• Title/Summary/Keyword: Corrosion-damage

Search Result 627, Processing Time 0.029 seconds

A Study on the Performance Development of Sewage Concrete by Application of Antibiotics (항균제 도포에 의한 하수시설 콘크리트의 성능향상에 관한 연구)

  • Kim, Moo-Han;Kim, Gyu-Yong;Khil, Bae-Su;Cho, Bong-Suk;Lee, Eui-Bae
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.371-378
    • /
    • 2006
  • Recently sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. In this study, to prevent biochemical corrosion of the sewer concrete, antibiotics which prevent growth of sulfur-oxidizing bacteria were developed and antimicrobial performance of it was investigated. After that, to consider applicability of antibiotics to concrete, physical properties of concrete covered with antibiotics were investigated. As a results of the study, it was proved that the antimicrobial performance of antibiotics was available. Also compressive strength and bond strength of concrete didn't closely connected with antibiotics, and resistance to abrasion, water absorption, air permeability, carbonation, salt damage and chemical attack of concrete was improved remarkably by covering with it.

Chloride Diffusion in Hardened Concrete with Concrete Properties and Testing Method (콘크리트 물성 및 시험법에 따른 콘크리트 염화물 확산)

  • Yang Eun-Ik;Kim Myung-Yu;Min Seok-Hong
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.261-268
    • /
    • 2004
  • Corrosion of reinforcement is the main cause of damage and early failure of reinforced concrete structures. The corrosion is mainly progressed by the chloride ingress. In this paper, an experimental study is executed to investigate the effect of concrete properties and testing methods on the coefficients of chloride diffusion. Also, it is surveyed the relationship between total chloride and free chloride in concrete. According to this experiment results, W/C ratio and testing method affect chloride diffusion coefficient of concrete. As W/C ratio is increased, diffusion coefficient in concrete is also increased. Diffusion coefficient obtained by each testing method show the different values, respectively. The model equation of diffusion coefficient with W/C ratio is proposed.

Integrated Fitness-for-service Program for Natural Gas Transmission Pipeline (천연가스 공급배관의 사용적합성 통합프로그램)

  • Kim, Woo-Sik;Kim, Young-Pyo;Kim, Cheol-Man;Baek, Jong-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.269-274
    • /
    • 2008
  • For fitness-for-service analyses of underground natural gas pipelines, engineering assessment methods against possible defects need to be developed. The assessment methods for high pressure pipeline of KOGAS, was developed using the full size pipe burst tests and the finite element analysis. It included the defect assessment methods for a single and multi-corrosion, corrosion in girth welding part, corrosion in seam welding part, the mechanical damage defects as dent and gouge, crack and large plastic deformation of API 5L X65 pipe. In addition, we developed method to assess pipeline integrity by internal and external load to buried pipeline. Evaluation results were compared with other methods currently being applied to the gas pipeline. The program of Windows environment is made for easily using assessment methods. It provides a consistent user interface, so non-professional technician can easily and friendly use the FFS program from company intranet. Several evaluation programs is easily installed using one installer. Each program constitutes a common input interface and the output configuration program, and evaluation result store and can be recalled at any time. The FFS program based on independent evaluation method is used to evaluate the integrity and safety of KOGAS pipeline, and greatly contribute to safe and efficient operation of pipeline. This paper presents experimental, analytical and numerical investigations to develop the FFS methods for KOGAS pipeline, used as high pressure natural gas transmission pipeline within KOREA. Also, it includes the description of the integrated program for FFS methods.

  • PDF

Characterization on corrosion damage of nickel alloy for nuclear energy instrument by chemical decontamination solution (원전기기용 니켈합금강의 화학제염용액에 따른 부식손상 특성 규명)

