• 제목/요약/키워드: Cross Capacitance

검색결과 71건 처리시간 0.027초

흡연이 수태음폐경 특정혈의 체표생체전하에 미치는 영향: 교차대조 연구 (The Effect of Smoking on the Bioelectrical Capacitance Measured at Specific Acupoints of Lung Meridian: A Cross-Over Study)

  • 김태민;이찬;이현진;임윤경
    • Korean Journal of Acupuncture
    • /
    • 제31권2호
    • /
    • pp.90-97
    • /
    • 2014
  • Objective : The objective of this study is to investigate the effects of smoking on the skin bioelectrical capacitance at specific acupoints of lung meridian. Methods : Bioelectrical capacitance was measured on bilateral six source points(bilateral LU10, LU9, LU7, LU6, LU5, LU1), and the changes with time and between left and right side were analyzed. Results : The skin bioelectrical capacitance at specific acupoints of lung meridian was significantly increased after smoking. And it recovered as time passed. The change of the skin bioelectrical capacitances at specific acupoints of lung meridian with time were similar between left and right. Conclusion : Smoking increases the bioelectrical capacitance at specific acupoints of lung meridian. There is no difference between the effects of smoking on the bioelectrical capacitance at left and right specific acupoints of lung meridian.

사각관 이상유동 분석을 위한 전기적 캐패시턴스 토모그라피 코드 개발 (Development of an Electrical Capacitance Tomography Code for Analysis of Two-Phase Flow in the Rectangular Pipe)

  • 이경황;이재영
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.87-94
    • /
    • 2005
  • A computer code for Electrical Capacitance Tomography (ECT) is developed to sense the cross sectional phase distribution of two-phase flow in the rectangular pipe in which the tomography sensor furnished by the insulated wall, electrodes, and electric field screen. The computer code had two steps for the image reconstruction. In the forward projection step, the sensitivity matrix was constructed based on the electric field calculated by the finite difference method. In the backward projection step, the sensitivity matrix and the measured capacitances were used to reconstruct the cross sectional image. Several algorithms including LBP, TR, ITR, and PLI were employed to find the proper one for the two-phase flow analysis. Since the dielectric constant of the water in two-phase flow is sensitive to the thermal parameter such as, temperature and pressure, the developed code was evaluated to find their accuracy, speed of calculation, and sensitivity to the variation of the dielectric constant. It was found that the iterative methods are superior to the direct methods for the image reconstruction, and the PLI method was the best in the variation of the dielectric constants.

Moving wall형 LB법으로 제작된 MLS DLPC LB 박막의 제작과 캐패시턴스 특성 (Capacitance properties of DLPC LB films with MLS structure fabricated by moving wall type method)

  • 이우선;정용호;손경춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1297-1299
    • /
    • 1998
  • LB layers of L-$\alpha$-DLPC deposited by LB method were deposited onto n-type silicon wafer as Z-type film. Films made up of 8, 16 layers of lipid with long alkyl chain and the thickness of monolayer and multilayers was determined by ellipsometry. It was deposited Ag and Al onto LB layers and silicon wafer for electrode and small electrode exhibit high capacitance and low leakage current. The C-V curves of the MLS capacitor shows very high saturation value of capacitance. And cross-sectional SEM image of MLS capacitor indicated the presence of pore with Al electrode and we found that the Ag is good for electrode metal.

  • PDF

K-PCS와 W-CDMA 듀얼밴드용 유전체 듀플렉서와 밴드패스 필터의 설계 및 제작 (Design and Fabrication of Dielectric Duplexer and Bandpass Filters for K-PCS and W-CDMA Dualband)

