• Title/Summary/Keyword: Counter-ion

Search Result 166, Processing Time 0.027 seconds

Acustic Study on the Kinetics for the Dissociation-Recombination Reaction between Micelle and Counter-ion in Dodecyl Pyridinium Bromide Solution (Dodecyl Pyridinium Bromide 水溶液中의 Micelle과 Counter-Ion 間의 解離-再結合反應에 對한 超音波에 依한 反應速度論的 硏究)

  • Lee Kun Moo
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.2
    • /
    • pp.73-79
    • /
    • 1973
  • The ultrasonic absorption of Dodecyl pyridinium bromide (D.P.B.) in aqueous solution has been measured at $20^{\circ}C$ over a range of frequencies between 0.1 mc and 90 mc and a range of concentrations from 5 to 100 mM. The excess absorption was observed only in the solutions the concentration of which was higher than the critical micellar concentration (c.m.c.) both in the presence and absence of salt. The excess absorption of sound and the relaxation frequencies obtained from the absorption curves show a discontinuity with the variation of the concentration of D.P.B. in the neighborhood of 60 mM. Other properties such as viscosity, conductivity and velocity of sound also exhibit such a change near the same concentration. It is concluded that a change in the properties of the micelles of D.P.B. occurs in the neighborhood of this concentration. The mechanism of the observed ultrasonic excess absorption in attributed to the reaction $M_2{\rightleftarrow}M_1+2Br^-$where$M_2$ and$M_1$are two types of micelles. The rate constants of forward and backward reactions are found to be $6.9 {\times} 10^5 sec^{-1)$and $6.7{\times}10^{10}sec^{-1}mole{-2}$ respectively. Some kinetic characteristics including free energy, enthalpy, entropy and activation energy were calculated.

  • PDF

Study on the Micellization of CPC/Brij 35 Mixed Surfactant Systems in Water (순수 물에서 CPC/Brij 35 혼합계면활성제의 미셀화에 대한 연구)

  • Gil, Han-Nae;Lee, Byung-Hwan
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.2
    • /
    • pp.118-124
    • /
    • 2009
  • The values of critical micelle concentration (CMC) and counter ion binding constants (B) in a micellar state of CPC (1-hexadecylpyridinium chloride) with Brij 35 (polyoxyethylene(23) lauryl ether) in water were determined as a function of ${\alpha}_1$ (the overall mole fraction of CPC) by the use of electric conductivity method. Various thermodynamic parameters ($X_i,\;{\gamma}_i,\;C_i,\;a_{i}^{M},\;\beta,\;and\;{\Delta}H_{mix}$) were calculated and analyzed by means of the equations derived from the non-ideal mixed micellar model. And thermodynamic parameters (${\Delta}{G^o}_m,\;{\Delta}{H^o}_m,\;and\;{\Delta}{S^o}_m$) for the micellization of CPC/Brij 35 mixtures were also calculated from the temperature dependence of the CMC values. The values of ${\Delta}{G^o}_m$ are all negative, but the values of ${\Delta}{S^o}_m$ and ${\Delta}{H^o}_m$ are positive or negative, depending on the measured temperature and ${\alpha}_1$.

Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System (중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발)

  • Ko, Tae-Young;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.408-411
    • /
    • 2017
  • In this paper, we propose an integrated control system that measures neutrons, gamma ray, and x-ray. The proposed system is able to monitor and control the data measured and analyzed on the remote or network, and can monitor and control the status of each part of the system remotely without remote control. The proposed system consists of a gamma ray/x-ray sensor part, a neutron sensor part, a main control embedded system part, a dedicated display device and GUI part, and a remote UI part. The gamma ray/x-ray sensor part measures gamma ray and x-ray of low level by using NaI(Tl) scintillation detector. The neutron sensor part measures neutrons using Proportional Counter Detector(low-level neutron) and Ion Chamber Type Detector(high-level neutron). The main control embedded system part detects radiation, samples it in seconds, and converts it into radiation dose for accumulated pulse and current values. The dedicated display device and the GUI part output the radiation measurement result and the converted radiation amount and radiation amount measurement value and provide the user with the control condition setting and the calibration function for the detection part. The remote UI unit collects and stores the measured values and transmits them to the remote monitoring system. In order to evaluate the performance of the proposed system, the measurement uncertainty of the neutron detector was measured to less than ${\pm}8.2%$ and the gamma ray and x-ray detector had the uncertainty of less than 7.5%. It was confirmed that the normal operation was not less than ${\pm}15$ percent of the international standard.

