• 제목/요약/키워드: Cross-linked polyethylene

검색결과 78건 처리시간 0.031초

HVDC용 나노복합 절연재료의 DC절연파괴 분석 (Analysis of DC dielectric breakdown strength of Nano-composite insulation material for HVDC Cable)

  • 조성훈;정의환;이한주;임기조;정수현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.104-104
    • /
    • 2010
  • With the advent of nano-particle fillers in insulating materials, the insulating materials of superior quality have come to fore. In the recent past, nanocomposite LDPE/XLPE (Low Density Polyethylene/Cross Linked Polyethylene) power cable dielectrics have been synthesized. A preliminary evaluation of these new class of materials seem to show that, addition of small amounts of sub-micron inorganic fillers improved the dielectric properties of the composite, in particular, the volume resistivity, and the DC breakdown strength. The thermal behaviour, for example, the stability of composites against decomposition and ensuing electrical failure, do not seem to have been addressed. In a conventional XLPE insulated cable, the average thermal breakdown strength and maximum temperature at the onset of breakdown were seen to be markedly lower than the corresponding intrinsic breakdown strength and decomposition temperature. In this page, analysis of DC Breakdown of nano-composite insulating material for HVDC Cable is introduced.

  • PDF

Carboxymethyl cellulose/polyethylene glycol superabsorbent hydrogel cross-linked with citric acid

  • Lee, Deuk Yong;Chun, Cheolbyong;Son, Siwon;Kim, Yena
    • 한국결정성장학회지
    • /
    • 제32권3호
    • /
    • pp.107-114
    • /
    • 2022
  • Carboxymethyl cellulose/poly(ethylene glycol) (CMC/PEG) hydrogels crosslinked with citric acid (CA) are synthesized to evaluate the effect of CMC molecular weight (Mw), PEG and CA concentration on the optical property, swelling rate (SR), degradation rate (DR), and cytotoxicity and cell proliferation of hydrogels. For crosslinked CMC/PEG hydrogels, the FT-IR peak intensity associated with hydroxyl groups decreases due to PEG intercalation (esterification crosslinking) between CMC chains in a similar manner as the concentration of CA crosslinker increases. Crosslinked CMC (Mw = 90,000)/PEG hydrogels with 10 % CA dissolve regardless of PEG content. However, the SR of the CMC (Mw = 250,000)/PEG hydrogels decrease from 4923 % to 168 % with increasing PEG and CA concentrations from 0 to 20 % and from 0 to 25 %, respectively. As the Mw of CMC increases, the DR of the hydrogel is greatly improved. CMC (Mw = 250,000)/PEG10 hydrogels with 10 % CA exhibit the optimum properties of high absorbing capacity (3,200 %) with moderate DR (54 %), stiffness (1.39 ± 0.19 GPa), and cell viability (94.8 ± 1.3 %). CA-crosslinked CMC/PEG hydrogels are highly suitable for wound dressing or personal care applications due to their non-toxicity, good cell proliferation, SR, and mechanical properties.

대용량 XLPE 케이블 고찰 (Progress in Technology of Ultrahigh-voltage XLPE Cable)

  • 최창수;이갑중;권병일;남정세
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1356-1358
    • /
    • 1995
  • About 20 years have passed since cross-linked polyethylene(XLPE) came into practical use for power transmission cables. In 1969, We were the first to product 33kV XLPE insulated cables, and in 1984 produced XLPE cable for 154kV. To meet the increasing demand for electric power in large cities, and to improve reliability of the power supply, plans are being made to introduce ultrahigh-tension power cable for long distance underground lines in urban areas. Studies are currently under way to develop more than 154kV XLPE cables to meet increasing demand. In this paper presents the progress in the production and design of XLPE cables, and describes ways in which further improvements seems likely.

  • PDF

전력케이블용 절연재료의 캐리어 극성 및 공간전하 측정기술에 관한 연구-PE-EVA에서의 하전입자의 거동 (A Study on the Space Charge Measurement Technique and Carrier Polarity of Insulating Materials on Power Cable)

  • 국상훈;박중순;강용철;권영수
    • 대한전기학회논문지
    • /
    • 제41권2호
    • /
    • pp.185-191
    • /
    • 1992
  • In this paper, it is attempted to distinguish the charged particles and to judge the polarity by the use of Thermally Stimulated Current(TSC) and Temperature Gradient Thermally Stimulated Surface Potential Measurement(TG-TSSP)with experimental insulation material XLPE-EVA for power cables which is made by blending cross-linked polyethylene(XLPE) and ethylene-vinylacetate copolymer(EVA). In addition, it is performed to investigate the effect of EVA blending. From the experimental results, it is known that for the case of XLPE-EVA blended experimental material, the generation of space charged electric field is not obtained in the high temperature region due to the obatruction of the injection of trapping carrier by the electron and the positive hole.

