• Title/Summary/Keyword: Count rate

Search Result 871, Processing Time 0.028 seconds

Design of a Readout Circuit of Pulse Rate and Pulse Waveform for a U-Health System Using a Dual-Mode ADC (이중 모드 ADC를 이용한 U-Health 시스템용 맥박수와 맥박파형 검출 회로 설계)

  • Shin, Young-San;Wee, Jae-Kyung;Song, Inchae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.68-73
    • /
    • 2013
  • In this paper, we proposed a readout circuit of pulse waveform and rate for a U-health system to monitor health condition. For long-time operation without replacing or charging a battery, either pulse waveform or pulse rate is selected as the output data of the proposed readout circuit according to health condition of a user. The proposed readout circuit consists of a simple digital logic discriminator and a dual-mode ADC which operates in the ADC mode or in the count mode. Firstly, the readout circuit counts pulse rate for 4 seconds in the count mode using the dual-mode ADC. Health condition is examined after the counted pulse rate is accumulated for 1 minute in the discriminator. If the pulse rate is out of the preset normal range, the dual-mode ADC operates in the ADC mode where pulse waveform is converted into 10-bit digital data with the sampling frequency of 1 kHz. These data are stored in a buffer and transmitted by 620 kbps to an external monitor through a RF transmitter. The data transmission period of the RF transmitter depends on the operation mode. It is generally 1 minute in the normal situation or 1 ms in the emergency situation. The proposed readout circuit was designed with $0.11{\mu}m$ process technology. The chip area is $460{\times}800{\mu}m^2$. According to measurement, the power consumption is $161.8{\mu}W$ in the count mode and $507.3{\mu}W$ in the ADC mode with the operating voltage of 1 V.

ON THE BACKGROUND-SUBTRACTED INTENSITY (백그라운드 제거후 신호의 세기에 대하여)

  • Seon, Kwang-Il
    • Publications of The Korean Astronomical Society
    • /
    • v.20 no.1 s.24
    • /
    • pp.109-116
    • /
    • 2005
  • When we measure a source signal in the presence of a background rate that has been independently measured, the usual approach is to obtain an estimate of the background rate by observing an empty part of the sky, and an estimate of the source signal plus background rate by observing the region where a source signal is expected. The source signal rate is then estimated by subtracting the background rate from the source signal plus background rate. However, when the rates or their observation times are small, this procedure can lead to negative estimates of the source signal rate, even when it should produce a positive value. By applying the Bayesian approach, we solve the problem and prove that the most probable value of source signal rate is zero when the observed total count is smaller than the expected background counts. It is also shown that the results from the conventional method is consistent with the most probable value obtained from the Bayesian approach when the source signal is large or the observation time is long enough.

Container System Actively Maintaining High CO2 Concentration for Improved Sensory Quality of Kimchi

  • Lee, Hye Lim;An, Duck Soon;Jung, Yong Bae;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.22 no.3
    • /
    • pp.79-84
    • /
    • 2016
  • A kimchi container actively controlling $CO_2$ concentration by timely flushing of $CO_2$ gas was structured and tested in its capability and effectiveness because high $CO_2$ concentration enhances the sensory flavor of the product. The inlet and outlet valves of $CO_2$ gas were programmed to open and close allowing synchronous vent/$CO_2$ flush according to the requirements of its dissolution in the contained kimchi. During the chilled storage, the headspace of container could be maintained at desired high $CO_2$ concentration providing the preferred kimchi in sensory quality compared to control of the conventional container. However, there was no significant difference between the high $CO_2$ container and control (container simply closed with air) in kimchi quality attributes of pH, titratable acidity, total viable bacterial count, Lactobacillus sp. count and Leuconostoc sp. count. The flow rate and time interval of $CO_2$ flushing need to be adjusted considering the kimchi amount, headspace volume and ripening time. The designed system has potential to be applied in refrigerator appliances in homes and food service industry.