Interaction of the Post-transition Metal Ions and New Macrocycles in Solution

  • Jung, Oh-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.6
    • /
    • pp.687-691
    • /
    • 1993
  • Complexation of $Cd^{2+},\;Pb^{2+}\;and\;Hg^{2+}$ ions with four cryptands were studied by potentiometry and solution calorimetry in various weight percent methanol-aqueous solvent at 25${\circ}$C under $CO_2$free nitrogen atmosphere. The stabilities of the complexes were dependent on the cavity size of macrocycles. The $Hg^{2+}$ ion stability constants are higher than those of $Cd^{2+}\;and\;Pb^{2+}$ ion. All the cryptands formed complexes having 1 : 1 (metal to ligand) mole-ratio except for $Hg^{2+}-L_1$ (cryptand 1,2b: 3,5-benzo-9,14,17-trioxa-1,7-diazabicyclo-(8,5,5) heptadecane) and $Cd^{2+}-L_2$ (cryptand 2,2b: 3,5-benzo-10,13,18,21-tetraoxa-1,7-diazabicyclo (8,5,5) eicosane) complexes. $Hg^{2+}-L_1$ complex was a sandwitch type, and the $Cd^{2+}-L_2$ complex showed two stepwise reactions. Thermodynamic parameters of the $Cd^{2+}-L_2$ complex were $6.08(log\;K_1)$, -7.28 Kcal/mol $({\Delta}H_1)$, and $4.78\;(log\;K_2)$, -4.62 Kcal/mol $({\Delta}H_2)$, respectively, for 1 : 1 and 2: 1 mole-ratio. The sequences of the selectivity were increased in the order of $Hg^{2+}\;>Pb^{2+}\;>Cd^{2+}$ ion for $L_3\;and\;L_4$ macrocycles, and the $L_2$-macrocycle has a selectivity for $Cd^{2+}$ ion relative to $Zn^{2+},\;Ni^{2+},\;Pb^{2+}\;and\;Hg^{2+}$ ions. Thus, it is expected that the $L_2$ can be used as carrier for seperation of the post transition metals by macrocycles-mediated liquid membrane because $L_2$ is not soluble in water, and the difference of stability constants of the metal complexes with $L_2$ are large as compared with the other transition metal complexes. The $^1H\;and\;^{13}C-NMR studies indicated that the nitrogen atoms of cryptands have greater affinity to the post transition metal ions than the oxygen atoms, and that the planarities of the macrocycles were lost by complexation with the metal ions because of the perturbation of ring current of benzene molecule attached to macrocycles and counter-anions.

Improving Power Conversion Efficiency and Long-term Stability Using a Multifunctional Network Polymer Membrane Electrolyte; A Novel Quasi-solid State Dye-sensitized Solar Cell

