• Title/Summary/Keyword: Critical Control Points

Search Result 175, Processing Time 0.027 seconds

Analysis of the Effects of Three Line Scanner's Focal Length Bias (Three Line Scanner의 초점거리 오차의 영향에 관한 연구)

  • Kim, Changjae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • The positions, attitudes, and internal orientation parameters of three line scanners are critical factors in order to acquire the accurate location of objects on the ground. Based on the assumption that positions and attitudes of the sensors are derived either from direct geo-referencing which of using Global Positioning Systems (GPS) and Inertial Navigation Systems (INS), or from indirect geo-referencing which of using Ground Control Points (GCPs), this paper describes on biased effects of Internal Orientation Parameter (IOP) on the ground. The research concentrated on geometrical explanations of effects from different focal length biases on the ground. The Synthetic data was collected by reasonable flight trajectories and attitudes of three line scanners. The result of experiments demonstrated that the focal length bias in case of indirect geo-referencing does not have critical influences on the quality of reconstructed ground space. Also, the relationships between IO parameters and EO parameters were found by the correlation analysis. In fact, the focal length bias in case of the direct geo-referencing caused significant errors on coordinates of reconstructed objects. The RMSE values along the vertical direction and the amount of focal length bias turned out to be almost perfect linear relationship.

Standard Chemotherapy with Excluding Isoniazid in a Murine Model of Tuberculosis (마우스 결핵 모델에서 Isoniazid를 제외한 표준치료의 예비 연구)

  • Shim, Tae Sun;Lee, Eun Gae;Choi, Chang Min;Hong, Sang-Bum;Oh, Yeon-Mok;Lim, Chae-Man;Lee, Sang Do;Koh, Younsuck;Kim, Woo Sung;Kim, Dong Soon;Cho, Sang-Nae;Kim, Won Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.3
    • /
    • pp.177-182
    • /
    • 2008
  • Background: Isoniazid (INH, H) is a key drug of the standard first-line regimen for the treatment of tuberculosis (TB), yet some reports have suggested that treatment efficacy was maintained even though INH was omitted from the treatment regimen. Methods: One hundred forty C57BL/6 mice were infected with the H37Rv strain of M. tuberculosis with using a Glas-Col aerosol generation device, and this resulted in depositing about 100 bacilli in the lung. Four weeks after infection, anti-TB treatment was initiated with varying regimens for 4-8 weeks; Group 1: no treatment (control), Group 2 (4HREZ): 4 weeks of INH, rifampicin (R), pyrazinamide (Z) and ethambutol (E), Group 3: 1HREZ/3REZ, Group 4: 4REZ, Group 5: 4HREZ/4HRE, Group 6: 1HREZ/3REZ/4RE, and Group 7: 4REZ/4RE. The lungs and spleens were harvested at several time points until 28 weeks after infection, and the colony-forming unit (CFU) counts were determined. Results: The CFU counts increased steadily after infection in the control group. In the 4-week treatment groups (Group 2-4), even though the culture was negative at treatment completion, the bacilli grew again at the 12-week and 20-week time points after completion of treatment. In the 8-week treatment groups (Groups 5-7), the bacilli did not grow in the lung at 4 weeks after treatment initiation and thereafter. In the spleens of Group 7 in which INH was omitted from the treatment regimen, the culture was negative at 4-weeks after treatment initiation and thereafter. However, in Groups 5 and 6 in which INH was taken continuously or intermittently, the bacilli grew in the spleen at some time points after completion of treatment. Conclusion: TThe exclusion of INH from the standard first-line regimen did not affect the treatment outcome in a murine model of TB in the early stage of disease. Further studies using a murine model of chronic TB are necessary to clarify the role of INH in the standard first-line regimen for treating TB.

