• Title/Summary/Keyword: Crown diameters

Search Result 39, Processing Time 0.027 seconds

THE STUDY ON THE PREDICTION OF THE MESIODISTAL DIAMETERS OF UNERUPTED CANINES AND PREMOLARS IN KOREAN MALE AND FEMALE (미맹출 영구 견치 및 소구치 근원심 폭경 추정에 관한 연구)

  • Hwang, Min-Sung;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.115-124
    • /
    • 2002
  • The purpose of this study was to establish regression equations and probability charts for predicting the sum of mesiodistal crown diameters of unerupted unilateral canine and premolars from the sum of mesiodistal crown diameters of four mandibular incisors in Korean male and female. The plaster casts of 162 children(75 boys and 87 girls) among the contestees in 1994-2001 Healthy Dentition Contest in Seoul were measured. Sex differences are compared and the following results were obtained: 1. Bilateral comparison of sum of widths of permanent canine and premolars showed no significant differences for either sex(p>0.05). Sum of widths of permanent canine and premolars of male were significantly larger than that of female(p<0.01). 2. Regression equations for the prediction of sum of widths of permanent canine and premolars in each sex were as follows Male ${\Sigma}Maxillary$ 345 y= 10.45+0.53x Male ${\Sigma}Mandibular$ 345 : y= 10.07+0.51x Female ${\Sigma}Maxillary$ 345 : y=12.65+0.42x Female ${\Sigma}Mandibular$ 345 : y=11.70+0.42x Male+female ${\Sigma}Maxillary$ 345 y=11.01+0.50x Male+female ${\Sigma}Mandibular$ 345 : y=9.87+0.51x

  • PDF

A 3-dimensional Finite Element Analysis of Stress Distribution in the Supporting Bone by Diameters of Dental Implant Fixture (골유착성 치과 임플랜트 고정체 직경에 따른 지지골의 응력분포에 관한 삼차원 유한요소 분석적 연구)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.69-76
    • /
    • 2004
  • The objective of this finite element method study was to analyze the stress distribution induced on a supporting bone by 3.75mm, 4.0mm, 5.0mm diameter of dental implant fixture(13mm length). 3-dimensional finite element models of simplified gold alloy crown(7mm height) and dental implant structures(gold cylinder screw, gold cylinder, abutment screw, abutment, fixture and supporting bone(cortical bone, cancellous bone) designs were subjected to a simulated biting force of 100 N which was forced over occlusal plane of gold alloy crown vertically. Maximum von Mises stresses(MPa) under vertical loading were 9.693(3.75mm diameter of fixture), 8.885(4.0mm diameter of fixture), 6.301(5.0mm diameter of fixture) and the highest von Mises stresses of all models were concentrated in the surrounding crestal cortical bone. The wide diameter implant was the good choice for minimizing cortical bone-fixture interface stress.

  • PDF

A Retrospective Study of Sintered Porous-surfaced Dental Implants in Restoring the Edentulous Posterior Mandible: Up to Eight Years of Functioning (하악 구치부에 식립한 sintered porous surfaced implants의 후향적 다기관 연구)

