• Title/Summary/Keyword: Corrosion-damage

Search Result 627, Processing Time 0.032 seconds

A Chloride Ion Diffusion Model in Blast Furnace Slag Concrete (고로슬래그 미분말 콘크리트의 염화물이온 확산모델)

  • 이석원;박상순;송하원;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.467-472
    • /
    • 2000
  • It is known that chloride ion in concrete destroys the passive film of reinforcement inside concrete and accelerates corrosion which is the most influencing factor to durability of concrete structures. In this thesis, a chloride ion diffusion model for blast furnace slag(BFS) concrete, which has better resistance to both damage due to salt and chloride ion penetration than ordinary portland cement concrete, is proposed by modifying existing model of normal concrete. Proposed model is verified by comparing diffusion analysis results with both results by indoor chloride penetration test for specimens and field test results for actual RC bridge pier. Also, the optimum resistance condition to chloride penetration is obtained according to degrees of fineness and replacement ratios of BFS concrete. As a result, resistance to chloride ion penetration for BFS concrete is more affected by replacement ratio than degree of fineness.

  • PDF

Residual Shear Strength Evaluation for RC Beam Member (RC 보 부재의 잔존 전단강도 평가)

  • Myung, Gun-Hak;Rhee, Chang-Shin;Kim, Dae-Joong;Mo, Gui-Suk;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.283-286
    • /
    • 2005
  • Recently, the deterioration of concrete structures have been increased by the damage from salt, carbonization, freezing & thawing and the others. Reinforcement corrosion is the principal cause of deterioration of reinforced concrete. Unfortunately, full bond is assumed in all existing shear models, a condition which is often not fulfilled when assessing damaged structures. It is therefore very important to increase the understanding of how reduced bond influences the load carying capacity particularly for shear. Therefore in this study an equation is proposed to evaluate the residual shear strength considered deterioration.

  • PDF

Evaluation of Chloride Resistance with Application Method of Coating Materials Using Electric Acceleration Test (코팅재료의 도포 특성에 따른 전기적 촉진을 통한 염해 저항성 평가)

  • Kim Myung Yu;Yang Eun Ik;Yeon Kyu Seok;Joo Myung Ki
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.551-554
    • /
    • 2005
  • The durability of concrete is decreased by various deterioration factors such as a crack, spalling, corrosion. Many repair and rehabilitation methods have been introduced to extend service life of RC structure. An application of coating material is one of repair and rehabilitation methods. However, there is a problem due to reduction of bonding strength and damage of coating material in the case of existed coating material. Thus, this paper is aim to investigate the chloride resistance according to application method of coating material which improve the existed problem. According to the results, it is showed that application of coating material reduces diffusion of chloride into concrete. In special, application of MMA polymer showed the best resistance for chloride attack. However, variation of application method and number of times has a minor effect on chloride diffusion.

  • PDF

Forced Ventilation Method for Preventing Surface Condensation of Magazine of Igloo type in Summer (강제환기를 이용한 하절기 군 저장시설의 표면결로 방지에 관한 연구)

  • Park, Sun-Hyo;Yoon, Sung-Do;Sohn, Jang-Yeul
    • KIEAE Journal
    • /
    • v.10 no.2
    • /
    • pp.57-62
    • /
    • 2010
  • In case of earth-covered storage, the condensation occurs on surface of wall and stores in summer with high humidity because of low temperature of constructional mass. Therefore, the preventive plans should be considered to protect stores from the damage by corrosion in earth-covered storages. This study aims to suggest the methods of forced ventilation by the air, to solve the problems of construction's surface condensation at the Magazine of igloo type which is similar to earth-covered storages. A fan was installed at the air outlet for exhaust gas to conduct forced ventilation. The surface and indoor temperature were measured, and then the influence of those on condensation was analyzed. The results of this research are follows; 1) Forced ventilation by a fan affects the rise in surface temperature of walls and stores. 2) The condensation on surface of walls and stores was reduced after operating a fan.

Fracture Behavior Evalustion of Pipes with Local Wall Thinning (감육배관의 파괴거동 평가)

  • Ahn, S.H.;Nam, K.W.;Kim, S.J.;Kim, H.S.;Kim, J.H.;Do, J.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.61-66
    • /
    • 2001
  • Fracture behaviors of pipes with local wall thinning is very important for the integrity of nuclear power plant. In pipes of energy plants, sometimes, the local wall thinning may result from severe drosion-corrosion damage. However, effect of local wall thinning on strength and fracture behaviors of piping system were not well studied. In this paper, the monotonic bending tests were performed of full-scale carbon steel pipes with local wall thinning. A monotonic bending load was applied to straight pipe specimens by four-point loading at ambient temperature without internal pressure. From the tests, fracture behaviors and fracture strength of locally thinned pipe were manifested systematically. The observed failure modes were divided into four types; ovalization, ovalization+cracking, local buckling and local buckling+cracking. Also, maximum load was successfully evaluated.

