• Title/Summary/Keyword: Crimped Fiber

Search Result 29, Processing Time 0.025 seconds

Bond, Flexural Properties and Control of Plastic Shrinkage Cracking of Crimped type Synthetic Fiber Reinforced Cement Based Composites (Crimped Type 합성섬유로 보강된 시멘트 복합재료의 부착, 휨 및 소성수축균열제어 특성)

  • Won, Jong Pil;Park, Chan Gi;Lim, Dong Hee;Back, Chul Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6A
    • /
    • pp.1033-1039
    • /
    • 2006
  • The purpose of this study are to evaluated bond, flexural properties and control of plastic shrinkage cracking of crimped type synthetic fiber with amplitude 6 mm and height 1.8 mm reinforced cement based composites. Bond and flexural test were conducted in accordance with the JCI-SF 8 and JCI SF-4 standard, respectively. The plastic shrinkage cracking test was conducted for evaluating the effect of fiber in reducing shrinkage cracking in cement based composites. Test results indicated that the crimped typel synthetic fibers performed significantly better than the straight type fiber in terms of interface toughness and pullout load and the crimped type synthetic fibers improved the flexural toughness of concrete. Also, the increasing the crimped type synthetic fiber volume fraction from 0.00% to 1.00% improved the plastic shrinkage cracking resistance. Specially, the effect of control of plastic shrinkage cracking is excellent at the more than 0.5% fibre volume fraction.

Optimum Geometry Factor of Structural Synthetic Fibers (구조용 합성섬유의 최적형상함수 결정)

  • 원종필;임동휘;박찬기;한일영;김방래
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.474-482
    • /
    • 2002
  • The purpose of the study is to establish an optimum geometry and optimum geometry factor through bond test of a structural synthetic fiber, which fully utilizes matrix anchoring without fiber fracturing with the maximum pullout resistance. Seven deformed structural synthetic fibers with widely different geometries were investigated and pullout test was conducted. Included parameters are seven different types of fiber and two of mortar matrixes. The test result shows that the crimped type structural synthetic fiber is significant improvement in the interface toughness(pullout energy) and pullout load. The pullout test was performed with various size of crimped type structural synthetic fiber in order to invest optimum geometry factor, In the basis of the test results, optimum geometry factor is established such as D=b$^{{\alpha}0{\alpha}}$h$^{λ{\beta}}$.

A Study on the Dyeing and Physical Properties of Napping Knit Fabric using Latent Crimped Yarn (잠재권축사를 적용한 기모편성물의 염색 및 물성변화에 대한 연구)

  • Lee, Bum Hoon
    • Textile Coloration and Finishing
    • /
    • v.33 no.4
    • /
    • pp.182-190
    • /
    • 2021
  • The purpose of this study is to provide the dyeing and physical characteristics of napped knit fabrics composed of latent crimped yarn. The K/S values, dyeing fastness, thickness, bulkiness, and shrinkage characteristics of three knit fabrics were investigated. The original knit fabric (SK) was composed of 1ply latent crimped yarn (75/36) in the ground and PET DTY (70/100) in the pile loop, in order of napped process the napped knit fabric (SN) was napped SK fabric. In order to compare of latent crimped yarn content, the last knit fabric (DN) was napped 2ply latent crimped yarn were included in the same structure of SK. Dyeability of three knit fabrics was similar but the shrinkage properties of DN fabric were significant different. The bulkiness shows a tendency to increase the bulkiness as increasing the dyeing temperature, and the bulkiness of the SN was higher because of the napping process and optimal content of latent crimped yarn.

Flexural Toughness and Fatigue Behavior of Steel Fiber Reinforced Rapid-set Cement Concrete (강섬유보강 초속경시멘트 콘크리트의 휨인성 및 피로거동)

  • Lee, Bong-Hak;Hong, Chang-Woo;Kim, Dong-Ho
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.163-172
    • /
    • 1999
  • This study is conducted on the flexural toughness and flexural fatigue test to fine the mechanical properties of steel fiber reinforced rapid-set cement concrete. Experimental investigation is examined according to fiber contents(0, 0.4, 0.7, 1.0, 1.5%), fiber aspect ratio(58, 60, 83), fiber type (hooked, crimped fiber), and cement type (normal portland & rapid-set cement). The principal results obtained through this study are as follows; toughness and fatigue resistance tend to considerably increase with fiber contents, fiber aspect ration. And hooked fiber is improved better than crimped fiber. Concrete using rapid set cement is increased strength properties compared with concrete using normal portland cement, but relative strength properties behavior and fatigue resistance show a tendency to decrease a little.

  • PDF

Experimental & numerical investigation of mechanical properties in steel fiber-reinforced UHPC

  • Dadmand, Behrooz;Pourbaba, Masoud;Sadaghian, Hamed;Mirmiran, Amir
    • Computers and Concrete
    • /
    • v.26 no.5
    • /
    • pp.451-465
    • /
    • 2020
  • This paper presents experimental and numerical investigations on mechanical properties of ultra-high-performance fiber-reinforced concrete (UHPFRC) with four types of steel fibers; micro steel (MS), crimped (C), round crimped (RC) and hooked-end (H), in two fiber contents of 1% and 2% (by volume) and two lengths of 13 and 30 mm. Compression, direct tension, and four-point bending tests were carried out on four types of specimens (prism, cube, dog-bone and cylinder), to study tensile and flexural strength, fracture energy and modulus of elasticity. Results were compared with UHPC specimens without fibers, as well as with available equations for the modulus of elasticity. Specimens with MS fibers had the best performance for all mechanical properties. Among macro fibers, RC had better overall performance than H and C fibers. Increased fibers improved all mechanical properties of UHPFRC, except for modulus of elasticity, which saw a negligible effect (mostly less than 10%). Moreover, nonlinear finite element simulations successfully captured flexural response of UHPFRC prisms. Finally, nonlinear regression models provided reasonably well predictions of flexural load-deflection behavior of tested specimens (coefficient of correlation, R2 over 0.90).

