• Title/Summary/Keyword: Critical Incident

Search Result 145, Processing Time 0.025 seconds

Inner harbour wave agitation using boussinesq wave model

  • Panigrahi, Jitendra K.;Padhy, C.P.;Murty, A.S.N.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제7권1호
    • /
    • pp.70-86
    • /
    • 2015
  • Short crested waves play an important role for planning and design of harbours. In this context a numerical simulation is carried out to evaluate wave tranquility inside a real harbour located in east coast of India. The annual offshore wave climate proximity to harbour site is established using Wave Model (WAM) hindcast wave data. The deep water waves are transformed to harbour front using a Near Shore spectral Wave model (NSW). A directional analysis is carried out to determine the probable incident wave directions towards the harbour. Most critical threshold wave height and wave period is chosen for normal operating conditions using exceedence probability analysis. Irregular random waves from various directions are generated confirming to Pierson Moskowitz spectrum at 20m water depth. Wave incident into inner harbor through harbor entrance is performed using Boussinesq Wave model (BW). Wave disturbance experienced inside the harbour and at various berths are analysed. The paper discusses the progresses took place in short wave modeling and it demonstrates application of wave climate for the evaluation of harbor tranquility using various types of wave models.

병원의 위기관리 시스템 (Crisis Management System in Hospitals)

  • 김형진
    • 한국병원경영학회지
    • /
    • 제spc호
    • /
    • pp.85-95
    • /
    • 2016
  • This study is to introduce a comprehensive framework of a crisis management system developed at a prominent hospital in South Korea. Throughout recent decades, especially in the recent years, the way in which to cope with both internal and external challenges has been one of the most critical issues. Since the incident management system in the U.S. is acknowledged as the most advanced crisis management model in the world, a portion of this study refers to the Hospital Incident Command System(HICS) provided by the California Emergency Medical Services Authority(EMSA). Nevertheless, the framework suggested in this article was designed based on a distinctive Korean hospital setting. The main contents of this study are as follows; categorization of each type of crisis, organization of a crisis management team in a non-crisis or crisis state, crisis assessment by life cycle stage, and establishment of crisis management protocol. Even though many types of crises are unspecified, those can be categorized into external crisis, medical crisis, and utility & activity failure. A crisis management organization should be operated and consisted differently- depending on a crisis or non-crisis situation. From a life-cycle perspective, the range by which the crisis should be managed extends from pre-stage to post-stage of the crisis. It is important to set proper scenarios and manuals by crisis type to develop a crisis management framework of high quality. With continuous efforts, hospitals can prepare for the uncertainty to better concentrate on core business operations.

Integrated fire dynamic and thermomechanical modeling of a bridge under fire

  • Choi, Joonho;Haj-Ali, Rami;Kim, Hee Sun
    • Structural Engineering and Mechanics
    • /
    • 제42권6호
    • /
    • pp.815-829
    • /
    • 2012
  • This paper proposes a nonlinear computational modeling approach for the behaviors of structural systems subjected to fire. The proposed modeling approach consists of fire dynamics analysis, nonlinear transient-heat transfer analysis for predicting thermal distributions, and thermomechanical analysis for structural behaviors. For concretes, transient heat formulations are written considering temperature dependent heat conduction and specific heat capacity and included within the thermomechanical analyses. Also, temperature dependent stress-strain behaviors including compression hardening and tension softening effects are implemented within the analyses. The proposed modeling technique for transient heat and thermomechanical analyses is first validated with experimental data of reinforced concrete (RC) beams subjected to high temperatures, and then applied to a bridge model. The bridge model is generated to simulate the fire incident occurred by a gas truck on April 29, 2007 in Oakland California, USA. From the simulation, not only temperature distributions and deformations of the bridge can be found, but critical locations and time frame where collapse occurs can be predicted. The analytical results from the simulation are qualitatively compared with the real incident and show good agreements.

파력 발전기에 미치는 유체력의 제어에 관한 연구 (A Study on the Control of Hydrodynamic forces for Wave Energy Conversion Device Operating in Constantly Varying Ocean Conditions)

  • 김성근;박명규
    • 한국항해학회지
    • /
    • 제14권4호
    • /
    • pp.41-52
    • /
    • 1990
  • 부유식 진동수주형 파력발전기는 불규칙한 해상 상태에서의 작동으로 인하여 흡수효율의 저하를 필수적으로 수반한다. 본 논문에서는 입사파의 에너지를 적절히 흡수할 수 있는 파력발전기를 초기설계하여 모델로 이용하였으며, 이 모델의 유체력추정에는 3차원 특이점 분포법을 사용하였다. 그리고, 가변구조 시스템으로 알려진 슬라이딩 모드기법을 이용하여 파의 상태 변화에 따른 파력발전기의 자세와 위치를 제어함으로써 흡수파력의 효율을 중대시킬 수 있는 시스템을 제안하고 있다.

