• 제목/요약/키워드: Cross flow heat exchanger

검색결과 76건 처리시간 0.021초

CFC-대체냉매와 스크롤압축기를 사용한 냉동시스템 성능해석 (Performance Analysis of Refrigeration System Using the CFC-Alternative and Scroll Compressor)

  • 박희용;박경우
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.366-381
    • /
    • 1995
  • A performance analysis of refrigeration system using the HFC-134a and scroll compressor is performed numerically. The refrigeration system mainly consists of various standard components such as heat exchanger, compressor, and expansion device. The model for heat exchanger performance is based on a tube-by-tube method which is analyzed separately by considering the cross-flow heat transfer with the outdoor air flow and pressure drop. Compressor is used the scroll-type compressor which has many merits such as high efficiency, low noise and vibration, and small in size. Short-tube is included as an expansion device. Vapour and liquid line are also considered for the performance analysis of refrigeration system. Using the modeling of various components of refrigeration system, a performance comparison of CFC-12 and HFC-134a is performed numerically for the various outdoor air temperature and various values of short-tube diameter. As the results of this study, the refrigeration system performance decreases as the outdoor air temperature increases. And the optimum short-tube diameter based on COP is 1.37mm for this system.

  • PDF

원자력 발전소에 대한 밀폐 ${CO}_{2}$ 가스터빈 프로세스의 최적화 연구 (II) -열교환기의 설계에 관하여 - (A Study of th Optimum of closed ${CO}_{2}$ Gas Turbine Process for Nuclear Energy Power Plant(II) - For Optimal Design of Heat Exchanger-)

  • 이찬규;이종원
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.251-258
    • /
    • 1990
  • 본 연구에서는 제 1보에서 다루었던 프로세스 해석의 결과들을 토대로 하여 열교환기의 최적 설계를 행하는데 주력하였다. 먼저, 열교환기의 최적 설계를 행하 는데 주력하였다. 먼저, 열교환기의 열설계에 필요한 CO$_{2}$와 Natrium의 물성치 및 열전달에 관한 기존의 실험식들을 여러문헌으로부터 연구 검토한 후 프로그램에 편 리하게 이용할 수 있도록 전산화 하였으며, 열교환기의 설계시 필요한 전체 경비의 최 소화를 기하는 방향으로 최적화된 설계인자들을 결정하도록 시도하였고 또한 최적화된 프로그램을 개발함으로써 인력, 외화 및 에너지 절감의 효과를 얻고자 하였다.

직렬 열교환기의 열전달에 관한 연구 (A Study on the Heat Transfer of In-line Heat Exchanger)

  • 최순열;김민수
    • 동력기계공학회지
    • /
    • 제12권5호
    • /
    • pp.48-53
    • /
    • 2008
  • Heat exchangers are commonly used in practice in a wide range of application, from heating and air-conditioning system in a household, to chemical processing and power production in a large plant. Heat transfer in a heat exchanger usually involves convection in each fluid and conduction through the wall separating the two fluids. The heat transfer characteristics of tube banks of in-line arrangements of four circular cylinders in a cross flow are compared for a range of tube locations and Reynolds numbers. The in-line pitch ratio was set up in the range of $1.5\leq L/d\leq4.0$, where L is the center to center distance and d the circular cylinder diameter, and in the Reynolds number of $13,000\leq Re\leq50,000$. The local and mean Nusselt numbers were estimated, and then. Subsequently, the heat transfer characteristics of four circular cylinders were found to exhibit a strong dependency upon the cylinder spacing and separation point of their upstream cylinders.

