• 제목/요약/키워드: Cross spectrum

검색결과 365건 처리시간 0.03초

A Study on PIXE Spectrum Analysis for the Determination of Elemental Contents (원소별 함량결정을 위한 PIXE 스펙트럼 분석에 관한 연구)

  • Jong-Seok OH;;Hae-ILL Bak
    • Nuclear Engineering and Technology
    • /
    • 제22권2호
    • /
    • pp.101-107
    • /
    • 1990
  • The PIXE (Proton Induced X-ray Emission) method is applied to the quantitative analysis of trace elements in tap water, red wine, urine and old black powder samples. Sample irradiations are performed with a 1.202 MeV proton beam from the SNU 1.5-MV Tandem Van de Graaff accelerator, and measurements of X-ray spectra are made by the Si(Li) spectrometer To increase the sensitivity of analysis tap water is preconcentrated by evaporation method. As an internal standard, Ni powder is mixed with black powder sample and yttrium solution is added to the other samples. The analyses of the PIXE spectra are carried out by using the AXIL (Analytical X-ray Analysis by Iterative Least-squares) computer code, in which the routine for least-squares method is based on the Marquardt algorithm. The elements such as Mg, Al, Si, Ti, Fe and Zn are analyzed at sub-ppm levels in the tap water sample. In the red wine sample prepared without preconcentration. the element Ti is detected in the amount of 3ppm. In conclusion, the PIXE method is proved to be appropriate for the analysis of liquid samples by relative measurements using the internal standard. and is expected to be improved by the use of evaluated X-ray production cross-sections and the development of sample preparation techniques.

  • PDF

Sensitivity Analysis of Satellite BUV Ozone Profile Retrievals on Meteorological Parameter Errors (기상 입력장 오차에 대한 자외선 오존 프로파일 산출 알고리즘 민감도 분석)

  • Shin, Daegeun;Bak, Juseon;Kim, Jae Hwan
    • Korean Journal of Remote Sensing
    • /
    • 제34권3호
    • /
    • pp.481-494
    • /
    • 2018
  • The accurate radiative transfer model simulation is essential for an accurate ozone profile retrieval using optimal estimation from backscattered ultraviolet (BUV) measurement. The input parameters of the radiative transfer model are the main factors that determine the model accuracy. In particular, meteorological parameters such as temperature and surface pressure have a direct effect on simulating radiation spectrum as a component for calculating ozone absorption cross section and Rayleigh scattering. Hence, a sensitivity of UV ozone profile retrievals to these parameters has been investigated using radiative transfer model. The surface pressure shows an average error within 100 hPa in the daily / monthly climatological data based on the numerical weather prediction model, and the calculated ozone retrieval error is less than 0.2 DU for each layer. On the other hand, the temperature shows an error of 1-7K depending on the observation station and altitude for the same daily / monthly climatological data, and the calculated ozone retrieval error is about 4 DU for each layer. These results can help to understand the obtained vertical ozone information from satellite. In addition, they are expected to be used effectively in selecting the meteorological input data and establishing the system design direction in the process of applying the algorithm to satellite operation.

The useage of the EPID as a QA tools (EPID의 적정관리 도구로서의 유용성에 관한 연구)

  • Cho Jung Hee;Bang Dong Wan;Yoon Seong Ik;Park Jae Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • 제11권1호
    • /
    • pp.16-21
    • /
    • 1999
  • Purpose : The aim of this study is to conform the possibility of the liquid type EPID as a QC tools to clinical indication and of replacement of the film dosimetry. Aditional aim is to describe a procedure for the use of a EPID as a physics calibration tool in the measurements of radiation beam parameters which are typically carried out with film. Method & Materials : In this study we used the Clinac 2100c/d with EPID. This system contains 65536 liquid-filled ion chambers arranged in a $256{\times}256$ matrix and the imaging area is $32.5{\times}32.5cm$ with liquid layer thickness of 1mm. The EPID was tested for different field sizes under typical clinical conditions and pixel values were calibrated against dose by producing images using various thickness of lead attenuators(lead step wedge) using 6 & 10MV x-ray. We placed various thickness of lead on the table of linear accelerator and set the portal vision an SDD of 100cm. To acquire portal image we change the field size and energy, and we recorded the average pixel value in a $3{\times}3$ pixel region of interest(ROI) at field center was recorded. The pixel values were also measured for different field sizes in order to evaluate the dependence of pixel value on x-ray energy spectrum and various scatter components. Result : The EPID, as a whole, was useful as a QA tool and dosimetry device. In mechanical check, cross-hair centering was well matched and the error was less than ?2mm and light/radiation field coincidence was less than 1mm also. In portal dosimetry the wider the field size the the higher the pixel value and as the lead thickness increase, the pixel value was exponentially decreased. Conclusions : The EPID was very suitable for QA tools and it can be used to measure exit dose during patients treatment with reasonable accuracy. But when indicate the EPID to clincal study deep consideration required