An experimental investigation on the mechanical properties of steel fiber reinforced geopolymer concrete

  • Murali, Kallempudi;Meena, T.
    • Advances in concrete construction
    • /
    • v.12 no.6
    • /
    • pp.499-505
    • /
    • 2021
  • Geopolymer binders fascinate the attention of researchers as a replacement to cement binder in conventional concrete. One-ton production of cement releases one ton of carbon-dioxide in the atmosphere. In the replacement of cement by geopolymer material, there are two advantages: one is the reduction of CO2 in the atmosphere, second is the utilization of Fly ash and Ground granulated blast furnace slag (GGBFS) are by-products from coal and steel industries. This paper focuses on the mechanical properties of steel fiber reinforced geopolymer concrete. The framework considered in this research work is geopolymer source (Fly ash, GGBFS and crimped steel fibre) and alkaline activator which consists of NaOH and Na2SiO3 of molarity 8M. Here the Na2SiO3 / NaOH ratio was taken as 2.5. The variables considered in this experimental work include Binder content (360,420 and 450 kg/m3), the proportion of Fly ash and GGBS (70-30, 60-40 and 50-50) for three different grades of Geopolymer concrete (GPC) GPC 20, GPC 40 and GPC 60. The percentage of crimped steel fibres was varied as 0.1%, 0.2%, 0.3%, 0.4% and 0.5%. Generally, the inclusion of steel fibres increases the flexural and split tensile strength of Geopolymer concrete. The optimum dosage of steel fibres was found to be 0.4% (by volume fraction).

Displacement-recovery-capacity of superelastic SMA fibers reinforced cementitious materials

  • Choi, Eunsoo;Mohammadzadeh, Behzad;Hwang, Jin-Ha;Lee, Jong-Han
    • Smart Structures and Systems
    • /
    • v.24 no.2
    • /
    • pp.157-171
    • /
    • 2019
  • This study investigated the effects of the geometric parameters of superelastic shape memory alloy (SE SMA) fibers on the pullout displacement recovering and self-healing capacity of reinforced cementitious composites. Three diameters of 0.5, 0.7 and 1.0 mm and two different crimped lengths of 5.0 and 10.0 mm were considered. To provide best anchoring action and high bond between fiber and cement mortar, the fibers were crimped at the end to create spear-head shape. The single fiber cement-based specimens were manufactured with the cement mortar of a compressive strength of 84 MPa with the square shape at the top and a dog-bone shape at the bottom. The embedded length of each fiber was 15 mm. The pullout test was performed with displacement control to obtain monotonic or hysteretic behaviors. The results showed that pullout displacements were recovered after fibers slipped and stuck in the specimen. The specimens with fiber of larger diameter showed better displacement recovering capacity. The flag-shaped behavior was observed for all specimens, and those with fiber of 1.0 mm diameter showed the clearest one. It was observed that the length of fiber anchorage did not have a significant effect on the displacement recovery, pullout resistance and self-healing capacity.

The Dyeing Behavior of PET Bulky Yarn with Disperse Dyes (분산염료에 의한 폴리에스터 Bulky Yarn의 염색거동)

  • Lee, Bum Hoon
    • Textile Coloration and Finishing
    • /
    • v.30 no.2
    • /
    • pp.70-76
    • /
    • 2018
  • The dyeing behaviors of poly(ethylene terephthalate)(PET) bulky yarns, DTY(draw textured yarn) and SSY(latent crimped yarn), were investigated with different energy type disperse dyes compared with those of SDY(spin draw yarn). The maximum exhaustions of E-type disperse Red 60, Blue 56 and Yellow 54 on SSY were 99%, 94% and 93%, respectively. The maximum exhaustions of S-type disperse Red 179, Blue 79 and Orange 30 on SSY were 96%, 97% and 97%, respectively. The K/S values of SSY were significantly higher than those of DTY and SDY in all energy type of disperse dyes. The knit fabric composed of SSY became bulky at the end of high temperature dyeing process because of their thermal shrinkage property due to melt viscosity difference.

Bond Characteristics of Structural Synthetic Fibers (구조용 합성섬유 표면형상에 따른 부착특성)

  • 원종필;임동휘;박찬기;한일영;김방래
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.335-340
    • /
    • 2001
  • Recently in abroad, structural synthetic fiber developed, has been studied extensively as a substitute for steel fiber due to its properties such as corrosion-resistance, low density, good pumping, and in-place safety, etc. In this study, we conducted pull-out test, for seven different geometries of structural synthetic fibers and obtained optimum geometry for structural synthetic fiber which fully utilizes matrix anchoring without revealing fiber fracturing. According to pull-out test results, it was found that crimped type structural synthetic fiber give significant improvement in the interface toughness(roll-out enemy) and pull-out load.

  • PDF