A Quality Assurance Study for the Application of Cook/chill System in School Foodservice Operation (I) - Broiled Spanish Mackerel - (학교급식에 Cook/chill system 적용을 위한 품질보증연구(I) - 삼치구이 -)

  • Kwak, Tong-Kyung;Moon, Hye-Kyung;Park, Hye-Won;Hong, Wan-Soo;Ryu, Kyung;Chang, Hye-Ja;Kim, Sung-Hee;Choi, Eun-Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.3
    • /
    • pp.278-293
    • /
    • 1998
  • The purposes of this study were to develop Hazard Analysis Critical Control Point-based standardized recipe applicable to cook/chilled Broiled Spanish Mackerel in school foodservice operations and to establish reasonable shelf-life limits by assessing food quality during chilled storage period of 5 days. HACCP for the production of menu items was identified in simulation study. At each critical control point, time-temperature profile was recorded and microbiological analysis was done. Also chemical analyses and sensory evaluation were conducted for 5 days of chilled storage. The results of time-temperature measurement of Broiled Spanish Mackerel by each production phase showed satisfactory condition that met the standards. Broiled Spanish Mackerel showed excellent microbiological quality from raw ingredient phase ($TPC:2.58{\pm}0.12\;Log\;CFU/g$) to holding phase ($TPC:2.70{\pm}0.42\;Log\;CFU/g$). Coliform (0.84 Log MPN/g) and fecal coliform (0.84 Log MPN/g) were detected from marinating phase ($TPC:3.82{\pm}0.52\;Log\;CFU/g$). After heating, only few mesophiles were detected ($TPC:1.83{\pm}0.49\;Log\;CFU/g$). No psychrophiles, coliforms and fecal coliforms were detected. In the phases after rapid chilling, during chilled storage and after reheating and distribution, almost none of the above microbes were detected. Salmonella and Listeria monocytogenes were not detected in all production phases. The pH immediately after cooking was 6.65 and then increased significantly to 6.81 on the third day of chilled storage (p<0.001). Acid value did not show significant changes while total volatile based nitrogen (TVBN) dramatitically increased during storage periods (p<0.01). In the result of sensory evaluation, general acceptability points had been rated high in the first day of storage, and then, the points were decreased significantly on the third day (p<0.05). General acceptability points ranged from 8.86 to 10.68. Accordingly, Broiled Spanish Mackerel is highly recommendable cook/chill system. Considering the DHSS standards for storage, the ideal shelf-life recommended for Broiled Spanish Mackerel is within 4 days excluding cooking day. For Broiled Spanish Mackerel, critical control points were purchasing and receiving of frozen Spanish Mackerel, heating, chilling, chilled storage, reheating and distribution.

  • PDF

A Study on the 3-Dimensional Analysis by Bundle Adjustment in Close Range Photogrammetry (근접사진측량의 번들조정에 의한 삼차원 위치해석에 관한 연구)

  • 백은기;목찬상
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.6 no.2
    • /
    • pp.10-18
    • /
    • 1988
  • In the three-dimensional analysis and deformation analysis of large structures, efficient is the use of the multiple method of close range photogrammetry which approaches the object distance. This study analyzes the influence of errors according to the overlap, the control points, and the object distance, to solve the problems which are raised in the multiple method. A wall-board, 7 meters by 3 meters, was used as a test field on which a total of 225 unknown points were equally disposed. The photographs with changing the overlap and object distance were taken by P-31 camera system. a total of 143 negatives are used in this study for computing 3-dimensional coordinates and its standard errors, and bundle adjustment of strips and blocks developed with on-line system is applied. In case of decreasing the number of control points, simulation error increases but actual error decreases and increases again. Due to the changed of object distances Z error represents largely compared to X, Y error, but good results in Z can be obtained by increasing the redundancy. And simulation error or actual error shows best results at the endlap of about 70%. To sum up this study, approprate arrangement of control points and overlap is meaningful, and multiple method by short object distance will be widely used to precision and deformation analysis of critical structures.

  • PDF

Optical Constants and Dispersion Parameters of CdS Thin Film Prepared by Chemical Bath Deposition

  • Park, Wug-Dong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.4
    • /
    • pp.196-199
    • /
    • 2012
  • CdS thin film was prepared on glass substrate by chemical bath deposition in an alkaline solution. The optical properties of CdS thin film were investigated using spectroscopic ellipsometry. The real (${\varepsilon}_1$) and imaginary (${\varepsilon}_2$) parts of the complex dielectric function ${\varepsilon}(E)={\varepsilon}_1(E)+i{\varepsilon}_2(E)$, the refractive index n(E), and the extinction coefficient k(E) of CdS thin film were obtained from spectroscopic ellipsometry. The normal-incidence reflectivity R(E) and absorption coefficient ${\alpha}(E)$ of CdS thin film were obtained using the refractive index and extinction coefficient. The critical points $E_0$ and $E_1$ of CdS thin film were shown in spectra of the dielectric function and optical constants of refractive index, extinction coefficient, normal-incidence reflectivity, and absorption coefficient. The dispersion of refractive index was analyzed by the Wemple-DiDomenico single-oscillator model.