  • PDF

Bioequivalence of Broadcef Capsule to Cefradine Yuhan Capsule (Cephradine 500 mg) (유한세프라딘 캅셀(세프라딘 500 mg)에 대한 브로드세프 캅셀의 생물학적 동등성)

  • Cho, Hea-Young;Lee, Suk;Kang, Hyun-Ah;Oh, In-Joon;Lim, Dong-Koo;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • 제32권3호
    • /
    • pp.215-221
    • /
    • 2002
  • Cephradine is a first generation cephalosporin and has broad spectrum antibacterial activity against gram-positive and gram-negative microorganisms, through inhibition of bacterial cell wall synthesis. Cephradine is useful for treatment of infections of the urinary and respiratory tract, skin and soft tissues. The purpose of the present study was to evaluate the bioequivalence of two cephradine capsules, Cefradine Yuhan (YuHan Corporation) and Broadcef (Ilsung Pharmaceuticals Co. Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). The cephradine release from the two cephradine capsules in vitro was tested using KP VII Apparatus II method with various different kinds of dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty normal male volunteers, $23.10{\pm}2.90$ years in age and $67.69{\pm}8.04\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one capsule containing 500 mg as cephradine was orally administered, blood was taken at predetermined time intervals and the concentrations of cephradine in serum were determined using HPLC method with UV detector. The dissolution profiles of two cephradine capsules were very similar at all dissolution media. Besides, the pharmacokinetic parameters such as $AVC_t,\;C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AVC_t\;and\;C_{max}$ and untransformed $T_{max}$. The results showed that the differences in $AVC_t,\;C_{max}\;and\;T_{max}$ between two capsules based on the Cefradine Yuhan were -2.87%, -0.96% and -4.85%, respectively. There were no sequence effects between two capsules in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of 1og(0.8) to log(1.25) $(e.g.,\;log(0.93){\sim}log(1.02)\;and\;log(0.88){\sim}log(1.13)\;for \;AVC_t\;and\;C_{max},\;respectively)$. The 90% confidence interval using untransformed data was within ${\pm}20%$ $(e.g., \;-17.54{\sim}7.78\;for\;T_{max})$. All parameters met the criteria of KFDA guideline for bioequivalence, indicating that Broadcef capsule is bioequivalent to Cefradine Yuhan capsule.

Dynamics and Liver Disease Specific Aspects of Quality of Life Among Patients with Chronic Liver Disease in Yunnan, China

  • Che, Yan-Hua;You, Jing;Chongsuvivatwong, Virasakdi;Li, Li;Sriplung, Hucha;Yan, Yuan-Zhi;Ma, Si-Jia;Zhang, Xiaoli;Shen, Ting;Chen, He-Min;Rao, Shao-Feng;Zhang, Ru-Yi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권12호
    • /
    • pp.4765-4771
    • /
    • 2014
  • Background: Patients with chronic liver diseases (CLD) may have compromised health related quality of life (HRQoL). Hepatitis B virus (HBV) infection has long been the leading cause of CLD including liver cancer and cirrhosis. Knowledge on different symptom profiles of CLD should help in development of comprehensive treatment and patient care plans. Objective: To access the facets of HRQoL in chronic liver diseases throughout their spectrum of severity. Materials and Methods: A cross-sectional study was conducted in the First Affiliated Hospital of Kunming Medical University in Yunnan Province of China. Both out- and inpatients undergoing treatment protocols for different HBV related liver disease states were consecutively collected from December 2012 to June 2013. ANOVA was used to compare the mean scores of EQ-5D and chronic liver disease questionnaire (CLDQ) among 5 disease groups. The relationship between demographic variables predicting global CLDQ scores and the domains of CLDQ was analysed. Results: A total of 1040 patients including 520 without complications, 91 with compensated cirrhosis, 198 with decompensated cirrhosis, 131 with HCC and 100 with liver failure were recruited. All domains of CLDQ, the means of EQ-5D value and EQ VAS exhibited significant decline with worsening of disease severity from uncomplicated HBV to liver failure. The multivariate regression demonstrated the reduction of mean scores of CLDQ domain at advanced stage. Patients with liver failure and HCC had more HRQoL impairment than other disease states. No effect of patient gender was found. Patient age was associated with 'fatigue' and 'worry' domains (p=0.006; p=0.004) but not with other domains and global scores of CLDQ and ED-5D. Conclusions: The HRQoL in chronic hepatitis B patients is greatly affected by disease states. Care for HBV-related diseases should consider not only the outcomes of treatment strategies but also improvement in patient wellbeing.