  • Gang, Gyeong-Ho;Gwon, Yeong-Su;Song, In-Yeong;Park, Seong-Hae;Park, Tae-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.484.2-484.2
    • /
    • 2014
  • There are many efforts to improving the power conversion efficiencies (PCEs) of dye-sensitized solar cells (DSCs). Although DSCs have a low production cost, their low PCE and low thermal stability have limited commercial applications. This study describes the preparation of a novel multifunctional polymer gel electrolyte in which a cross-linking polymerization reaction is used to encapsulate $TiO_2$ nanoparticles toward improving the power conversion efficiency and long-term stability of a quasi-solid state DSC. A series of liquid junction dye-sensitized solar cells (DSCs) was fabricated based on polymer membrane encapsulated dye-sensitized $TiO_2$ nanoparticles, prepared using a surface-induced cross-linking polymerization reaction, to investigate the dependence of the solar cell performance on the encapsulating membrane layer thickness. The ion conductivity decreased as the membrane thickness increased; however, the long term-stability of the devices improved with increasing membrane thickness. Nanoparticles encapsulated in a thick membrane (ca. 37 nm), obtained using a 90 min polymerization time, exhibited excellent pore filling among $TiO_2$ particles. This nanoparticle layer was used to fabricate a thin-layered, quasi-solid state DSC. The thick membrane prevented short-circuit paths from forming between the counter and the $TiO_2$ electrode, thereby reducing the minimum necessary electrode separation distance. The quasi-solid state DSC yielded a high power conversion efficiency (7.6/8.1%) and excellent stability during heating at $65^{\circ}C$ over 30 days. These performance characteristics were superior to those obtained from a conventional DSC (7.5/3.5%) prepared using a $TiO_2$ active layer with the same thickness. The reduced electrode separation distance shortened the charge transport pathways, which compensated for the reduced ion conductivity in the polymer gel electrolyte. Excellent pore filling on the $TiO_2$ particles minimized the exposure of the dye to the liquid and reduced dye detachment.

  • PDF

Hard TiN Coating by Magnetron-ICP P $I^3$D

  • Nikiforov, S.A.;Kim, G.H.;Rim, G.H.;Urm, K.W.;Lee, S.H.
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.5
    • /
    • pp.414-420
    • /
    • 2001
  • A 30-kV plasma immersion ion implantation setup (P $I^3$) has been equipped with a self-developed 6'-magnetron to perform hard coatings with enhanced adhesion by P $I^3$D(P $I^3$ assisted deposition) process. Using ICP source with immersed Ti antenna and reactive magnetron sputtering of Ti target in $N_2$/Ar ambient gas mixture, the TiN films were prepared on Si substrates at different pulse bias and ion-to-atom arrival ratio ( $J_{i}$ $J_{Me}$ ). Prior to TiN film formation the nitrogen implantation was performed followed by deposition of Ti buffer layer under A $r^{+}$ irradiation. Films grown at $J_{i}$ $J_{Me}$ =0.003 and $V_{pulse}$=-20kV showed columnar grain morphology and (200) preferred orientation while those prepared at $J_{i}$ $J_{Me}$ =0.08 and $V_{pulse}$=-5 kV had dense and eqiaxed structure with (111) and (220) main peaks. X-ray diffraction patterns revealed some amount of $Ti_{x}$ $N_{y}$ in the films. The maximum microhardness of $H_{v}$ =35 GN/ $M^2$ was at the pulse bias of -5 kV. The P $I^3$D technique was applied to enhance wear properties of commercial tools of HSS (SKH51) and WC-Co alloy (P30). The specimens were 25-kV PII nitrogen implanted to the dose 4.10$^{17}$ c $m^{-2}$ and then coated with 4-$\mu\textrm{m}$ TiN film on $Ti_{x}$ $N_{y}$ buffer layer. Wear resistance was compared by measuring weight loss under sliding test (6-mm $Al_2$ $O_3$ counter ball, 500-gf applied load). After 30000 cycles at 500 rpm the untreated P30 specimen lost 3.10$^{-4}$ g, and HSS specimens lost 9.10$^{-4}$ g after 40000 cycles while quite zero losses were demonstrated by TiN coated specimens.s.

  • PDF

A New Design of Blood Cell Counter using DSP chip and Optimal Discrimination Method (DSP 칩과 최적분별법을 이용한 새로운 혈구입자 계수기 설계)

  • Kim, G.H.;Kim, J.W.;Kim, K.S.;Hong, W.H.;Kim, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.05
    • /
    • pp.89-93
    • /
    • 1991
  • The purpose of this reserch is to design the blood cell counting instrument which can measure the number of RBC(Red Blood Cell) and WBC(White Blood Cell) including many other blood component. The proposed method uses the electrical impedence method and the new discrimination method wi th DSP chip and software algorithm. The system consist of control unit, blood cell discrimination unit, hemoglobin spectrometer, post detect ion processor unit, and IBM-PC interface unit. In this paper, the discrimination system has been implemented using digital signal processor, which result in the reduction of system hardware and cost. The system is helpful in providing necessary clinical test for screen test and quality control of hematology.

