• Title/Summary/Keyword: Counter-type

Search Result 441, Processing Time 0.026 seconds

A Development of Counter Flow Type of Cooling System for Effective Panel Cooling (효과적인 패널 냉각을 위한 대향류형 냉각장치의 개발)

  • Lee, Joong-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.802-807
    • /
    • 2010
  • The high efficient and cooling system is very important to the control panels of electrical distributors, and Industrial automated system including computer. Also, it can be used widely in various industrial systems such as industrial robots, numerically controlled machining center, and so on. The cooling method which flowing gasses were forced to circulate by compulsion was adapted in this study. then development of counter flow type of cooling system for effective panel cooling. In the present study, fin assembly was developed for this cooling system. As results, the developed system has the improvements of cooling performances and radiant heat ratio. Its increasing of airflow mass is about 20%, and radiation rate of heating is twice or more as high as the conventional system.

Study on the Optimal CPS Implant for Improved ESD Protection Performance of PMOS Pass Structure Embedded N-type SCR Device with Partial P-Well Structure (PMOS 소자가 삽입된 부분웰 구조의 N형 SCR 소자에서 정전기 보호 성능 향상을 위한 최적의 CPS 이온주입에 대한 연구)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.1-5
    • /
    • 2015
  • The ESD(electrostatic discharge) protection performance of PPS(PMOS pass structure) embedded N-type silicon controlled rectifier(NSCR_PPS) device with different partial p-well(PPW) structure was discussed for high voltage I/O applications. A conventional NSCR_PPS standard device shows typical SCR-like characteristics with low on-resistance, low snapback holding voltage and low thermal breakdown voltage, which may cause latch-up problem during normal operation. However, our proposed NSCR_PPS devices with modified PPW_PGM(primary gate middle) and optimal CPS(counter pocket source) implant demonstrate the stable ESD protection performance with high latch-up immunity.

Application of the Detection of External Contamination on Radiation Workers for Bed Type Whole Body Counting Using Monte Carlo Method (몬테카를로 방법을 적용한 bed type 전신계측기의 방사선작업종사자 외부오염 검출 응용)

  • Kim, Jeong-In;Lee, Byoung-Il
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.242-245
    • /
    • 2013
  • Monte Carlo method was applied to discriminate the external contamination on radiation workers in nuclear power plants for internal dose assessment generally used with a bed type scanning detector whole body counter. Korean voxel model with internal contamination was used to estimate the detection patterns of whole body scanning. Also, the BOMAB model with various external contamination was assumed to compare with detection of radionuclides inside the human body. From the comparison of detection efficiency between front and back side up, external contamination was easily distinguished.

Evaluation of Effects on Tritium Measurement According to HTO Type Sample Preparation Conditions (HTO 형태 시료 조제 조건에 따른 삼중수소 계측에 미치는 영향 평가)

  • An, Eun-Mi;Kim, Jung-Hoon;Lee, Hong-Yeon;Han, Sang-Jun;Kim, Bo-Gil
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.381-387
    • /
    • 2021
  • In this study, for the measurement of 3H(tritium) radioactivity concentration, a study was conducted on whether the type of cocktail and the material of the vial had an effect on the measurement before liquid scintillation counter measurement on HTO-type samples that had undergone physical and chemical pretreatment. As a result of the study, the efficiency according to the type of cocktail was higher in Ultima Gold LLT than Ultima Flo-AP cocktail with polyethylene (1.49%), glass (5.10%), and teflon (6.58%), respectively. Regarding the effect according to the type of vial, the efficiency and SQP(E) of both Ultima Gold LLT and Ultima Flo-AP showed the highest values in the order of teflon, polyethylene, and glass.

Performance Research of Counter-rotating Tidal Stream Power Unit

  • Wei, Xuesong;Huang, Bin;Liu, Pin;Kanemoto, Toshiaki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.2
    • /
    • pp.129-136
    • /
    • 2016
  • An experimental investigation was carried out to improve the performance of a counter-rotating type horizontal-axis tidal stream power unit. Front and rear blades were designed separately based on modified blade element momentum (BEM) theory, and their performances at different conditions of blade tip speed ratio were measured in a wind tunnel. Three different groups of blades were designed successively, and the results showed that Group3 possessed the highest power coefficient of 0.44 and was the most satisfactory model. This experiment shows that properly increasing diameter and reducing chord length will benefit the performance of the blade.

