• 제목/요약/키워드: Cross-Coupled Control

검색결과 76건 처리시간 0.02초

Comparative analysis of two methods of laser induced boron isotopes separation

  • K.A., Lyakhov;Lee, H.J.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.407-408
    • /
    • 2011
  • Natural boron consists of two stable isotopes 10B and 11B with natural abundance of 18.8 atom percent of 10B and 81.2 atom percent of 11B. The thermal neutron absorption cross-section for 10B and 11B are 3837 barn and 0.005 barn respectively. 10B enriched specific compounds are used for control rods and as a reactor coolant additives. In this work 2 methods for boron enrichment were analysed: 1) Gas irradiation in static conditions. Dissociation occurs due to multiphoton absorption by specific isotopes in appropriately tuned laser field. IR shifted laser pulses are usually used in combination with increasing the laser intensity also improves selectivity up to some degree. In order to prevent recombination of dissociated molecules BCl3 is mixed with H2S 2) SILARC method. Advantages of this method: a) Gas cooling is helpful to split and shrink boron isotopes absorption bands. In order to achieve better selectivity BCl3 gas has to be substantially rarefied (~0.01%-5%) in mixture with carrier gas. b) Laser intensity is lower than in the first method. Some preliminary calculations of dissociation and recombination with carrier gas molecules energetics for both methods will be demonstrated Boron separation in SILARC method can be represented as multistage process: 1) Mixture of BCl3 with carrier gas is putted in reservoir 2) Gas overcooling due to expansion through Laval nozzle 3) IR multiphoton absorption by gas irradiated by specifically tuned laser field with subsequent gradual gas condensation in outlet chamber It is planned to develop software which includes these stages. This software will rely on the following available software based on quantum molecular dynamics in external quantized field: 1) WavePacket: Each particle is treated semiclassicaly based on Wigner transform method 2) Turbomole: It is based on local density methods like density of functional methods (DFT) and its improvement- coupled clusters approach (CC) to take into account quantum correlation. These models will be used to extract information concerning kinetic coefficients, and their dependence on applied external field. Information on radiative corrections to equation of state induced by laser field which take into account possible phase transition (or crossover?) can be also revealed. This mixed phase equation of state with quantum corrections will be further used in hydrodynamical simulations. Moreover results of these hydrodynamical simulations can be compared with results of CFD calculations. The first reasonable question to ask before starting the CFD simulations is whether turbulent effects are significant or not, and how to model turbulence? The questions of laser beam parameters and outlet chamber geometry which are most optimal to make all gas volume irradiated is also discussed. Relationship between enrichment factor and stagnation pressure and temperature based on experimental data is also reported.

  • PDF

대전지역 일개 종합병원 초진결핵 환자들로부터 분리(分離)된 결핵균(結核菌)의 약제(藥劑) 내성률(耐性率) (The resistance rate of anti-tuberculosis drug isolated from initial tuberculosis patients at a general hospital in Daejeon area)

  • 이동훈;김상하;김영권
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5012-5018
    • /
    • 2011
  • 1965년부터 1995까지 결핵의 전국적인 조사에 의하면, 한국에서 결핵의 발생과 약제 내성율은 감소하였지만 다재약제내성율의 유행은 여전히 심각한 문제이다. 본 연구의 목적은 2001 년부터 2008까지 대전에 약제 내성율과 성향을 조사하였다. 총 581건의 약제감수성 검사가 수행 되었으며 이중 하나이상의 항결핵제의 약물에 내성이 있는 경우가 104건(17.9%)이였고 적어도 INH에 내성이 있는 경우가 68건 (11.7 %), RFP내성이 41건(7.1 %)이였다. 단일 약제 내성율은 37건 (6.4 %) 분리되었으며 이들 중 INH에서 18건 (3.1 %) RFP에서 5건(0.9 %)이 분리 되었다. 적어도 isoniazid와 refampin에 내성인 다제내성결핵은 35건(6.0 %)에서 발견되었다. 그리고 MDR - TB와 관련된 나이요인에 40-60 세 포함되었다. 폐결핵의 약제내성율, 특히 MDR - TB의 약제내성율은 공공의료분야보다 민간 병원의 초치료 환자에서 높게 나왔다. 초기 약제내성은 일반적이며 약제감수성 검사는 이전 결핵 치료를 받지 않은 폐결핵 환자에 대해 유용성이 있다. 내성의 확산과 증가를 줄이기 위해 MDR - TB의 조기 진단과 함께 향상된 제어프로그램이 필요하다. 다제내성율은 여전히 한국에서 문제이다. 독립적으로 혹은 공공의료분야와 공동으로 다제내성율을 감소하기 위한 노력이 필요하다.

NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰 (Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube)

  • 최용;김종호;김준영;임기천;김상은;최연성;이경한;주관식;김병태
    • 대한핵의학회지
    • /
    • 제34권1호
    • /
    • pp.82-93
    • /
    • 2000
  • 목적: 이 논문에서는 본 연구진이 개발한 소형 감마카메라 시스템에서 사용한 NaI(Tl)섬광결정-위치민감형 광전자증배관 검출기와 각 전자회로에서의 입 출력 신호특성을 조사하고, 시스템 개발을 위해 각 전자회로에서 결정한 변수들에 대하여 고찰하고자 한다. 대상 및 방법: 크기가 $60{\times}60{\times}6mm^3$인 NaI(Tl) 섬광결정을 위치민감형 광전자증배관에 접합하고, 저항 회로와 전치증폭기, 여러 가지 전자회로, 아날로그-디지털 변환기 그리고 개인용 컴퓨터를 이용하여 소형 감마카메라 시스템을 개발하였다. 섬광결정에서 검출된 신호들을 위치민감형 광전자증배관을 통하여 증폭한 후, 전하분할방법으로 34개의 교차된 양극채널 신호를 4개($X^+,\;X^-,\;Y^+,\;Y^-$) 위치신호로 출력시켰다. 출력된 신호를 전치증폭기와 층폭기를 사용하여 증폭 정형하였으며, 핵기기 모듈(nuclear instrument modules, NIMs)을 이용하여 위치신호와 트리거 신호를 처리하였고, 각 단계에서 신호특성을 분석 고찰하였다. 이 신호들을 아날로그-디지털 변환기와 앵거로직을 사용하여 처리한 후, 일반 개인용 컴퓨터에서 그래픽 프로그램을 이용하여 감마카메라 영상을 구현하였다. 결과: 연구에서 분석 고찰한 신호특성을 그림을 통하여 나타내었으며, 이러한 신호처리를 이용하여 개발한 감마카메라는 약 $8{\times}10^3$ counts/sec/${\mu}Ci$의 계수율을 보였다. 140 keV에 대하여 18% FWHM의 에너지 분해능과 X, Y 방향으로 각각 2.2, 2.3 mm FWHM의 내인성 위치 분해능을 나타내었다. 또한 평행구멍형 조준기를 장착한 상태에서 유방모형에 위치한 $2{\sim}7mm$ 직경의 방사능 분포를 정확하게 영상화할 수 있었다. 결론: 이 연구에서 개발한 소형 감마카메라 시스템을 구성하고 있는 각 전자회로에서 결정한 매개변수와 신호특성 고찰결과를 나타내었다. 이 신호처리 시스템 분석을 통하여 감마선 검출을 이용한 영상표현 기술을 확보할 수 있었으며, 소형 감마카메라 개발을 위한 간단한 신호처리 방법을 고안하여 제시하였다.

