• Title/Summary/Keyword: Critical Tension

Search Result 395, Processing Time 0.025 seconds

Molecular Area and Interfacial Tension Behavior of Span 20 and Tween series surfactants at water/air interface (Span 20과 Tween계 계면활성제의 물/공기 계면에서의 분자면적과 계면장력 거동)

  • 김천희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.7
    • /
    • pp.1065-1072
    • /
    • 2000
  • The molecular areas and the interfacial tension behavior of ten nonionic surfactants, i.e., Span 20 and Tween 20, 40, 60. 80, 21, 61, 81, 65, & 85 are tested to assay their effects on the wetting and liquid retention properties of hydrophilic and hydrophobic fibrous materials. The molecular areas at water/air interface are derived from Gibbs’adsorption equations. The following conclusions are drawn from the results: 1) Span 20 is efficient in lowering the interfacial tension and effective in adsorption at the water/air interface, resulting in the low interfacial tension at critical micelle concentration (${\gamma}$$_{CMC}$) and a small molecular area($\omega$), 2) when the hydrophiles of the surfactants are constant, $\omega$’s increase as hydrophobe carbon numbers of the surfactants increase, 3) when the hydrophobes are constant, ${\gamma}$$_{CMC}$’s and $\omega$’s increase as the hydrophile ethylene oxide units increase, indicating effectiveness and efficiency is parallel in this case, 4) the ethylene oxide unit length as a hydrophile has greater influence on u than the hydrophobe chain length.han the hydrophobe chain length.gth.

  • PDF

Study on Eigenvalue Analysis for a Towed Cable - Free Boundary at the Bottom End (예인되는 케이블의 고유치 해석에 관한 연구 - 하부 끝단 자유 경계조건)

  • Jung, Dong-Ho;Kim, Hyeon-Ju;Moon, Deok-Soo;Lee, Seung-Won
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.74-80
    • /
    • 2009
  • In this study, the static and modal analyses to find the characteristic of eigenvalues for a towed cable were with a free boundary condition at the bottom end carried out with numerical study. The resulting numerical code with finite element method was used to study sample problems for a cable with towing speeds. After tracing the equilibrium state with a towing speed through the static analysis, modal analysis on the basis of static results was performed. The static top tension for a critical towing speed is nearly 50 percent of what it was for a free hanging pipe. From static analyses, it is found that towing speed has a noticeable effect on top tension of a towed pipe. At a high towing speed, differences between the first and second periods become larger. Compared to the fundamental period for a free hanging pipe, that for a towed pipe with a critical towing speed is approximately 1.4 times larger. This result is very important point in that the lock in condition and tension of the towed cable system with top excitation can be predicted. The corrected close form solution to solve natural periods for a towed cable was presented in this study. The code is validated by comparison of the results of theoretical and numerical studies. Two results were in very good agreement. This study can contribute to predicting the lock-in condition and tension for a towed cable or pipe with top excitation.

Studies on the Characteristics of EVA Foam by Solvent Treatment (용매 처리에 의한 EVA foam 표면 특성에 관한 연구)

  • Chun, Jae Hwan;Kim, Gu Ni;Hong, Soon Yeong;Yoo, Chong Sun;Oh, Sang Taek
    • Journal of Adhesion and Interface
    • /
    • v.2 no.3
    • /
    • pp.9-15
    • /
    • 2001
  • To estimate the effect of the surface state of the EVA foam on an adhesion, the surface was treated with solvents having different values of a solubility parameter and a surface tension. The morphology and the contact angle were measured by SEM and contact angle tester, respectively. The value of the critical surface tension(${\gamma}_{c,0}$) of the EVA foam calculated by Zismann plot was 27.08 dyne/cm. The surface state and the ${\gamma}_c$ of the EVA foam were changed by solvent treatment. The swelling ratio of EVA foam was influenced by solubility parameter of a solvent, on the other hand the degree of change in the surface state was dependent on a surface tension of a solvent. When a surface tension of solvent. When a surface tension of solvent is lower than ${\gamma}_{c,0}$ of the EVA foam, the wettability of a solvent was good and the surface state was greatly changed. The adhesion strength of EVA foam was greatly improved to above 600% as compared to that of the untreated one. As the ${\gamma}_c$ of EVA was closed to the surface tension of the primer, the good adhesion strength was obtained.

  • PDF

The Study for Surface Activity of Alkylquinolinium Halide Ⅰ. The Critical Micelle Concentration of Solution of Dodecylquinolinium Bromide (Alkylquinolinium Halide의 계면활성에 관한 연구 Ⅰ. Dodecylquinolinium Bromide 수용액의 Critical Micelle Concentration)

  • Lee Chong-Man
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.4
    • /
    • pp.205-207
    • /
    • 1972
  • Dodecylquinolinium bromide has been synthesized and the critical micelle concentrations of it in the aqueous solution have been determined by the measurement of the surface tension and the electrical conductance. The values are $3.34 {\times} 10^{-3}mole/l$ and 3.41 {\times} $10^{-3}$mole/l, respectively. Since dodecylquinolinium bromide has the larger hydrophobic group than dodecylpyridinium bromide, it is considered that the former has the smaller critical micelle concentration than the latter.

