• Title/Summary/Keyword: Corrosiveness

Search Result 40, Processing Time 0.033 seconds

A Study on the Secular Change Characteristics of Grounding Systems (접지계의 경년변화 특성에 관한 연구)

  • Kim Jae-Yee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.224-226
    • /
    • 2005
  • In this paper, the secular changes of buried grounding electrodes was investigated; the electrodes are such facilities as grounding grid, grounding connector, grounding terminal and grounding rod etc.. The corrosiveness of removed substation grounding electrodes after commercial operation more than 50 years was measured and its conductivity deterioration trend was analyzed. The measuring results using three experimental methods were compared, finally the consideration for safe and economic grounding design were shown. As the result, it shows the maintenance necessity of grounding systems.

The Corrosiveness Evaluation according to the Needle Material in the Electroacupuncture Operation (전침 시술시 침 재료에 따른 부식성 평가)

  • Kwon, O-Sang;Choi, Kwang-Ho;Cho, Sung-Jin;Ryu, Yeon-Hee;Choi, Sun-Mi;Lee, Sang-Hoon
    • Korean Journal of Acupuncture
    • /
    • v.29 no.2
    • /
    • pp.216-223
    • /
    • 2012
  • Objectives : Electroacupuncture is widely used because of its diverse curative influence. However, its electrical safety is not guaranteed when applied on the human body. Therefore, in this study, we did research on the corrosiveness of electroacupuncture when applied on the body fluid. Methods : We did research using acupuncture needles which were made of STS304 or STS316 and which were coated or not coated in silicone. They were 0.25 mm in diameter and 40 mm in length. We immersed them to the depth of about 1cm in Hank's Solution and gave a stimulus in 120 Hz for 60 minutes. Then, we measured the pH of Hank's solution and mass of needles and observed their shape. Results : Acupuncture needles which were made of STS304 corroded more easily than those which were made of STS316 when they were applied on the human body. Acupuncture needles which were coated in silicone corroded much more easily than those which were not coated in silicone when they were applied on the body fluid. Conclusions : In this study, we did research on the corrosiveness of electroacupuncture when it is applied on the body fluid using several acupuncture needles. We made a conclusion that when acupuncture needles were applied on the body fluid, the coated one made of STS304 corrodes more easily than the uncoated one made of STS316. We hope that additional further researches on the effect of the corrosiveness of an acupuncture needle will be carried out.

Evaluation of Calcium Carbonate Saturation Indices in Water (상수 원수 수질의 탄산칼슘 포화지수 평가)

  • Hwang, Byung-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.1
    • /
    • pp.130-135
    • /
    • 2007
  • In order to examine the corrosiveness of tap water, we studied methods calculating various indices including calcium carbonate saturation indices, using RTW model and LPLWIN model. Indices such as LI, RI and AI could be computed using the RTW model, whereas the LPLWIN model could find indices as LI, LR and CCPP. With water quality data obtained from tap water of Han River and Nak-Dong River watersheds, based on the indices found from the models, the water quality of the Nak-Dong River is better than that of Han River in the point of resisting corrosiveness. Further, the water quality of winter is highly corrosive than that of summer, as long as the temperature rises up, the corrosiveness is reduced.

  • PDF

Effect of Residual Chlorine Concentration on Water Pipe Corrosion and Corrosion Control Plan (수도관 부식에 대한 잔류염소 농도 영향 및 부식제어 방안)

  • Han, Keum-Seok;Park, Ju-Hyun;Park, Young-Bok;Kim, Seong-Jae;Kim, Hyen-Don;Choi, Young-June;Choi, In-cheol;Hong, Seong-Ho
    • Corrosion Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.12-19
    • /
    • 2018
  • Langelier Index (LI) is used as a tap water corrosiveness index. Residual chlorine in tap water induces corrosion inside water pipes. This study takes a deeper look into the effect of residual chlorine in water pipes. Comparison between tap waters of Y and K water treatment plant (WTP) shows that the LI index of K WTP is lower than that of Y. However, the corrosion rate of Y WTP is higher than that of K WTP. This means that the higher the concentration of residual chlorine in tap water, the higher the corrosion rate of pipe materials. When calcium hydroxide was added to tap water, the corrosiveness index was improved and thus the corrosion rate reduced. It is possible to increase the disinfection efficiency by increasing the duration of residual chlorine and suppressing the rust generation of water pipes and to supply minerals. A guideline for corrosion control with residual chlorine should be set up. The effects of residual chlorine should be included in the corrosiveness index of tap water.