  • PDF

에틸렌옥사이드(Ethylene oxide)에 노출된 병원 근로자들의 소핵 빈도와 유전적 감수성 지표와의 연관성 (Analysis of Micronuclei and Its Association with Genetic Polymorphisms in Hospital Workers Exposed to Ethylene Oxide)

  • 이선영;김양지;최영주;이중원;이영현;신미연;김원;윤충식;김성균;정해원
    • 한국환경보건학회지
    • /
    • 제37권6호
    • /
    • pp.429-439
    • /
    • 2011
  • Objectives: Ethylene oxide (EtO) is classified as a human carcinogen, but EtO is still widely used to sterilize heat-sensitive materials in hospitals. Employees working around sterilizers are exposed to EtO after sterilization. The aim of the present study was to assess the exposure of EtO level, coupled with occupationally induced micronuclei from hospital workers. The influence of genetic polymorphisms of detoxifying genes (GSTT1 and GSTM1) and DNA repair genes (XRCC1 and XRCC3) on the frequencies of micronuclei in relation to exposure of EtO was also investigated. Methods: The study population was composed of 35 occupationally exposed workers to EtO, 18 student controls and 44 unexposed hospital controls in Korea. Exposure to EtO is measured by passive personal samplers. We analyzed the frequencies of micronuclei by performing cytokinesis-block micronucleus assay (CBMN assay) and GSTM1, GSTT1, XRCC1, and XRCC3 were also genotyped by performing polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP). Results: The frequencies of micronuclei in EtO exposure group, student controls and hospital controls were $18.00{\pm}7.73$, $10.47{\pm}7.96$ and $13.86{\pm}6.35$ respectively and their differences were statistically significant, but no significant differences according to the level of EtO were observed. There was a dose-response relationship between the frequencies of micronuclei and cumulative dose of EtO, but no significantly differences were observed. We also investigated the influence of genetic polymorphisms (GSTM1, GSTT1, XRCC1, and XRCC3) on the frequencies of micronuclei, but there were no differences in the frequencies of micronuclei by genetic polymorphisms. Conclusions: The frequencies of micronuclei in EtO exposure group was significantly higher than control groups. A dose-response relationship was found between the level of EtO exposure and the frequencies of micronuclei, but no statistically differences were observed. We also found that the frequencies of micronuclei were increased according to cumulative EtO level. There was no association of the genetic GSTM1, GSTT1, XRCC1, and XRCC3 state with the frequency of micronuclei induced by EtO exposure.

반복적 부동화 스트레스가 흰쥐 신장의 말초성 benzodiazepine 수용체에 미치는 영향 (Effects of Repeated Immobilization Stress on the Renal Peripheral Benzodiazepine Receptor in Rats)

  • 박용훈;문한구;신손문;이은주;이은실;하정희
    • Childhood Kidney Diseases
    • /
    • 제3권1호
    • /
    • pp.20-26
    • /
    • 1999
  • 목 적 : 스트레스 유발 고혈압을 일으키는데 말초성 benzodiazepine수용체가 중요한 역할을 하리라 추정되어 왔다. 반복적 부동화 스트레스에 의한 신장의 말초성 benzodiazepine수용체의 변화 양상을 Sprague-Dawley rats와 boderline hypertensive rats의 두 실험동물군에서 비교, 관찰하여 고혈압을 유발하는데 신장의 말초성 benzodiazepine 수용체의 병태생리학적 기능을 규명하고자 하였다. Benzodiazepine수용체의 변화 양상은 방사성 동위원소를 사용한 수용체 결합 반응으로 검색하였으며 elevated plus maze검사로 각 실험동물의 불안도를 측정하여 각 군간의 결과를 비교, 관찰하였다. 방 법 : 불안도를 보기 위하여 측정한 plus-maze performance에서 percent open crosses는 Sprague-Dawley rats ($34.7{\pm}2.2$)에 비해 boderline hypertensive rats ($16.2{\pm}1.7$)가 유의하게 낮았고(P<0.05), percent time in open도 Sprague-Dawley rats ($22.5{\pm}1.0$)에 비해 boderline hypertensive rats ($12.1{\pm}1.2$)가 유의하게 낮아 불안도가 높은 상태임을 나타내었다(P<0.05). 스트레스를 주지 않은 Sprague-Dawley rats의 신장 말초성 benzodiazepine수용체의 수(Bmax: $5.5{\pm}0.6$pmol/mg protein)에 비하여 boderline hypertensive rats의 수용체의 수($3.1{\pm}0.7$pmol/mg protein)는 유의하게 낮았다(P<0.05). 하루 2시간씩 14일간 부동화 스트레스를 부하하였을 때, Sprague-Dawley rats와 boderline hypertensive rats에서 신장의 말초성 benzodiazepine 수용체의 수($7.4{\pm}0.7$$5.9{\pm}1.2$ pmol/mg protein)는 스트레스를 주지 않았을 때보다 증가하였으며(P<0.05), 스트레스에 노출된 boderline hypertensive rats는 스트레스에 노출된 Sprague-Dawley rats에 비하여 신장 말초성 benzodiazepine수용체의 수가 여전히 낮은 수준임을 관찰할 수 있었다(P<0.05). 결 론 : 이상의 결과로부터 신장의 말초성 benzodiazepine수용체는 스트레스 조절작용을 매개하며, 본 수용체의 수적 감소는 스트레스에 의한 고혈압 발생에 중요한 역할을 할 것으로 생각되었다.

