PLC Optical Sensor for Contamination Monitoring on the Flow-Cell in the Water Quality Measurement System (수질 측정용 플로우 셀의 오염 모니터링을 위한 평면광도파로 센서)

  • Han, Seung Heon;Kim, Tae Un;Jung, Haeng Yun;Ki, Hyun Chul;Kim, Doo Gun;Kim, Seon Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.6
    • /
    • pp.472-476
    • /
    • 2019
  • We have proposed a novel planar lightwave circuit (PLC) optical sensor to monitor the contamination in a flow-cell where water is continuously supplied through a water quality measurement system. We designed a PLC chip with a V-shape waveguide and the simulated its function as a sensor for monitoring contamination in a flow-cell using a numerical the FDTD (finite-difference time-domain) analysis. A novel cross type of waveguide was introduced to make the PLC chip of the V-shaped waveguide. The fabricated PLC was cut into the cross waveguide. A change in the optical propagation loss of the PLC sensor was observed after immersing the PLC sensor into city water. It was determined that the propagation loss of the PLC sensor was 3 dB at a wavelength of $1.55{\mu}m$ in the city water for 15 days.

A Study on the Measurement of Bacterial Contamination of MRI Examination Equipment and Disinfection Conditions (자기공명영상검사장비의 세균오염도 측정 및 소독에 관한 연구)

  • Jeung, Seung-Woon;Lim, Chung-Hwan;You, In-Gyu
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.665-672
    • /
    • 2013
  • In radiology department, where patients with a variety of diseases receive their tests, there is a large possibility of cross contamination of nosocomial infection. Magnetic resonance imaging (MRI) tests take particularly more time than other tests do, which increases the possibility of being exposed to cross contamination. Therefore, this research examines the status of MRI equipment sterilization and investigates the bacterial distribution on head coils, which have the most frequent contact with patients, patient fixation blocks, and bores, which are confined spaces. The status of MRI equipment disinfection was examined by a survey targeting 150 employees, and the distribution of bacteria was measured in ten medical facilities. The result of bacterial distribution tests on MRI equipment showed various bacteria, including Staphylococcus, Acinetobacter, Sphingomona, Pantoea agglomeranss, Micrococcus, Bacillus, Saprophyticus, Brevundimona, and Myroidesspecies. The result of examining the stat us of MRI room disinfection showed that the disinfections of the head coil, block, and bore were implemented well, and the largest proportion was carried out once a day in the morning. The time and implementation of disinfection by the disinfection manager showed that they were implemented well when the manager was the MRI room examiner. The disinfection after examining a patient using an appropriate disinfectant is mandatory to prevent cross contamination.

Effect of a CPR Educational Face Shield on Pathogenic Bacteria Protection (심폐소생술 교육용 페이스 쉴드의 병원성 세균 차단 효과)

  • Kim, Eun-Mee;Shim, Gyu-Sik;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.137-141
    • /
    • 2016
  • Cross contamination between a patient and rescuer or CPR trainees can occur when performing mouth to mouth ventilation during cardiopulmonary resuscitation (CPR). On the other hand, there has been a lack of research on the filtration efficacy of face shields that are designed to protect people from cross-contamination. This study aims to secure the safety of rescuers from communicable diseases in pre-hospital emergency settings and CPR trainees by verifying the protective effects of face shields. The FA shield and CM Shield were used to verify the safety. The bacteria collected from filters used by CPR trainees were incubated. These incubated bacteria were smeared onto the new filters, and were then blown out through the filters using a Bag Valve Mask (BVM) and the pathogens at the front and the back of the filters were checked. While the FA shield was effective in preventing the transmission of pathogens, the CM shield did not prevent the transmission of pathogens. Therefore, some of face shields that received national certification are ineffective in preventing cross-contamination. Accordingly, it is necessary to verify the safety of other face shields used domestically.

A Study of the Mask and Hand Contamination in Dental Clinic (치과에서의 마스크 및 손의 미생물 오염정도 비교)

  • Pyo, Eunji;Lee, Kyunghee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.3
    • /
    • pp.85-94
    • /
    • 2019
  • Purpose: The purpose of this study was to observe the degree of mask contamination in dental hygienist for general and oral bacteria and to identify areas of mask contamination after treatment. Methods: Masks were collected with every fifty dental hygienists who currently working in the department of preventive dentistry, prosthodontics, and orthodontics in Busan. The mask bacteria were collected in specific upper and side parts of the mask. Hand germs were collected using sterile cotton swabs, and then placed in a sterile conical tube. These were transferred to the laboratory. Hand germs and mask bacteria were incubated with nutrient broth (NB) and brain heart infusion broth (BHI) for 24 hrs and each cultured with NB and BHI plate at $37^{\circ}C$ for 48 hrs. Collected data were analyzed using the SPSS Window 20. Results: The number of bacteria was observed in the order of the department of preventive dentistry ($10.1{\times}10^5CFU/ml$), prosthodontics ($14.7{\times}10^5CFU/ml$), and orthodontics ($23.3{\times}10^5CFU/ml$) in the hand. In general bacteria, the difference of contamination was seen by the parts of the mask, but there was no significant difference. However, the oral bacteria were observed highly contaminated upper part of the mask in preventive dentistry. The mask contamination according to the medical departments was observed. Especially, the contamination of mask in preventive dentistry was significantly higher than other departments in oral bacteria. Conclusion: This study suggested that correct mask replacement and recognition of contamination areas can contribute to the prevention of infectious disease. and it would be necessary to increase hand hygiene performance to prevent cross-infection with masks. Also, this study may give an idea for making guidelines for mask management and supporting to establish clear criteria for the education program of personal protective equipment.