Attachment of Two-Way Shape Memory Alloy onto Fabric for Mass Production of Fire Fighters' Turnout Gear (지능형 소방복의 양산화를 위한 이방향 형상기억합금 부착 방법)

  • Park, Mi-Kyung;Lee, Ji-Yeon;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.4
    • /
    • pp.382-390
    • /
    • 2012
  • This study shows the optimum attachment of Two-Way Shape Memory Alloy (TWSMA) springs onto thermal liner and its sewing method for the mass production of fire fighter's intelligent turnout gear. SMA springs were attached to the fabric by four different methods and stitched by two different shapes (square and wave). The durability of the attached springs was tested by laundering up to 50 cycles. Examined were whether the springs would remain attached to the fabric after repeated laundering, the shape memory effect and reaction of the springs, and the anti-corrosiveness of the springs. A Human-Clothing-Environment simulator evaluated thermal insulation according to attachment methods, air layer volume, and stitch types. The findings showed that silicon attached springs remained intact after repeated laundering; in addition, repeated laundering did not influence the responsiveness and anti-corrosiveness of SMAs. Air volume had positive relations with the insulation. Attachment methods or stitch methods had limited impact on the thermal insulation. As a result, a wave type stitch with silicone attachment was suggested as the optimum method to attach the SMA springs onto the intelligent turnout gear for fire fighters.

Evaluation of Corrosion Properties of Several Metals in Waters for Reference Standard on Corrosion Rate - I. Andong Area (부식속도에 대한 참조 표준 작성을 위한 수환경에 따른 각종 금속의 부식특성 평가 - I. 안동지역)

  • Shim, G.T.;Kwon, Y.H.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.238-242
    • /
    • 2009
  • Corrosion of metallic materials occurs by the reaction with corrosive environment. In general, corrosive environments are classified as atmospheric, marine, soil etc. and regardless of any corrosive environments, reduction of thickness and cracking and degradation are induced by corrosion. Among several corrosive environments, knowing the atmospheric corrosiveness of a region, city, or country is considered of ultimate importance for major industrialists and investors who require knowledge of the corrosive impact of the atmosphere on everyday materials such as carbon steel, weathering steel, zinc, copper, and aluminium. This is why the atmospheric corrosiveness map is needed. This paper dealt with corrosion properties between several waters in the region and carbon steel, weathering steel, galvanized steel, pure copper, and pure aluminium at the representative rural area of Korea - Andong.

Control of the CaCO3 Saturation Index Parameters for Protecting the Corrosion of Waterworks Pipe (상수도관 부식방지를 위한 탄산칼슘 포화지수(LI) 인자 제어에 관한 연구)

  • Park, Young-Bok;Kong, Sung-Ho
    • Applied Chemistry for Engineering
    • /
    • v.16 no.3
    • /
    • pp.372-378
    • /
    • 2005
  • Calcium Carbonate Saturation Index (LI: Langelier Index), an indicator of $CaCO_3(s)$ saturation, indicates corrosiveness of drinking water and it has been used to monitor drinking water conditions in USA, E.U, and Japan. The objective of this research was to measure LI parameters including water temperature, pH, total alkalinity, calcium ion concentration, and electric conductivity, and to evaluate possibility of using LI in domestic system. Results showed that water temperature varied from 2.0 to $26^{\circ}C$ during 15 months, indicating an average annual temperature of $23.9^{\circ}C$. Total alkalinity was from 20 to 45 mg/L. The concentration difference between total alkalinity and $HCO_3{^-}$ value was hardly observed; the concentration of total alkalinity can be replaced by that of $HCO_3{^-}$. Tap water had a medium corrosiveness since LI values were from 2.0 to 0.5. To reduce the corrosiveness and to increase LI values of drinking water, the results of this study showed that chemicals such as $Ca(OH)_2$, $CaCO_3$, NaOH, or $NaHCO_3$ should be added to water treatment plants.

