• Title/Summary/Keyword: Coupler system

Search Result 260, Processing Time 0.022 seconds

An adoption of the HFPD measuring system using directional coupler sensors to XLPE cable & accessories (방향성센서를 이용한 고주파 부분방전 측정시스템의 XLPE 케이블 및 접속함 적용)

  • Yu, In-Kee;Kim, Ki-Young;Jeong, Young-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1674-1676
    • /
    • 2002
  • In this paper, High Frequency PD measuring system using directional coupler sensors(DCS) is introduced. Especially the principles of the DCS and characteristics of the system are introduced. Evaluation of this system was carried by an adoption to the test circuit of 345kV XLPE $2000mm^2$ cable and EB-A, EB-G, PIJ, PNJ. In the test a PD measurement was carried out without shieldroom and under the on-line state and in the high frequency range at the remote site from the test object. The test result was satisfactory and this is due to the use of DCS and using a high frequency range and specific filter for radio and TV signal and low pass. This system can be used to the test of a new construction of cable and accessories and measuring of long-term deterioration of cable and accessories. And this will bring us the reliability of a power transmission.

  • PDF

One-Time Key Generation System for Agent Data Protection in Mobile Agent Systems (이동 에이전트의 데이타 보호를 위한 일회용 에이전트 키 생성 시스템)

  • Park, Jong-Youl;Lee, Dong-Ik;Lee, Hyung-Hyo;Park, Joong-Gil
    • Journal of KIISE:Information Networking
    • /
    • v.28 no.3
    • /
    • pp.309-320
    • /
    • 2001
  • This paper deals with security issues in a mobile agent system, especially protecting agent data from malicious agent servers. For this purpose, one-time key generation system, OKGS in short, is proposed. In OKGS, we integrate notions of a one-way hash function and a coupler. One-way function plays a major role in ensuring confidentiality and integrity of agent data. And the notion of a coupler is used to establish inter-relationship among consecutive encryption keys for agent data, i.e. all agent keys form a unidirectional chain. With these two features of OKGS, therefore, only the agent owner, who creates the agent bearing data, can decrypt and protect all the agent data which are gathered in the itinerary.

  • PDF

Design of Beam-forming Reader Antenna for Train Position Detection using RFID (RFID 시스템 이용한 열차 위치검지용 빔폭 가변형 RFID 리더안테나)

  • Ahn, Chi-Hyung;Cho, Bong-Kwan;Ryu, Sang-Hwan;Oh, Soon-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • This paper presents a $4{\times}1$ beam-forming reader antenna system for a new type of RFID based train position detection technology. The required beamwidth of the reader antenna is analytically expressed for different train speeds. The proposed antenna system consists of four rectangular patch elements and two switching couplers which are designed, without any impedance matching networks, for two different antenna modes. The switching coupler is a rectangular quadrature coupler with Pin diodes connecting its center line and the ground plane. The beamwidth of the antenna when the diodes are off and on is $18^{\circ}$ and $39^{\circ}$, respectively. The proposed antenna system will be used for a real train test in the near future.

Fabrication technology of the focusing grating coupler using single-step electron beam lithography (Single-step 전자빔 묘화 장치를 이용한 Focusing Grating Coupler 제작 연구)

  • Kim, Tae-Youb;Kim, Yark-Yeon;Sohn, Yeung-Joon;Han, Gee-Pyeong;Paek, Mun-Cheol;Kim, Hae-Sung;Shin, Dong-Hoon;Rhee, Jin-Koo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.976-979
    • /
    • 2002
  • A focusing grating coupler (FGC) was not fabricated by the 'Continuous Path Control' writing strategy but by an electron-beam lithography system of more general exposure mode, which matches not only the address grid with the grating period but also an integer multiple of the address grid resolution (5 nm), To more simplify the fabrication, we are able to reduce a process step without large decrease of pattern quality by excluding a conducting material or layer such as metal (Al, Cr, Au), which are deposited on top or bottom of an e-beam resist to prevent charge build-up during e-beam exposure. A grating pitch period and an aperture feature size of the FGC designed and fabricated by e-beam lithography and reactive ion etching were ranged over 384.3 nm to 448.2 nm, and $0.5{\times}0.5mm^2$ area, respectively, This fabrication method presented will reduce processing time and improve the grating quality by means of a consideration of the address grid resolpution, grating direction, pitch size and shapes when exposing. Here our investigations concentrate on the design and efficient fabrication results of the FGC for coupling from slab waveguide to a spot in free space.

  • PDF

Vessel Remodeling after Intima-to-Intima Contact Anastomosis

  • Yeo, Hyeonjung;Kim, Hyodong;Son, Daegu;Hong, Changbae;Kwon, Sun Young
    • Archives of Plastic Surgery
    • /
    • v.44 no.2
    • /
    • pp.95-100
    • /
    • 2017
  • Background Intima-to-intima microanastomotic vascular remodeling was explored, utilizing a polylactide-caprolactone absorbable vein coupler model (PAVCM), which was designed to simulate a non-absorbable counterpart system with the sole exception of being absorbable. Methods Six New Zealand white rabbits were used. After transection of the jugular vein, 2 PAVCMs were placed, 1 at each transected end. The stumps were slipped through the PAVCMs, and the venous wall was everted $90^{\circ}$ to achieve intima-to-intima contact. Reanastomosis of the transected jugular vein was performed bilaterally in 3 rabbits. In the other 3 rabbits, the jugular vein (20 mm) harvested from one side was interpositionally grafted to the jugular vein on the opposite side to ease the anastomotic tension. Patency testing, ultrasonography, and histologic assessments were conducted postoperatively at weeks 2, 4, 12, 16, 22, and 26. Results All anastomotic sites were patent, without stenosis, occlusion, or dilatation. In the histologic sections, immature endothelial regeneration was observed at week 2, which was completed by week 4. Regeneration of the tunica media was noted at week 12. Between week 22 and week 26, the tunica media fully regenerated and the coupler dissipated entirely. Conclusions Despite the absence of a coupler to act as an anastomotic buttress, the structure and function of all the vessels appeared normal, even histologically. These outcomes are true milestones in the development of an absorbable vein coupler.

