• Title/Summary/Keyword: Critical control systems

Search Result 713, Processing Time 0.035 seconds

A Study on the Analysis and Control of Voltage Stability (전압안정성 분석 및 제어에 관한 연구)

  • 장수형;김규호;유석구
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.869-876
    • /
    • 1994
  • This paper presents an efficient method to calculate voltage collapse point and to avoid voltage instability. To evaluate voltage stability in power systems, it is necessary to get critical loading points. For this purpose, this paper uses linear programming to calculate efficiently voltage collapse point. Also, if index value becomes larger than given threshold value, voltage stability is improved by compensation of reactive power at selected bus. This algorithm is verified by simulation on the IEEE 14-bus sample system.

  • PDF

Development of simulation-based testing environment for safety-critical software

  • Lee, Sang Hun;Lee, Seung Jun;Park, Jinkyun;Lee, Eun-chan;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • v.50 no.4
    • /
    • pp.570-581
    • /
    • 2018
  • Recently, a software program has been used in nuclear power plants (NPPs) to digitalize many instrumentation and control systems. To guarantee NPP safety, the reliability of the software used in safetycritical instrumentation and control systems must be quantified and verified with proper test cases and test environment. In this study, a software testing method using a simulation-based software test bed is proposed. The test bed is developed by emulating the microprocessor architecture of the programmable logic controller used in NPP safety-critical applications and capturing its behavior at each machine instruction. The effectiveness of the proposed method is demonstrated via a case study. To represent the possible states of software input and the internal variables that contribute to generating a dedicated safety signal, the software test cases are developed in consideration of the digital characteristics of the target system and the plant dynamics. The method provides a practical way to conduct exhaustive software testing, which can prove the software to be error free and minimize the uncertainty in software reliability quantification. Compared with existing testing methods, it can effectively reduce the software testing effort by emulating the programmable logic controller behavior at the machine level.

Gearless Doubly-fed Induction Generator for Wind Power Generation (풍력발전용 기어리스 이중여자 유도 발전기)

  • Park, Taesik;Moon, Chaejoo;Kim, Seonghwan
    • Journal of IKEEE
    • /
    • v.21 no.1
    • /
    • pp.81-84
    • /
    • 2017
  • As the demands for offshore wind power generation systems on a large scale have grown dramatically, and extensive developments in PMSG (Permanent Magnet Synchronous Generator) and DFIG (Doubly-fed Induction Generator) wind turbine system have been going on. However, the wind power systems have been more sophisticated, and their reliability becomes critical issues. Averagely, wind turbines have shut down for about a week per year for repairs and maintenance. Especially the high speed gearbox of DFIG is inevitable components for high power generation, but becomes one of the critical failures. In this paper, a new reliable gearless wind turbine structure is proposed. The gearless wind turbine can operate on a maximum power points by controlling the speed of a rotational stator. The proposed approach is verified by PSIM simulations, resulting in increased energy reliability.

Malfunction detection in plasma etching process using EPD signal trace (EPD 신호검출에 의한 플라즈마식각공정의 이상검출)

  • 이종민;차상엽;최순혁;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1360-1363
    • /
    • 1996
  • EPD(End Point Detection) is used to decide etching degree of layer which must be removed at wafer etching process in plasma etching process which is one of the most important process in semiconductor manufacturing. In this thesis, the method which detects malfunction of etching process in real-time will be discussed. Several EPD signal traces are collected in normal plasma etching condition and used as reference EPD signal traces. Critical points can be detected by applying differentiation and zero-crossing techniques to reference EPD signal. Mean and standard deviation of critical parameters which is memorized from reference EPD signal are calculated and these determine the lower and higher limit of control chart. And by applying statical control chart to EPD signals which are collected in real etching process malfunctions of process are detected in real-time. By means of applying this method to the real etching process we prove our method can accurately detect the malfunction of etching process and can compensate disadvantage of current industrial method.

