• Title/Summary/Keyword: Cp-Ti

Search Result 184, Processing Time 0.026 seconds

Corrosion Behavior of Titanium for Implant in Simulated Body Fluids (인공 체액 조건에서 임플랜트용 티타늄 소재의 부식 특성)

  • 이중배;최기열
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.2
    • /
    • pp.110-118
    • /
    • 2004
  • The corrosion of pure titanium (CP- Ti Grade 2) and titanium alloy (Ti6Al4V ELI) were studied under various conditions of simulated body fluids. The static immersion test and the electrochemical test were performed in accordance with ISO 10271 : 2001. For the electrochemical test, the open circuit potential was monitored as a function of time, and the cyclic polarization curve was recorded. The corrosion resistance was evaluated from the values of corrosion potential, passivation current density, breakdown potential, and the shape of hysteresis etc. The effects of alloy type, surface condition, temperature, oxygen, and constituents in the fluids such as acid, chloride were estimated. Both specimens had extremely low dissolution rate in the static immersion test. They showed strong passivation characteristics in the electrochemical test. They maintained negligible current density throughout the wide anodic potential range. The passive layer was not broken up to 2.0 V (vs. SCE). The hysteresis and the shift of passivation potential toward the anodic direction was observed during the reversed scan. The passivation process appeared to be accelerated by oxygen in air or that dissolved in the fluids. The passivation also proceeded without oxygen by the reaction of constituents in the fluids. Acid or chloride in the fluids, specially later weakened the passive layer, and then induced higher passivation current density and less shift of passivation potential in the reversed scan. CP-Ti Grade 2 was more reactive than Ti6Al4V ELI in the fluids containing acid or chloride, but thicker layer produced on its surface provided higher corrosion resistance.

Shear bond strength of composite resin to titanium according to various surface treatments

  • Lee, Seung-Yun;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.68-74
    • /
    • 2009
  • STATEMENT OF PROBLEM. When veneering composite resin-metal restoration is prepared, the fact that bond strength between Ti and composite resin is relatively weak should be considered. PURPOSE. The purpose of this study is to evaluate the shear bond strength between the veneering composite resin and commercial pure (CP) Ti / Ti-6Al-4V alloy according to the method of surface treatment. MATERIAL AND METHODS. The disks were cast by two types of metal. Their surfaces were treated by sandblasting, metal conditioner, TiN coating and silicoating respectively. After surface treatment, the disks were veneered by composite resin (Tescera$^{TM}$, Bisco, USA) which is 5 mm in diameter and 3 mm in thickness. The specimens were stored in water at $25^{\circ}C$ for 24 hours, and then evaluated for their shear bond strength by universal testing machine (STM-$5^{(R)}$, United Calibration, USA). These values were statistically analyzed. RESULTS. 1. All methods of surface treatment were used in this study satisfied the requirements of ISO 10477 which is the standard of polymer-based crown and bridge materials. 2. The metal conditioner treated group showed the highest value in shear bond strength of CP Ti, silicoated group, TiN coated group, sandblasted group, in following order. 3. The silicoated group showed the highest value in shear bond strength of Ti-6Al-4V alloy, metal conditioner treated group, sandblasted group, TiN coated group, in following order. CONCLUSION. Within the limitations of this study, all methods of surface treatment used in this study are clinically available.

A study on the development of Ti-Cu-Ni-Si insert metal for Ti alloys (Ti합금 접합용 Ti-Cu-Ni-Si계 삽입금속의 개발에 관한 연구)

  • 김경미;우인수;강정윤;이상래
    • Journal of Welding and Joining
    • /
    • v.14 no.1
    • /
    • pp.47-56
    • /
    • 1996
  • The purpose of this study is to develope an insert metal which can be brazed at lower temperature than the conventionally used insert metal and provide higher strength joint than base metal. In the review of binary phase diagram concerning Ti, Cu and Ni resulted in the discovery of Si having eutectic composition with them. The microstructure and the distribution of elements in reaction zone between CP Ti and insert metal were investigated by Optical Microscopy, SEM/EDX, EPMA, X-RAY. The newly developed insert metal is Ti-15wt%Cu-18wt%Ni-2wt%Si, which can yield the lower brazing temperature(1183K) compared with the conventional Ti-Cu-Ni system insert metal. The joints with this insert metal had tensile strength of 385MPa in the bonding temperature range of 1183K to 1243K.

  • PDF

Responses to Infection of Tobacco Mosaic Virus Pepper Strain (TMV-P) in Transgenic Tobacco Plants Expressing the TMV-P Coat Protein or Its Antisense RNA (담배 모자이크 바이러스 고추계통(TMV-P)의 외피단백질 유전자를 도입한 형질전환 담배의 TMV-P에 대한 반응)

  • 최장경;홍은주;이재열;장무웅
    • Korean Journal Plant Pathology
    • /
    • v.11 no.4
    • /
    • pp.374-379
    • /
    • 1995
  • The cDNA of tobacco mosaic virus-pepper strain (TMV-P) coat protein (CP) genes were introduced into tobacco plants (Nicotiana tabacum cv. Samsun nn) using a binary Ti plasmid vector of Agrobacterium tumefaciens. these cDNAs introduced into tobacco plants were detected by polymerase chain reaction. Symptom development was distinctly suppressed in the transgenic plant introduced buy sense CP cDNA when the plant was inoculated with TMV-P, while in transgenic tobacco plants of antisense CP gene, symptom development was not suppressed as in non-transgenic plants. TMV-P concentration in the sense CP transgenic tobacco plant was decreased to 1/14 of the concentration in non-transgenic plants. Expression of the kanamycin resistance gene of these transgenic plants could be detected in the progeny.

