Study of the CatcherTM Couch's Usefulness (토모치료기 CatcherTM Couch의 유용성에 대한 고찰)

  • Um, Ki Cheon;Lee, Chung Hwan;Jeon, Soo Dong;Song, Heung Kwon;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.65-74
    • /
    • 2019
  • Purpose: Recently, A Catcher was added to prevent sagging in Radixact® X9. In this study, We quantitatively compared general couch of Tomo-HDA® with catcher couch of Radixact® X9 using the human phantom and evaluated usefulness of catcher. Materials and methods: We used rando phantom for phantom study and set the each iso-center of head and neck region and Pelvis region for region parameter. Furthermore, We used hand made low melting point alloys for weight parameter. MVCT(Mega Voltage Computed Tomography) images were acquired for vertical error and rotation(pitch) error measurement increasing weight(A: 15kg, A+B: 30kg, A+B+C: 45kg). We selected 120 patients who has been treated using Tomotherpy machine for patient study. 60 patients has been treated in Tomo-HDA® and the other 60 patients treated in Radixact® X9. In the patient study methods, vertical error and rotation(pitch) error was measured for mean value calculation using MVCT images acquired on first day of radiation therapy. Result: Result of phantom study, Vertical error and rotation(pitch) error was increased proportionally increased as the weight increases in general couch of Tomo-HDA®. each maximum value was 7.52mm, 0.38° in head and neck region and 11.94mm, 0.92° in pelvis region. However, We could confirm that there was stable error range(0.02~0.1mm, 0~0.04°) in Catcher couch of Radixact®. Result of patient study, The head and neck region was measured 4.79mm 0.33° lower, and the pelvis region was measured 7.66mm, 0.22° lower in Catcher couch of Radixact® X9. Conclusion: In this study, Vertical error and rotation(pitch) error was proportionally increased as the weight increases in general couch of Tomo-HDA®. Especially, The pelvis region error was more increased than the head and neck region error. However, Vertical error and rotation(pitch) error was regularly generated regardless of weight or regions in CatcherTM couch of Radixact® X9 that this study's purpose. In conclusion, CatcherTM couch of Radixact® X9 can minimize mechanical error that couch sagging. Furthermore, The pelvis region is more efficiency than head and neck region. In radiation therapy using Tomotherapy machine, it is regarded that may contribute to minimizing unadjusted pitch error due to characters of Tomotherapy.

Evaluation on the Usefulness of 6DoF Couch in V-MAT on Patients with Long length of Target (표적의 길이가 긴 환자의 용적회전변조 방사선치료 시 6DoF Couch의 유용성 평가)

  • Choi, Young Se;Park, Hyo Kuk;Kim, Se Young;Kim, Joo Ho;Lee, Sang Kyoo;Yoon, Jong Won;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.53-64
    • /
    • 2017
  • Purpose: To evaluate the usefulness of the $HexaPOD^{TM}$ evo RT system(6DoF couch) and the tendency of dose difference according to size of rotational direction error for volumetric rotational modulated radiotherapy(V-MAT) in patients with long target lengths. Therefore, it is suggested to recommend the need for rotational error correction. Materials and Methods: Ten patients with Esophagus cancer or Breast cancer including SCL treated with HexaPOD 6DoF(Six-Degree of Freedom) couch were included in this study. 6DoF couch was used to measure the difference in dose according to the rotation error in the directions of Rx(pitch), Ry(roll), and Rz(yaw). Each rotation error was applied. Positioning variation on x, y and z axis was verified and random variations were made by 6DoF couch with positioning variation. Modified DQA is conducted and point dose and gamma value are analyzed and compared. In addition, after applying the rotation error every $1^{\circ}$ to treatment plans of each target with a diameter of 3 cm, 5, 10, 15, and 20 cm respectively, gamma passing rate is being monitored by its aspect of change according to types and sizes of the target length and rotation error. Results: Mean error of the point dose and Gamma passing rate when the position variation was applied were $2.50{\pm}1.11%$ and $84.1{\pm}7.39%$ in the Rx direction, $2.36{\pm}1.16%$, and $81.0{\pm}8.49%$ in the Ry, $2.35{\pm}1.10%$ and $84.4{\pm}6.99%$ in the Rz direction, respectively. As a result of analysis on gamma passing rate according to types and sizes of the target length and rotation error, the gamma passing rate tended to decrease with increasing rotation error in the Rx and Rz directions except Ry direction. In particular, the lowest gamma passing rate (74.2 %) was in the case of $2.5^{\circ}$ rotation error in Rz direction of the target of 10 cm. Conclusion: The correction of the rotational error is needed for volumetric modulated radiotherapy of the treatment area with a long target length, and the use of 6DoF couch will improve the reproducibility of the patient position and the quality of the treatment.