  • PDF

Modified method for auto-tuning of PID controller using relay feedback (릴레이 피드백을 이용한 개선된 PID 제어기 자동동조 기법)

  • 신창훈;윤명현;정학영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1004-1007
    • /
    • 1996
  • Various auto-tuning methods using relay feedback are presented recently. They are composed of the consecutive procedures identifying Nyquist critical point using relay feedback and designing PID controller by one point of Nyquist plot mapping. This paper suggests a strategy to get the knowledges of Nyquist critical point and the neighborhood point of it using relay feedback. The parameters of PID controller are established by dominant pole approximation based on these knowledges. Designers can make use of the damping ratio as a time domain specification. So design flexibilities are taken in view of stability and performance of the system response considering practical system condition.

  • PDF

Switching Angle Control of a High Speed Switched Reluctance Motor using an FPGA Circuit

  • Park, Changhwan;Kim, Vongdae;Park, Kyihwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.152.1-152
    • /
    • 2001
  • This paper presents a high performance and cost effective way by using an FPGA circuit to implement torque controller so that the SRM can operate at high speed. In order to increase the operating speed, we need to implement both the torque and the current controllers by using an FPGA. However, it is difficult to implement all of the torque controller in the FPGA. Moreover, implementation of a time critical part is sufficient for improving the performance. One of the time critical part is the switching angle control. In this study, torque controller which calculate the switching on and commutation angles is implemented in PC because these angle are a function of rotor velocity which is varied slowly, and switching angle controller ...

  • PDF

Study for the Information Operations for Long Unattended Periods of Time at the Space System

  • Kim, Han-Woong
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.4 no.2
    • /
    • pp.61-68
    • /
    • 2003
  • The space systems are being operated in a uncertain space environment and are desired to have autonomous capability for long periods of time without frequent telecommunications with the ground station. At the same time, requirements for new set of satellite system set of projects/systems calling for "autonomous" operations for long unattended periods of time are emerging. Since, by the nature of space systems, it is desired to perform its mission flawlessly and also it is of extreme importance to have fault-tolerant sensors and actuators for the purpose of validating science measurement data for the mission success. This studies focused on the identification/demonstration of critical technology innovations that will be applied to the Validation Control System.

Ant Colony Intelligence in Cognitive Agents for Autonomous Shop Floor Control (자율적 제조 공정 관리를 위한 인지 에이전트의 개미 군집 지능)

  • Park, Hong-Seok;Park, Jin-Woo;Hien, Tran Ngoc
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.8
    • /
    • pp.760-767
    • /
    • 2011
  • The flexibility and evolvability are critical characteristics of modern manufacturing to adapt to changes from products and disturbances in the shop floor. The technologies inspired from biology and nature enable to equip the manufacturing systems with these characteristics. This paper proposes an ant colony inspired autonomous manufacturing system in which the resources on the shop floor are considered as the autonomous entities. Each entity overcomes the disturbance by itself or negotiates with the others. The swarm of cognitive agents with the ant-like pheromone based negotiation mechanism is proposed for controlling the shop floor. The functionality of the developed system is proven on the test bed.

Basic Requirements for the Application of Risk Concept on Railway Safety Improvements (첨단 경량전철 열차제어시스템 안전엔지니어링 기술동향)

  • Cho Yun-Ok;Wang Jong-Bae;Kim Sang-Ahm
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1467-1473
    • /
    • 2004
  • It requires different safety programs from those of the typical train control systems to develop AGT systems applying train control system based on communication technology. Especially Advanced LRT system involves the processes that have the various safety functions being conducted by softwares and also have characteristics that should have special interest in validation of interface specification. The core items for the safety engineering for LRT control systems are hardware & software engineering, safety-critical system safety engineering, application software validation & verification technologies. In this paper the trends of the technologies for the mentioned core-items are described.

  • PDF

An Allocation Strategy for Direct Load Control Program Resources in Power Systems (전력계통운전상황을 고려한 직접부하제어자원의 배분전략)

  • Cho, K.S.;Lee, C.J.;Park, J.B.;Shin, J.R.;Kim, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.444-446
    • /
    • 2003
  • This paper deals with an allocation strategy for the resources of direct load control program, which is considered the operating states in power systems. The existing approaches, load shedding priority algorithm, curtailment payback based algorithm and mixed curtailment algorithm, are based on the uniform allocation strategy. These approaches are not taken into account the operating states in power systems. So, under the critical operating condition, direct load control resource is evaluated by introducing the congestion factor.

  • PDF