Estimated Soft Information based Most Probable Classification Scheme for Sorting Metal Scraps with Laser-induced Breakdown Spectroscopy (레이저유도 플라즈마 분광법을 이용한 폐금속 분류를 위한 추정 연성정보 기반의 최빈 분류 기술)

  • Kim, Eden;Jang, Hyemin;Shin, Sungho;Jeong, Sungho;Hwang, Euiseok
    • Resources Recycling
    • /
    • 제27권1호
    • /
    • pp.84-91
    • /
    • 2018
  • In this study, a novel soft information based most probable classification scheme is proposed for sorting recyclable metal alloys with laser induced breakdown spectroscopy (LIBS). Regression analysis with LIBS captured spectrums for estimating concentrations of common elements can be efficient for classifying unknown arbitrary metal alloys, even when that particular alloy is not included for training. Therefore, partial least square regression (PLSR) is employed in the proposed scheme, where spectrums of the certified reference materials (CRMs) are used for training. With the PLSR model, the concentrations of the test spectrum are estimated independently and are compared to those of CRMs for finding out the most probable class. Then, joint soft information can be obtained by assuming multi-variate normal (MVN) distribution, which enables to account the probability measure or a prior information and improves classification performance. For evaluating the proposed schemes, MVN soft information is evaluated based on PLSR of LIBS captured spectrums of 9 metal CRMs, and tested for classifying unknown metal alloys. Furthermore, the likelihood is evaluated with the radar chart to effectively visualize and search the most probable class among the candidates. By the leave-one-out cross validation tests, the proposed scheme is not only showing improved classification accuracies but also helpful for adaptive post-processing to correct the mis-classifications.

Form and Material Analysis of Yuso Used in Joseon Period Scroll Paintings (조선시대 족자 장황에 사용된 유소 형태 및 재질분석)

  • Jang, Yeonhee;Yun, Eunyoung;Kim, Yein;Park, Jinyoung
    • Conservation Science in Museum
    • /
    • 제17권
    • /
    • pp.69-84
    • /
    • 2016
  • Yuso is the term for decorative tassels of a braided string which hangs a scroll painting. This study, drawing on extant research concerning the yuso made for Joseon period portrait scrolls of kings and meritorious retainers, focuses on the yuso created to hang literati portraits. Concretely, It examines yuso of seven portraits in the collection of the National Museum of Korea in order to characterize their appearance and determine their material composition. The study found that most of the yuso are sixteen-strand strings braided into a rounded cross-section(dongdahoe). The seven yuso, of which six are red and one indigo-blue, reflect the popular style associated with Joseon period literati portraits. The yuso for the portrait of Yun Geup(duksu 3503) is made from gilded paper. Analysis showed Fe particles present in a red pigment underlying the gold layer, suggesting the presence of red ochre(seokganju), an iron oxide mineral. The yuso of the portrait of Shin Im(duksu 4846) is used a paper which contains gold as well as traces of Pb, Hg and Ag. The paper in the yuso for the portrait of Yi Seongwon(bongwan 10122) mainly consisted of Ag, indicating silver paper having been used in its fabrication. The inner paper in the yuso of the portrait of Yi Seogu(sinsu 1065) is a leather combined with Ag, Fe, and Br, according to chemical analysis. The FTIR of the leather sample reveals that the spectrum in the fingerprint region is nearly identical to that of sheepskin, indicating the yuso was made from gold-coated sheepskin.

