• Title/Summary/Keyword: Coupled Tank Level

Search Result 17, Processing Time 0.019 seconds

An Injection-Locked Based Voltage Boost-up Rectifier for Wireless RF Power Harvesting Applications

  • Lee, Ji-Hoon;Jung, Won-Jae;Park, Jun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2441-2446
    • /
    • 2018
  • This paper presents a radio frequency-to-direct current (RF-to-DC) converter for special RF power harvesting application at 915 MHz. The major featured components of the proposed RF-to-DC converter is the combination of a cross-coupled rectifier and an active diode: first, the cross-coupled rectifier boosts the input voltage to desired level, and an active diode blocks the reverse current, respectively. A prototype was implemented using $0.18{\mu}m$ CMOS technology, and the performance was proven from the fact that the targeted RF harvesting system's full-operation with higher power efficiency; even if the system's input power gets lower (e.g., from nominal 0 to min. -12 dBm), the proposed RF-to-DC converter constantly provides 1.47 V, which is exactly the voltage level to drive follow up system components like DC-to-DC converter and so on. And, maximum power conversion efficiency is 82 % calculated from the 0 dBm input power, 2.3 mA load current.

Experimental Evaluation on the Vibration Control Effect of Tuned Liquid Damper with Embossment (벽면 요철형 동조액체댐퍼의 진동제어성능에 관한 실험적 평가)

  • Ju, Young Kyu;Kim, Dae Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.765-772
    • /
    • 2002
  • Many researchers have studied several vibration control devices such as TMD, TLD, and VED to reduce the acceleration level for tall buildings. Advantages of TLD (tuned liquid damper) include easy installation, low cost, and less maintenance. However, the dynamic characteristics of TLD must be verified by experiment and analysis due to the difficulties in evaluating the characteristics of water sloshing. In this study, free vibration and dynamic excitation experiments of structure with TLD were conducted to verify vibration control force of the proposed TLD for high-rise building. The parameters were mass ratio of water to structure, number of damping nets, and aspect ratio. From the test results, the responses of structure with water tank were observed to be smaller than those of structure alone. Furthermore, better damping effect could be achieved with larger mass ratio, more damping nets, and larger aspect ratio. However, in the case of water tank with no damping net, little damping effect was obtained.

Design and Implementaion of Web-based Remote Control Laboratory Using Water-level Control of Coupled Tank Apparatus (이중 탱크의 수위제어 기구를 이용한 Web기반 원격 제어 실험실의 설계 및 구현)

  • Hong, Sang-Eun;Park, Sung-Moo;Kim, Yong-Rae;Sung, Jung-Kun;Oh, Sang-Yeol
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11a
    • /
    • pp.325-328
    • /
    • 2010
  • 최근의 인터넷환경은 다양한 형태의 가상 및 원격 교육이 가능한 기반을 제공하고 있으며, 대학 및 교육기관에서는 이를 활용한 새로운 교육용 도구의 개발이 활발히 이루어지고 있다. 본 논문은 시공간의 제약 없이 실험을 수행할 수 있도록 하여 학습자들에게 반복 학습이 가능하도록 하였고, 유량제어를 실현 할 수 있는 비선형 시스템의 이중탱크 기구를 이용하여 다양한 제어이론을 실험할 수 있는 웹기반 실험실을 구현하였다. 전체 시스템은 SISO 시스템과 MIMO 시스템을 학습자가 선택하여 실험할 수 있도록 하였다. 유량제어 방식은 수동, PID, FUZZY 제어로 실험할 수 있도록 하여 학습자들에게 여러 가지 제어이론을 다양하게 학습할 수 있도록 구성하였으며, 릴레이 자기 동조법을 구현하여 학습자들로 하여금 PID변수를 확인할수 있도록 하였다. 또한 Web-Cam을 통하여 실험화면을 실시간으로 확인하면서 시뮬레이션을 동시에 실행하여 비교할 수 있도록 구현하였다.

