• Title/Summary/Keyword: Cross-ventilation

Search Result 126, Processing Time 0.023 seconds

The Effects of Tunnel Geometrical Characteristics and Canopy Installation on the Ventilation and Fire Propagation (터널의 기하학적 형태 및 캐노피 설치가 터널 환기 및 화재 확산에 미치는 영향 분석)

  • Lee, Chang-Woo;Suh, Ki-Yoon;Kim, Jung-Wook
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.4
    • /
    • pp.325-334
    • /
    • 2006
  • Understanding the airflow characteristics within the canopy structure installed between closely adjacent tunnels either for light adaptation or for protection from snow hazards is required for the normal ventilation as well as safety system design. Grade, horizontal alignment, cross-sectional area and shape are known to substantially influence the fire smoke behavior and their influences raise great concern for the safety design. This paper aims at studying the effects of tunnel geometrical characteristics and canopy installation on the ventilation and fire propagation through CFD analysis. In the case of 145m long canopy, 50% opening ratio is preferred with respect to the airflow pattern and ventilation efficiency. When a 20MW fire occurs in a 1.8km-long tunnel and four 1250mm reversible jet fans are instantly turned on, smoke concentration at 40m downstream of the fire decrease 13% for the upgrade tunnel with 2% gradient and increases 20% for -2% gradient, compared to the standard horizontal tunnel. Backlayering is observed within 45m-long segment toward the entrance in 2% down-graded tunnel. In a rectangular tunnel, there is no significant difference of smoke concentration as well as velocity profile from the standard crown tunnel. Three-laned tunnel shows lower level of both profiles and backlayering is detected up to 50m upstream of the fire, while the risky situation rapidly disappears thereafter.

A study on the operation characteristics of oversized exhaust port applicable to double-deck tunnel (복층터널에 적용 가능한 화재 연동형 대배기구 운영 특성 분석 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Yangkyun;Park, Byoungjik;Kim, Whiseong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.887-895
    • /
    • 2019
  • Recently, the number of underground road development projects has been increasing to solve traffic problems in the national capital region and metropolitan areas with intensified overcrowding, and there has been a tendency to plan underground roads by applying a double-deck tunnel technology that has advantages in constructability and economical efficiency. The double-deck tunnel has a structure where one excavation section is divided into two parts and used as up and down lines, and is mainly used as a road for small vehicles only due to its low floor height. In addition, due to the small cross-sectional area, it has characteristics different from those of general road tunnels in terms of ventilation and disaster prevention. In this regard, this study proposed an operational plan that applies an oversized exhaust system, which is one of semi-transverse ventilation systems, to small cross-sectional tunnels like double-deck tunnel with low floor height, and a comparative analysis between smoke exhaust characteristics according to the fire occurrence locations and oversized exhaust systems was conducted using the Fire Dynamics Simulator (FDS). The results showed that unlike uniform exhaust, intensive smoke exhaust using the oversized exhaust port maximized the delay effect of smoke diffusion and limited the smoke within 50 m above and below the fire point.

A study on cross sectional characteristics and available area for using the lower space in TBM road tunnels (TBM 도로터널의 단면특성 및 하부공간 활용을 위한 유효면적 검토)

  • Kim, Hyun-Soo;Kim, Hong-Moon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.2
    • /
    • pp.141-157
    • /
    • 2012
  • For the application TBM tunneling method, Both tunnel design standard and case study designed & constructed in domestic and foreign have been conducted. According to the study, the number of lane and inner shape (single or duplex) vary depending on the volume of traffic. Also extra space located in the top and bottom of tunnel is used for a multipurpose such as ventilation, disaster prevention, maintenance and administration. To find area ratio according to the components of road TBM tunnel, a standard section was considered as a two-lane road. Then, the analysis of area ratio of this section which consists of components for clearance, extra space in upper and lower tunnel was carried on two widths of shoulder. In addition, after a structural analysis, a thickness requirement of lower slab which is essential for road tunnel was derived on a few supporting types. Through correlation analysis, the ranges of available cross-sectional area between slab thickness and lower extra space of the tunnel was presented.

