• Title/Summary/Keyword: Cross Capacitance

Search Result 71, Processing Time 0.038 seconds

A New Measurement Method of Dielectric Constants Applied the Principles of Cross Capacitance (Cross Capacitance 원리를 작용한 새로운 유전상수 측정방법 제안)

  • Kim, Han-Jun;Lee, Rae-Duk;Kang, Jeon-Hong;Yu, Kwang-Min;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1084-1087
    • /
    • 2002
  • The guard-ring type 3-terminal parallel plate electrodes proposed by ASTM D 150-81 and IEC 250 have been widely used for measurement of dielectric constants of solid dielectrics. However the method using this electrodes causes many uncertainty associated with the measurement errors of the diameter of the guarded electrode. the gap between guarded and guard-ring electrode. the distance of two active electrodes(the thickness of specimen), the roughness and contamination of surface of electrode and specimen. close adherence grade of electrode and specimen. In this paper. a new electrode system of cross capacitance type based on Thompson-Lampard theorem is designed and is employed for the measurement of dielectric constant. The results of simulation of guard-ring electrode and cross capacitance electrode using FEM program show that distance measurement between two electrodes in guard-ring electrode produces large uncertainty. on the other hand this effect in cross capacitance electrode is negligible. Furthermore. the air gap effects in the cross capacitance electrode is 5.6 times less sensitive than that in guard-ring electrode by assuming air gap of $50{\mu}m$.

  • PDF

Precise Measurement of Dielectric Constant Using Cross Capacitance Measurement Method (Cross Capacitance 측정법을 이용한 유전상수 정밀측정)

  • Kim, Han-Jun;Kang, Jeon-Hong;Yu, Kwang-Min;Lee, Sei-Hyun;Koo, Kyung-Wan;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1287-1288
    • /
    • 2007
  • The cross capacitor electrode system applied Thompson-Lampard theorem for precise and accurate measurement of dielectric constants is studied in this study. The capacitance derived from cross capacitor is calculated by the equation of ($C=\frac{{\epsilon}ln2}{\pi}{\cdot}$ effectivelength of electrode) which is very different from the equation of capacitance derived from parallel plate capacitor. From above mentioned reason, the capacitance measurement uncertainty of cross capacitor can be reduced then that of the parallel plate capacitor. the measurement dielectric constant measured by cross capacitor electrode method is one order more accurate and precise than that of 3-electrode method.

  • PDF

A Study on Calculation of Capacitance Parameter for Interconnection Line in Multilayer Dielectric Media (다층 유전체 매질에서의 Interconnection Line에 대한 Capacitance Parameter 계산에 관한 연구)

  • 김한구;곽계달
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.8
    • /
    • pp.1187-1196
    • /
    • 1989
  • In this paper, a method for computing the capacitance parameter for a multi-interconnection line in a multilayered dielectric region is presented. The number of interconnection lines and the number of dielectric layers are arbitrary, and the interconnection lines are finite cross section or infinite cross section. The surface of lines and dielectric interface are divided into subsection. The surface charge density of each subsection is a constant step-pulse function for each subsection. After the solution of surface charge density is effected by the method of moments, capacitance parameter is calculated.

  • PDF

The Effects of Smoking on Bioelectrical Capacitance Measured at Twelve Source Points: A Cross-Over Study (흡연이 십이원혈(十二原穴)의 체표 capacitance에 미치는 영향)

  • Kim, Yang-Seob;Park, Young-Chun;Yim, Yun-Kyoung
    • The Journal of Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.35-52
    • /
    • 2015
  • Objectives: The objective of this study was to investigate the effects of smoking on the skin bio-electrical capacitance at twelve source points. Methods: Twenty healthy male subjects were assigned to smoking and sham-smoking by a random cross-over design. Skin bio-electrical capacitance was measured at twelve source points for 10 minutes before and after smoking. The change of skin bio-electrical capacitance was analysed. Results: 1. The skin bio-electrical capacitance at LU9, PC7 and LR3 was significantly increased after smoking. 2. In the smoking group, the skin bio-electrical capacitance at the source points of Hand Yin meridians significantly increased compared to that of Foot Yin and Hand Yang meridians. Conclusions: Smoking significantly increased the skin bio-electrical capacitance at the source points of Lung, Pericardium and Liver meridians. Hand Yin meridians appear to be more vulnerable to smoking than other meridians.

