• 제목/요약/키워드: Crack Mode

검색결과 891건 처리시간 0.027초

Experimental and numerical study on the structural behavior of Multi-Cell Beams reinforced with metallic and non-metallic materials

  • Yousry B.I. Shaheen;Ghada M. Hekal;Ahmed K. Fadel;Ashraf M. Mahmoud
    • Structural Engineering and Mechanics
    • /
    • 제90권6호
    • /
    • pp.611-633
    • /
    • 2024
  • This study intends to investigate the response of multi-cell (MC) beams to flexural loads in which the primary reinforcement is composed of both metallic and non-metallic materials. "Multi-cell" describes beam sections with multiple longitudinal voids separated by thin webs. Seven reinforced concrete MC beams measuring 300×200×1800 mm were tested under flexural loadings until failure. Two series of beams are formed, depending on the type of main reinforcement that is being used. A control RC beam with no openings and six MC beams are found in these two series. Series one and two are reinforced with metallic and non-metallic main reinforcement, respectively, in order to maintain a constant reinforcement ratio. The first crack, ultimate load, deflection, ductility index, energy absorption, strain characteristics, crack pattern, and failure mode were among the structural parameters of the beams under investigation that were documented. The primary variables that vary are the kind of reinforcing materials that are utilized, as well as the kind and quantity of mesh layers. The outcomes of this study that looked at the experimental and numerical performance of ferrocement reinforced concrete MC beams are presented in this article. Nonlinear finite element analysis (NLFEA) was performed with ANSYS-16.0 software to demonstrate the behavior of composite MC beams with holes. A parametric study is also carried out to investigate the factors, such as opening size, that can most strongly affect the mechanical behavior of the suggested model. The experimental and numerical results obtained demonstrate that the FE simulations generated an acceptable degree of experimental value estimation. It's also important to demonstrate that, when compared to the control beam, the MC beam reinforced with geogrid mesh (MCGB) decreases its strength capacity by a maximum of 73.33%. In contrast, the minimum strength reduction value of 16.71% is observed in the MC beams reinforced with carbon reinforcing bars (MCCR). The findings of the experiments on MC beams with openings demonstrate that the presence of openings has a significant impact on the behavior of the beams, as there is a decrease in both the ultimate load and maximum deflection.

자기 평활성 바닥 마감용 SBR 시멘트 모르타르의 인장부착강도 (Adhesive Strength in Tension of SBR-Modified Cement Mortar with Self-Flowability Material for Floor-Finishing)

  • 도정윤;소양섭
    • 콘크리트학회논문집
    • /
    • 제15권4호
    • /
    • pp.549-556
    • /
    • 2003
  • 시멘트 모르타르의 내마모성, 여러 피착체에 대한 부착성능, 내화학성, 내수성 등의 많은 성능을 개선시키는 데 폴리머 디스퍼젼은 매우 유용한 재료로서 본 실험에 사용한 SBR은 상업적으로 국내에서 생산되고 있는 시멘트 적용성이 우수한 재료이다. 본 실험에서는 시멘트 모르타르에 높은 유동성을 유도하여 자기 평활성을 가지도록 고유동화제와 SBR을 사용하여 시험체를 제작하였으며 SBR에 의한 시험체의 부착강도의 발현 특성을 파악하고자 하였으며 SBR에 의해 개질된 자기 평활성을 가지는 시멘트 모르타르는 재령의 증가에 따라 부착강도는 증가하는 현상을 보여주었으며 파괴형상을 보면 재령이 증가함에 따라 시험체에서 보다는 계면과 피착체에서 외부 인장력에 대하여 파괴가 일어났다. 현재 사무실, 공장, 주차장 등의 바닥 마감재로 널리 사용되고 있는 합성 고분자계 재료인 에폭시 수지나 폴리우레탄 제품은 연도변화가 심하여 가사시간이 상당히 짧다는 것을 확인할 수 있었으며 이에 반하여 본 연구의 시험체는 충분한 가사시간을 확보할 수 있는 이점을 가진 재료로 여겨진다.