A Case Study on the Ventilation and Heat Environment in a Underground Limestone Mine with Rampway (Rampway 설치 석회석 광산내 환기 현황 및 열환경 분석 사례연구)

  • Kim, Doo-Young;Lee, Seung-Ho;Jeong, Kyu-Hong;Lee, Chang-Woo
    • Tunnel and Underground Space
    • /
    • v.22 no.3
    • /
    • pp.163-172
    • /
    • 2012
  • As more diesel engines have been employed in underground limestone mines with large cross section, underground space environment is worsened by diesel exhausts and heat flow. This paper aims for the ultimate goal to optimize the work place environment through assuring the optimal required ventilation rate based on the analysis of the airflow, diesel exhaust gas concentrations and the effects of mechanization and deepening working face on temperature and humidity. Due to the insufficient capacity of the main exhaust fan and poor airway management, stagnant airflows were observed at various locations, while the flow direction was reversed instantly with passing diesel equipment and the flow reversal was also made by the seasonal variation of the outside surface weather. During the loading operation, CO concentration measurements were found to be frequently higher than the threshold limit of 50 ppm, and most of the $NO_2$ measurements during drilling and loading operations shows even more serious levels surpassing the permissible limit of 3 ppm. The actual ventilation quantity was considerably less than the required quantity estimated by the mine health and safety law, and this shortage problem was less serious in colder winter showing more effectiveness of the natural ventilation.

Change of End-tidal PCS During Cardiopulmonary Bypass (체외순환시 호기말 이산화탄소압의 변화)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.25 no.12
    • /
    • pp.1399-1403
    • /
    • 1992
  • The evaluation of the effectivess of ongoing cardiopulmonary resucitation efforts is dependent on the commonly used methods, such as the presence of femoral or carotid artery pulsations, arterial blood gas determinations, peripheral arterial pressure and intracardiac pressure monitoring. But recent studies suggest that end-tidal carbon dioxide tension serves as a non-invasive measurement of pulmonary blood flow and therefore cardiac output under constant ventilation. A prospective clinical study was done to determine whether end-tidal carbon dioxide monitoring in open heart surgery under cardiopulmonary bypass could be used as a prognostic indicator of bypass weaning. We monitored end-tidal PCO2 values continuously during cardiopulmonary bypass in 30 patients. "Ohmeda 5210 CO-2 monitor" under infrared absorption method were incorperated into the ventilator circuit by means of a side point adaptor between endotracheal tube and ventilator tubing. 18 patients[Group I ] were res-ucitated from partial bypass followed by aorta cross clamp off and 12 patients[Group II ] from aorta cross clamp off followed by partial bypass. But there was no difference between two groups[p>0.05]. The value of end-tidal carbon dioxide tension during ventricular fibrillation or nearly arrest state was 6.6$\pm$2.9 mmHg, and at the time of spontaneous beating was 19.3$\pm$5.6 mmHg[Mean$\pm$Standard deviation], In conclusion end-tidal carbon dioxide tension monitoring provides clinically useful, continous, noninvasive and supplementary prognostic indicator during cardiopulmonary bypass weaning procedures.rocedures.

  • PDF

Construction Planning and Design of a Long Tunnel (장대 터널의 계획과 설계)

  • 장석부;윤영훈;김용일;김진한
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.117-124
    • /
    • 2000
  • This paper presents the construction planning and the detail design of a 16.2 km long railroad tunnel in a mountainous area. Major design conditions for railroad are the single track, loop-typed alinement, and a maximum grade of 24.5$\textperthousand$. A underground station(double track) with a length of 1.1km is located in the middle of the line for train cross-passing. Tunnel is excavated in highly complex geological conditions including faulted areas, abandoned mine works areas, and various rock types such as sandstone, shale, limestone, and coal seam partly. Drilling and blasting method was adopted because it is more flexible than TBM(Tunnel Boring Machine) as a result of risk assessment for geological conditions in this area. Two working adits were planned to adjust the construction schedule and can be used for ventilation and maintenance in operation phase. New material and concept were introduced to the tunnel drain design. They are expected to improve tunnel drain condition and capability. Rational tunnel support design was tried to consider the various tunnel size and purpose and to use the geological investigation results.