  • PDF

Evaluation of VMAT Dose Accuracy According to Couch Rotation in Stereotactic Radiation Surgery of Metastatic Brain Cancer (전 이성 뇌 암의 정위 방사선수술에서 Couch 회전에 따른 VMAT의 선량 정확성 평가)

  • Na, Gwui Geum;Park, Byoung Suk;Cha, Woo Jung;Park, Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.117-125
    • /
    • 2021
  • Purpose: To purpose of this study is to find the correlation of the Set-up error according to the couch rotation and suggest additional margin setting for the GTV. Target and Method: Each scenario treatment plan was created by making the frequency of non-coplanar beams different among all beams. The set-up error value was measured by using the Exact System and the dose accuracy was evaluated by creating a re-treatment plan. Results: When the couch was rotated by 30°, 45°, 60°, and 90°, the mean of the X-axis values was measured to be 0.29 mm, 0.26 mm, 0.51 mm, and 0.08 mm, respectively. The mean of the Y-axis values was measured to be 0.75 mm, 0.5mm, 0.35 mm, and 0.29 mm, respectively. The mean of the Z-axis values was measured to be 0.5 mm, 0.28 mm, 0.22 mm, and 0.1 mm, respectively. There were dose reductions of 0.1%, 3.1%, 1.9% in D99 for 1-NC VMAT, 2-NC VMAT, and 3-NC VMAT, respectively. Conclusion: When treating with 50% or more of non-coplanar beams among total beams, image verification is required. And it is considered to make the treatment plan by adding a 1.5 mm margin to the GTV.

Evaluation of the Usefulness of the Self-developed Kw-infrared Reflective Marker in Non-coplanar Treatment (비동일면 치료 시 자체 제작한 Kw-infrared Reflective Marker의 유용성 평가)

  • Kwon, Dong-Yeol;Ahn, Jong-Ho;Park, Young-Hwan;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: In radiotherapy that takes into account respiration using a RPM (Real time Position Management, Varian, USA) system, which can treat in consideration of the movement of tumor, infrared reflective markers supplied by manufacturers cannot obtain respiratory signal if the couch rotates at a certain angle or larger. In order to solve this problem, the author developed the 3D infrared reflective marker named 'Kw-marker' that can obtain respiratory signal at any angle, and evaluate its usefulness. Materials and Methods: In order to measure the stability of respiratory signal, we put the infrared reflective marker on the 3D moving phantom that can reproduce respiratory movement and acquired respiratory signal for 3 minutes under each of 3 conditions (A: $couch\;0^{\circ}$, a manufacturer's infrared reflective marker B: $couch\;0^{\circ}$, Kw-marker C: $couch\;90^{\circ}$, Kw-marker). By analyzing the respiratory signal using a breath analysis program (Labview Ver. 7.0), we obtained the peak value, valley value, standard deviation, variation value, and amplitude value. In order to examine the rotation error and moving range of the target, we placed a B.B phantom on the 3D moving phantom, and obtained images at a couch angle of $0^{\circ}$ and $90^{\circ}$ using OBI, and then acquired the X, Y and Z values (mm) of the ball bearing at the center of the B.B phantom. Results: According to the results of analyzing the respiratory signal, the standard deviation at the peak value was A: 0.002, B: 0.002 and C: 0.003, and the stability of respiration for amplitude was A: 0.15%, B: 0.14% and C:0.13%, showing that we could get respiratory signal stably by using the Kw-marker. When the couch rotated $couch\;90^{\circ}$, the mean rotation error of the ball bearing, namely, the target was X: -1.25 mm, Y: -0.45 mm and Z: +0.1 mm, which were within 1.3 mm on the average in all directions, and the difference in the moving range of the target was within 0.3 mm. Conclusion: When we obtained respiratory signal using the Kw-marker in non-coplanar treatment where the couch rotated, we could acquire respiratory signal stably and the Kw-marker was effective enough to substitute for the manufacturer's infrared reflective marker. When the rotation error and moving range of the target were measured, there was little difference, indicating that the displacement of the reflector movement in couch rotation is the cause of change in the scale and amplitude of respiratory signal. If the converted value of amplitude height according to couch angle is studied further and applied, it may be possible to perform non-coplanar phase-based gating treatment.