  • PDF

Estimation of a tensile force in a cable using dynamic characteristics (진동특성을 이용한 케이블의 인장력 산정)

  • Choi, Sang-Hyun;Nam, Dong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.461-467
    • /
    • 2007
  • Exact application of the tensile force is critical to high-tension members in civil engineering structures, and thus actual tensile forces have often been estimated in field. To date, a few methodologies have been presented utilizing static and/or dynamic responses of tension members. Each of these methods has its disadvantages as well as advantages in its procedures, accuracy, and equipment requirements. In this paper, the feasibility of a sensitivity based methodology, based on the relationship between the natural frequencies and the applied tensile force, developed by the authors, is verified using the measured data from a cable-stayed bridge structure. From the results, it is shown that the proposed method can be utilized in estimating the tensile force in tension member of a real structure.

  • PDF

A Study on the Dynamic Behavior of Concrete Dam by Shaking Table Tests (진동대 시험을 이용한 콘크리트 댐의 동적거동 특성 연구)

  • Hwang, Seong-chun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.7 s.100
    • /
    • pp.806-812
    • /
    • 2005
  • This paper adresses the shaking table tests with 1/100 scaled model followed similitude law for OOdam main designing section to understand nonlinear behavior characteristics of concrete dam body by ground motion. As earthquake wave, Hachinohe and El Centre waves were used and acceleration and displacements are measured to analyze behaviors of dam body. For maximum ground acceleration range $(0.3\~0.9 g)$, the results showed linear behavior regardless of maximum 9round acceleration and secured safety of structure. To analyze the behavior of dam after tension cracking, 3 cm-notch was placed at the critical section of over-flowing section. As results of applying Hachinohe wave(0.8 g), Even though tension cracks were formed at over-flowing section by Hachinohe wave(0.8 g), it showed that the dam is stable for supporting upper stream Part of water tank of dam.

characteristics of Biosurfactant Produced by Pseudomonas sp. EL-G527 from Activated Sludge

  • Lim, Eun-Gyoung;Cha, Mi-Sun;Park, Geun-Tae;Son, Hong-Joo;Lee, Sang-Joon
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.4
    • /
    • pp.221-225
    • /
    • 2000
  • Pseudomonas sp. EL-G527 was grown to produce a biosurfactant on 2% n-hexadecane as the energy and carbon source. This biosurfactant significantly reduced the surface tension of water from 72 to 28 dyne/cm at a critical micelle concentration(CMC) of 140 mg/l at pH 2.0. As the pH value decreased, the reduction in the surface tension due to the biosurfactant increased. The surface activity of the biosurfactant was unaffected when the NaCl concentration was increased to 5% and the calcium ion concentration increased to 100 mM, plus it remained stable at 10$0^{\circ}C$ for 180 min.

  • PDF

AC loss comparison of Bi-2223 and coated conductor HTS tapes under bending

  • Kim, Hae-Joon;Cho, Jeon-Wook;Sim, Ki-Deok;Kim, Jae-Ho;Kim, Seok-Ho;Jang, Hyun-Man;Lee, Soo-Gil
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.4
    • /
    • pp.41-45
    • /
    • 2007
  • Superconductor is developed for applications in high-power devices such as power-transmission cables, transformers, motor and generators. In such applications, HTS tapes are subjected to various kinds of stress or strain. AC loss is also important consideration for many large-scale superconducting devices. In the fabrication of the devices, the critical current $(I_c)$ of the high temperature superconductor degrades due to many reasons including the tension applied by bending and thermal contraction. These bending or tension reduces the $I_c$ of superconducting wire and the $I_c$ degradation affects the AC loss of the wire. The $I_c$ degradation and AC loss (self field loss) of Bi-2223 HTS and Coated conductor were measured under tension and bending conditions at 77K and self-field.

Flexural-Shear Failure Behavior in I-Shape RC Beams (I형 단면 RC보의 휨-전단파괴 거동에 관한 연구)

  • Moon, Jong-Soo;Yum, Hwan-Seok;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.377-380
    • /
    • 1999
  • This paper dscribes an experimental investigation into the cause of flexural-shear failure in RC beams. The experimental variables are bottom flange width and tension bar location. Then these test results were compared and analyzed to deduce the major cause of critical-shear cracking. As a result, it was found that the propagation of the critical shear crack depended exclusively on the intensity of horizontal cracking.

  • PDF

Evaluation of Longitudinal Steel Tension in Shear-Critical RC Beams (전단이 지배하는 RC 보의 주철근 인장력 산정)

  • Jeong, Jae-Pyong;Kim, Dae-Joong;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.252-255
    • /
    • 2004
  • The measured longitudinal reinforcement tensions in the shear-critical RC beams were significantly higher than the calculated values by the beam theory. This may be attributed to the reduction of the internal-moment arm length by the development of the arch action. In this paper, the measured longitudinal reinforcement tensions in the test performed by $Kim^4$ were compared with those predicted by the various truss model.

  • PDF