  • PDF

Fracture Behavior of Welded Pipes with Local Wall Thinning (감육을 가지는 배관 용접부의 파괴거동)

  • Ahn, Seok-Hwan;Nam, Ki-Woo;Jeong, Jeong-Hwan;Kim, Yong-Un
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.90-95
    • /
    • 2003
  • Fracture behaviors of pipes with local wall thinning are very important for the integrity of nuclear power plant. In pipes of energy plants, sometimes, the local wall thinning may result from severe erosion-corrosion (E/C) damage. However, the effects of local wall thinning on strength and fracture behaviors of piping system were not well studied. In this paper, the monotonic bending tests were performed of full-scale welded and unwelded carbon steel pipes with local wall thinning. A monotonic bending load was applied to straight pipe specimens by four-point loading at ambient temperature without internal pressure. The observed failure modes were divided into four types; ovalization, crack initiation/growth after ovalization, local buckling and crack initiation/growth after local buckling. Also, the strengths of welded and unwelded piping system with local wall thinning were evaluated.

  • PDF

Evaluation of the Corroded Pipe by Time-Frequency Analysis (시간-주파수 해석에 의한 부식된 배관의 평가)

  • Ahn, S.H.;Kim, J.W.;Do, J.Y.;Nam, K.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.2
    • /
    • pp.89-92
    • /
    • 2006
  • In this study, the pressure vessel piping with corrosion used during long term were investigated from the time-frequency analysis method. The damage of piping could be evaluated the attenuation factor by ultrasonic parameters such as center frequency and echo waveform. Based on NDE analysis by time-frequency analysis method, it should also be possible to evaluate from various damages and defects in piping members.

  • PDF

A study on the safety of the Environment Corrosion of Suspension Insulater of a Catenary Trolley Wire Systems (카테나리 전차선로 현수애자의 환경부식에 따른 안전성 연구)

  • Lee, Jae-Bong;So, Sun-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.864-874
    • /
    • 2007
  • Suspension insulator in Catenary Trolley Wire Systems must have two characteristics, electric insulation and mechanical endurance. Because suspension insulator is used in supporting and insulating position between power supply parts and earth conducted supporting parts. The insulator's electric characteristics can be influenced by surface pollution and damage from the environment such as humidity, dust, smoke, salt. etc. And, the insulating parts can be electrically short. These electrically damaged insulator can cause serious accidents that have far-reaching effect. So appropriate management basis of suspension insulator is needed. And we present appropriate cleaning and the changing period of suspension insulator on the basis of actual data.

  • PDF

Finite Element Analysis of Copper Clad Steel Wire Drawing Process (동피복 강 선재 인발 공정의 유한요소해석)

  • Kim H. S.;Kim B. M.;Jo H. H.;Jo H.
    • Transactions of Materials Processing
    • /
    • v.14 no.2 s.74
    • /
    • pp.147-152
    • /
    • 2005
  • The objective of this study is to develop an optimal drawing die for the clad wire drawing process. Cu-clad wire, which has the advantages of the high strength of a steel core and the electro-conductivity, corrosion resistance of a copper layer, is widely being used in the field of the telecommunications, electric-electronic and military technology industries. It is important to obtain uniformly coated rate when producing clad wires. Drawing process of clad wire will be influenced on damage and coated rate of core and sleeve for process variables such as semi-die angle and reduction in area. Therefore, in this study, the finite-element result obtained in this study was analyzed to the effect of the various forming parameters, which included the semi-die angle and reduction in area. The coated rate will be predicted with observation of copper coated rate variation according to total reduction in area and the optimal pass schedule will be set up through proper reduction in area and semi-die angle variation.

Diagnosis of Crack Occurrence of Very-Early Strength Latex-Modified Concretes through Field Tests (현장실험을 통한 VES-LMC 균열발생 원인분석)

  • Choi, Pan-Gil;Lee, Bong-Hak
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.139-146
    • /
    • 2006
  • Many concrete bridge decks develop transverse cracking shortly after construction. These cracks accelerate corrosion of reinforcing steel and lead to concrete deterioration, damage to components beneath the deck, unsightly appearance. These cracks shorten the service life and increase maintenance costs of bridge structures. In this study, VES-LMC overlay, which provides the same benefits as a conventional overlay, is designed to cure very quickly. Although the materials for VES overlays are more expensive, the cost is more than offset by the savings on traffic control and work zone safety measures. Otherwise, reaction of hydration occurs very rapidly in beginning step(concrete placing). As a results, thermal cracking can be occur by thermal stress in accordance with hydration-heat The purpose of this study was to estimate diagnosis of crack occurrence of VES-LMC through field tests at early-age.

  • PDF