  • PDF

A Study on Performance Characteristics Wide Angle Diffuser Using Guide Damper (안내댐퍼를 이용한 광각디퓨저의 성능특성에 관한 연구)

  • Lee, Cheol-Jae;Lim, Jeong-Sun;Cho, Dae-Hwan
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.281-282
    • /
    • 2006
  • In wide angle diffuser, the increasement of cross-sectional area so rapidly cause possibly separate from the diffuser wall and forming areas of backflow. The flow characteristics of wide angle diffuser with guide damper was investigated for three kind of inclined angle($\alpha=7_{\circ},\;10.5_{\circ}\;and\;14_{\circ}$)of guide damper. Judging from the results, guide damper can be used as an effective means of improvement for diffuser performance and inclined angle of $\alpha=10.5^{\circ}$ was through to be the best among three cases.

  • PDF

Development of a Recursive Local-Correlation PIV Algorithm and Its Performance Test

  • Daichin Daichin;Lee Sang Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.75-85
    • /
    • 2001
  • The hierarchic recursive local-correlation PIV algorithm with CBC(correlation based correction) method was developed to increase the spatial resolution of PIV results and to reduce error vectors. This new algorithm was applied to the single-frame and double-frame cross-correlation PIV techniques. In order to evaluate its performance, the recursive algorithm was tested using synthetic images, PIV standard images from Visualization Society of Japan, real flows including ventilation flow inside a vehicle passenger compartment and wake behind a circular cylinder with rib let surface. As a result, most spurious vectors were suppressed by employing CBC method. In addition, the hierarchical recursive correlation algorithm improved largely the sub-pixel accuracy of PIV results by decreasing the interrogation window size, increasing spatial resolution significantly.

  • PDF

A Study on Performance Characteristics Planar angle diffuser with PIV (PIV를 이용한 평판형 디퓨저의 유동특성에 관한 실험적 연구)

  • Oh, Jeong Hun;Cho, Dae-Hwan;Seok, Baek Un
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2012.06a
    • /
    • pp.261-262
    • /
    • 2012
  • In planar angle diffuser, the increasement of cross-sectional area so rapidly cause possibly separate from the diffuser wall and forming areas of backflow. The flow characteristics of planar angle diffuser was investigated for three kind of inclined angle. Judging from the results, wide planar diffuser can be used as an effective means of improvement for diffuser performance and inclined angle of diffuser was through to be the best among three cases.

  • PDF

Numerical Investigation on Smoke Behavior in Rescue Station for Tunnel Fires (철도터널 화재 시 구난역 내의 연기거동에 대한 수치해석 연구)

  • Hong, Sa-Hoon;Ryou, Hong-Sun;Lee, Seong-Hyuk
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1740-1746
    • /
    • 2008
  • The present study performed numerical investigation to analyze the smoke behavior in the rescue station by using the commercial CFD code (FLUENT Ver 6.3). The present study adopted a 10MW ultrafast mode for simulation, and it also used the MVHS(Modify Volumetric Heat Source) model modified from the original VHS(Volumetric Heat Source) model in order to treat the product generation and the oxygen consumption under the stoichiometric state. In addition, the present simulation includes the species conservation equation for the materialization of heat source and the estimation of smoke movement. From the results, the smoke flows are moving along the ceiling because of thermal buoyancy force and as time goes, the smoke gradually moves downward at the vicinity of the entrance. Moreover, without using ventilation, it is found that the smoke flows no longer spread across the cross-passages because the pressure in the non-accident tunnel is higher than that in the accident tunnel.

  • PDF