  • PDF

가교폴리에틸렌의 수트리 성장특성에 관한 연구 (A Study on Growth Characteristics of Water Tree in XLPE)

  • 김덕근;임장섭;김철운;류경우;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.346-349
    • /
    • 1997
  • It is well known that water treeing is one of the main cause of breakdown in underground power cables, but water tree is not easy to observe. This aging phenomenon was resulted in effect of water and electric field and so on. In this paper, Distilled water was used as water electrode to observe the water treeing in XLPE(cross-linked polyethylene). To observe easily, sample was made of pallet types so water tree was able to show by microscope. As a result, electrical tree appears at niddle electrode tip which was concentrated electric field, but water tree was shown up different types that were appealed in total area of water electrode as well as water electrode tip.

  • PDF

내부 보이드 결함에서 발생하는 전기트리의 부분방전 특성 (PD Characteristic of Electrical Tree Generated by Inside Void Defect)

  • 박성희;정해은;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.334-335
    • /
    • 2006
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is 7*5*7 $mm^3$. Distance of needle and plane is 2 mm. Voltages applied for acceleration test are 12 kV to 15 kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system (Biddle instrument). The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

고압케이블의 절연열화 특성 (Characteristics of Insulation Aging in High Voltage Cables)

  • 김경열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.88-88
    • /
    • 2010
  • High Voltage cross-linked polyethylene (XLPE) cables are widely used in a thermal power plant. These cables had been in service for 26 years. The insulation condition of six 6 kV XLPE cables was estimated by insulation diagnostic analyzer (IDA) with voltage amplifier. IDA was measured dissipation factor and capacitance of the whole cable as a function of frequency and voltage. This system measures in the frequency range from 0.1 to 10 Hz at each voltage level. Six XLPE cables are judged good condition, but three cables are analyzed at an aged condition.

  • PDF

부분방전 전하량에 따른 음향방출 센서의 응답특성 (Response Characteristics of Acoustic Emission Sensor according to Partial Discharge Quantities)

  • 정영호
    • 한국전기전자재료학회논문지
    • /
    • 제23권5호
    • /
    • pp.383-387
    • /
    • 2010
  • The response characteristics of AE (acoustic emission) sensors with a coupled vibration mode and a non-coupled vibration mode were investigated according to PD(partial discharge) quantities in XLPE (cross linked polyethylene) sheets and craft papers immersed in insulating oil. The response voltages of a coupled vibration mode AE sensor were linearly proportional to the PD quantities up to 1,000 pC in XLPE sheets, while a non-coupled vibration mode AE sensor did not show the similar linearity. In case of a test of craft papers immersed in insulating oil, a linearity between response voltages and PD quantities was observed up to 550 pC, but after that, similar linearity between response voltage of any types of AE sensor and PD quantities was not shown.

13.8 kV XLPE 케이블의 절연파괴 원인 분석 (Analysis of Insulation Breakdown Cause in 13.8 kV XLPE Cable)

  • 김희동;박용훈;박재현;권재호;박덕현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1173-1174
    • /
    • 2015
  • 내연 발전기(50 MW, 13.8 kV) 출력단자에서 차단기까지 연결된 13.8 kV XLPE(cross-linked polyethylene) 케이블에서 운전중에 절연파괴로 인해 지락이 발생하였다. XLPE 케이블의 건전성을 확인하기 위해 절연저항과 절연진단 시험을 수행하였다. 교류전압을 1~10 kV까지 증가하면서 XLPE 케이블의 유전정접 측정결과 A상과 C상은 0.1%로 일정하게 측정되었다. 반면에 B상의 유전정접은 1 kV에서 0.54%, 2 kV에서 0.68%, 3 kV에서 0.82%, 4 kV에서 1.12%로 증가하였다. 그리고 교류전압을 약 4.3 kV 인가 중에 진단장비가 차단되었다.

  • PDF

XLPE 특고압 전력케이블의 절연 진단 (Diagnostic Test of XLPE Ultra High Voltage Electric Power Cable)

  • 변두균;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.122-126
    • /
    • 2002
  • A diagnostic test of 15.4kV cross-linked polyethylene(XLPE) ultra high voltage power cables from generator in the Soyanggang hydro electric power plant was conducted over 3 months, beginning April 2001. According to the results, in the case of the power cables from generator 1, there was little possibility of proceeding rapid1y to failure or defect because the data from diagnosis doesn't indicate any failure, deterioration or partial discharge. However, in the case of the power cables from generator 2, the. polarization index show a slight abnormal condition of the insulator that is not severe, and the deterioration was also identified as not severe. However, the partial discharge had an abnormal condition which was severe.

  • PDF