  • 최우성;양성현;김철주;문옥식
    • 한국전기전자재료학회논문지
    • /
    • 제25권12호
    • /
    • pp.949-954
    • /
    • 2012
  • The K-PCS and W-CDMA dual band dielectric duplexer and bandpass filters have been designed and fabricated. The dual band duplexer consists of the separate monoblock K-PCS and W-CDMA duplexers using common antenna port. The coupling capacitance and I/O impedance matching have been designed to minimize the cross interference between the bands. Isolations of crosspoint between Tx and Rx in K-PCS and W-CDMA dualband were about 47 dB and 100 dB, respectively. On the other hand, isolations of Tx and Rx in K-PCS and W-CDMA were about 66 dB and 65 dB, respectively. The difference between 47 dB and 100 dB originated from the different center frequencies in Tx and Rx of K-PCS and W-CDMA bands. The coupling capacitance of the bandwidth, I/O capacitance of I/O matching and impedance matching, and various capacitances were important role to fabricate the dielectric duplexer and bandpass filters.

임의 단말을 가진 전송선의 회로정수 산출 (Computation of Circuit Parameters of Multiconductor Transmission Lines with Arbitrary Cross Section)

  • 김종민;김종해;하상욱;라극환
    • 대한전자공학회논문지
    • /
    • 제26권12호
    • /
    • pp.1918-1925
    • /
    • 1989
  • A method for computing the capacitance and inductance matrix for 2-D multiconductor transmission lines with arbitrary cross section in dielectric medium is presented. The integral equation is obtained by using a free space Green function in conjunction with free and bound charges existing on boundary surfaces. The numerical analysis is based on the moment method using point matching and Galerkin method. And kthe scheme to reduce memory and computation time is presented for symmetric structure.

  • PDF

Low-operating voltage Pentacene FETs with High dielectric constant polymeric gate dielectrics and its hyteresis behavior

  • Park, Chan-Eon
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.168-168
    • /
    • 2006
  • Low-operating voltage organic field-effect transistors (OFETs) have been realized with high dielectric constant (${\kappa}$) polymer such as cyanoethylated poly vinyl alcohol (CR-V, ${\kappa}=12$). Since the $high-{\kappa}$polymers are likely to contain water and ionic impurities, large hysteresis and considerable leakage current are frequently observed in OFETs. To solve these problems, we cross-linked the CR-V by using a cross-linking agent. Cross-linked CR-V dielectrics showed high dielectric constant of 11.1 and good insulating properties, resulting in a high capacitance ($81nF/cm^{2}$ at 1MHz) at 120 nm of dielectric thickness. Pentacene FETs with cross-linked CR-V dielectrics exhibited high carrier mobility ($0.72\;cm^{2}/Vs$), small subthreshold swing (185 mV/dec) and little hysteresis at low-operating voltage (${\Leq}-3V$).

  • PDF

고속 집적회로 시스템 설계에서 혼선잡음 최적화에 관한 연구 (Crosstalk optimization in high speed VLSI systems)

  • 김기범;신현철
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제30권5_6호
    • /
    • pp.265-272
    • /
    • 2003
  • 집적회로 시스템이 고집적화 됨에 따라 interconnection에서 인접한 두 신호선 에서 발생하는 cross-coupling capacitance에 의한 혼선잡음 때문에 logic fault나 delay fault가 일어날 수 있다. 현재 산업체에서 혼선잡음문제를 미리 발견하고 예방하는 방법이 없어서 모든 설계가 끝난 후 일일이 손으로 확인을 하고 사양을 만족하지 못하는 경우에는 설계수정을 하는 경우가 많았다 본 논문에서는 두 신호선간의 거리, 입력신호의 slew rate, 신호선의 두께, 신호선의 길이가 혼선잡음에 미치는 영향을 분석하고, 혼선잡음을 발생시키는 여러 요소에 대한 해결방안을 정리하여 제시하였고, noise에 대한 값을 table로 정형화하여 설계 최적화를 쉽게 수행할 수 있도록 하였다.