  • PDF

Kinetic Study using Ultrasonic Technique on the Dissociation-Recombination Reaction between Micelle and Counter-ion in Dodecyl Pyridinium Chloride Solution (超音波를 利用한 Dodecyl Pyridinium Chloride 水溶液中의 미셀과 반대이온 사이의 解離-再結合反應의 反應速度論的 硏究)

  • Kun Moo Lee
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.3
    • /
    • pp.193-197
    • /
    • 1976
  • The ultrasonic absorption has been measured in aqueous solution of dodecyl pyridinium chloride (DPC) at $20^{\circ}C$ over the frequency range of 0.1${\sim}$90 Mc.The excess absorption was observed only in solutions in which the concentration was higher than the critical micellar concentration(cmc). The mechanism for this feature was attributed to the reaction $M_2\;{\rightleftharpoons}\;M_1\;+\;1.2Cl^-$ Where $M_2$ and $M_1$ and M1 are two types of micelle. The rate constants of the forward and the reverse reactions were $6.6{\times}10^5 sec^{-1}\;and\;2.7{\times}10^11sec^{-1}mol^{-1.2}$respectively. Some kinetic charateristics including the free energy, enthalpy and entropy were calculated.

  • PDF

Optimal Design of ESD Protection Device with different Channel Blocking Ion Implantation in the NSCR_PPS Device (NSCR_PPS 소자에서 채널차단 이온주입 변화에 따른 최적의 정전기보호소자 설계)

  • Seo, Yong-Jin;Yang, Jun-Won
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.4
    • /
    • pp.21-26
    • /
    • 2016
  • The ESD(electrostatic discharge) protection performance of PPS(PMOS pass structure) embedded N-type silicon controlled rectifier(NSCR_PPS) device with different implant of channel blocking region was discussed for high voltage I/O applications. A conventional NSCR standard device shows low on-resistance, low snapback holding voltage and low thermal breakdown voltage, which may cause latch-up problem during normal operation. However, our proposed NSCR_PPS devices with modified channel blocking structure demonstrate the improved ESD protection performance as a function of channel implant variation. Therefore, the channel blocking implant was a important parameter. Since the modified device with CPS_PDr+HNF structure satisfied the design window, we confirmed the applicable possibility as a ESD protection device for high voltage operating microchips.

Cloning of Rod Opsin Genes Isolated from Olive Flounder Paralichthys olivaceus, Japanese Eel Anguilla japonica, and Common Carp Cyprinus carpio

  • Kim, Sung-Wan;Kim, Jong-Myoung
    • Fisheries and Aquatic Sciences
    • /
    • v.12 no.4
    • /
    • pp.265-275
    • /
    • 2009
  • G Protein-coupled receptors (GPCRs) mediating wide ranges of physiological responses is one of the most attractive targets for drug development. Rhodopsin, a dim-light photoreceptor, has been extensively used as a model system for structural and functional study of GPCRs. Fish have rhodopsin finely-tuned to their habitats where the intensity and the wavelength of lights are changed depending on its water-depth. To study the detailed molecular characteristics of GPCR architecture and to understand the fishery light-sensing system, genes encoding rod opsins were isolated from fishes living under different photic environments. Full-length rod opsin genes were obtained by combination of PCR amplification and DNA walking strategy of genomic DNA isolated from olive flounder, P. olivaceus, Japanese eel, A. japonica, and Common carp C. carpio. Deduced amino acid sequences showed a typical feature of rod opsins including the sites for Schiffs base formation (Lys296) and its counter ion (Glu113), disulfide formation (Cys110 and Cys187), and palmitoylation (Cys322 and Cys323) although Cys322 is replaced by Phe in Japanese eel. Comparison of opsins by amino acid sequence alignment indicated the closest similarity between P. olivaceus and H. hippoglossus (94%), A. japonica and A. anguilla (98%), and C. carpio and C. auratus (95%), respectively.