  • PDF

Evaluation of Accuracy About 2D vs 3D Real-Time Position Management System Based on Couch Rotation when non-Coplanar Respiratory Gated Radiation Therapy (비동일평면 호흡동조방사선치료 시 테이블 회전에 따른 2D vs 3D Real-Time Position Management 시스템의 정확성 평가)

  • Kwon, Kyung-Tae;Kim, Jung-Soo;Sim, Hyun-Sun;Min, Jung-Whan;Son, Soon-Yong;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.601-606
    • /
    • 2016
  • Because of non-coplanar therapy with couch rotation in respiratory gated radiation therapy, the recognition of marker movement due to the change in the distance between the infrared camera and the marker due to the rotation of the couch is called RPM (Real-time The purpose of this paper is to evaluate the accuracy of motion reflections (baseline changes) of 2D gating configuration (two dot marker block) and 3D gating configuration (six dot marker block). The motion was measured by varying the couch angle in the clockwise and counterclockwise directions by $10^{\circ}$ in the 2D gating configuration. In the 3D gating configuration, the couch angle was changed by $10^{\circ}$ in the clockwise direction and compared with the baseline at the reference $0^{\circ}$. The reference amplitude was 1.173 to 1.165, the couch angle at $20^{\circ}$ was 1.132, and the couch angle at $1.0^{\circ}$ was 1.083. At $350^{\circ}$ counterclockwise, the reference amplitude was 1.168 to 1.157, the couch angle at $340^{\circ}$ was 1.124, and the couch angle at $330^{\circ}$ was 1.079. In this study, the phantom is used to quantitatively evaluate the value of the amplitude according to couch change.

Practicability Assessment of Spherical Mechanical Check Device(SMCD) (Mechanical Check용 Spherical device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Yang, Dae-Sik;Kweon, Young-Ho;Ko, Shin-Gwan;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and radiation treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation treatment field. In order to accommodate the current trend of digital from analog, a spherical mechanical check device(SMCD) that is the form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. If the distance maintains constance between source(target) and image detector with constant distance to the center of spherical mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. In addition, it has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

Practicability Assessment of Spherical Type Mechanical Check Device (SMCD) (Mechanical Check용 Spherical Device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Kim, Gun-Oh;Kweon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.55-62
    • /
    • 2007
  • Purpose: Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and medical treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation therapy area. In order to accommodate the current trend of digital from analog, a spherical type mechanical check device (SMCD) that is form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. Materials and Methods: If the distance maintains constant between source(target) and image detector with constant distance to the center of spherical type mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. Results: It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. Conclusion: It has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

Evaluation of accuracy in the ExacTrac 6D image induced radiotherapy using CBCT (CBCT을 이용한 ExacTrac 6D 영상유도방사선치료법의 정확도 평가)

  • Park, Ho Chun;Kim, Hyo Jung;Kim, Jong Deok;Ji, Dong Hwa;Song, Ju Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.109-121
    • /
    • 2016
  • To verify the accuracy of the image guided radiotherapy using ExacTrac 6D couch, the error values in six directions are randomly assigned and corrected and then the corrected values were compared with CBCT image to check the accurateness of ExacTrac. The therapy coordination values in the Rando head Phantom were moved in the directions of X, Y and Z as the translation group and they were moved in the directions of pitch, roll and yaw as the rotation group. The corrected values were moved in 6 directions with the combined and mutual reactions. The Z corrected value ranges from 1mm to 23mm. In the analysis of errors between CBCT image of the phantom which is corrected with therapy coordinate and 3D/3D matching error value, the rotation group showed higher error value than the translation group. In the distribution of dose for the error value of the therapy coordinate corrected with CBCT, the restricted value of dosage for the normal organs in two groups meet the prescription dose. In terms of PHI and PCI values which are the dose homogeneity of the cancerous tissue, the rotation group showed a little higher in the low dose distribution range. This study is designed to verify the accuracy of ExacTrac 6D couch using CBCT. It showed that in terms of the error value in the simple movement, it showed the comparatively accurate correction capability but in the movement when the angle is put in the couch, it showed the inaccurate correction values. So, if the body of the patient is likely to have a lot of changes in the direction of rotation or there is a lot of errors in the pitch, roll and yaw in ExacTrac correction, it is better to conduct the CBCT guided image to correct the therapy coordinate in order to minimize any side effects.

