• Title/Summary/Keyword: Cross Ratio

Search Result 2,697, Processing Time 0.027 seconds

Slenderness ratio of telescopic cylinder-columns

  • Sugiyama, Yoshihiko;Ohtomo, Takamitsu
    • Structural Engineering and Mechanics
    • /
    • v.12 no.3
    • /
    • pp.329-339
    • /
    • 2001
  • The present paper deals with the effective slenderness ratio of telescopic cylinders as a long column having different cross sections. Firstly, the slenderness ratio defined in the current standard for the telescopic cylinders is discussed to point out some difficulties which arise when the ratio is applied to the column having different cross sections. Secondly, a new effective slenderness ratio is proposed for columns having different cross sections by introducing a partial effective slenderness ratio. Finally, the proposed slenderness ratio is applied, for extending and development of discussion, to a two-staged column having piece-wise constant cross sections and a cylindrical column having linearly varying diameters.

Free Vibrations of Circular Curved Beams with Constant Volume (일정체적 원호형 곡선보의 자유진동)

  • Lee, Byoung-Koo;Lee, Tae-Eun;Choi, Jong-Min;Park, Chang-Eun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.6
    • /
    • pp.570-579
    • /
    • 2011
  • This paper deals with free vibrations of the circular curved beams with constant volume, whose cross sectional shapes are the circular solid cross-sections. Volumes of the objective beam are always held in constant regardless shape functions of the cross-sectional radius. The shape functions are chosen as the linear, parabolic and sinusoidal ones. Ordinary differential equations governing free vibrations of such beam are derived and solved numerically for determining the natural frequencies. In numerical examples, the hinged-hinged, hinged-clamped and clamped-clamped end constraints are considered. As the numerical results, relationships between frequency parameters and various beam parameters such as rise ratio, section ratio, elasticity ratio, volume ratio, slenderness ratio and taper type are reported in tables and figures.

POSITIVE COEXISTENCE FOR A SIMPLE FOOD CHAIN MODEL WITH RATIO-DEPENDENT FUNCTIONAL RESPONSE AND CROSS-DIFFUSION

  • Ko, Won-Lyul;Ahn, In-Kyung
    • Communications of the Korean Mathematical Society
    • /
    • v.21 no.4
    • /
    • pp.701-717
    • /
    • 2006
  • The positive coexistence of a simple food chain model with ratio-dependent functional response and cross-diffusion is discussed. Especially, when a cross-diffusion is small enough, the existence of positive solutions of the system concerned can be expected. The extinction conditions for all three interacting species and for one or two of three species are studied. Moreover, when a cross-diffusion is sufficiently large, the extinction of prey species with cross-diffusion interaction to predator occurs. The method employed is the comparison argument for elliptic problem and fixed point theory in a positive cone on a Banach space.

Characteristics of SMD and Volume Flux of Two-phase Jet Injected into Cross-flow with Various Gas-liquid Ratio and Reynolds Number (횡단 유동장의 기액비 및 레이놀즈수 변화에 따른 외부혼합형 이상유체 제트의 액적크기 및 체적유속 특성)

  • Kim, Jong-Hyun;Lee, Bong-Soo;Koo, Ja-Ye
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.75-81
    • /
    • 2009
  • A study was performed to investigate the characteristics of two-phase jet injected into subsonic cross-flow using the external mixed gas blast two-phase nozzle. The shadowgraph method was adopted for the cross-flow jet visualization and PDPA system was used to measure droplet size, velocity, and volume flux. The atomization of two-phase jet is initially determined according to gas to liquid mass flow-rate ratio and the Reynolds number of cross-flows. The highest penetration trajectories of two-phase jet injected into cross-flow are governed by the momentum ratio at subsonic cross-flow. As GLR of two-phase jet injected into cross-flow increases, the droplet size decreases and the distribution area of volume flux increases. The distribution of volume flux that influenced by the counter vortex pair at the downstream of cross-flow is symmetric in shape of horseshoe.

Preparations of the Cross-linked Chitosan Based on a Marine Natural Product with Epichlorohydrine for the Exclusion of Heavy Metal Ions from the Various Wastewater and Its Effect of Crosslinking Ratio (각종 폐수로부터 중금속 이온을 제거하기 위한 Epichlorohydrine-가교키토산의 제조 및 가교도의 효과)

  • Park, Young-Mi;Jeon, Dong-Won
    • Fashion & Textile Research Journal
    • /
    • v.8 no.5
    • /
    • pp.577-584
    • /
    • 2006
  • The binding of heavy metal ions onto cross-linked chitosan in dilute aqueous solution has been investigated as a function of pH (4.0 and 7.0), agitation period (10-180min) and concentration of various metal cations (5, 10, 50 and 100ppm). In order to obtain adsorbents that are insoluble and stable, and prevent the dissolution loss of chitosan into an acidic aqueous solution, chitosan flakes were cross-linked with epichlorohydrine (ECH) and its adsorption behavior was compared with that of the non cross-linked chitosan. An advantage of ECH is that it does not eliminate the cationic amine functional group of chitosan. In terms of adsorption ratio, the chitosan cross-linked at an ECH was inferior to original chitosan and was found that chitosan has a selectivity much remarkable than the cross-linked chitosan in low concentrated metal solutions. However, no significant decreases in the adsorption ratios were observed between the cross-linked ECH-chitosan and the non cross-linked chitosan concerning the adsorption of $Ni^{2+}$, $Co^{2+}$, $Pb^{2+}$ and $Zn^{2+}$ acidic solution.