전단 보강이 없는 FRP RC보의 파괴 거동 (Failure Behavior of FRP RC Beams without Shear Reinforcements)

  • 이재훈;손현아;신성진
    • 콘크리트학회논문집
    • /
    • 제22권2호
    • /
    • pp.199-208
    • /
    • 2010
  • FRP bar를 철근 대체제로 활용하기 위해서는 설계 기준의 확립이 시급하나 국내에서는 이 소재에 대한 기초 연구가 부족한 상황이다. 그러므로 2차에 걸쳐 전단보강이 없는 18개의 FRP RC와 4개의 기존 RC 실험체의 거동을 관찰하였다. 1차 실험은 휨 파괴 거동과 사용성 항목의 계측 자료 수집을 목적으로 시작되었다. 휨파괴를 유도하기 위하여 전단배근을 강화하는 대신 그로 인한 거동의 불확실성을 배제하기 위하여 전단지간비만을 조정하여 휨파괴를 유도하고, 전단배근을 사용하지 않기로 하였다. 실험 결과 거의 모든 실험체는 전단파괴 되었으며 실험계획에 적용한 ACI 440.1R과 CSA S806의 전단 강도식이 실제와 큰 편차가 있음을 확인하였다. 1차 실험의 결과를 근거로 2차 실험에서는 전단파괴거동을 집중적으로 관찰하였다. 표준 실험체의 제원은 길이 3,300 mm폭 ${\times}$ 800 mm ${\times}$ 유효깊이 200 mm, 순지간 2,800 mm, 전단지간 1,200 mm로 전단지간비는 6.0이며, 단순지지 조건으로 4점 재하실험을 수행하였다. 검토 변수에는 콘크리트 압축강도, 보강근의 종류 및 탄성계수, 전단지간비, 유효보강비, 다발 배근의 영향, 피복두께의 영향이 포함된다.

소형펀치시험에 의한 5종의 고강도 DP강 수소취성 평가 (Evaluation on Hydrogen Embrittlement of 5 Types of High Strength Dual Phase Steels by Small Punch Test)

  • 최종운;한경구;박재우;강계명
    • 한국가스학회지
    • /
    • 제18권5호
    • /
    • pp.40-46
    • /
    • 2014
  • 전기화학적 방법으로 수소 주입시킨 5종의 고강도 DP강의 수소취성화 정도를 소형펀치시험으로 평가하였다. SP시험 후 SP흡수에너지는, $200mA/cm^2$ 전류밀도 조건의 DP5 시험편에서 수소주입시간이 5hr에서 50hr으로 증가함에 따라 363 kgf-mm에서 209 kgf-mm로 현저히 저하되는 것을 알 수 있었다. 전류밀도와 수소주입시간의 증가에 따라 수소주입량과 SP에너지 저하는 선형적인 상관관계를 갖는 것으로 조사되었다. 또한 SP시험에 의해 생성된 bulb의 높이 변화는 1.79 mm에서 1.59 mm로 낮아지는 것으로 조사되었다. 이는 앞서의 SP 흡수에너지 결과와 유사한 경향으로 나타나, 수소취성평가의 지표로 활용 가능할 것으로 사료된다. 균열 파단부위의 SEM 관찰에서 수소주입량 증가에 따라 파단면은 취성파면 형태로 진행되는 것을 확인할 수 있었다.

Shear Behavior and Performance of Deep Beams Made with Self-Compacting Concrete

  • Choi, Y.W.;Lee, H.K.;Chu, S.B.;Cheong, S.H.;Jung, W.Y.
    • International Journal of Concrete Structures and Materials
    • /
    • 제6권2호
    • /
    • pp.65-78
    • /
    • 2012
  • An experimental study was carried out to evaluate fresh properties of a moderately high-strength (high-flowing) self-compacting concrete (SCC) and to investigate shear behavior and performance of deep beams made with SCC. Fresh and hardened properties of normal concrete (NC) and SCC were evaluated. The workability and compacting ability were observed based on casting time and number of surface cavities, respectively. Four-point loading tests on four deep beams (two made with SCC and two with NC) were then conducted to investigate their shear behavior and performance. Shear behavior and performance of beams having two different web reinforcements in shear were systematically investigated in terms of crack pattern, failure mode, and load-deflection response. It was found from the tests that the SCC specimen having a normal shear reinforcement condition exhibited a slightly higher load carrying capacity than the corresponding NC specimen, while the SCC specimen having congested shear reinforcement condition showed a similar load carrying capacity to the corresponding NC specimen. In addition, a comparative study between the present experimental results and theoretical results in accordance with ACI 318 (Building Code Requirements for Reinforced Concrete (ACI 318-89) and Commentary-ACI 318R-89, 1999), Hsu-Mau's explicit method (Hsu, Cem Concr Compos 20:419-435, 1998; Mau and Hsu, Struct J Am Concr Inst 86:516-523, 1989) and strut-and-tie model suggested by Uribe and Alcocer (2002) based on ACI 318 Appendix A (2008) was carried out to assess the applicability of the aforementioned methods to predict the shear strength of SCC specimens.