  • PDF

초음파 공진을 이용한 스틸 연소관의 내열 고무 두께 측정 기법 연구 (Study on Thickness Measurement about Insulation Rubber of Steel Motor Case Using Ultrasonic Resonance)

  • 김동륜;김재훈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.562-569
    • /
    • 2012
  • 기존의 펄스에코법은 스틸 연소관 내부에서 고무면으로 초음파를 입사시키므로 검사 도중에 고무면이 오염될 수 있으며, 이로 인해 치명적인 미접착 결함을 유발시킬 수 있다. 상기 방법을 보완할 수 있는 시험기법을 개발하기 위해 스틸/고무 접착 시험편을 제작하여 스틸면으로 초음파를 입사시켰다. 스틸/고무 접착 시험편으로부터 측정한 고무 공진 주파수는 이론적으로 예측한 공진 주파수와 일치하였다. 본 논문은 고무 공진 주파수를 이용하여 고무 두께를 측정할 수 있는 초음파 공진법에 대해 기술하였다.

  • PDF

Hole and Pillar Patterned Si Absorbers for Solar Cells

  • Kim, Joondong;Kim, Hyunyub;Kim, Hyunki;Park, Jangho
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.226-226
    • /
    • 2013
  • Si is a dominant solar material, which is the second most abundant element in the earth giving a benefit in the aspect in cost with low toxicity. However, the inherent limit of Si has an indirect band gap of 1.1 eV resulting in the limited optical absorption. Therefore, a critical issue has been raised to increase the utilization of the incident light into the Si absorber. The enhancement of light absorption is a crucial to improve the performances and thus relieves the cost burden of Si photovoltaics. For the optical aspect, an efficient design of a front surface, where the incident light comes in, has been intensively investigated to improve the performance of photon absorption. Lambertian light trapping can be attained when the light active surface is ideally rough to increase the optical length by about 50 compared to a planar substrate. This suggests that an efficient design may reduce thickness of the Si absorber from the conventional 100~300 ${\mu}m$ to less than 3 ${\mu}m$. Theoretically, a hole-array structure satisfies an equivalent efficiency of c-Si with only one-twelfth mass and one-sixth thickness. Various approaches have been applied to improve the incident light utilization in a Si absorber using textured structures, periodic gratings, photonic crystals, and nanorod arrays. We have designed hole and pillar structured Si absorbers. Four-different Si absorbers have been simultaneously fabricated on an identical Si wafer with hole arrays or pillar arrays at a fixed depth of 2 ${\mu}m$. We have found that the significant enhanced solar cell performances both for the hole arrayed and pillar arrayed Si absorbers compared to that of a planar Si wafer resulting from the effective improvement in the quantum efficiencies.

  • PDF

Peak seismic response of a symmetric base-isolated steel building: near vs. far fault excitations and varying incident angle

  • Pavlidou, Constantina;Komodromos, Petros
    • Earthquakes and Structures
    • /
    • 제18권3호
    • /
    • pp.349-365
    • /
    • 2020
  • Since the peak seismic response of a base-isolated building strongly depends on the characteristics of the imposed seismic ground motion, the behavior of a base-isolated building under different seismic ground motions is studied, in order to better assess their effects on its peak seismic response. Specifically, the behavior of a typical steel building is examined as base-isolated with elastomeric bearings, while the effect of near-fault ground motions is studied by imposing 7 pairs of near- and 7 pairs of far-fault seismic records, from the same 7 earthquake events, to the building, under 3 different loading combinations, through three-dimensional (3D) nonlinear dynamic analyses, conducted with SAP2000. The results indicate that near-fault seismic components are more likely to increase the building's peak seismic response than the corresponding far-fault components. Furthermore, the direction of the imposed earthquake excitations is also varied by rotating the imposed pairs of seismic records from 0◦ to 360◦, with respect to the major construction axes. It is observed that the peak seismic responses along the critical incident angles, which in general differ from the major horizontal construction axes of the building, are significantly higher. Moreover, the influence of 5% and 10% accidental mass eccentricities is also studied, revealing that when considering accidental mass eccentricities the peak relative displacements of the base isolated building at the isolation level are substantially increased, while the peak floor accelerations and interstory drifts of its superstructure are only slightly affected.