Chip Forming Characteristics of Bi-S Free Machining Steel (Bi-S 쾌삭강의 칩생성특성)

  • 조삼규
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.48-54
    • /
    • 2000
  • In this study the characteristics of chip formation of the cold drawn Bi-S free machining steels were assessed. And for comparison those of the cold drawn Pb-S free machining steel the hot rolled low carbon steel which has MnS as free machining inclusions and the conventional steels were also investigated. During chip formation the cold drawn free machining steels show relatively little change in thickness and width of chip compare to those of the conventional carbon steels. And a single parameter which indicates the degree of deformation during chip formation chip cross-section area ratio is introduced. The chip cross-section area ratio is defined as chip cross-section area is divided by undeformed chip cross-section area. The variational patters of the chip cross-section area ratio of the materials cut are similar to those of the shear strain values. The shear stress however seems to be dependent on the carbon content of the materials. The cold drawn Bi-S and Pb-S steels show nearly the same chip forming behaviors and the energy consumed during chip formation is almost same. A low carbon steel without free machining aids shows poor chip breakability due to its high ductility. By introducing a small amount of free machining inclusions such as MnS Bi, Pb or merely increasing carbon content the chip breakability improves significantly.

  • PDF

Effect of Antimicrobial Activity of the Glutaraldehyde Cross-linked Glucosamine (글루코사민-글루타르알데히드 가교결합체의 항균 효과)

  • Lee, Choon Geun;Hwang, You Jin;Park, Jae Kweon
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.6 no.2
    • /
    • pp.53-61
    • /
    • 2014
  • This study was investigated the antimicrobial activity of glutaraldehyde cross-linked glucosamine. Glutaraldehyde was used as a cross-linker which specifically combines an amine-group of molecules. To optimize the mixing ratio of glutaraldehyde and glucosamine, mixing ratio was set up 1:1, 2:1, 3:1 and 0.5:1 in molarity, respectively. The optimum mixing ratio of glucosamine and glutaraldehyde was found to be 3:1 using thin layer chromatography based on the production of complex. Glucosamine-glutaraldehyde cross-linked complex (Ggcc) revealed significant antimicrobial activity toward PWG than F1, both microbial strains were isolated from porcine semen as antibiotics resistance bacteria (ARB). These results clearly demonstrate that Ggcc has potential bactericidal activity toward ARB in porcine semen.

An Experimental Study on Stress-Strain Behavior of Confined Concrete Columns with Rectangular Sections (직사각형 단면 콘크리트 기둥의 응력-변형 거동에 관한 실험연구)

  • Oh, Byung-Hwan;Kim, Ki-Wan;Choi, Seung-Won;Park, Young-Ho
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.345-352
    • /
    • 2005
  • The purpose of this study is to analyze the stress-strain behavior of confined concrete columns with rectangular section. Uniaxial concentric loading tests of nineteen concrete columns with rectangular section ($150{\times}100$, $250{\times}100$, $350{\times}100\;mm$) were conducted. The main variables are transverse reinforcement volumetric ratio and spacing, cross tie arrangement, cross-section aspect ratio, and concrete strength. From the present experiments, it was found that the increase of transverse reinforcement ratio increases the maximum stress and ductility ratio and the reduction of the spacing of transverse reinforcement also increases the ductility and effective confinement. The increase of the aspect ratio of the cross-section does not influence much the stress-strain behavior of rectangular columns within the aspect ratio range of 3.5. The effect of concrete strength on ductility is also discussed.

  • PDF

A Study on the Characteristics of Cross-contamination according to the Size and Separation distance of Exterior Air-vents (실외 급배기구 크기와 이격거리에 따른 교차오염 특성연구)

  • Moon, Yong-Jun;Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.393-398
    • /
    • 2006
  • This study is undertaken to evaluate the characteristics of cross contamination around exterior air-vents. A CFD analysis has been performed to calculate the cross contamination index for five exterior air-vents sizes according to the outdoor air velocity and separation distance of it. From the result of the numerical method, As the outdoor air velocity is increased, the cross contamination index is increased. on the contrary, as the separation distance of exterior air-vents is increased, the cross contamination index is decreased, additionally the cross contamination is affected by the aspect ratio of the size of exterior Air-vents.

  • PDF

Cross-Linked Starch Microspheres: Effect of Cross-Linking Condition on the Microsphere Characteristics

  • Atyabi, Fatemeh;Manoochehri, Saeed;Moghadam, Shadi H.;Dinarvand, Rassoul
    • Archives of Pharmacal Research
    • /
    • v.29 no.12
    • /
    • pp.1179-1186
    • /
    • 2006
  • Cross-linked starch microspheres were prepared using different kinds of cross-linking agents. The influence of several parameters on morphology, size, swelling ratio and drug release rate from these microspheres were evaluated. These parameters included cross-linker type, concentration and the duration of cross-linking reaction. Microspheres cross-linked with glutaraldehyde had smooth surface compared with those prepared with epichlorhydrine or formaldehyde. The particle size increased with increasing the cross-linking time and increasing the drug loading. Swelling ratio of the particles was a function of cross-linker type but not the concentration or time of cross-linking. Drug release from starch microspheres was measured in phosphate buffer and also in phosphate buffer containing a-amylase. Results showed that microspheres cross-linked with epichlorhydrine released all their drug content in the first 30 minutes. However, cross-linking of the starch microspheres with glutaraldehyde or formaldehyde decreased drug release rate. SEM and drug release studies showed that cross-linked starch microspheres were susceptible to the enzymatic degradation under the influence of alpha-amylase. Changing the enzyme concentration from 5000 to 10,000 IU/L, increased drug release rate but higher concentration of enzyme (20,000 IU/L) caused no more acceleration.