  • PDF

Correction Method on Mismatched Posterior Edge of Medial and Lateral Tangential Fields for Three Fields Techniques in Breast Cancer (유방암 환자의 삼문 조사 시 내외측 접면 조사야의 Posterior Edge의 어긋남의 교정)

  • Kim Hun-Jung;Loh John JK;Kim Woo-Cheol;Park Sung-Young
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.174-181
    • /
    • 2003
  • Purpose: The target volume for the three field technique in breast cancer include the breast tangential and supraclavicular areas. The techniques rotating the gantry and couch angles, to match these two areas, will geometrically produce mismatching of the posterior edge between the medial and lateral tangential beams. This mismatch was confirmed by film dosimetry and three-dimensional computer planning. The correction methods of this mismatching were studied in this article. Materials and Methods: After the supraclavicular field was simulated using a half beam block and the medial and lateral tangential fields, by the rotation of the couch and gantry, we compared the following two methods to correct the mismatch. The first method was the rotation of coillmator until a line drawn on the posterior edge of tangential beams before the rotation of couch aligned the line drawn on the posterior edge after the rotation. The second method was the rotation of collimator according to the formula developed by the author as follows; Co=$2sin^{-1}${$sin\{theta}\{cdot}sin(C/2)$} (Co: collimator angle, $\theta$: angle between tangential beam and table, C: couch angle) Results: The film dosimetry showed the mismatching of posterior edges of the medial and lateral tangential fields prior to the rotation of collimator, while the posterior edges matched well after the rotation of collimator according to the formula. The three-dimensional computer plan also showed that the posterior edges matched well after the rotation of collimator accordingly. The DVH of the ipsilateral lung with the proper rotation of collimator angle was better than that without the rotation of collimator angle. Conclusion: The mismatching of the posterior edges of the medial and lateral tangential fields can be recognized on the three fileld technique in breast irradiation when the gantry and couch are simultaneously rotated and can be corrected with the proper rotation of the collimator angle. The radiation dose to the ipsilateral lung could be lowered with this technique.

3D 치료시 Couch rotation에 의한 Isocenter 변화에 대한 고찰

  • 박용철;주상규;송기원;정천영
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.144-146
    • /
    • 2000
  • 삼차원 입체조형치료는 정상조직의 장해를 최소화하고 종양부위에 집중적으로 조사할 수 있는 장점을 가지고 있어 임상 적용범위가 넓어지고 있다. 일반적으로 정상조직의 장해를 줄이기 위해 다양한 방사선 조사방향이 사용되며 특히 비 동일면상에서의 조사가 많이 이루어진다. 따라서 couch 회전이 동반되며 couch는 선형가속기의 다른 기계적 오차보다 많은 오차를 유발할 수 있는 잠재적인 위험을 안고 있다. 저자는 이러한 오차의 정도를 파악하고 이를 개선할 수 있는 방법에 대해 알아보고자 했다. couch 회전에 따른 Isocenter의 변화를 평가하기 위해 3대(Primus, Simens, USA/CL600c & 2100c, Varian, USA)의 선형가속기를 이용하였으며 이중 1대의 장비에는 couch 회전시 오차를 줄이기 위해 고안된 couch 고정장치를 장착하였다. 환자가 테이블에 부하를 주지 않은 상태에서 회전을 실시하여 Isocenter의 변화를 측정하고 환자가 테이블에 누워있는 상황을 재현하기 위해 human phantom을 위치시킨 후 동일한 회전검사를 실시하여 각각의 오차를 비교 분석하였다. 각 실험은 10회씩 반복 측정하여 평균치를 얻었으며 오차의 분석은 AAPM 권고안인 오차중심의 반경으로 표현했다. 3대의 선형가속기를 이용하여 얻은 결과 테이블에 부하를 주지 않은 상태의 회전오차는 평균 2mm, 3.2mm, 2mm로 측정되었으며 휴먼 phantom을 올려놓고 부하를 준 상태에서의 오차는 평균 2.1mm, 4mm, 2.1 mm이였다. 또한 고정장치를 이용한 상태에서의 평균오차는 1.9mm로 나타났다. 삼차원 입체조형치료 시 couch 회전에 따른 Isocenter 오차는 장비의 종류 및 작업자의 사용방법에 따라 다르게 나타났으며 테이블의 부하가 클수록 많은 오차를 보였다. 또한 couch 고정장치를 부착한 장비에서의 결과치 만이 AAPM에서 권고하는 오차의 한계에(${\le}2mm$) 들어감을 알 수 있었다. 따라서 정기적인 QA가 필수적이며 Couch Locking System과 같이 오차를 줄일 수 있는 보조장치의 부착이 많은 도움을 줄 것으로 생각된다. 아울러 이러한 오차를 보정할 수 있는 방법이 강구되어야 할 것으로 사료된다.