A single blind randomised placebo controlled clinical trial of a classical Ayurvedic formulation Ashokarista in the treatment of menorrhagia and dysmenorrhoea

  • Akhtar, Yasmeen;Alamgir, Mahiuddin;Khan, Mahmud Tareq Hassan;Hannan, JMA.;Choudhuri, M Shahabuddin Kabir
    • Advances in Traditional Medicine
    • /
    • v.7 no.4
    • /
    • pp.372-378
    • /
    • 2007
  • A well known Ayurvedic formulation Ashokarista, used for menstrual disorders has been studied in a single blind randomised placebo controlled clinical trial for the treatment of menorrhagia and dysmenorrhoea. Dysmenorrhoea and menorrhagia patients who were taking Ashokarista (20 ml twice daily) for 10 menstrual cycles had an increase in haemoglobin level. Menorrhagia treated group has shown to reduce the erythrocyte sedimentation rate level that has been increased in the menorrhagia control group. The platelet count, total count and differential count were observed unchanged in the study. The Ashokarista did not affect the SGPT and SGOT level, which signify its lack of toxicity in hepatic function. The treated menorrhagic patients showed an increase in serum albumin content and decrease in blood clotting time, whereas the serum protein content was observed unchanged. There was a significant increase in both serum cholesterol and triglyceride level, which usually associated with the use of oral contraceptives. No major side effects were observed by the clinicians during the study.

Design of a Sentiment Analysis System to Prevent School Violence and Student's Suicide (학교폭력과 자살사고를 예방하기 위한 감성분석 시스템의 설계)

  • Kim, YoungTaek
    • The Journal of Korean Association of Computer Education
    • /
    • v.17 no.6
    • /
    • pp.115-122
    • /
    • 2014
  • One of the problems with current youth generations is increasing rate of violence and suicide in their school lives, and this study aims at the design of a sentiment analysis system to prevent suicide by uising big data process. The main issues of the design are economical implementation, easy and fast processing for the users, so, the open source Hadoop system with MapReduce algorithm is used on the HDFS(Hadoop Distributed File System) for the experimentation. This study uses word count method to do the sentiment analysis with informal data on some sns communications concerning a kinds of violent words, in terms of text mining to avoid some expensive and complex statistical analysis methods.

  • PDF

Evaluation of Physical Characteristics of Discovery ST scanner Using NEMA NU2-2001 Standard (NEMA NU2-2001을 이용한 PET-CT 스캐너의 물리적 특성평가)

  • Lee, Byeong-Il
    • Journal of Integrative Natural Science
    • /
    • v.1 no.2
    • /
    • pp.79-83
    • /
    • 2008
  • As a new standard for performance measurement, NEMA NU2-2001 was presented recently. In this study, I investigated the spatial resolution, sensitivity, scatter fraction, and noise equivalent count ratio (NECR) in order to know the information of physical characteristics and system performance of GE discovery ST using this new standard. Bismuth germinate crystals ($6{\times}6$ array, $6.3mm{\times}6.3mm{\times}30mm$) were used in discovery ST (energy window:375-650 keV, coincidence window:11.7 nsec). To measure the sensitivity, five aluminum sleeves (Data Spectrum Corp., Chapel Hill, NC., USA, thickness:1.25 mm)-NEMA sensitivity phantom- filled with F-18 solution were used. Successive measurements in 2D and 3D acquisition mode were made with a line source at the center of transaxial field of view and 10 cm off from the center until the count was over 500,000. Spatial resolution was estimated using a point source (F-18, 0.1 mCi) at different locations in the FOV. Scatter fraction and NECR was tested using a NEMA scatter phantom. Dynamic data were acquired for 7 half-lives using F-18 solution. And true to background ratio was averaged at last three frames when the random rate was as small as ignorable for the calculation of scatter fraction. We anticipate this overall evaluated results could be used for the quality assurance and optimized image acquisition for clinical research.

  • PDF

A practical subcritical rod worth measurement technique based on the improved neutron source multiplication method

  • Jiahe Bai;Chenghui Wan;Ser Gi Hong;Hongchun Wu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1398-1406
    • /
    • 2024
  • The control rod worth is a key safety parameter required to be measured in commercial pressurized water reactors (PWRs). Conventionally, the control rod worth is measured after reaching the critical state, which occupies the considerable time in the zero-power physics test. In this study, an efficient control-rod worth measurement technique has been proposed based on the improved neutron-source multiplication method, which can be implemented with the source-range detector count rates in the subcritical states. Moreover, the noise reduction technique has been adopted to smooth the large fluctuation existing in the original signals. In order to verify the engineering performance of the proposed measurement technique, the measured source-range detector count rates during the rod withdrawal process before reaching critical state in a CNP1000 reactor have been employed. It demonstrated that almost all estimated results of control rod worth satisfy the engineering acceptance criteria, except one control rod with the relative difference over 10 %, which indicates the capability of the proposed method in estimating control rod worth.