  • Park, Il-Cho;Yang, Ye-Jin;Jeong, Gwang-Hu;Lee, Jeong-Hyeong;Han, Min-Su;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.135-135
    • /
    • 2017
  • 제염기술은 원자력발전소의 순환계통장치 및 기기류의 방사성 오염물질을 제거하는 기술이다. 현재 국내 원전의 설계 수명 및 유지보수 시기가 도래함에 따라, 작업 전 작업자의 방사선 피사량을 극소화하기 위한 제염 기술이 주목을 받고 있다. 제염 방법에는 크게 기계적 제염과 화학약품을 사용하는 화학제염이 있다. 그 중 화학제염은 복잡한 구조의 제염 대상물에 대한 큰 효과 및 간단한 공정 때문에 주로 사용되고 있다. 제염 시 방사성 산화물과 오염성분을 제거하기 위해 강산 또는 강알칼리의 화학용액이 사용된다. 강한 화학약품을 사용함으로써 큰 제염효과를 얻을 수 있는 반면, 금속 재료의 부식에 대한 구동력도 커지게 된다. 금속 재료의 경우, 강한 부식성 환경에서 공식(pitting corrosion) 및 입계부식(intergranular corrosion)형태의 손상이 크게 발생하기 때문에, 제염공정 시 사용되는 화학용액에 대한 재료의 건전성 검증이 반드시 필요하다. 본 연구에서는 원전기기용 재료인 니켈합금강 Inconel600의 화학제염 시 시험공정 3가지에 대한 부식손상 특성을 규명하였다. 산화공정은 $HMnO_4$ 실험용액을 공통으로 사용하였으며, 산화공정 종료 후 환원공정은 각 시험공정에 따라 환원공정 1은 2000ppm $H_2C_2O_4$, 환원공정 2는 1500ppm $H_2C_2O_4$ + 500ppm $H_8C_6O_7$, 그리고 환원공정 3은 3000ppm $H_2C_2O_4$ 실험용액을 각각 투입하여 수행하였다. 산화, 환원공정을 1Cycle로 하여 온도 $75^{\circ}C$로 유지된 용액에 각 2시간씩 침적하였다. 각 시험공정 별로 총 5Cycle을 실시하였다. 각 시험공정 Cycle종료 후 시험편을 취외하여 무게감량측정, SEM(Scanning electron microscope)분석, 3D현미경분석 그리고 타펠분극 실험을 실시하였다. 각 분석결과를 토대로 하여, 니켈합금 Inconel600에 대한 화학제염 시 시험공정에 따른 부식특성을 규명하였다.

  • PDF

Effects of Rectifier and Copper Grid Interference on the Detection Reliability of Coating Flaws on Buried Pipes (매설 배관 피복 결함 탐상 정확도에 미치는 인접 정류기 및 접지 구리망 간섭의 영향)

  • Kim, M.G.;Lim, B.T.;Kim, K.T.;Chang, H.Y.;Park, H.B.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.211-223
    • /
    • 2020
  • The external corrosion of buried piping can be controlled using both coating and cathodic protection. Several factors are involved in the damage and deterioration of the coating on pipes. There are many detection methods for coating defects on pipes and the direct current voltage gradient (DCVG) method is one of the most powerful methods. However, the detection reliability of DCVG can be affected by interferences such as stray current, metal objects connected to rectifiers, and copper grids. Therefore, this study focused on the interference effects of rectifiers and a copper grid on the reliability of coating flaw detection. As the length of the interference pipe connected to the rectifier increased, the reliability decreased. In contrast, as the distance between the pipe and the copper grid increased, the reliability of the coating flaw detection increased. The detection results produced by the DCVG method were discussed using current and potential simulations for a pipe with a rectifier and copper grid interference in the soil.

Determining the Wood (Parashorea spp.) Decaying and Metal Corroding Abilities of Eight Fungi

  • SUPRAPTI, Sihati;DJARWANTO, DJARWANTO;DEWI, Listya Mustika
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.50-60
    • /
    • 2020
  • Fungi are wood-decaying organisms, and this is an important trait that should be considered in wood utilization. When fungi attack wood, it decreases the quality of the wood. The use of metal screws has become an important part of woodworking. The ability of fungi to decay wood and damage metal screws that are embedded into wood is varied. In this study, eight fungal species were evaluated with respect to their ability to decay Parashorea smythiesii and P. tomentella wood. In addition, the effect of fungi on corroding metal screws was determined using the Kolle flask method. The evaluation showed that the fungal species Schizophyllum commune, Pycnoporus sanguineus, and Polyporus arcularius were highly capable of decaying Parashorea spp. woods. The greatest wood weight loss occurred with the heartwood of P. tomentella exposed to S. commune. Based on the classification of wood resistance against fungal attack, the two Parashorea spp. were classified as moderately resistant woods (class III). Schizophyllum commune was classified as highly capable of decaying wood that was embedded with metal screws and was highly capable of corroding metal screws placed in fungi-culture media. The greatest weight of rust powder formed because of screw corrosion was obtained from screw-embedded wood exposed to S. commune. Additionally, the most severe corrosion of metal screws that were embedded into woods was caused by the activities of P. arcularius. Moreover, the average weight loss of screw-embedded wood was greater than that of unscrewed wood.

Evaluations of Microstructure and Electrochemical Anodic Polarization of AISI 304L and AISI 316L Stainless Steel Weld Metals with Creq/Nieq Ratio (Creq/Nieq비에 따른 AISI 304L 및 AISI 316L 스테인리스강 용접부의 미세조직 및 전기화학적 양극분극 평가)