  • PDF

Optimal design of passive containment cooling system for innovative PWR

  • Ha, Huiun;Lee, Sangwon;Kim, Hangon
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.941-952
    • /
    • 2017
  • Using the Generation of Thermal-Hydraulic Information for Containments (GOTHIC) code, thermal-hydraulic phenomena that occur inside the containment have been investigated, along with the preliminary design of the passive containment cooling system (PCCS) of an innovative pressurized water reactor (PWR). A GOTHIC containment model was constructed with reference to the design data of the Advanced Power Reactor 1400, and report related PCCS. The effects of the design parameters were evaluated for passive containment cooling tank (PCCT) geometry, PCCS heat exchanger (PCCX) location, and surface area. The analyzed results, obtained using the single PCCT, showed that repressurization and reheating phenomena had occurred. To resolve these problems, a coupled PCCT concept was suggested and was found to continually decrease the containment pressure and temperature without repressurization and reheating. If the installation level of the PCCX is higher than that of the PCCT, it may affect the PCCS performance. Additionally, it was confirmed that various means of increasing the external surface area of the PCCX, such as fins, could help improve the energy removal performance of the PCCS. To improve the PCCS design and investigate its performance, further studies are needed.

The Synchronous Control System Design of a Movable Weir using Coupling Structure (커플링구조를 이용한 가동위어의 동기제어시스템 설계)

  • Yang, Kyong-Uk;Byun, Jung-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.837-844
    • /
    • 2017
  • The weir to regulate water level in a tide generation tank is above and below carried by two electric cylinders which are mounted on right and left of weir itself. In this case, a movement difference between right and left cylinder causes unbalance of weir and friction between weir and guide. And then, the weir will not be sent to target point. In this study, a synchronous control system is developed to take accurate and quick equilibrium of the weir. The control system based on cross coupled structure consists of two I-PD controllers and a lead compensator. Each of the I-PD controllers is designed in order that the electric cylinder may exactly follow the reference signal without overshoot and input saturation. And the lead compensator is designed to achieve stable and accurate synchronization. Finally, the simulation result shows that the designed synchronous control system is effective for elimination of synchronous error.

A Fundamental Study on the Auditory Characteristics of Amberjack Seriola dumerili in the Coast of Jeju Island (제주 연안산 잿방어의 청각특성에 관한 기초적 연구)

  • 서익조;김성호;김병엽;이창헌;서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.269-275
    • /
    • 2003
  • In this paper, We examined auditory threshold and critical ratio of amberjack seriola dumerili, in the Jeju Island coastal waters, to find out hearing ability of the fish. The auditory threshold level, critical ratio and hearing index of amberjack were determinded by conditioning method using a sound coupled with electric shock in the condition of ambient noise or white noise in an experimental water tank. The audio-signals of pure tone and electric shock were from 80 HZ to 800 Hz and DC 7 V, respectively. Values for the critical ratios were calculated in terms of the masked thresholds using the noise projected to stable spectrum levels at all measurement frequencies of background noise. Masking noises were in the spectrum level range of 65 dB∼75 dB $(re 1{\mu}Pa\sqrt{Hz})$. The auditory thresholds of amberjack within the test the frequencies were most sensitive at 300HZ as 94.5 dB. The critical ratios of fishes ranged from 36.4 to 52.8 dB. The noise spectrum level that started masking was about 58∼72 dB within frequencies.

Numerical Analysis of Runup and Wave Force Acting on Coastal Revetment and Onshore Structure due to Tsunami (해안안벽과 육상구조물에서 지진해일파의 처오름 및 작용파력에 관한 수치해석)

  • Lee, Kwang Ho;Kim, Chang Hoon;Kim, Do Sam;Yeh, Harry;Hwang, Young Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3B
    • /
    • pp.289-301
    • /
    • 2009
  • In this work, wave run-up heights and resultant wave forces on a vertical revetment due to tsunami (solitary wave) are investigated numerically using a numerical wave tank model called CADMAS-SURF (CDIT, 2001. Research and Development of Numerical Wave Channel (CADMAS-SURF). CDIT library, No. 12, Japan.), which is based on a 2-D Navier-Stokes solver, coupled to a volume of fluid (VOF) method. The third order approximate solution (Fenton, 1972. A ninth-order solution for the solitary wave. J. of Fluid Mech., Vol. 53, No.2, pp.257-271) is used to generate solitary waves and implemented in original CADMAS-SURF code. Numerical results of the wave profiles and forces are in good agreements with available experimental data. Using the numerical results, the regression curves determined from the least-square analysis are proposed, which can be used to determine the maximum wave run-up height and force on a vertical revetment due to tsunami. In addition, the capability of CADMAS-SURF is demonstrated for tsunami wave forces acting on an onshore structure using various configuration computations including the variations of the crown heights of the vertical wall and the position of the onshore structure. Based on the numerical results such as water level, velocity field and wave force, the direct effects of tsunami on an onshore structure are discussed.