• 제목/요약/키워드: Counter Rotating

검색결과 173건 처리시간 0.022초

엇회전식 축류홴의 공력 특성에 관한 실험적 연구 (Experimental Study on the Aerodynamic Characteristics of a Counter-Rotating Axial Fan)

  • 최진용;조이상;조진수;원유필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.441-446
    • /
    • 2000
  • The experiments of the Aerodynamic characteristics of a counter-rotating axial fan were carried out. The performance tests of a single and a counter-rotating axial fan were carried out based on the Korean Standard Testing Methods for Turbo-fans and Blowers(KS B 6311). The performances of single and counter-rotating axial fans were obtained and compared with each other. The flow fields of a counter-rotating axial fan at the peak efficiency point were measured using a five-hole probe. As a result, compared with the performance of a single-rotating axial fan, that of a counter-rotating axial fan was superior. And it is confirmed that most of the swirl flow generated by the front rotor was eliminated by the rear rotor.

  • PDF

엇회전식 축류홴의 공력 특성에 관한 전산 해석 및 실험 (Numerical and Experimental Analyses of the Aerodynamic Characteristics of a Counter Rotating Axial Fan)

  • 조진수;원유필;이문철
    • 대한기계학회논문집B
    • /
    • 제24권3호
    • /
    • pp.325-337
    • /
    • 2000
  • A study was done on the numerical and experimental analyses of the aerodynamic characteristics of a counter rotating axial fan. The numerical analysis uses the frequency domain panel method developed for the aerodynamic analysis of interacting rotating systems, which is based on the unsteady lifting surface panel method. Each stage of interaction involves the solution of an isolated rotor, the interaction being done through the Fourier transform of the induced velocity field. Numerical results showed good agreements with other experimental data for single and counter rotating propeller systems. And they were compared with the experimental results of the counter rotating axial fan studied in the present paper. The performance test was carried out based on the Korean Standard (KS B 6311). It was focused on the relative efficiency increase of a counter rotating system for a single rotating one, and effects of the axial distance between the front and rear rotors on overall fan performances were investigated. As a result, it was shown that the counter rotating axial fan has the efficiency 14% higher than the single rotating one at peak efficiency points.

와류격자기법을 이용한 Counter-Rotating 풍력 발전기의 성능 및 후류 해석 연구 (Prediction for the Performance and Wakes of a Counter-Rotating Wind Turbine Using the Vortex Lattice Method)

  • 이승민;손은국;이수갑
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.40.2-40.2
    • /
    • 2011
  • A Counter-rotating wind turbine is one of the new concepts that are proposed to increase the performance of a wind turbine. It has two rotors rotating in the same axis, and it is known that its power coefficient can reach to 0.64 in the ideal case. While the BEMT is widely used to analyze the aerodynamic performance of wind turbines, the analysis of the counter-rotating wind turbine by using it is limited due to the aerodynamic interaction between the two rotors. In this study, the vortex lattice method is used to consider the effect of the front rotor on the rear rotor of the counter-rotating wind turbine and calculate the aerodynamic performance of it. The power and thrust sharing in the two rotors of the counter-rotating wind turbine are predicted and the total power and thrust are compared with that of a single rotor. Moreover, the wake convection and expansion rate is also compared with that of a single rotor.

  • PDF

고성능 엇회전식 축류팬의 공력특성에 대한 전산해석 (Numerical analyses on the Aerodynamic Characteristics of a Counter-rotating Axial Flow Fan)

  • 조이상;조진수
    • 융복합기술연구소 논문집
    • /
    • 제5권1호
    • /
    • pp.37-40
    • /
    • 2015
  • Numerical analyses on the aerodynamic characteristics of a counter rotating axial flow fan is carried out using the frequency domain panel method. Front rotor and rear rotor blades of a counter rotating axial fan are designed by using the simplified meridional flow analysis method with the radial equilibrium equation and the free vortex design condition, according to design requirements. Performance characteristics of a counter rotating axial flow fan are estimated for the variation of design parameters such as the hub to tip ratio, the taper ratio and the solidity. Pressure losses were higher at leading edge and hub region of rotor blades. Characteristic curve of the counter rotating fan was overpredicted without consideration of viscous effect.

10kW급 상반전 조류터빈의 설계와 성능에 관한 연구 (Design and Performance Evaluation of a 10kW Scale Counter-Rotating Tidal Turbine)

  • 황안둥;양창조
    • 한국유체기계학회 논문집
    • /
    • 제17권1호
    • /
    • pp.47-53
    • /
    • 2014
  • This paper aims to present the design and performance evaluation of a counter-rotating tidal turbine using CFD and to compare its performance with single rotor. The device scale is 10kW and the rotating part consists of two rotors which rotate in opposite direction. Compared with conventional single rotor, the counter-rotating system shows higher power efficiency at high stream velocity but lower efficiency at low stream velocity. The added counter-rotated rotor together helps improve the energy absorption capacity but has influence on the upstream rotor that reduces its performance. In terms of power capture, the designed counter-rotating tidal turbine is more advantageous in high speed tidal condition.