  • Kim, Yeon Hee;Jang, Ah Young;Kang, Dong Hoon;Ko, Dae Eun;Shin, Yong Taek;Lee, Hae Woo
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.12
    • /
    • pp.1090-1096
    • /
    • 2010
  • This pitting corrosion study of welded joints of austenitic stainless steels (AISI 304L and 316L) has addressed the differentiating solidification mode using three newly introduced filler wires with a flux-cored arc welding process (FCAW). The delta ferrite (${\delta}$-ferrite) content in the welded metals increased with an increasing equivalent weight ratio of chromium/nickel ($Cr_{eq}/Ni_{eq}$). Ductility dip cracking (DDC) was observed in the welded metal containing ferrite with none of AISI 304L and 0.1% of AISI 316L. The potentiodynamic anodic polarization results revealed that the $Cr_{eq}/Ni_{eq}$ ratio in a 3.5% NaCl solution didn't much affect the pitting potential ($E_{pit}$). The AISI 316L welded metals with ${\ddot{a}}$-ferrite content of over 10% had a superior $E_{pit}$ value. Though the AISI 316L welded metal with 0.1% ferrite had larger molybdenum contents than AISI 304L specimens, it showed a similar $E_{pit}$ value because the concentration of chloride ions and the corrosion product induced severe damage near the DDC.

Effects of Proton Irradiation on the Microstructure and Surface Oxidation Characteristics of Type 316 Stainless Steel (양성자 조사가 316 스테인리스강의 미세조직과 표면산화 특성에 미치는 영향)

  • Lim, Yun-Soo;Kim, Dong-Jin;Hwang, Seong Sik;Choi, Min Jae;Cho, Sung Whan
    • Corrosion Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.158-168
    • /
    • 2021
  • Austenitic 316 stainless steel was irradiated with protons accelerated by an energy of 2 MeV at 360 ℃, the various defects induced by this proton irradiation were characterized with microscopic equipment. In our observations irradiation defects such as dislocations and micro-voids were clearly revealed. The typical irradiation defects observed differed according to depth, indicating the evolution of irradiation defects follows the characteristics of radiation damage profiles that depend on depth. Surface oxidation tests were conducted under the simulated primary water conditions of a pressurized water reactor (PWR) to understand the role irradiation defects play in surface oxidation behavior and also to investigate the resultant irradiation assisted stress corrosion cracking (IASCC) susceptibility that occurs after exposure to PWR primary water. We found that Cr and Fe became depleted while Ni was enriched at the grain boundary beneath the surface oxidation layer both in the non-irradiated and proton-irradiated specimens. However, the degree of Cr/Fe depletion and Ni enrichment was much higher in the proton-irradiated sample than in the non-irradiated one owing to radiation-induced segregation and the irradiation defects. The microstructural and microchemical changes induced by proton irradiation all appear to significantly increase the susceptibility of austenitic 316 stainless steel to IASCC.

Optimal Coating Materials and Methods to Enhance Interfacial Bonding with Steel Pipes in Marine Environments (해양 환경 노출 코팅 강관의 부착성능 확보를 위한 최적 코팅 및 공법연구)

  • Myung Kue Lee;Dongchan Kim;Min Ook Kim
    • Composites Research
    • /
    • v.37 no.4
    • /
    • pp.265-274
    • /
    • 2024
  • This study reviews previous research on various coating materials and methods designed to improve the adhesion and durability of steel pipes exposed to real-world marine environments, with the goal of identifying optimal solutions. The results concerning the adhesion and corrosion resistance of the pipes were categorized and analyzed based on exposure tests in extreme marine conditions to evaluate their stability. Furthermore, a detailed microstructural analysis of the coatings applied to the pipes was performed to assess surface damage, including peeling and delamination. The findings confirmed that coatings effectively prevent corrosion and provide sufficient adhesion and durability. Based on these results, we have proposed suitable coating materials, types, and application methods for steel pipes used in marine environments and offered recommendations for future exposure tests.

The Condition Evaluation of Mortar Parts of Stupa of State Preceptor Jigwang from Wonju Beopcheonsa Temple Site by Half Cell Potential Measurement - with Focus on the Mortar Parts the RoofStone - (반전위 측정을 통한 원주 법천사지 지광국사탑 모르타르 복원부위 상태평가 연구 - 옥개석 모르타르 복원부위를 중심으로 -)

  • Lee, Tae Jong;Cho, Ha Jin;Park, Hee Jeong;Chae, Seung A
    • Journal of Conservation Science
    • /
    • v.34 no.6
    • /
    • pp.503-515
    • /
    • 2018
  • Stupa of State Preceptor Jigwang at Beopcheonsa temple site, Wonju, was conserved and restored in 1957. It was necessary to assess the degree of damage to the used mortar and to provide objective data on the necessity of its removal. Therefore, the HCP(half-cell potential) measurement used in concrete fields was applied. Multi-regression analysis of HCP data, following the rapid corrosion test of the roofstone mortar used by the rebar, resulted in a high correlation of HCP values(0.86), depending on the amount of corrosion and cover depth used for the steel bar. As a result, high correlation values(0.86) for the coefficients of determination were derived. The showed that the measurement of the wet conditions -431 to -663 mV on the roofstone indicated a corrosion damage rate of 90% or more after removal and restoration.