  • PDF

에어컨 실외기에서의 유동소음 (Flow Noise in the Outdoor Unit of an Air-conditioner)

  • 이승배;이재환;김휘중;최진규;진성훈;박윤서
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.594-601
    • /
    • 1997
  • Propeller fans are commonly equipped in outdoor units of air-conditioners to provide effective cooling in a dried heat exchanger. A new design technique was developed to satisfy requirements of aerodynamic and aeroacoustic performance, which employs the intersection method of two cylinders for mean camber line. Three proto-types of propeller fan including Palm-Shaped, Highly-Swept(PSHS) fan (proto 3)were not only to provide low lift forces for dipole sound, but also to reduce the organized tip vortices interacting with the fan guide causing narrow-banded rotating instabilities. Cross-correlation technique was applied to study flow noise source characteristics for three proto-type fans designed. The cross-correlations between a microphone at far field and a hot-wire sensor at near field show that flows near hub region of proto 3 fan are less organized and the flow structures especially at high flow rate coefficients for proto 3 fan are less correlated with noise generated than other proto-types fans.

  • PDF

지지격자 혼합날개에 의한 $5{\times}$ 5 봉다발에서 유동 패턴 (A Study of Flow Pattern in $5{\times}5$ Rod Bundle by the Spacer Grid Mixing Vane)

  • 추연준;장석규;김복득;문상기;송철화
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2873-2878
    • /
    • 2007
  • The mixing vanes attached to the spacer grid of rod bundles are used to improve the heat transfer in heat exchanger devices by controlling the characteristics of the flow structures and turbulence. In this study, velocity patterns induced by two types of mixing vane(split and swirl vane) are measured by the PIV technique to better understand how to effect on the cross and secondary vortex flow patterns in $5{\times}$ rod bundle simulating the fuel assembly of the nuclear reactor. A successful measurement of the lateral velocity patterns was conducted using a specially designed beam sheet generator and experimental loop at KAERI. As the result, we found that for the cross flow between subchannels, the split vane is more effective than the swirl vane, while for the secondary vortex flow in each subchannel, the swirl vane's one is larger and longer than split vane's one.

  • PDF

Turbulence Enhancement by Ultrasonically Induced Gaseous Cavitation in the $CO_2$Saturated Water

  • Lee, Seung-Youp;Park, Young-Don
    • Journal of Mechanical Science and Technology
    • /
    • 제16권2호
    • /
    • pp.246-254
    • /
    • 2002
  • Recent primary concern for the design of high performance heat exchanger and highly integrated electronic equipments is to develop an active and creative technologies which enhance the heat transfer without obstructing the coolant flows. In this study, we found through the LDV measurement that the gaseous cavitation induced by ultrasonic vibration applied to the CO$_2$saturated water in the square cross-sectioned straight duct flow enhances the turbulence much more than the case of non-ultrasonic or normal ultrasonic conditions without gaseous cavitation does. We also found that gaseous cavitation can enhance effectively the turbulent heat transfer between the heating surfaces and coolants by destructing the viscous sublayer.

Performance Analysis and Optimal Design of Heat Exchangers Used in High Temperature and High Pressure System

  • Kim, Yang-Gu;Choi, Byoung-Ik;Kim, Kui-Soon;Jeong, Ji-Hwan
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제11권1호
    • /
    • pp.19-25
    • /
    • 2010
  • A computational study for the optimal design of heat exchangers (HX) used in a high temperature and high pressure system is presented. Two types of air to air HX are considered in this study. One is a single-pass cross-flow type with straight plain tubes and the other is a two-pass cross-counter flow type with plain U-tubes. These two types of HX have the staggered arrangement of tubes. The design models are formulated using the number of transfer units ($\varepsilon$-NTU method) and optimized using a genetic algorithm. In order to design compact light weight HX with the minimum pressure loss and the maximum heat exchange rate, the weight of HX core is chosen as the object function. Dimensions and tube pitch ratio of a HX are used as design variables. Demanded performance such as the pressure loss (${\Delta}P$) and the temperature drop (${\Delta}T$) are used as constraints. The performance of HX is discussed and their optimal designs are presented with an investigation of the effect of design variables and constraints.