Techniques for Characterizing Surface Deterioration of Epoxy Exposed to Ozone Damage (오존에 노출된 에폭시 코팅재의 표면 열화특성 평가기술)

  • Choi, Sung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.167-177
    • /
    • 2014
  • New technologies for water purification are continuously emerging to address global water quality problems, and one such technology involves advanced hermetic water purification facilities made by concrete that utilize ozone treatment processes. Better knowledge about surface deterioration of epoxy coating exposed to ozone treatment is needed as a foundation for development of improved methods and materials in the future. This study utilized atomic force microscopy (AFM), nanoindentation methods, and existing indirect methods such as visual observation, changes in mass, surface observation and chrominance analysis, to evaluate epoxy water-resistance and anti-corrosiveness. This study considered six different epoxy formulations to assess typical degradation characteristics of epoxy surfaces with regard to water-resistance/anti-corrosiveness. AFM and nanoindentation techniques emerged as promising direct methods with potential to provide quantitative measures of surface quality that are improvements upon existing indirect methods. The experiments also confirmed that some of the epoxy-coatings were severely iMPacted by ozone exposure, and thus the results demonstrate that concern about such deterioration is justified.

Study on corrosion characteristics of treatment plants in Korea (국내 정수장의 부식성 특성 연구)

  • Min, Byung-dae;Chung, Hyen-mi;Lee, Lee-nae;Choi, Inchol;Ahn, Kyunghee;Park, Ju-hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.707-714
    • /
    • 2016
  • In order to prevent secondary pollution of tap water, corrosion characteristics are investigated, and corrosion index are calculated using LI and LR to manage corrosiveness. As targeted water treatment plants from 2014 (July, once) to 2015 (July and October, 2 times), 70 plants are selected by making a division for each area and water system. (treated water samples, n=240, raw water samples, n=72). In result of pH analysis, treated water was lower than raw water to 7.12, and 7.29, respectively. LI were investigated in the order of Seomjin river, Nakdong river, Han river, Geum river, to -2.08, -1.24, -1.11, -1.10 (at raw water), and -2.18, -1.59, -1.51, -1.35 (at treated water), respectively. In case of water quality goal value (LI = -1) in Japan as control of corrosiveness, management object was investigated about 83.3%.

Water Quality Variation and Corrosion Index Characteristics of Underground Reservoir in Apartment (공동주택 지하저수조의 수질변화 및 부식성 특성)

  • JunYoung, Jang;JooWon, Kim;YuHoon, Hwang;KiPal, Kim;HyunSang, Shin;ByungRan, Lim
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.6
    • /
    • pp.275-281
    • /
    • 2022
  • To maintain water quality after water treatment, monitoring whether the quality of treated tap water quality changes is essential. However, current investigations are insufficient to prevent secondary contamination in drinking water supply systems. This study investigated Gyeonggi's e apartment where a red water problem occurred and monitored the water quality and corrosiveness of the overall water supply system to the apartment from June 2021 to April 2022. In a comparison of drinking water quality after water treatment and the influent of the reservoir, turbidity and heavy metal concentrations were increased and residual chlorine was decreased due to increases in temperature. Correlation analysis and principal component analysis (PCA) indicated that a low level of residual chlorine may cause the abscission of Mn2+ and Fe2+ through microorganism activation, which also causes a high level of turbidity. The corrosion index (LI) in the influent of the reservoir tank was increased due to Ca2+ and temperature. These results indicate that the corrosiveness of drinking water and the deterioration of drinking water quality were mainly increased between the drinking water treatment plant and the reservoir tank's influent. The findings provide clear evidence that it is essential to manage water supply systems and reservoir tanks to prevent the secondary contamination of drinking water.