  • Kim, Woo-Sung;An, Kyung-Mi;Sohn, Dong-Seok;Jung, Heui-Seung;Shin, Im-Hee
    • The Journal of the Korean dental association
    • /
    • v.47 no.12
    • /
    • pp.823-829
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the survival rate of sintered porous-surfaced implants placed in the edentulous posterior mandibles, in relation to implant length and diameter, crown-to-implant ratio, and types of prostheses, for a maximum of eight years of functioning. Material and Methods : The study group consisted of 43 partially edentulous patients who visited Catholic University Hospital of Daegu and one private dental clinic. A total of 122 sintered porous-surfaced implants n $Endopore^{(R)}$ (Inn ova Life Sciences, Toronto, Ontario, Canada) -- were placed in the edentulous posterior mandibles, Two diameter sizes (4.1 mm and 5.0 mm) and four lengths (5.0 mm, 7.0 mm, 9.0 mm, and 12.0 mm) were used. One hundred and three implants were splinted and 21 implants were nonsplinted. The survival rates of the implants in relation to length, diameter, crown-to-implant ratio, and types of prostheses were investigated. Statistical data were analyzed using SPSS Win.Ver 14.0 software with the Chi-square test. Results : The survival rate of the 4.1mm diameter implants was 100% and 91.2% for the 5.0mm diameter implants. The survival rates of the implants of differing diameters were found to be statistically different (p=0.005). The survival rates of both the 5.0mm and 7.0 mm length implants were 100%. The survival rate of the 9.0mm length implants was 97.9% and for the 12.0mm length implants was 95.1%. There was no statistical difference in survival rates for the differing lengths of implants. Of the 103 prostheses that were splinted, the survival rate was 98.0%. The survival rate of splinted prostheses was higher than that of the non-splinted prostheses, but was found to be not statistically different. There were no failed cases when the crown-to-implant ratio was under 1.0. When the crown-to-implant ratio was between 1.0 and 1.5, the failure rate of the implants was 6.7%. No failure was recorded with the ratio range of 1.5 to 2.0. Relative to the crown-to-implant ratio of 1.0, the failure rates were statistically different (p=0.048). Discussion and Conclusion : The cumulative survival rate of the porous-surfaced implants placed in the edentulous posterior mandibles was 97.5%. Short porous-surfaced implants showed satisfactory results after a maximum of nine years of functioning in the edentulous posterior mandibles.

  • PDF

Spacing and crowding of the primary dentition in Korean children - relationship to tooth sizes and dental arch dimension (한국인 아동의 유치열기의 특성 - 치아 치열궁의 관계)

  • Im, Dong-Hyuk;Kim, Tae-Woo;Nahm, Dong-Seok;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.84-90
    • /
    • 2006
  • The aims of this study were to investigate the prevalence of spaced, closed, and crowded primary dentitions by sex and arch in Korean children from Kanghwa, and to determine the frequency of the primate and developmental spaces. The differences in the mesiodistal crown diameters and the arch dimensions between the spaced, closed, and crowded primary dentitions were also evaluated. Dental casts of 102 preschool children (57 males and 45 females, aged $4{\sim}5$ years) were studied. The prevalence of spacing in the primary dentition was 63.2% In males and 57.8% in females. The frequency of spacing was greater in males than in females, and greater in the maxillary arch than in the mandibular arch. The crowns were significantly larger and the arches significantly narrower in closed and crowded dentitions than in those with spacing (p<0.05). The results showed that the prevalence of spacing was lower than that found in previous studies and the presence of spacing in the anterior region was related to the mesiodistal crown diameter and the intercanine width.

Finite Element Analysis of Stress Distribution on Supporting Bone of Cement Retained Implant by Oblique Loading (경사하중에 따른 시멘트 유지형 임플란트 지지골의 유한요소법 응력 분포)

  • Lee, Myung-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.9
    • /
    • pp.343-349
    • /
    • 2014
  • The dental osseointegration implant should be enough to endure occlusion load and it's required to have efficient design and use of implant to disperse the stress into bones properly. Solidworks as a finite element analysis program for modeling and analysis of stress distribution was used for the research. The simple crown model was designed on applying conjoined condition with tightening torque of 20 Ncm of a abutment screw between a cement retained implant abutment and a fixture. A $45^{\circ}$ oblique loading from lingual to buccal side on buccal cusps of crown and performed finite element analysis by 100 N of external load. The results by a analysis for stress distribution of supporting bones of fixture were as below. The von Mises stress was concentrated on the upper side of supporting compact bone regardless of the diameters and lengths of fixture, and the efficiency result of stress reduction was increase of fixture's diameter than it's length. Therefore, it's effective to use wider fixture as possible to the conditions of supporting jaw bone.