Unscented Kalman Filter For Aircraft Sensor Fault Detection

  • Kim, In-Jung;Kim, You-Dan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2335-2339
    • /
    • 2003
  • To prevent the critical situation due to the fault in the aircraft sensor system, the fault tolerant system with triple or quadruple redundancy can be made. However, if the faults are occurred in two or more than sensors simultaneously, the conventional fault detection process, such as cross-channel monitoring, may give the wrong fault alarm. For this case, we can detect the fault by estimating the state vector based on the system dynamics model, which is nonlinear for aircraft. In this paper, we propose the unscented Kalman filter to estimate the nonlinear state vector. This filter utilizes the so-called unscented transformation of sigma points featured the statistical characteristics of the random variable. For verification, we perform the simulations for F-16 aircraft with accelerometers, gyros, GPS and air data system.

  • PDF

Non-Destructive Evaluation of Separation and Void Defect of a Pneumatic Tire by Speckle Shearing Interferometry

  • Kim, Koung-Suk;Kang, Ki-Soo;Jung, Hyun-Chul;Ko, Na-Kyong
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1493-1499
    • /
    • 2004
  • This paper describes the speckle shearing interferometry, a non-destructive optical method, for quantitative estimation of void defect and monitoring separation defect inside of a pneumatic tire. Previous shearing interferometry has not supplied quantitative result of inside defect, due to effective factors. In the study, factors related to the details of an inside defect are classified and optimized with pipeline simulator. The size and the shape of defect can be estimated accurately to find a critical point and also is closely related with shearing direction. The technique is applied for quantitative estimation of defects inside of a pneumatic tire. The actual traveling tire is monitored to reveal the cause of separation and the starting points. And also unknown void defects on tread are inspected and the size and shape of defects are estimated which has good agreement with the result of visual inspection.

An Automatic Approach for Geometric Correction of Landsat Images

  • Hwang, Tae-Hyun;Chae, Gee-Ju;Park, Jong-Hyun
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.542-542
    • /
    • 2002
  • Geometric correction is a critical step to remove geometric distortions in satellite images. For correct geometric correction, Ground Control Points (GCPs) have to be chosen carefully to guarantee the quality of corrected satellite images. In this paper, we present an automatic approach for geometric correction by constructing GCP Chip database (GCP DB) that is a collection of pieces of images with geometric information. The GCP DB is constructed by exploiting Landsat's nadir-viewing property and the constructed GCP DB is combined with a simple block matching algorithm for efficient GCP matching. This approach reduces time and energy for tedious manual geometric correction and promotes usage of Landsat images.

  • PDF

A study on the fire risk analysis on the railway tunnel and subway area (철도터널 및 지하구간에서의 화재사고 위험성 분석 연구)

  • Wang Jong Bae;Hong Seon Ho;Kim Sang Ahm;Park Ok Jeong
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.271-276
    • /
    • 2003
  • In this paper, various hazard factors are reviewed on the train fire accident in railway tunnel and subway. In case studies of systematic risk evaluation on the tunnel fire accident, we have learned the critical fire safety points for accident prevention and damage reduction such as fire-endurance of infrastructure, mortality of heat & toxic smoke, emergency situation control and management of escape requirements etc.. These hazard analysis study will contribute for improving the railway fire-safety and establishing the long-tenn safety management plan.

  • PDF

Study on Low Heat Cements (저발열형 시멘트 개발에 관한 연구)

  • Choi, Jae-Woong;Ha, Jae-Dam;Kim, Dong-Seuk;Kim, Ki-Soo;Choi, Long
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.46-51
    • /
    • 1999
  • Mass concrete structures have many critical points in service. The cracks caused by the heat of hydration is the most serious problem, so that many method ot control cracks(precooling, postcooling, etc) have been applied to construction. But cooling methods take high cost and many installation and limits of field. Therefore it is useful to use the low heat hydration cements for low cost. This paper describes the characteristics of a low heat cement mixing the ternary components of cement(portland cement, blast furnace slag, fly ash) recently developed for mass concrete, belite cement, low heat slag cement(belite base) and fly ash cement (belite base). The objective of this paper is to study on low heat cement about initial compressive strength and hydration heat.

  • PDF