  • PDF

NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발 (Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging)

  • 김종호;최용;권홍성;김희중;김상은;최연성;이경한;김문회;주관식;김병태
    • 대한핵의학회지
    • /
    • 제32권4호
    • /
    • pp.365-373
    • /
    • 1998
  • 목적: 일반 감마카메라는 그 크기(${\sim}500mm$ 폭)가 전신영상 획득에 적합하도록 설계되어있어 유방영상 획득에는 비 이상적이다. 이 연구의 목적은 물리적 영상 저하요인인 배후 방사능과 광자감쇠 효과를 최소화하여 높은 공간분해능과 시스템 민감도를 가지며 유방영상에 적합하도록 소형화된 저가-고성능유방암 진단전용 소형 감마카메라 개발이다. 대상 및 방법: 크기가 $60 mm{\times}60 mm{\times}6 mm$인 NaI(T1) 섬광결정을 위치민감형 광전자증배관에 접합시켜 감마선 측정신호인 $X^+,\;X^-,\;Y^+,\;Y^-$를 얻은 다음, 증폭기 등을 포함한 전자회로(nuclear instrument modules, NIM)를 통하여 검출기로부터 발생하는 위치신호와 트리거 신호를 처리하였다. 이 신호들을 아날로그-디지털 변환기와 앵거로직을 사용하여 분석한 후 감마카메라 영상을 구성하여 일반 개인용컴퓨터에 표현하는 시스템을 개발하였다. 개발된 감마카메라의 1차적인 성능을 평가하기 위해 Tc-99m 점선원을 이용하여 내인성 계수율과 플러드 영상을 획득하였다. 또한 일정간격의 구멍이 있는 구멍 마스크와 직경 2, 3, 4, 5, 6, 7 mm 크기의 구모양에 방사능 용액을 채울 수 있는 유방모형을 제작하여 평행구멍형조준기를 장착하고 영상을 획득하였다. 결과: 개발된 감마카메라는 약 $8{\times}10^3 counts/sec/{\mu}Ci$의 계수율을 보였으며, 공간왜곡은 관찰되나 양질의 플러드 영상과 구멍 마스크 영상을 획득할 수 있었고, 유방모형에 위치한 방사능 분포를 정확하게 영상화할 수 있을 뿐 아니라 최소 2 mm의 방사능 위치를 판별할 수 있는 영상을 획득하였다. 결론: NaI(T1)-위치민감형 광전자증배관를 이용하여 유방영상에 적합한 소형감마카메라를 개발하였다. 추후 선형성, 장균일도 및 불응시간에 대한 보정 알고리즘을 완성하여 적용하고, 정상작동 여부를 검사하기 위한 정도관리 방법을 설정하면, 유방 신티그라피의 정확도를 높이는데 기여할 것이다.

  • PDF