A Study on the Minimum Distance between Landscape Trees and Apartment Buildings (수목생육 조건을 고려한 조경수목과 아파트 건물의 최소 이격거리에 관한 연구)

  • Jang, Ha-Kyung;Ahn, Geun-Young;Lee, Eun-Heui
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.1 s.120
    • /
    • pp.1-8
    • /
    • 2007
  • The purpose of this study is to suggest the minimum distance needed between landscape trees and apartment buildings. in order for the trees to grow soundly and maintain constant growth. Therefore, this study investigated and analyzed the present conditions of the green-spaces contiguous to apartment buildings and the trees inside the apartment complex. The following general problems were identified : (1) the tree growth conditions, (2) the planting intervals, and (3) the planting methods in the apartment complexes. The method of this study was to survey areas, measure the trees and analyze the results. Ten apartment complexes located in Seoul were randomly selected for this study. To analyze the greens contiguous to the building of each apartment complex, the greens were divided into three types, including the front greens, the side greens, and the rear greens. The study surveyed the width of all contiguous greens and the distance from trees to my given building. Four representative sites were specifically investigated to measure the crown widths, heights, and diameters of the trees. These investigations were carried out over 3 months from August to December 2006. According to the results of the study, it was found that the greens are narrower in width and the more closer to a building. The study identified a correlation between the tree and the passage of time after the completion of construction of an apartment complex, showing that the malformation of the trees worsened as time passed. As a result of measuring the right crown and left crown width with the tree trunk as the center, a broad difference was found between coniform trees and trees that tend to branch out more. For example, the ratio of the width of the Acer palmatum is 1:6. However, the ratio of the Metasequoia glyptostroboide is 1:1.7. Based on the overall analysis, it was concluded that the maintained minimum width must be greater than one meter over the green space according to the 'Landscape Standard 2000'. However, that is only applicable to cases such as apartment buildings that present no obstacles. In conclusion having greens placed within one meter of width to a building is not an appropriate environment for the healthy growth of trees. To create sound green spaces, sustainable, long-term growth rate and size should be considered. It is necessary to prepare new standards for the computation of planting trees and the measurement of square landscapes. Wall greenery and shrubberies could be an alternative in the case of a narrow-width green space.

Influence of Physico.Chemical Properties of Root Substrates on the Growth of 'Maehyang' Strawberry Daughter Plants Produced by Bag Culture of Stock Plants (포트 충전용 상토의 물리.화학성이 플라스틱 백 재배를 통해 발생한 '매향' 딸기의 자묘 생육에 미치는 영향)

  • Choi, Jong-Myung;Park, Ji-Young;Ko, Kwan-Dal;Lee, Chi-Won W.
    • Korean Journal of Agricultural Science
    • /
    • v.37 no.2
    • /
    • pp.199-207
    • /
    • 2010
  • This research was conducted to determine the influence of physiological and chemical properties of root substrates on the growth of the daughter plants of 'Maehyang' strawberry produced by bag culture. The daughter plants produced by stock plants during bag culture were individually separated and grown in 10-cm diameter plastic pots containing six different formulations of root substrates: a) 50% peatmoss plus 50% vermiculite (5:5 by volume, A), b) 70% peatmoss plus 30% perlite (7:3, B), c) 70% coir dust plus 30% perlite (7:3, C), d) mixture of 35% coir dust, 35% peatmoss, and 30% perlite (3.5:3.5:3.0, D), e) mixture of 20% rice hull, 70% coir dust, and 10% perlite (2:7:1, E), and f) 30% rice hull plus 70% coir dust (30:70, F). The container capacity and air filled porosity of the growing medium varied greatly among the six substrate formulations evaluated. The substrates E and F had less container capacity and higher air-holding spaces than the rest of the formulations. Therefore, these two formulations (E and F) may cause a problem in water management during the production of healthy daughter plants. The substrate formulations A, B, and D retained higher nitrogen (N) concentrations than other formulations containing coir dust or rice hull. The substrate formulations E and F which contained rice hull had lower N, phosphorus (P), and potassium(K) concentrations than other substrate formulations containing coir. The quality of the daughter plants grown in all six different substrate formulations was good with the crown diameters at around 10 mm. Fresh weights of the daughter plants grown in substrate formulations A, C, and D were higher than those obtained from B, E, and F. Dry weights of the daughter plants showed a similar trend. The daughter plants having high fresh and dry weights and increased crown diameter are in demand by the industry. For this reason, the substrate formulations A, C and D can readily be used as potting mixes during the production of 'Maehyang' strawberry transplants utilizing the bag culture system.