The Poetics of Overcoming: Christopher Dewdney's Transhumanism and Dionisio D. Martinez's Transnational Cultural Contamination

  • Kim, Youngmin
    • Journal of English Language & Literature
    • /
    • v.57 no.6
    • /
    • pp.1089-1109
    • /
    • 2011
  • In an attempt to demonstrate in context of Nietzsche's "overman" (ubermensch) and Heidegger's "Being-in-the-World" (Dasein) the collective human efforts to overcome humanism in crisis, I will provide the ground for the poetics of overcoming, the ground which are based upon the double movements of transhumanism and transnationalism. For this purpose, I will turn to the theories of two distinctive poets who reveal and disreveal their truths about the subjecthood or the subjectivity in terms of overcoming: Christopher Dewdney for posthuman transhumanity and Dionisio D. Martinez for transnational cultural contamination Transhumanism represented by Christopher Dewdney manifests an interfusion of outside and inside, thereby collapsing the boundary between the mind and the world, and provides a breakthrough from the limitedly defined mind to the transhuman perspective of overcoming by using terminalogy and techniques from science and technology. The emerging transhumanism reflects the growing interdependence between humans and bio technologies, and suggests a potential improvement of human beings. The main argument of transhumanism is that we humans can and should continue to develop in all possible directions, by overcoming our human limitations by shedding the body and having the disembodied consciousness which will liberate our mind. Kwame Anthony Appiah's "cultural contamination" is another form of overcoming as well as a way to otherness, a counter-ideal of cultural purity which sustains authentic culture, reversing the traditional binary opposition between enriching authenticity and threatening hybridization. Dionisio Martinez's poetry sublimates the negative side of Appiah's concept of contamination, by redeeming the value of the Appiah's list of the ideal of contamination such as hybridity, impurity, intermingling, the transformation that comes of new and unexpected combinations of human beings, a bit of this and a bit of that is how newness enters the world. When a poetic subject is doubly exiled and doubly homeless away from his/her native homeland and home of native language, one has no more identification with the authentic culture of both home and away, but rather anticipates a new identity as a transnational subject to cross the bridge beyond cultural authenticity and to enter into the field of cultural contamination.

Survey of Staphylococcus epidermidis Contamination on the Hands of Dental Hygienists and Equipment Surface of Dental Clinics (치과의료기관 의료장비 표면 및 치과위생사 손의 Staphylococcus epidermidis 오염도 조사)

  • Kim, Seol-Hee
    • Journal of dental hygiene science
    • /
    • v.17 no.6
    • /
    • pp.472-480
    • /
    • 2017
  • The purpose of this study was to investigate Staphylococcus epidermidis contamination on hands of 20 dental hygienists and 140 equipment surface of 20 dental clinics in a local area, from July to August 2017. The degree of S. epidermidis contamination was measured using a hand plate and a rodac plate and then cultured at $35^{\circ}C$ for 24 hours. Based on hand plate criteria, hand contamination was classified into low, middle, and high groups. Analysis of the variance (ANOVA) of the contamination level of the hand parts of the group surface contamination level of the dental clinic equipment was descriptive statistics after clustering lock count. S. epidermidis contamination was moderate in 55% of the hands of dental hygienists. The area of contamination was 29.45 colony-forming units (CFU) on the palm, followed by the middle finger 7.8 CFU, ring finger 6.4 CFU, and thumb 6 CFU. Medical equipment surface contamination was showed that 3-way handle 4.45 CFU, computer mouse 3.37 CFU, mirror handle 1.60 CFU were higher than other areas. The group with high hand contamination had a high positive correlation with the S. epidermidis contamination of the hand. S. epidermidis contamination level was higher on hands than on the medical equipment surface contamination. Therefore, medical staff should recognize the importance of hand hygiene which should be practiced in the manner suggested by World Health Organization. In addition, the medical team needs to be responsible for performing infection control tasks, implementing infection management guidelines and providing systematic education on infectious disease management.

Source Identification of Nitrate contamination in Groundwater of an Agricultural Site, Jeungpyeong, Korea

  • 전성천;이강근;배광옥;정형재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.63-66
    • /
    • 2003
  • This study applied a hydrogeological field survey and isotope investigation to identify source locations and delineate pathways of groundwater contamination by nitrogen compounds. The infiltration and recharge processes were analyzed with groundwater-level fluctuation data and oxygen-hydrogen stable isotope data. The groundwater flow pattern was investigated through groundwater flow modeling and spatial and temporal variation of oxygen isotope data. Based on the flow analysis and nitrogen isotope data, source types of nitrate contamination in groundwater are identified. Groundwater recharge largely occurs in spring and summer due to precipitation or irrigation water in rice fields. Based on oxygen isotope data and cross-correlation between precipitation and groundwater level changes, groundwater recharge was found to be mainly caused by irrigation in spring and by precipitation at other times. The groundwater flow velocity calculated by a time series of spatial correlations, 231 m/yr, is in good accordance with the linear velocity estimated from hydrogeologic data. Nitrate contamination sources are natural and fertilized soils as non-point sources, and septic and animal wastes as point sources. Seasonal loading and spatial distribution of nitrate sources are estimated by using oxygen and nitrogen isotopic data.