  • PDF

The Coating of Photocatalytic $TiO_2$on Metal and Glass using Alumina Sols as a Binder (금속 및 유리 기판 위에 알루미나 졸을 바인더로 한 $TiO_2$광 촉매의 코팅)

  • 석상일;안복엽;최경훈;서태수;유영문
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.7
    • /
    • pp.621-627
    • /
    • 2001
  • 알루미나 졸에 평균 25nm의 TiO$_2$(Degussa P25) 광 촉매 분말을 분산하여 광촉매 코팅제를 제조하였다. 점도 약 24 cps를 가지 4.4 wt%의 알루미나 졸로부터 약 300nm 두께의 코팅막이 제조되었으며, 졸 점도의 증가에 비례하여 코팅막의 두께도 증가하였다. TiO$_2$광 촉매의 코팅용 바인더로 이용한 알루미나 졸의 결정형은 25~30$0^{\circ}C$에서 pseudo boehmite (AlOOH)이었으며, 50$0^{\circ}C$ 이상에서는 ${\gamma}$-Al$_2$O$_3$으로 전환되었다. AlOOH/TiO$_2$코팅막은 oleic acid와 humic acid에 대한 기상 및 수상 조건에서의 광 촉매 실험에서 우수한 유기물의 광분해 효능을 나타내었다. 아울러 EGI(Electro-Galvanized Iron)에 코팅된 AlOOH/TiO$_2$코팅막은 내식성 및 내지문성의 효과도 부수적으로 나타내었다.

  • PDF

Fabrication of functionally graded materials of hydroxyapatite and titanium (Hydroxyapatite 와 titanium의 경사 기능 재료 제조)

  • 김성진;박지환;조경식;박노진
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.12 no.3
    • /
    • pp.144-148
    • /
    • 2002
  • Hydroxyapatite/titanium composites were prepared as 4-layered functionally graded materials (FGM) using a spark plasma sintering (SPS) apparatus. The maximum density and the biaxial strength of hydroxyapatite/titanium composites were achieved by SPS with a holding time 8 minutes at $1200^{\circ}C$. However, the hydroxyapatite was decomposed tetracalcium phosphate (TetCP) at $1100^{\circ}C$, and calcium titanate compounds ($CaTiO_3$) were formed. When titanium was added to hydroxyapatite, decomposition of hydroxyapatite was occurred easily at the low temperature.

Preparation and characterization of zirconium nitride and hydroxyapatite layered coatings for biomedical applications

  • Nathanael, A. Joseph;Lee, Jun-Hui;Hong, Sun-Ik
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.102.2-102.2
    • /
    • 2012
  • Different layers of zirconium nitride (ZrN) and hydroxyapatite (HA) coatings were prepared on cp Ti substrate for biomedical applications. The main idea is to improve the mechanical strength as well as the biocompatibility of the coating. ZrN is known for its high mechanical strength, corrosion resistance. HA is well known for its biocompatibility properties. Hence, in this study, both materials were coated on a cp Ti substrate with bottom layer with ZrN for good bonding with substrate and the top layer with HA for induce bioactivity. Middle layer was formed by a composite of HA and ZrN. Detail analyses of the layered coatings for its structural, morphological, topographical properties were carried out. Then the mechanical property of the layered coatings was analyzed by nanoindentation. Biomimetic growths of apatite on the functionally graded coatings were determined by simulated body fluid method. This study provides promising results to use this kind of coatings in biomedical field.

  • PDF

Microstructure and Hardness of Ti-X%Cu(X=2,5,10) Alloys for Dental Castings (치과주조용 Ti-X%Cu(X=2,5,10)합금의 미세조직 및 경도)

  • Jung, Jong-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.31 no.3
    • /
    • pp.9-14
    • /
    • 2009
  • This study evaluated the mechanical properties of Ti-Cu alloys with the hope of developing an alloy for dental casting with better mechanical properties than unalloyed titanium. Ti-Cu alloys with four concentrations of Cu(2,5,10wt%) were made in an argon-arc melting furnace. The microstructure and micro-Vickers hardness were determined. X-ray diffraction pattern test was performed on the polished specimens. The microstructure of 2%Cu and 5%Cu alloys are shown acicular ${\alpha}Ti$ phase formed on the surfaces of previously formed $\beta$grains. The 10%Cu alloys has essentially a eutectoid structure; this structure includes lamella of ${\alpha}Ti$ and $Ti_2Cu$ phase that transformed from ${\alpha}Ti$ at the eutectoid temperature. The micro-Vickers hardness of CP Ti specimens was significantly(p<0.05) lower than that of any of the other alloys. Among the Ti-Cu alloys, the 10%Cu alloys exhibited a significantly(p<0.05) higher hardness value. but lower than that of Ti-6%Al-4%V alloy. From these results, it was concluded that new alloys for dental castings should be designed as Ti-Cu based alloys if other properties necessary for dental castings were obtained.

  • PDF