유공형 강판으로 전단보강된 넓은 보에서의 횡방향 보강 간격에 따른 전단성능 평가 (Evaluation of Shear Capacity According to Transverse Spacing of Wide Beam Shear Reinforced with Steel Plate with Openings)

  • 최진웅;김민숙;최봉섭;이영학;김희철
    • 한국전산구조공학회논문집
    • /
    • 제28권3호
    • /
    • pp.259-266
    • /
    • 2015
  • 본 논문에서는 유공형 강판의 횡방향 보강간격에 따른 넓은 보의 전단성능을 실험적으로 평가하기 위하여 횡방향 전단보강 간격과 넓은 보의 유효깊이를 변수로 고려하였다. 시험체는 총 8개로 유공형 강판으로 전단보강한 시험체가 5개, 무보강 시험체가 3개이다. 균열 및 파괴유형, 변형률과 하중-변위 곡선을 분석하였다. 유공형 전단보강재의 전단강도 기여분을 분석하고, 횡방향 전단보강의 최대간격을 제안하였다. 횡방향 전단보강 개수가 2개인 시험체에 비해 3개인 시험체에서 전단강도가 크게 나타났으며 유효깊이가 증가할수록 전단강도가 크게 나타났다.

GFRP 판을 전단보강재로 사용한 넓은 보의 전단성능 평가 (Evaluation of Shear Strength for Wide Beam using GFRP Plate Shear Reinforcement)

  • 조은선;최진웅;김민숙;김희철;이영학
    • 한국전산구조공학회논문집
    • /
    • 제28권3호
    • /
    • pp.267-274
    • /
    • 2015
  • 본 논문은 넓은 보의 전단강도를 대상으로 한 실험적 평가에 대해 기술하였다. 본 논문의 실험을 통해 넓은 보에 횡방향 단면에서 GFRP 판의 보강개수와 종방향 전단보강 간격, 그리고 유효깊이가 전단강도에 끼치는 영향에 관하여 연구하였다. 총 7개의 시험체에 유공형 GFRP 판 형태로 전단보강재를 보강하여 전단성능 실험을 실시하였다. 본 논문에 기재된 전단보강재는 유공형 판 형태로 제작되어 타설 시 콘크리트의 유동성을 증가시켜 보강재와 콘크리트의 부착력을 향상시켰다. 7개 시험체의 주 변수로는 전단보강재의 횡방향 단면에 대한 판의 보강개수와 종방향 전단보강 간격, 그리고 유효깊이로 정하였다. 시험체의 균열 및 파괴 양상, 변형률과 전단강도비를 분석하였다. GFRP판으로 전단보강된 넓은 보의 전단강도는 ACI 318-11 기준으로 산정되었다. 실험의 결과를 통해 유공형 GFRP 판이 전단보강재로서 넓은 보에 효과적으로 적용됨을 확인하였다.