APPLICATION OF WHOLE BODY COUNTER TO NEUTRON DOSE ASSESSMENT IN CRITICALITY ACCIDENTS

  • Kurihara, O.;Tsujimura, N.;Takasaki, K.;Momose, T.;Maruo, Y.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.249-253
    • /
    • 2001
  • Neutron dose assessment in criticality accidents using Whole Body Counter (WBC) was proved to be an effective method as rapid neutron dose estimation at the JCO criticality accident in Tokai-mura. The 1.36MeV gamma-ray of $^{24}Na$ in a body can be detected easily by a germanium detector. The Minimum Detectable Activity (MDA) of $^{24}Na$ is approximately 50Bq for 10miniute measurement by the germanium-type whole body counter at JNC Tokai Works. Neutron energy spectra at the typical shielding conditions in criticality accidents were calculated and the conversion factor, whole body activity-to-organ mass weighted neutron absorbed dose, corresponding to each condition were determined. The conversion factor for uncollied fission spectrum is 7.7 $[(Bq^{24}Na/g^{23}Na)/mGy]$.

  • PDF

Development of the Lightning Surge Voltage and Current Counters (뇌써지 전압/전류 카운터의 개발)

  • Kil, K.S.;Chang, S.H.;Lee, B.H.;Lee, Y.K.;Lee, B.K.;Ohk, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1882-1884
    • /
    • 1996
  • This paper deals with the lightning surge counter. In order to install the effective surge protective devices, it is important to find the parameters of incident surges. For the purpose of observing the occurrence frequency as a parameter of the amplitude of surge, two type surge counters were designed and fabricated. One is operated by surge currents, and the other is operated by surge voltages. The former consists of current sensor, metal oxide varister (MOV), rectifier, capacitor and electromagnetic counter. The latter consists of rectifier, voltage divider, comparator, photo coupler and counter circuit, and is useful for detecting the surge voltages.

  • PDF

The Effect of Oxide Layer Formed on TiN Coated Ball and Steel Disk on Friction Characteristics in Various Sliding Conditions (미끄럼조건에 따라 TiN 코팅볼과 스틸디스크에 형성되는 산화막이 마찰특성에 미치는 영향)

  • 조정우;이영제
    • Tribology and Lubricants
    • /
    • v.17 no.6
    • /
    • pp.459-466
    • /
    • 2001
  • In this study, the effects of oxide layer formed on the contact parts of TiN coated ball and steel disk on friction characteristics in various sliding conditions were investigated. AISI52100 steel ball was used for the substrate of coated ball specimens, which were prepared by depositing TiN coating with 1(m in coating thickness. AISI1045 steel was used for the disk type counter-body. To investigate the effect of oxide layer on the contact parts of two materials, the tests were performed both in air for forming oxide layer on the contact parts and in nitrogen environment to avoid oxidation. From the test results, the frictional characteristic between the two materials was predominated by iron oxide layer that formed on wear tract of counter-body and this layer caused friction transition and high friction. And the adhesive wear occurred from steel disk to TiN coated ball caused the formation of oxide layer on counter parts between the two materials.

A Study on the Dynamic Characteristics of Counter Balance Valve for High Load (고부하용 카운터 밸란스 밸브의 동적 특성에 관한 연구)

  • Sung, Won-Jun;Chung, Kwang-Sik;Lee, Seung-Hyun
    • Tribology and Lubricants
    • /
    • v.18 no.1
    • /
    • pp.68-74
    • /
    • 2002
  • In this study, the dynamic characteristics of the spool type counter balance valve are studied. The nonlinear governing differential eguations are derived. Routh-Hurwitz criterion is used to characterize the linearized eguations. Static and dynamic experiments are carried out for the determination of parameters that are necessary for the analysis and the stability of the system.

Spatiotemporal behavior of excited Xe atoms density in Counter discharged type AC-PDP

  • Hong, Young-June;Oh, Phil-Yong;Jeong, Se-Hoon;Hong, Jong-Hwa;Kim, Jung-Hyun;Gyu, Yong;Cho, Seok-Ho;Hong, Sung-Hee;Hong, Byoung-Hee;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.574-577
    • /
    • 2007
  • We have measured the excited Xe atoms density in the $1s_5$ metastable states by laser absorption spectroscopy in counter discharged type AC-PDP. This experiment has shown the characteristic of the excited Xe atoms density which is relation to the visible light efficiency of PDP. The density of counter discharged AC-PDP have measured to be $9.47\;{\times}\;10^{13}\;cm{-3}$. The result has been shown to higher value than $1.45\;{\times}\;10^{13}\;cm^{-3}$ of conventional AC-PDP.

  • PDF