Metal-Insulator-Metal 캐패시터의 응용을 위한 비정질 BaTi4O9 박막의 전기적 특성 (Electrical Properties of the Amorphous BaTi4O9 Thin Films for Metal-Insulator-Metal Capacitors)

  • 홍경표;정영훈;남산;이확주
    • 한국재료학회지
    • /
    • 제17권11호
    • /
    • pp.574-579
    • /
    • 2007
  • Amorphous $BaTi_4O_9$ ($BT_4$) film was deposited on Pt/Si substrate by RF magnetron sputter and their dielectric properties and electrical properties are investigated. A cross sectional SEM image and AFM image of the surface of the amorphous $BT_4$ film deposited at room temperature showed the film was grown well on the substrate. The amorphous $BT_4$ film had a large dielectric constant of 32, which is similar to that of the crystalline $BT_4$ film. The leakage current density of the $BT_4$ film was low and a Poole-Frenkel emission was suggested as the leakage current mechanism. A positive quadratic voltage coefficient of capacitance (VCC) was obtained for the $BT_4$ film with a thickness of <70 nm and it could be due to the free carrier relaxation. However, a negative quadratic VCC was obtained for the films with a thickness ${\geq}96nm$, possibly due to the dipolar relaxation. The 55 nm-thick $BT_4$ film had a high capacitance density of $5.1fF/{\mu}m^2$ with a low leakage current density of $11.6nA/cm^2$ at 2 V. Its quadratic and linear VCCs were $244ppm/V^2$ and -52 ppm/V, respectively, with a low temperature coefficient of capacitance of $961ppm/^{\circ}C$ at 100 kHz. These results confirmed the potential suitability of the amorphous $BT_4$ film for use as a high performance metal-insulator-metal (MIM) capacitor.

Alternative Sample Preparation Method for Large-Area Cross-Section View Observation of Lithium Ion Battery

  • Kim, Ji-Young;Jeong, Young Woo;Cho, Hye Young;Chang, Hye Jung
    • Applied Microscopy
    • /
    • 제47권2호
    • /
    • pp.77-83
    • /
    • 2017
  • Drastic development of ubiquitous devices requires more advanced batteries with high specific capacitance and high rate capability. Large-area microstructure characterization across the stacks of cathode, electrolyte and anode might reveal the origin of the instability or degradation of batteries upon cycling charge. In this study, sample preparation methods to observe the cross-section view of the electrodes for battery in SEM and several imaging tips are reviewed. For an accurate evaluation of the microstructure, ion milling which flats the surface uniformly is recommended. Pros and cons of cross-section polishing (CP) with Ar ion and focused ion beam (FIB) with Ga ion were compared. Additionally, a modified but new cross-section milling technique utilizing precision ion polishing system (PIPS) which can be an alternative method of CP is developed. This simple approach will make the researchers have more chances to prepare decent large-area cross-section electrode for batteries.

Penicillin-G 첨가 배지에서 배양한 코리네형 세균의 전기장 충격법에 의한 고효율 형질전환 (High Frequency Electroporation-transformation of Coryneform Bacteria Grown in the Medium with Penicillin-G)

  • 노갑수;김성준
    • KSBB Journal
    • /
    • 제6권3호
    • /
    • pp.223-230
    • /
    • 1991
  • Using the shuttle vector pECCGl between Escherichia coli and Corynebacterium glutamicum and C. glutamicum strain JS231 grown in the medium supplemented with penicillin-G, which inhibits the formation of cross-links in the peptidoglycan of bacterial cell wall, various parameters involved in electroporation system including resistance, electric field strength, capacitance, DNA concentration, and cell density were investigated independently and optimized for the high efficiency transformation of coryneform bacteria. Using cells grown with 0.3U/ml of penicillin-G and harvested at A600 of 0.7-0.8, transformation efficiencies of 107-l08 transformants/$\mu\textrm{g}$ of DNA with Corynebcctertum glutamicum strain JS231 and wild type ATCC13032 were achieved under conditions of 12.5kV/cm of electric field strength, 400 ohms of resistance, $25\mu$F of capacitance, 3$\times$108 cells per transformation(1.2$\times$1010 cells/ml) and 100ng of plasmid DNA per transformation.

  • PDF