• Title/Summary/Keyword: Count rate

Search Result 862, Processing Time 0.039 seconds

Effect of Tedding Time and Frequency on the Feed Value and Drying Rate of Rye(Secale cereale L.) Hay

  • Li, Yu Wei;Zhao, Guo Qiang;Liu, Chang;Wei, Sheng Nan;Kim, Hak Jin;Kim, Jong Geun
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.39 no.3
    • /
    • pp.171-177
    • /
    • 2019
  • Hay-making is one of the most common way for forage preservation in livestock industry. The quality and production of hay could be affected by various factors. This experiment was conducted to investigate the effect of tedding time and frequency on drying rate and feed value of forage rye (Secale cereale L.) hay. Rye was harvested on heading stage using mower conditioner. Hay was tedded at each set hour(09:00, 13:00 and 17:00) and sampled at each set hour to determine dry matter (DM) content. After two months' preservation, CP (crude protein), ADF (acid detergent fiber), NDF (neutral detergent fiber), IVDMD (in vitro dry matter digestibility), TDN (total digestible nutrient), RFV (relative feed value), DM loss, visual scores and total fungi count were determined for estimation of hay quality. Tedding was necessary for both speeding up drying rate and improving forage quality. Tedding at 17:00 showed lower NDF content (p<0.05), and also higher RFV value was found compared with tedding at 9:00 and 13:00 (p<0.05). On the other hand, it was observed that more DM losses would be found when tedding later (p<0.05). Tedding in 1~3 times per day were lower in ADF and NDF content (p<0.05), increased CP, TDN and RFV (p<0.05), got less DM loss (p<0.05), and contained less fungi during conservation compared with no tedding (p<0.05). On the other hand, tedding too frequent caused more DM loss (p<0.05). In conclusion, for shorter drying process and higher quality of forage rye hay, tedding at 13:00~17:00 for 1~2 times per day was recommended in this study.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Statistical Analysis of 1,000 Cases of Kawasaki Disease Patients Diagnosed at a Single Institute (단일 기관에서 진단받은 가와사끼병 환아 1,000례의 통계학적 분석)

  • Hwang, Dae Hwan;Sin, Kyoung Mi;Choi, Kyong Min;Choi, Jae Young;Sul, Jun Hee;Kim, Dong Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.4
    • /
    • pp.416-424
    • /
    • 2005
  • Purpose : To find the risk factors associated with coronory artery lesions, non-responsiveness to intravenous immunoglobulin(IVIG) treatment, and recurrences in Kawasaki disease patients. Methods : We retrospectively analyzed 1,000 Kawasaki disease patients who were admitted to Yonsei University Medical Center from September 1990 to December 2003. We compared between responder and non-responder groups to IVIG treatment as well as between relapsed and non-relapsed groups, and as to the relapsed group, we also compared variables between patients in their first and second attack states. Finally, factors associated with longer-fever duration from disease onset were evaluated. Results : Longer fever durations before and after IVIG treatment, male sex, lower Hgb and Hct level, higher WBC count and segmented WBC proportion, and higher CRP and Harada's score were related with coronary artery lesions. Non-responsiveness was related to higher WBC count, segmented WBC proportion, CRP, SGPT, Harada's score, and pyuria. Moderate-to-severe coronary artery dilatations and recurrences were more commonly seen among the non-responder group. No significant predictive factors for recurrence were found. In the relapsed group, lower WBC count, CRP, and shorter fever duration from disease onset were observed in their second attack state. Fever duration from disease onset showed positive correlation with WBC count, CRP, and Harada's score and negative correlation with Hgb levels. Conclusion : Higher WBC count, CRP, and higher Harada's score were related to both higher incidences of coronary artery lesions and non-responsiveness to IVIG treatment, and these factors were also related with longer fever duration. Non-responders to IVIG treatment showed higher recurrence rate and more moderate-to-severe coronary artery dilatations than responders.

Comparison of the Measurement of the Injection Rate of Radioactive Drugs Using 99mTc in Nuclear Medicine (핵의학과에서 99mTc를 이용한 방사성의약품의 투여율 측정 비교)