Water Absorption Sensor of Generator Stator Bar Insulation using Cross Capacitance (크로스 커패시턴스를 이용한 발전기 고정자 권선 절연물 흡습 측정 센서)

  • Bae, Yong-Chae;Kim, Hee-Soo;Lee, Doo-Young;Lee, Wook-Ryun;Lee, Rae-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1972-1977
    • /
    • 2011
  • The mechanical integrity of generator stator windings is one of the critical point because the electric power is generated and conducted to power system through these windings. To cool down the heat emitted from generator winding during its operation, a majority of generators use de-mineralized water characterized by high cooling efficiency. Contrary to such the excellent cooling efficiency, however, the damaged bar insulations attributed to the absorption of cooling water in the generator stator winding lead to highly time- and cost consuming efforts as well as to service deterioration due to unexpected forced outage of generator. It is described that the new design of water absorption sensor using cross capacitance for generator in power plant in order to increase the reliability of water absorption diagnostics for generator stator bar insulation.

Mutual Coupling Capacitance and Cross-talk in TFT-LCD

  • Yun, Young-Jun;Jung, Soon-Shin;Kim, Tae-Hyung;Roh, Won-Yeol;Choi, Jong-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.71-72
    • /
    • 2000
  • The design of large area thin film transistor liquid crystal displays (TFT-LCDs) requires consideration of cross-talks between the data lines and pixel electrodes. These limits are imposed by the mutual coupling capacitances present in a pixel. The mutual coupling capacitance causes a pixel voltage error. In this study, semi-empirical model, which is adopted from VLSI interconnection capacitance calculations, is used to calculate mutual coupling capacitances. With calculated mutual coupling capacitances and arbitrary given image pattern, the root mean square (RMS) voltage of pixel is calculated to see vertical cross-talk from the first to the last column. The information obtained this study can be utilized to design the larger area and finer image quality panel.

  • PDF

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

A new bit line structure minimizing coupling noise for DRAM (DRAM의 비트 라인 간 커플링 노이즈를 최소화한 오픈 비트 라인구조)

  • Oh, Myung-Kyu;Jo, Kyoung-Rok;Kim, Sung-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.6
    • /
    • pp.17-24
    • /
    • 2004
  • This paper describes a novel bit line structure to minimize coupling noise induced by coupling capacitance between bit lines. In DRAMs coupling capacitance is inherently present bit lines. As in submicron process the bit line space gets narrower. bit line coupling capacitance increases and this increased coupling capacitance sharply raises cross-talk noise. In this paper using different layers of metal for adjacent bit lines has been tested to reduces cross-talk noise and a novel bit line structure capable of reducing capacitance is introduced and verified.

Simulations of Capacitive Cross-talk Effects on TFT-LCD Operational Characteristics (TFT-LCD 특성에 미치는 Capacitive Cross-talk의 영향에 대한 시뮬레이션)

  • 윤영준;정순신;김태형;최종선
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.557-560
    • /
    • 1999
  • The design of large area thin film transistor liquid crystal displays (TFT-LCDs) requires consideration of cross-talks between the data lines and pixel electrodes. These limits are imposed by the parasitic capacitive elements present in a pixel. The capacitive coupling of the data line signal onto the pixel causes a pixel voltage error. In this study semi-empirical capacitance model which is adopted from VLSI interconnection capacitance calculations was used to calculate mutual coupling capacitances. With calculated mutual coupling capacitances and given image pattern, the root mean square(RMS) voltage of pixel is calculated to see vertical cross-talk from the first to the last column. The information obtained from this study could be utilized to design the larger area and finer image quality panel.

  • PDF

Precision in situ Measurement using Non-Contacting Capacitive Sensor with 4-Electrodes (비접촉식 4-전극형 전기용량 센서를 이용한 in situ 정밀측정)

  • Kim, Jae-Yeol;Lee, Lae-Duck;Park, Ki-Hyung;Ma, Sang-Dong;Yang, Dong-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.3
    • /
    • pp.33-38
    • /
    • 2002
  • To establish the national standard of capacitance, four main electrodes of the cross capacitor which were evaluated to linearity and roundness less the $\pm 1 \mu m$ respectively have to be adjusted symmetrically in an inner cylinder. Four LM shafts with diameter of 5 mm were installed between main electrodes of the cross capacitor, and the electrodes were adjusted, as the first step, by means of the measured capacitance. In the second step, the symmetrical adjustment up to $\pm 1.2\mu m$ was performed by using a ball sensor, ball-type movable sensor, non-contacting capacitive sensor and upper guard sensor which were developed in this project.