밀폐형과 개방형이 결합된 복합지열시스템의 지중열교환기 성능 분석 (Performance Analysis of Ground Heat Exchanger in Combined Well and Open-Closed Loops Geothermal (CWG) System)

  • 박영윤;송재용;이근춘;김기준;목종구;박유철
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권5호
    • /
    • pp.23-29
    • /
    • 2017
  • This study was conducted to evaluate performance of geothermal heat exchanger (GHE) in the combined well and open-closed loops geothermal (CWG) systems. The CWG systems were designed to combine open loop geothermal heat pumps and closed loop geothermal heat pumps for high energy efficiency. GHE of the CWG systems could be installed at pumping wells for agricultural usage. To get optimal heat exchange capacity of GHE of the CWG systems, 4 GHEs with various materials and apertures were tested at laboratory scale. Polyethylene (PE) and stainless steel (STS) were selected as GHE materials. The maximum heat exchange capacity of GHEs were estimated to be in the range of 33.0~104 kcal/min. The heat exchange capacity of STS GHEs was 2.4~3.2 times higher than that of PE GHE. The optimal cross section area of GHE and flow rate of circulating water of GHE were estimated to be $2,500mm^2$ and 113 L/min, respectively. For more complicated GHE of the CWG systems, it is necessary to evaluate GHEs at various scales.

2 상 유동장에 놓인 열 교환기 튜브에 작용하는 점성과 압착막 감쇠비의 어림적 해석 모델 (Approximate Model of Viscous and Squeeze-film Damping Ratios of Heat Exchanger Tubes Subjected to Two-Phase Cross-Flow)

  • 심우건
    • 대한기계학회논문집B
    • /
    • 제39권1호
    • /
    • pp.97-107
    • /
    • 2015
  • 2 상 유동장에 놓인 열 교환기 튜브에 작용하는 점성 감쇠비와 압착막 감쇠비를 예측하기 위한 해석 모델이 개발되었다. 열 교환기 튜브에 작용하는 유동유발진동을 해석하기 위하여 감쇠에 대한 정보가 요구된다. 열 교환기 튜브에서 가장 중요한 에너지 소산 기구는 튜브와 지지물과 같은 구조물과 액체 사이의 동적 작용에 연계되어 있다. 본 모델은 1997 년 발표된 근사모델에 근거하고 부가질량계수를 고려하여 개발되었다. 어림적 해석모델은 동심환 내에서 진동하는 내부 실린더에 작용하는 수력학적 힘을 계산하기 위하여 개발되었다. 점성력을 포함한 수동력은 높고 혹은 낮은 진동 레이놀드 수에 따라 개발된 두 가지 모델을 사용하여 각각 계산할 수 있다. 관군과 지지대에서의 상당 직경과 침투깊이는 관군에 작용하는 점성 감쇠력과 지지대에서의 압착막 감쇠력을 각각 계산하는데 매우 중요한 변수이다. 2 상 유동의 기공률을 계산하기 위하여 균질모델이 사용되었다. 본 모델을 검증하기 위하여, 모델의 해석결과는 기존의 이론으로 구한 결과와 비교하였다. 본 모델을 사용하여 점성 감쇠비와 압착막 감쇠비를 어림적으로 구할 수 있음을 보였다.

직교.대향류 충진재를 이용한 하이브리드 냉각탑에 대한 실험적 연구 (The Experimental Study of the Hybrid Cooling Tower using Cross and Counter Type Fills)

  • 전철호;이호생;이호출;문춘근;김재돌;김은필;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.236-237
    • /
    • 2005
  • An experimental study on the Hybrid Cooling Tower has been done having a rated capacity of 3RT. Counter flow type fill, cross flow type fill and hybrid-type fill which is combined with two type fills as previously stated having a height of 0.3m have been used in the 0.8m${\times}$0.4m${\times}$1.9m dimensional tower respectively. The heat exchanger is consisting of 2 or 3 rows. The relevant temperatures and the velocities were selected based on the typical Korean weather for the year round operation of the tower. The cooling capacity of the tower is explained with respect to varying air inlet velocities, wet-bulb temperatures, and air to cooling water volume flow rate ratio (L/G ratio). The capacity of the hybrid-type fill was much superior to other fills, but hybrid-type fill shows higher pressure drop.

  • PDF