A Compact Ka-Band Doppler Radar Sensor for Remote Human Vital Signal Detection

  • Han, Janghoon;Kim, Jeong-Geun;Hong, Songcheol
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.4
    • /
    • pp.234-239
    • /
    • 2012
  • This paper presents a compact K-band Doppler radar sensor for human vital signal detection that uses a radar configuration with only single coupler. The proposed radar front-end configuration can reduce the chip size and the additional RF power loss. The radar front-end IC is composed of a Lange coupler, VCO, and single balanced mixer. The oscillation frequency of the VCO is from 27.3 to 27.8 GHz. The phase noise of the VCO is -91.2 dBc/Hz at a 1 MHz offset frequency, and the output power is -4.8 dBm. The conversion gain of the mixer is about 11 dB. The chip size is $0.89{\times}1.47mm^2$. The compact Ka-band Doppler radar system was developed in order to demonstrate remote human vital signal detection. The radar system consists of a Ka-band Doppler radar module with a $2{\times}2$ patch array antenna, baseband signal conditioning block, DAQ system, and signal processing program. The front-end module size is $2.5{\times}2.5cm^2$. The proposed radar sensor can properly capture a human heartbeat and respiration rate at the distance of 50 cm.

Development and Site Evaluation of the On-line Partial Discharge Measuring System on the 13 kV Class Stator Windings for Hydro Generator (13 kV급 수력발전기 고정자 권선용 On-line 부분방전 측정 시스템 개발 및 현장적용 평가)

  • Sun, Jong-Ho;Hwang, Don-Ha;Yun, Young-Ho;Shin, Byoung-Chol;Oh, Bong-Keun;Kang, Dong-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.189-198
    • /
    • 2006
  • In order to improve the reliability of stator windings for hydro generators, it is necessary to detect the defective point and life assessment of the high voltage windings. Especially the on-line partial discharge (PD) test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting generators, this method has been proven the major testing technology in high voltage rotating machines nowadays. The purpose of this paper is to describe the method of the on-line PD measurement on stator windings for hydro-generator with 13 [kV] class ceramic coupler (CC), on-line PD measuring system, terminal box, and index parameters. Also, the developed PD measuring system and 13 [kV] class CC were installed Daechung-dam generator #2. It was found that this installed sensor and system had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz.

Design of New Switching Structure for Time Division Duplex system (시분할 통신 시스템을 위한 새로운 구조의 스위칭회로 설계)

  • Kim, Kwi-Soo;Lim, Jong-Sik;Ahn, Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1076-1081
    • /
    • 2007
  • In this paper, we propose a new switch structure for time division duplex(TDD) system. The existing TDD structure utilizes a circulator fur isolation characteristic between ports. However, the circulator produces intermodulation distortion signals which are undesired signal because of its nonlinear properties. The proposed circuit is composed of a modified branch-line hybrid coupler which controls the signal flow while the isolated port is open-/short- terminated. In order to prove the validity of the presented structure, the switch circuit is fabricated and measured at 2.3GHz, the center frequency of Wibro service system.

  • PDF

Condition Monitoring of Link Driving System with Clearance (간극이 있는 링크구동계의 상태진단)

  • 최연선;민선환
    • Journal of KSNVE
    • /
    • v.11 no.1
    • /
    • pp.125-131
    • /
    • 2001
  • There is a clearance between the parts of a machine due to design tolerance, manufacturing error, wear, looseness, or misalignment. If the clearance is large, the vibration and noise of the machine is generally large. Therefore, the analysis on the nitration and noise of a machine can tell the clearance of the machine, which reveals the condition of the machine, i.e., the existence of faults and the safety of the machine. The investigation of this kind of research should be on the basis of experimental results. A link mechanism with a clearance at a joint between the coupler and locker is made for the investigation of the condition monitoring of a machine due to clearance. The vibration and sound are measured from the link driving system during the operation. The signals are clarified using line enhancement technique. The noise removed signals are used to develop the dynamic model of the system for a model based fault diagnosis. Also this study showed that the clarified signals can be used for the calculation of the joint forces between the coupler and rocker and for the correlation between the vibration and sound levels and the clearance sizes.

  • PDF

A Wideband Interferometric Wavelength Shift Demodulator of Fiber Bragg Grating Strain Sensor

  • Song, Min-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.64-68
    • /
    • 1999
  • The performance of a fiber Bragg grating strain sensor constructed with 3$\times$3 coupler is investigated. A 3$\times$3 coupler Mach-Zehnder (M/Z) interferometer is used as wavelength discriminator, interrogating strain-induced Bragg wavelength shifts. Two quadrature-phase-shifted intensities are synthesized from the as-coupled interferometer outputs, and digital arctangent demodulation and phase unwrapping algorithm are applied to extract the phase information proportional to strain. Due to the linear relation between the input strain and the output of quadrature signal processing, signal-fading problems eliminated. In the experiment, a fiber grating that was surface adhered on an aluminum beam was strained in different ways, and the photodetector signals were transferred and processed in a computer-controlled processing unit. A phase recovery fo 7.8$\pi$ pk-pk excursion, which corresponds to ~650$\mu$strain pk-pk of applied strain, was demonstrated. The sensor system was stable over the environmental intensi쇼 perturbations because of the self-referencing effect in the demodulation process.