STUDY ON THE TOOTH SIZE AND DENTAL ARCH OF THE KOREANS (한국인의 치열궁과 치아의 크기에 관한 연구)

  • Seo, Jeong-Hun
    • The Journal of the Korean dental association
    • /
    • v.10 no.3
    • /
    • pp.155-158
    • /
    • 1972
  • As a factor of dentistry, the form of the tooth especially the size plays an important part. And in orthodontics the relation between the tooth size, arch length and the basal arch is regarded important, and it is closely related to the extraction and retension probolem in treatment planning. The auther's study of the mesio-distal crown diameters of permanent teeth, width and length of the dental arch and basal arch from the cast of 50 men and 53 women who could be measured clerly, among 102 men and 107 women regarded as the normal occlusion showed the followings. 1. Table 1 and table 2 showed the measurement of the mesio-distal maximum width of the permanent teeth, width and length of the dental arch and basal arch of the upper and lower dentitions. 2. Men's mesio-distal width of the teeth, arch length and arch width of the upper and the lower dentition, basal arch width and basal arch length are larger than those of wonen's 3. We compared the Koreans with the American white. Upper central incisors, upper first molars and lower second premolars of the latter were larger than those of the former. And the Koreans's rest tooth of the rest were comparatively larger.

  • PDF

Wood Quality of Populus nigra × maxmowiczii. (I) - Variation of Bulk Density, Wood Fiber Dimension, Microfibril Angle, and Number of Leaf Knot within Stem - (양황철나무의 재질(材質) (I) 용적밀도수(容積密度數), 목섬유(木纖維)치수 및 잎옹이 분포수(分布數)의 간내변수(幹內變數) -)

  • Park, Sang-Jin;Kang, Sun-Gu;Lee, Ki-Yeong;Jo, Jae-Myeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.26-33
    • /
    • 1990
  • To study the wood quality factors of Populus nigra $\times$ maxmowiczii known a rapidly growing species, the variations of green moisture contents, bulk density, wood fibre dimensions, microfibril angles, and number of leaf knot in stem wood were investigated. The heartwood contained a higher moisture content than the corresponding sapwood. Bulk density in radial patterns variations decrease outward from the pith, then increase toward the bark. The wood-fiber length and diameters had somewhat smaller values than on Populus alba $\times$ glandulosa or Populus euramericana. The microfibril angles decreased rapidly toward the outside, and their mean values were about 16 degree. The grain angles run nearly parallel to the cell axies. Number of leaf knot showed a fluctural change above ground level to a point near the base of the crown and then increased rapidly to the top of tree and average number of leaf knot varied exclusively from tree to tree.

  • PDF

FE analysis of RC pipes under three-edge-bearing test: Pocket and diameter influence

  • Kataoka, Marcela Novischi;da Silva, Jefferson Lins;de Oliveira, Luciane Marcela Filizola;El Debs, Mounir Khalil
    • Computers and Concrete
    • /
    • v.20 no.4
    • /
    • pp.483-490
    • /
    • 2017
  • This paper studies on the behavior of reinforced concrete (RC) pipes used in basic sanitation in the conduction of storm water and sanitary sewer. Pipes with 800 mm and 1200 mm in diameter were analyzed. The 800 mm pipes were built with simple reinforcement and the 1200 mm pipes with double reinforcement. For the two diameters of pipes the presence or absence of the pocket was evaluated, and the denomination of each one is spigot and pocket pipe (SPP) and ogee joint pipe (OJP), respectively. The 3D numerical models reproduce the three-edge-bearing test that provides information about the strength and stiffness of the reinforced concrete pipes. The validation of the computational models was carried out comparing the vertical and horizontal displacements on the springline and crown/invert and it was also evaluated the reinforcement strains and the crack pattern. As a main conclusion, the numerical models represented satisfactorily the behavior of the pipes and can be used in future studies in parametric analysis.