준설 점토사면의 변형양상에 관한 원심모델링 (Centrifuge Modeling on the Deformation Modes of Dredged Clay Slope)

  • 안광국;김정열;정소전;이처근
    • 한국지반환경공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.19-27
    • /
    • 2007
  • 본 연구에서는 준설에 따른 점토사면의 변형 및 변위양상과 파괴형태를 평가하기 위하여 준설사면의 기울기를 변화시키면서 원심모형실험을 실시하였다. 준설사면의 기울기는 1:2, 1:2.5, 1:3으로 변화시키면서 모형실험을 수행하였다. 실험 결과 기울기 1:3인 경우에는 4개월 경과시점까지 사면부내에서 변위는 발생되었지만, 초기단면과 유사하게 사면을 유지하고 있어 준설후 사면 안정성의 확보에는 문제가 없는 것으로 평가되었다. 준설사면 기울기가 1:2.5인 경우에는 4개월 경과시점에서 사면부내에서 국부적인 사면파괴가 발생하였으며, 기울기가 1:2인 사면의 경우 경과시간 2개월 후 원호파괴형태의 사면내 파괴가 발생되었다. 실험결과 지반의 최대 연직변위는 사면의 비탈머리에서 발생하였으며, 최대 수평변위는 비탈머리를 기준으로 0.5~1H(H : 초기 점토층의 높이) 떨어진 지점의 사면부 아래에서 발생하였으며, 최대 수평변위는 최대연직변위의 약 2배 정도인 것으로 나타났다.

  • PDF

Structural health monitoring of seismically vulnerable RC frames under lateral cyclic loading

  • Chalioris, Constantin E.;Voutetaki, Maristella E.;Liolios, Angelos A.
    • Earthquakes and Structures
    • /
    • 제19권1호
    • /
    • pp.29-44
    • /
    • 2020
  • The effectiveness and the sensitivity of a Wireless impedance/Admittance Monitoring System (WiAMS) for the prompt damage diagnosis of two single-storey single-span Reinforced Concrete (RC) frames under cyclic loading is experimentally investigated. The geometrical and the reinforcement characteristics of the RC structural members of the frames represent typical old RC frame structure without consideration of seismic design criteria. The columns of the frames are vulnerable to shear failure under lateral load due to their low height-to-depth ratio and insufficient transverse reinforcement. The proposed Structural Health Monitoring (SHM) system comprises of specially manufactured autonomous portable devices that acquire the in-situ voltage frequency responses of a network of twenty piezoelectric transducers mounted to the RC frames. Measurements of external and internal small-sized piezoelectric patches are utilized for damage localization and assessment at various and increased damage levels as the magnitude of the imposed lateral cycle deformations increases. A bare RC frame and a strengthened one using a pair of steel crossed tension-ties (X-bracing) have been tested in order to check the sensitivity of the developed WiAMS in different structural conditions since crack propagation, damage locations and failure mode of the examined frames vary. Indeed, the imposed loading caused brittle shear failure to the column of the bare frame and the formation of plastic hinges at the beam ends of the X-braced frame. Test results highlighted the ability of the proposed SHM to identify incipient damages due to concrete cracking and steel yielding since promising early indication of the forthcoming critical failures before any visible sign has been obtained.

노출강연선으로 보강된 하이브리드 건축용 OCB보의 실물모형 재하실험연구 (The Experimental Study of Full-scale Optimized Composite Beam (OCB) Reinforced with Open Strands)

  • 이두성;김태균;채규봉
    • 콘크리트학회논문집
    • /
    • 제27권5호
    • /
    • pp.471-480
    • /
    • 2015
  • 최근 국내의 건축구조는 공간활용을 극대화할 수 있도록 계획되고 있다. 공간활용의 장점을 실현하기 위하여 하이브리드 OCB (Optimized Composite Beam)를 개발하였다. 건축용 OCB는 부모멘트 구간에서는 노출강연선으로 보강된 H형강으로 구성되고 정모멘트 영역에서는 PSC 구조로 구성된다. 본 연구에서는 건축용 OCB의 휨성능을 조사하였다. 15 m 길이의 시험체를 제작하여 3점 휨실험을 실시하였다. 실험을 통해서 다음과 같은 결과를 얻었다. 1) 시험체의 재하실험에서 초기 균열은 설계사용 하중의 171%에서 발생되었다. 2)사용하중에서 처짐은 건축구조설계기준에 제시된 허용처짐량 이내로 만족하였다. 3)균열의 양상, 파괴모드 그리고 극한하중 등의 실험결과는 3D 수치해석결과와 비교검토되었다. 본 실험연구 결과로부터 건축용 OCB보의 구조적인 신뢰성이 입증되었다.