Pregnancy Rate by Intrauterine Insemination (IUI) with Controlled Ovarian Hyperstimulation (COH) (자궁강내 인공수정에 의한 임신율)

  • Hong, Jeong-Eui;Lee, Ji-Sam
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.25 no.2
    • /
    • pp.217-231
    • /
    • 1998
  • The effectiveness of intrauterine insemination (IUI) combined with controlled ovanan hyperstimulation (COH) in the treatment of infertility with various etiologies was compared in a total of 152 cycles. Patients received a maximum of three IUI cycles for the treatment. Severe male ($<2\times10^6$ motile sperm) or age factor (> 39 y) patients were excluded in this study. Pregnancy was classified as clinical if a gestational sac was seen on ultrasound. The overall clinical pregnancy rate was 7.9% per cycle (12/152) and 9.7% per patient (12/124). The pregnancy rates were 0% in unstimulated natural (0/18), 7.5% in CC (3/40), 8.2% in CC+hMG (4/49), 5.9% in GnRH-a ultrashort (1/17), 5.9% in GnRH-a long (1/17) and 27.3% in dual suppression cycles (3/11), respectively. The pregnancy rate was higher in dual suppression cycle than other stimulated cycles, but this was not significant. The multiple pregnancy rates were 25.0% (2 twins and 1 triplet). No patient developed ovarian hyperstimulation. Abortion rates were 66.7% in CC (2/3) and 100% in ultrashort cycles (1/1). The livebirth rate was 5.9% per cycle (9/152) and 7.3% per patient (9/124). There were no differences in age, duration of infertility, follicle size, total ampules of gonadotropins and days of stimulation between pregnant and non-pregnant groups. However, significant(P<0.05) differences were observed in the level of estradiol $(E_2)$ on the day of hCG injection ($3,266.6{\pm}214.2$ vs $2,202.7{\pm}139.4$ pg/ml) and total motile sperm count ($212.1{\pm}63.4$ vs $105.1{\pm}9.9\times10^6$) between pregnant group and non-pregnant group. These results suggest that IUI combined with successful ovarian stimulation tends to improve the chance of pregnancy as compared to IUI without COH and a total motile sperm count may be considered predictive of the success for pregnancy.

  • PDF

A Adaptive Garbage Collection Policy for Flash-Memory Storage System in Embedded Systems (실시간 시스템에서의 플래시 메모리 저장 장치를 위한 적응적 가비지 컬렉션 정책)

  • Park, Song-Hwa;Lee, Jung-Hoon;Lee, Won-Oh;Kim, Hee-Earn
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.12 no.3
    • /
    • pp.121-130
    • /
    • 2017
  • NAND flash memory has advantages of non-volatility, little power consumption and fast access time. However, it suffers from inability that does not provide to update-in-place and the erase cycle is limited. Moreover, the unit of read/write operation is a page and the unit of erase operation is a block. Therefore, erase operation is slower than other operations. The AGC, the proposed garbage collection policy focuses on not only garbage collection time reduction for real-time guarantee but also wear-leveling for a flash memory lifetime. In order to achieve above goals, we define three garbage collection operating modes: Fast Mode, Smart Mode, and Wear-leveling Mode. The proposed policy decides the garbage collection mode depending on system CPU usage rate. Fast Mode selects the dirtiest block as victim block to minimize the erase operation time. However, Smart Mode selects the victim block by reflecting the invalid page number and block erase count to minimizing the erase operation time and deviation of block erase count. Wear-leveling Mode operates similar to Smart Mode and it makes groups and relocates the pages which has the similar update time. We implemented the proposed policy and measured the performance compare with the existing policies. Simulation results show that the proposed policy performs better than Cost-benefit policy with the 55% reduction in the operation time. Also, it performs better than Greedy policy with the 87% reduction in the deviation of erase count. Most of all, the proposed policy works adaptively according to the CPU usage rate, and guarantees the real-time performance of the system.