Bioequivalence of Procezil Tablet 250 mg to $Cefzil^{(R)}$ Tablet 250 mg (Cefprozil 250 mg) (세프질$^{(R)}$ 정 250밀리그람 (세프프로질 250밀리그람)에 대한 프로세질 정 250밀리그람의 생물학적동등성)

  • Kim, Se-Mi;Kang, Min-Sun;Cho, Hea-Young;Lee, Yong-Bok
    • Korean Journal of Clinical Pharmacy
    • /
    • 제20권3호
    • /
    • pp.255-261
    • /
    • 2010
  • Cefprozil is a broad-spectrum oral beta-lactam cephalosporin consisting of cis- and trans-isomeric mixture whose ratio is approximately 90:10. Cefprozil is used to treat certain infections caused by bacteria such as bronchitis and ear, skin, and throat infections. The purpose of the present study was to evaluate the bioequivalence of two cefprozil tablets, $Cefzil^{(R)}$ tablet 250 mg (BMS Pharmaceutical Korea., Ltd.) and Procezil tablet 250 mg (Hanmi Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The in vitro release of cefprozil from the two cefprozil formulations were tested using KP VIII Apparatus I method with water dissolution media. Thirty five healthy male subjects, $24.00{\pm}1.53$ years in age and $69.77{\pm}9.99$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After four tablets containing 1000 mg as cefprozil were orally administered, blood samples were taken at predetermined time intervals and the concentrations of cefprozil in serum were determined using HPLC/UV detector. The dissolution profiles of two formulations were similar in water tested dissolution media. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ on the basis of total-cefprozil were calculated, and computer program (K-BE Test 2002) was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Cefzil^{(R)}$ tablets, were -0.81%, -3.00% and -6.83% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., log 0.9515~log 1.0454 and log 0.9613~log 1.0465 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Procezil tablet was bioequivalent to $Cefzil^{(R)}$ tablet.

A Study Absolute Position Estimation of Sound Source (3차원 음향홀로그래픽을 이용한 음원위치 추정에 관한 연구)

  • Kim, Chun-Duk;Sim, Dong-Youn;Jang, Bee;Lee, Chai-Bong;Cha, Kyung-Hwan
    • The Journal of the Acoustical Society of Korea
    • /
    • 제16권5호
    • /
    • pp.76-82
    • /
    • 1997
  • The paper describes simulations and experimental results using a measuring system which utilizes the acoustic holographic method in order to exactly estimate an absolute position of a sound source. The measuring surface is installed to satisfy with a far field to the sound source and is composed of linear arrayed seven microphones. A measurement is simultaneously recorded by a reference microphone setting up a neighbour sound source and the linear arrayed seven microphones which are moved to the same interval. An absolute position of sound source is estimated by the cross-spectrum method to the received sounds between a reference and the measuring microphones. Phase differences of each microphone and time delays during scanning are compensated to the reference microphone and the measuring time of the first column. An optimal interval for each microphone in the measuring surface is decided by a numerical simulation. A source signal makes use of a sinusoid, and S/N ratio is 30dB in the experiment. The optimal microphone's interval in the simulation and the experiment is decided in order to satisfy with the Nyquist space sampling condition related to the wave length of 2kHz sinusoid. Mainlobe width of a estimated 3D hologram in the case of 2kHz source signal is decreased to 87% and 30% in comparison to 500Hz and 1kHz, and then a valid of simulation results is confirmed. Therefore, we verified a utilization of the study for a sound source estimation using 3ㅇ acoustic holographic method.

  • PDF

Subpixel Shift Estimation in Noisy Image Using Iterative Phase Correlation of A Selected Local Region (잡음 영상에서 국부 영역의 반복적인 위상 상관도를 이용한 부화소 이동량 추정방법)

  • Ha, Ho-Gun;Jang, In-Su;Ko, Kyung-Woo;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • 제47권1호
    • /
    • pp.103-119
    • /
    • 2010
  • In this paper, we propose a subpixel shift estimation method using phase correlation with a local region for the registration of noisy images. Phase correlation is commonly used to estimate the subpixel shift between images, which is derived from analyzing shifted and downsampled images. However, when the images are affected by additive white Gaussian noise and aliasing artifacts, the estimation error is increased. Thus, instead of using the whole image, the proposed method uses a specific local region that is less affect by noises. In addition, to improve the estimation accuracy, iterative phase correlation is applied between selected local regions rather than using a fitting function. the restricted range is determined by analyzing the maximum peak and the two adjacent values of the inverse Fourier transform of the normalized cross power spectrum. In the experiments, the proposed method shows higher accuracy in registering noisy images than the other methods. Thus, the edge-sharpness and clearness in the super-resolved image is also improved.