  • Son, Sang-Joon;Park, Jeong-Kyu;Jung, Dong-Kyung;Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.97-103
    • /
    • 2020
  • This study was conducted by SPECT test at the Department of Nuclear Medicine at Daegu P Hospital from June 1 to October 31, 2019. A 3-way injection material was mounted among inpatients, and a syringe that was administered with radiopharmaceuticals using a 99mTc labeled compound was secured. We tried to find a way to calculate the dose rate of each radiopharmaceutical and increase the dose rate. As a result of measuring the radioactivity of radio-pharmaceuticals using 99mTc, the average dose rate of 60 syringes of all 6 radiopharmaceuticals was 93.26±7.34%, and the average dose rate of 99mTc-DMSA was 77.72%, 15.54% lower than the total. As a way to increase the dosing rate, the average dose rate diluted twice with the remaining amount of syringe after administration using normal saline increased to 95.37±6.99%, and the average dose rate diluted three times increased to 96.32±6.86%. The corresponding sample t-test to compare the pre- and post-dose rates at 1 dilution and 2 and 3 dilutions. As a result of the dilution and 2 dilutions, the probability of significance was 0.013, which was significantly higher than the dilution(p<0.05). The probability of significance for dilution 1 and dilution 3 was 0.016, which was significantly higher than in one dilution(p<0.05). The sum of the average dose rate using the experimental 3-way line was the highest with 98.85±1.42% of 99mTc, 99mTc-ECD 98.82±1.26%, 99mTc-Mebrofenin 98.82 ± 1.16%, 99mTc-HDP 98.74 ± 1.91%, 99mTc -MIBI was 98.69 ± 1.48%, and 99mTc-DMSA was the lowest with 86.47 ± 4.74%. When the number of dilutions was 5 times using 0.5 cc of normal saline and when the number of dilutions was 5 times using 1 cc of normal saline, when the number of dilutions was 5 times using 0.5 cc of normal saline and 1 cc of nomal saline When the number of dilutions was 5 times and the syringe volume was 0.5 cc, there was a statistically significant difference (p<0.05). There was a statistically significant difference when the number of dilutions was 5 times using 1 cc of nomal saline and the number of dilutions was 5 times using 1 cc of normal saline, and the syringe volume was 0.5 cc (p<0.05).

INHIBITORY EFFECT OF LACTOCOCCUS LACTIS 1370 ON THE FORMATION OF DENTAL PLAQUE IN CHILDREN (소아에서 Lactococcus lactis 1370에 의한 치태형성 억제 효과)

  • Lee, Lan-Young;Lee, Chang-Seop;Lee, Kwang-Hee;Oh, Jong-Suk;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.583-592
    • /
    • 2001
  • This study was undertaken to evaluate the clinical effect of inhibiting plaque formation of Lactococcus lactis 1370, a acid producing bacterium residing in the mouth. 30 children were asked to use 10ml of control mouth-wash and mouthwash containing Lactococcus lactis 1370. The plaque index and plaque area rate at 24h and 48h after the use of the mouthwashes were measured. And the number of Lactococcus lactis 1370 was counted at 1h, 3h, and 6h in the mouth. The results are as follow. 1. The mean plaque index at 24h after the use of the control mouthwash and the mouthwash containing Lactococcus lactis 1370 were 2.43 and 2.06, respectively. The inhibiting rate of plaque formation was 15% (P<0.05). 2. The mean plaque index at 48h after the use of the control mouthwash and the mouthwash containing Lactococcus lactis 1370 were 2.95 and 2.17, respectively. The inhibiting rate of plaque formation was 26%, showing more decrease than at 24h(P<0.05). 3. The mean plaque area rate at 24h after the use of the control mouthwash and the mouthwash containing Lactococcus lactis 1370 were 21.2% and 15.6%, respectively. The inhibiting rate of plaque formation was 26% (P<0.05). 4. The mean plaque area rate at 48h after the use of the control mouthwash and the mouthwash containing Lactococcus lactis 1370 were 33.0% and 17.8%, respectively. The inhibiting rate of plaque formation was 46% (P<0.05). 5. The number of Lactococcus lactis 1370 in the mouth decreased significantly from mouthwashing to 3h, but increased slightly between 3h and 6h. As seen with the above results, we think that using the mouth wash with Lactococcus lactis 1370 would prevent the formation of plaque in the mouth and can be an effective method to prevent dental caries and periodontal disease.

  • PDF

Studies on Antioxidative Effect and Lactic Acid Bacteria Growth of Persimmon Leaf Extracts (감잎 추출물의 유산균 생육 및 항산화 효과에 관한 연구)

  • Woo Jun-Young;Paek Nam-Soo;Kim Young-Man
    • The Korean Journal of Food And Nutrition
    • /
    • v.18 no.1
    • /
    • pp.28-38
    • /
    • 2005
  • This study was investigated the growth effect of persimmon leaf extracts on various Lactic acid bacteria, the effect as freeze-dry cryoprotectan, by the changes of vitamin C content, electron donating ability, total cell count and SOD-like activity. The total cell count of L. acidophilus MG501, L. brevis MG19, L. bulgaricus MG515, L. lactis MG530 and L. casei MG311 in the absence of persimmon leaf extracts(10%) at 37℃ after 48hr were 3.2×10/sup 9/cfu/mL, 2.9×10/sup 9/cfu/mL, 1.1×10/sup 9/cfu/mL, 1.6×10/sup 9/cfu/mL and 3×10/sup 9/cfu/mL, respectively, and pH and total acidity of those were 3.82∼3.88, and 1.697∼1.842. On the other hand, the total cell count of L. acidophilus MG501, L. brevis MG19, L. bulgaricus MG515, L. lactis MG530 and L. casei MG311 in the presence of persimmon leaf extracts at 37℃ after 48hr were 4.4×10/sup 9/cfu/mL, 4.3×10/sup 9/cfu/mL, 2×10/sup 9/cfu/mL, 3.3×10/sup 9/cfu/mL, and 3.4×10/sup 9/cfu/mL, respectively, and pH and total acidity of those were 3.74∼3.82 and 1.528∼1.805. The total cell counter of lactic acid bacteria in the presence of persimmon leaf extracts(10%) at 37℃ after 48hr higher than those in the absence of persimmon leaf extracts. In freeze-dry chryoprotectan, the survival rate of L. acidphilus MG501 decreased about 30%. In case of L. brevis MG19 and L. bulgaricus MG515, the survival rate decreased about 10%. However, the survival rate of L. lactis MG530 increased about 10% and L. casei MG311 showed the almost same effect. The changes of vitamin C content were the highest in L. lactis MG530(190.26mg/mL) and the lowest in L. acidophilus MG501(56.05 mg/mL). The electron donating ability indicated to L. acidophilus MG501, L. brevis MG19, L. bulgaricus MG515, L. lactis MG530 and L. casei MG311 added by 10% persimmon leaf extracts, respectively. when 10% persimmon leaf extracts were added L. brevis MG19, the electron donating ability is the highest of all lactic acid bacteria. The SOD-like activity of L. acidophilus MG501, L. brevis MG19, L. bulgaricus MG515, L. lactis MG530 and L. casei MG311 showed lower than that of control.

Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography (GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가)

  • Jeong, Ha-Kyu;Kim, Hee-Joung;Son, Hye-Kyung;Bong, Jung-Kyun;Jung, Hai-Jo;Jeon, Tae-Joo;Kim, Jae-Sam;Lee, Jong-Doo;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.100-112
    • /
    • 2001
  • Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.

  • PDF

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF

Removal Effects of Microorganism and Pesticide Residues on Chinese Cabbages by Electrolyzed Water Washing (전기분해수 세척에 따른 배추의 미생물 및 잔류농약 제거효과)

  • Sung, Jung-Min;Park, Kee-Jai;Lim, Jeong-Ho;Jeong, Jin-Woong
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.628-633
    • /
    • 2012
  • This study investigated the washing efficiency of electrolyzed water for the removal of microorganisms and pesticide residues from Chinese cabbage. Initial total bacteria and coliform counts were 6.64 and 3.56 log cfu/g respectively. After washing, total bacteria count of tap water (TW) were 5.97 log cfu/g and low alkaline electrolyzed water (LAlEW) and strong acidic electrolyzed water (SAcEW) were 1.63-4.67 log cfu/g. Especially SAcEW-100 was found to the most effective method of washing the cabbages. After washing, the coliform count was dramatically reduced. The removal rate of pesticide residues by NaClO treatment (36.93-50.13%) was greater than that of TW treatment (32.28-38.46%). The removal rate of LAlEW-100 and SAcEW-100 was 63.79 and 78.30% respectively, and was higher than those of TW and NaClO treatments. The vitamin C content of the Chinese cabbages after all treatments did not differ significantly. Consequentially, the electrolyzed water was found to be effective to remove bacteria and pesticide residues from Chinese cabbage without affecting quality.

Effects of Daidzein on Body Weight Gain, Serum IGF-I Level and Cellular Immune Function in Intact Male Piglets

  • Wang, Genlin;Zhang, Xiangying;Han, Zhaoyu;Liu, Zhaobin;Liu, Weirong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.7
    • /
    • pp.1066-1070
    • /
    • 2002
  • 10 male piglets at 5-6 weeks old with similar body weight (BW) were randomly assigned into the experimental (EXP) and control (CON) groups. The animals in EXP received intro-muscular injection with daidzein (DA) at the dose of 0.5 mg DA per kg start BW on day 1. The same procedures were repeated once every 3 days for eight times. The animals in CON received the injection only with same volume of control peanut oil. The animals were weighted on day 14 and 28 and the blood samples were obtained at different stages of the treatment for determining IGF-I levels and blood parameters. At the end of the experiment, the thymus and spleen from all the animals were surgically taken out and weighted. The results showed that BW and average daily gain (ADG) were not significantly different between the groups in term of the whole period, but ADG between days 14-28 was higher in EXP than in CON (p<0.05). On days 18, 21 and 25, IGF-I levels in EXP group were 20.53% (p<0.05), 15.92% (p>0.05) and 23.46% (p<0.05), respectively, higher than those in CON. The weights of thymus and spleen, the ratios of their weights to BW and red blood count (RBC) did not significantly differ between the groups at all stages. White blood count (WBC) in EXP steadily increased from day 22, reached its apex on day 24, which was higher than in CON (p<0.05) and its own levels on day 20 and 22 (p<0.01 or p<0.05), and remained higher on the later time (p=0.058). The results of percentage of T-Lymphocytes also demonstrated similar trend to WBC, but TLymphocyte transformation rate (%) appeared no significant change between the groups. In conclusion, Daidzein could stimulate male piglet growth and elevate serum IGF-I levels at certain stages of the treatment. It could also increase WBC and T-Lymphocyte rates, but had no significant impacts on RBC and T-Lymphocyte transformation rate.