to accurately measure the level because the dielectric constant is very low. As a method of measuring cryogenic fluids level with low dielectric constant, it can be used an Millimeter wave (MM wave) FMCW radar sensor. However, the signal sensitivity is very weak and the level accuracy is poor. In this paper, the signal sensitivity is improved by designing the horn lens antenna of the existing 80 GHz FMCW radar sensor. Horn lens antenna is fabricated by FDM/SLA type 3D printer according to horn and lens characteristics. The horn is used to increase the signal gain and the lens improves the signal straightness. This makes it possible to measure the level of cryogenic fluids with a low dielectric constant.

Study of thermoacoustic oscillations in half-open tubes for saturated superfluid helium

  • Wang, Xianjin;Niu, Xiaofei;Bai, Feng;Zhang, Junhui;Chen, Shuping
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.68-73
    • /
    • 2022
  • Thermoacoustic oscillations (TAOs) are spontaneous pressure oscillations frequently seen in hydrogen or helium cryogenic systems. Half-open tubes connected to cryogenic fluid with a closed room temperature end have a high potential for oscillation generation. Thermoacoustic oscillations will result in significant pressure fluctuations and additional heat load, endangering the security and stability of the cryogenic system. The goal of this paper is to investigate TAOs in superfluid helium using both theoretical and experimental methods. Five half-open tubes with varied typical inner diameters inserted into superfluid helium were installed in a test cryostat. The onset characteristics of thermoacoustic oscillations were presented and studied. The effect of temperature profile was discussed. Finally, a simple eliminating method was introduced.

Flow Characteristics of Cryogenic Butterfly Valve for LNG Carrier (Part 1 : CFD Analysis and its Comparison with Experimentation) (LNG선용 버터플라이밸브의 유동특성에 관한 연구 (제1부 : CFD해석과 실험결과의 비교))

  • Kim, Sang-Wan;Choi, Young-Do;Kim, Jung-Hwan;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.2
    • /
    • pp.13-19
    • /
    • 2008
  • Butterfly valves are widely used as control valves for industrial process. For the definition of optimum configuration of the valve, wide range of related studies has been actively conducted in the case of working fluids of water or air under the normal temperature. Recently, internal flow and performance characteristics of cryogenic butterfly valve for LNG carrier take a growing interest in the field of research and development. Therefore, present study is aimed to investigate the internal flow and performance characteristics of the cryogenic butterfly valve because the study result for the valve can be hardly found at present. Part 1 of this paper describes the study result of a butterfly valve model under the condition of the normal temperature. Succeeding Part 2 of this paper will describe the internal flow characteristics of a cryogenic butterfly valve for LNG carrier. The results of Part 1 show that pressure loss coefficients and flow rate coefficients obtained by the present experiment and CFD analysis agree well each other. Moreover, internal flow visualization for the valve by CFD analysis and PIV measurement have revealed complicated flow patterns of the internal flow field in detail.

A Study on the Electrical and Mechanical Properties of AlN for Insulation of a Conduction-Cooled HTS SMES (전도냉각 고온초전도 SMES 절연용 AlN의 전기적 및 기계적 특성 연구)

  • Choi, J.H.;Kwag, D.S.;Cheon, H.G.;Min, C.H.;Kim, H.J.;Jung, S.Y.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.957-958
    • /
    • 2007
  • The conduction-cooled HTS SMES magnet is operated in cryogenic temperature. The insulation design at cryogenic temperature is an important element that should be established to accomplish miniaturization that is a big advantage of HTS SMES. However, the behaviors of insulators for cryogenic conditions in air or vacuum are virtually unknown. Therefore, we need active research and development of insulation concerning application of the conduction-cooled HTS SMES. Specially, this paper was studied about high vacuum and cryogenic temperature breakdown and flashover discharge characteristics between cryocooler and magnet-coil. The breakdown and surface flashover discharge characteristics were experimented at cryogenic temperature and vacuum. Also, we were experimented about mechanical properties of 4-point bending test. From the results, we confirmed that about research between cryocooler and magnet-coil established basic data in the insulation design.

  • PDF

Development of Cryogenic Radiopharmaceutical Transport System (초저온 방사성의약품 운송시스템 개발)

  • Eun-Ha Cho;Yoo-Hwang Lee
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.321-326
    • /
    • 2023
  • Radiopharmaceuticals that need to be transported in a low-temperature state must satisfy both radiation safety and proper temperature maintenance. However, an efficient transport system considering the characteristics of radiopharmaceuticals that require low temperature maintenance has not yet existed. In order to secure a transportation system for the safe and stable transportation of the radiopharmaceutical 131I mIBG, which requires transportation in cryogenic conditions, we have developed a transportation system that can maintain cryogenic conditions below -60℃ for 6 days while stably fixing the inner container. In addition, by applying a data logger that can simultaneously measure the temperature and the dose of radiation, safety and stability in the transportation process can be secured at the same time. The cryogenic transportation system for 131I mIBG will be applied to products currently being supplied, and we expect to dramatically improve the management of cold chain radioactive material transportation.

Evaluation of Cryogenic Fracture Characteristics on TIG Weldments of Superconducting Magnets Structural Steel by Small Punch Testing Method (소형펀치 시험법에 의한 초전도 마그넷 구조용강 TIG 용접부의 극저온 파괴특성 평가)

  • ;T. Hashida
    • Journal of Welding and Joining
    • /
    • v.14 no.5
    • /
    • pp.122-133
    • /
    • 1996
  • In order to evaluate the cryogenic fracture characteristics of structural steels for superconducting magnets of fusion reactor, small punch (SP) testing was performed on austenitic stainless steel (JN1 base metal) and its TIG weldments at 293K, 77K and 4K. The mechanical properties with respect to the extracted location of the weld metal, on the effects of welding heat cycle about base metal near fusion line in TIG weldments were investigated. The mechanical property of the weld metal in TIG weldments depends on distance from welding root, root region of weldments having the lowest mechanical property. The base metal near fusion line showed degradation of mechanical property caused by cyclic heating during the TIG welding. Based on the test results, HAZ was found to be up to 5mm from the fusion line. It is shown that SP testing is a useful tool to evaluate the mechanical properties with respect to the microstructures changes such as HAZ as well as weld metal in TIG weldments at cryogenic temperature.

  • PDF