클라우드 환경에서의 ATT&CK 매트릭스 기반 이벤트 로그 분석 프레임워크 (Event Log Analysis Framework Based on the ATT&CK Matrix in Cloud Environments)

  • 김예은;김정아;채시윤;홍지원;김성민
    • 정보보호학회논문지
    • /
    • 제34권2호
    • /
    • pp.263-279
    • /
    • 2024
  • 클라우드 마이그레이션 증가와 함께 클라우드 컴퓨팅 환경에서의 보안 위협도 급증하고 있다. 이에 효율적인 사고조사를 수행하기 위한 로그 데이터 분석의 중요성이 강조되고 있다. 클라우드 환경에서는 서비스 다양성과 간편한 리소스 생성 등의 특성으로 인해 대량의 로그 데이터가 생성된다. 이로 인해 사고 발생 시 어떤 이벤트를 조사해야 하는지 판단하기 어렵고, 방대한 데이터를 모두 확인하려면 상당한 시간과 노력이 필요하다. 따라서 데이터를 효율적으로 조사하기 위한 분석체계가 필요하다. AWS(Amazon Web Services)의 로깅 서비스인 CloudTrail은 계정에서 발생한 모든 API 호출이벤트로그를 수집한다. 그러나 사고 발생 시 어떤 로그를 분석해야 하는지 판단하기 위한 인사이트 제공 역할은 부족하다. 본 논문에서는 Cloud Matrix와 이벤트 정보를 연계하여 사고 조사를 효율적으로 수행할 수 있도록하고, 이를 기반으로 사용자 행위 로그 이벤트의 발생 빈도 및 공격 정보를 동시에 확인할 수 있는 자동화 분석프레임 워크를 제안한다. 이를 통해 ATT&CK Framework를 기반으로 주요 이벤트를 식별하고, 사용자 행위를 효율적으로 파악함으로써 클라우드 사고 조사에 기여할 것으로 기대한다.

결정적 사건기법을 이용한 프리미엄 모빌리티 고객의 이용경험 구성요인 분석 (Configuration of Premium Mobility Customer's Experience Using a Critical Incident Technique)

  • 정혜인;홍석표;정남호
    • 지식경영연구
    • /
    • 제25권2호
    • /
    • pp.135-153
    • /
    • 2024
  • 최근 스마트관광도시의 등장으로 프리미엄 모빌리티가 중요한 관광분야의 교통수단으로 간주되고 있다. 그런데, 아직까지 관광목적으로 활용될 수 있는 프리미엄 모빌리티 이용고객의 이용경험에 대해서는 충분히 연구된 바가 없다. 이에 이 연구는 결정적 사건기법(critical incidents technique: CIT)을 이용하여 프리미엄 모빌리티를 이용했던 고객의 이용경험에 대한 구성요인을 분석하였다. 프리미엄 모빌리티 이용경험을 구성하는 요인을 구체적으로 파악하기 위해 총 273부의 온라인 설문조사를 통해 만족에 관한 사건수는 366건, 불만족에 관한 사건수는 13건을 수집하였다. 연구결과 고객이 프리미엄 모빌리티를 이용했던 경험을 바탕으로 CIT를 적용하여 프리미엄 이용경험 인식을 구성하는 6개 범주와 9개의 하위요인들을 도출하였다. 특히 이 연구는 6개의 범주 중 편리성이 새로운 범주로 추가되었고 9개의 하위요인 중 넓은 승차감과 고가성(高價性)은 새로운 하위요인으로 도출되었기에 기존 연구들과는 차별성이 있다. 따라서 향후 도출된 구성 요인들을 바탕으로 구조방정식과 같은 양적연구에서 활용될 수 있는 척도를 개발하고, 신뢰성과 타당성을 확보할 수 있다면 관광분야의 프리미엄 모빌리티와 관련된 주제에 다양하게 적용될 수 있을 것이다.

광굴절 격자에서 집속 판독빔에 의한 각도 선택 특성 분석 (Analysis of the Angular Selectivity due to the Focused Readout Beamin Photorefractive Grating)

  • 안준원;김남;이권연;이현재;서완석
    • 대한전자공학회논문지SD
    • /
    • 제37권9호
    • /
    • pp.31-37
    • /
    • 2000
  • 광굴절 부피격자에 집속되는 판독빔이 입사될 때 나타나는 각도 선태 특성을 기하학적으로 해석하고 실험결과를 제시하였다. 해석 결과 각도 선택 특성은 판독빔의 입사조건에 의해 결정되며, 기록빔의 입사조건에 독립적인 특성을 보였다. 제시된 각도 선택 특성 이론의 증명을 위해 기록빔의 입사각, 판독비의 폭, 집속렌즈의 초점거리에 대한 각도 선택 특성을 측정하였다. 실험 결과 기록빔의 외부 교차 반각이 8$^{\circ}$, 10$^{\circ}$, 14$^{\circ}$일 때의 각도 선택 특성은 각각 2.632$^{\circ}$, 2.618$^{\circ}$, 2.604$^{\circ}$로 기록 조건에 무관한 특성을 얻은 반면 동일한 기록빔의 입사각에 대해 판독빔의 폭을 9.7mm, 2.11mm로 조정한 경우 2.632$^{\circ}$, 1.588$^{\circ}$의 특성을 보임으로써 판독빔에 의해 각도 선택 특성 제어가 이루어짐을 볼 수 있었다.

  • PDF