엇회전식 축류 펜의 공력 특성에 관한 실험적 연구 (Experimental Study on the Aerodynamic Characteristics of a Counter-Rotating Axial Flow Fan)

  • 최진용;조이상;조진수;원유필
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.201-210
    • /
    • 2002
  • Experiments were done for performance and flow characteristics of a counter-rotating axial flow fan. Performance curves of a counter-rotating axial flow fan were obtained and compared by varying the blade pitch angles. The fan characteristic curves were obtained following the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fan flow characteristics were measured using a five-hole probe and a slanted hot-wire. The velocity profiles between the hub and tip of the fans were measured and analyzed at the peak efficiency point. The peak efficiency of the counter-rotating axial flow fan was improved about 15% respectively, compared with the single rotating axial fan. The single rotating axial flow fan showed relatively law efficiency due to the swirl velocities behind rotor exit which produced pressure losses. The counter-rotating axial flow fan showed that the swirl velocity generated by the front rotor was eliminated by the rear rotor and the associated dynamic pressure is recovered in the from of the static pressure rise.

엇회전식 축류팬의 비정상 유동특성에 관한 실험적 연구 (Experimental Study on the Unsteady Flow Characteristics of the Counter-Rotating Axial Flow Fan)

  • 조이상;최현민;강정식;조진수
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.305-310
    • /
    • 2007
  • 엇회전식 축류팬의 복잡한 유동특성을 이해하고 설계, 공력 해석 및 소음 특성 예측에 활용될 수 있는 3차원 비정상 유동장을 측정하였다. 엇회전식 축류팬의 3차원 비정상 유동장은 작동 영역인 설계점에서 $45^{\circ}$ 경사 열선을 이용하여 전단 동익의 전방, 전단 동익과 후단 동익 사이 그리고 후단 동익의 후방의 수직 유로 단면에서 측정되었다. 엇회전식 축류팬의 전단 동익과 후단 동익에 의해 발생되는 후류, 팁 와류 및 팁 누설 유동의 비정상 특성을 속도 벡터와 속도 윤곽을 통해 나타내었다.

  • PDF

이축 스크루 압출기내 유동의 수치 해석과 혼합 성능 분석 (Numerical Study of Internal Flow in Twin Screw Extruder and Its Mixing Performance Analysis)

  • 김낙수;김홍범;이재욱
    • 대한기계학회논문집A
    • /
    • 제30권1호
    • /
    • pp.32-41
    • /
    • 2006
  • We analyzed the non-Newtonian and non-isothermal flow in the melt conveying zone in co-rotating and counter-rotating screw extruder system with the commercial code, STAR-CD, and compared the mixing performance with respect to screw speed and rotating direction. The viscosity of fluid was described by power-law model. The dynamics of mixing was studied numerically by tracking the motion of particles in a twin screw extruder system. The extent of mixing was characterized in terms of the residence time distribution and average strain. The results showed that high screw speed decreases the residence time but increases the shear rate. Therefore higher screw speed increases the strain and has better mixing performance. Counter-rotating screw extruder system and co-rotating screw extruder has the similar shear rate with the same screw speed in spite of different rotating direction. However, the counter-rotating screw has good mixing performance, which is resulted from longer residence time than that of co-rotating screw extruder.

주로터 제자리 비행 시 익단 와류와 Counter-rotating Vortex의 수치적 관찰 (A Numerical Investigation of the Main Rotor Tip-vortex and Counter-rotating Vortex during Hovering Flight)

  • 전종혁;정인재;이덕주
    • 한국항공우주학회지
    • /
    • 제41권10호
    • /
    • pp.761-769
    • /
    • 2013
  • 헬리콥터의 후류가 공기력에 미치는 영향은 매우 크다. 하지만 후류의 형상은 매우 복잡하며 예상하기 힘들다. 본 연구에서는 수치적인 방법을 통하여 후류를 자세히 관찰할 것이다. 후류에서의 와류를 자세히 관찰하기 위한 수치적 방법으로는 와류격자법과 자유후류법을 사용하였다. 본 연구에서 제자리 비행에서의 후류 형상을 관찰하였다. 적절한 추력계수를 갖는 제자리 비행에서는 익단 와류 뿐 아니라 블레이드의 안쪽에서 발생하는 counter-rotating vortex도 관찰할 수 있다. 이러한 와류들이 아래로 내려가면서 익단 와류와 counter-rotating vortex가 서로 가까워지며 서로에게 영향을 끼치게 된다. 이에 따라 와류들은 자체적인 불안정성으로 인해 형상이 변한다.

10kW급 상반전 풍력터빈 로터의 설계와 성능 평가에 관한 연구 (Design and Performance Evaluation of a 10kW Scale Counter-Rotating Wind Turbine Rotor)

  • 황안둥;양창조
    • 해양환경안전학회지
    • /
    • 제20권1호
    • /
    • pp.104-112
    • /
    • 2014
  • 상반전 풍력터빈은 설계와 성능 관점에서 최근 각광을 받기 시작하고 있다. 본 논문은 NREL S822, S823을 이용하여 설계 및 모델링한 상반전 풍력터빈에 대해 연구를 수행하였다. 본 논문은 수치해석 기법을 통하여 단일 풍력터빈과 상반전 풍력터빈을 각각 설계하고, 그 성능을 다양한 조건에서 비교하고자 하였다. 그 결과 상반전 풍력터빈은 단일 풍력 터빈에 비해 TSR 3~5 영역에서 보다 높은 성능계수를 나타냈으며, 그 보다 더 높은 TSR 영역에서는 낮은 성능계수를 나타내었다. 이것은 로터 상 하류의 간섭의 간섭 때문이며, 또한 본 연구에서는 낮은 영역의 TSR에서 운전되는 상반전 풍력터빈의 유효성을 함께 보였다.