  • PDF

Influence of Metallic Contamination on Photovoltaic Characteristics of n-type Silicon Solar-cells (중금속 오염이 n형 실리콘 태양전지의 전기적 특성에 미치는 영향에 대한 연구)

  • Kim, Il-Hwan;Park, Jun-Seong;Park, Jea-Gun
    • Current Photovoltaic Research
    • /
    • v.6 no.1
    • /
    • pp.17-20
    • /
    • 2018
  • The dependency of the photovoltaic performance of p-/n-type silicon solar-cells on the metallic contaminant type (Fe, Cu, and Ni) and concentration was investigated. The minority-carrier recombination lifetime was degraded with increasing metallic contaminant concentration, however, the degradation sensitivity of recombination lifetime was lower at n-type than p-type silicon wafer, which means n-type silicon wafer have an immunity to the effect of metallic contamination. This is because heavy metal ions with positive charge have a much larger capture cross section of electron than hole, so that reaction with electrons occurs much more easily. The power conversion efficiency of n-type solar-cells was degraded by 9.73% when metallic impurities were introduced in the silicon bulk, which is lower degradation compared to p-type solar-cells (15.61% of efficiency degradation). Therefore, n-type silicon solar-cells have a potential to achieve high efficiency of the solar-cell in the future with a merit of immunity against metal contamination.

Consumer Hygiene Practices Regarding the Use of Home Refrigerators to Store Meat in the Capital Area of Korea

  • Lee, Jong-Kyung;Kim, Eun-Hae;Lee, Min-A
    • Food Science of Animal Resources
    • /
    • v.33 no.2
    • /
    • pp.149-154
    • /
    • 2013
  • Food hygiene practices must be maintained from farm to table in order to prevent contamination by microorganisms. This study was conducted to investigate consumer hygiene practices related to the refrigerator storage of meat, including a microbial analysis, monitoring of refrigerator temperatures and consumer surveys of female homeowners in the capital area of Korea. Home refrigerator temperatures were maintained above $5^{\circ}C$ in 26 (19.7%) of the 132 houses investigated. The percentage of the refrigerators with a total microbial count over $10^2\;CFU/100\;cm^2$ was 14.4%. No E. coli, Salmonella spp. or Listeria monocytogenes microbes were detected. However, Staphylococcus aureus was detected in 14 houses (10.6%). The only statistically significant difference in hygiene practices between the non-contamination group and contamination group was in the last time of refrigerator cleaning (p<0.01), as determined by the consumer survey. To improve food hygiene when using a refrigerator, raw materials must be packaged, meat should be stored only on a designated shelf, and cooked foods must be contained to prevent cross-contamination. The refrigerator should be cleaned regularly, at least once a month, and refrigerator thermometers should be monitored below $5^{\circ}C$ in order to keep food safe.

Interface Control to get Higher Efficiency in a-Si:H Solar Cell

  • Han, Seung-Hee;Kim, En-Kyeom;Park, Won-Woong;Moon, Sun-Woo;Kim, Kyung-Hun;Kim, Sung-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.193-193
    • /
    • 2012
  • In thin film silicon solar cells, p-i-n structure is adopted instead of p/n junction structure as in wafer-based Si solar cells. PECVD is the most widely used thin film deposition process for a-Si:H or ${\mu}c$-Si:H solar cells. Single-chamber PECVD system for a-Si:H solar cell manufacturing has the advantage of lower initial investment and maintenance cost for the equipment. However, in single-chamber PECVD system, doped and intrinsic layers are deposited in one plasma chamber, which inevitably impedes sharp dopant profiles at the interfaces due to the contamination from previous deposition process. The cross-contamination between layers is a serious drawback of single-chamber PECVD system. In this study, a new plasma process to solve the cross-contamination problem in a single-chamber PECVD system was suggested. In order to remove the deposited B inside of the plasma chamber during p-layer deposition, a high RF power was applied right after p-layer deposition with SiH4 gas off, which is then followed by i-layer, n-layer, and Ag top-electrode deposition without vacuum break. In addition to the p-i interface control, various interface control techniques such as FTO-glass pre-annealing in O2 environment to further reduce sheet resistance of FTO-glass, thin layer of TiO2 deposition to prevent H2 plasma reduction of FTO layer, and hydrogen plasma treatment prior to n-layer deposition, etc. were developed. The best initial solar cell efficiency using single-chamber PECVD system of 10.5% for test cell area of 0.2 $cm^2$ could be achieved by adopting various interface control methods.

  • PDF