• Title/Summary/Keyword: Corrosion resistant

Search Result 270, Processing Time 0.022 seconds

Effect of Area Ratio on Galvanic Corrosion Between Metallic Materials and GECM in 3.5% NaCl Solution (3.5% NaCl 수용액 중에서의 금속과 GECM의 갈바닉 부식에 미치는 면적비의 영향)

  • Kim, Y.S.;Lim, H.K.;Sohn, Y.I.;Yoo, Y.R.;Chang, H.Y.
    • Corrosion Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.39-47
    • /
    • 2010
  • Galvanic coupling between GECM(graphite epoxy composite material) and metallic materials can facilitate corrosion of metals and alloys because GECM is noble and electrically conductive. Galvanic corrosion is affected by many factors including metallic materials, area ratio, surface condition, and corrosivity. This work aims to evaluate the effect of area ratio on galvanic corrosion between GECM and several metals. In the case of glavanic coupling of carbon steel and Al to GECM, corrosion rate increased with increasing area ratio. Corrosion rate of sensitized STS 316S stainless steel decreased a little at an area ratio 1:1 but increased at an area ratio 30:1. It is considered to be due to that area ratio affects galvanic corrosion more in less corrosion resistant alloys. However, in case of STS 316 and Ti, galvanic coupling reduces corrosion rate by the formation of passive film.

Corrosion Mechanism and Bond-Strength Study on Galvanized Steel in Concrete Environment

  • Kouril, M.;Pokorny, P.;Stoulil, J.
    • Corrosion Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.69-75
    • /
    • 2017
  • Zinc coating on carbon steels give the higher corrosion resistance in chloride containing environments and in carbonated concrete. However, hydrogen evolution accompanies the corrosion of zinc in the initial activity in fresh concrete, which can lead to the formation of a porous structure at the reinforcement -concrete interface, which can potentially reduce the bond-strength of the reinforcement with concrete. The present study examines the mechanism of the corrosion of hot-dip galvanized steel in detail, as in the model pore solutions and real concrete. Calcium ion plays an important role in the corrosion mechanism, as it prevents the formation of passive layers on zinc at an elevated alkalinity. The corrosion rate of galvanized steel decreases in accordance with the exposure time; however, the reason for this is not the zinc transition into passivity, but the consumption of the less corrosion-resistant phases of hot-dip galvanizing in the concrete environment. The results on the electrochemical tests have been confirmed by the bond-strength test for the reinforcement of concrete and by evaluating the porosity of the cement adjacent to the reinforcement.

The corrosion-resistant of Al-coated xstainless in molten carbonate (알루미늄 코팅처리 스테인레스강의 융탄산염 내부식성)

  • 조남웅;장세기;전재호;신정철
    • Journal of the Korean institute of surface engineering
    • /
    • v.31 no.1
    • /
    • pp.3-11
    • /
    • 1998
  • Molten Carbonate Fuel cell is a promising new type electric power generation system which can achieve high efficiency, lower matrrial cost and high operating temperature Making internal reforming possible. Although the development of the MCEC is progressing rapidly toward commercialization, two important tchological problems such as dissolution of NiO cathode and not corrosion of metallic separator plate must be resolved. Because MCFC is operated at $650^{\circ}C$ and the electrolyte is very corrosive, corrosion-resistance of separator plated against oxidation abd molten carbonate is required. Al-coating on separator material for corrosion-resistance was carried out by painting, thermal spraying. hot dipping and vacuum vapour deposition. The corrosion of Al-coated STS 316S and 316L in molten carbonate at $700^{\circ}C$was studied. Vacuum vapour deposition and thermal spraing for Al-coating on STS 310S and 316L were the most effective methods for protecting thestainless steel corrosion in molten carbonate.

  • PDF

Corrosion Behavior of Heat-Resistant Alloys of More 1 and Super 22H in Molten Salt of LiCl and LiCl-$Li_2O$ (용융염 LiCl 및 LiCl-$Li_2O$에서 내열합금 More 1과 Super 22H의 부식거동)

  • Jo, Su-Haeng;Park, Sang-Cheol;Jang, Jun-Seon;Sin, Yeong-Jun;Park, Hyeon-Su
    • Korean Journal of Materials Research
    • /
    • v.9 no.6
    • /
    • pp.556-563
    • /
    • 1999
  • The corrosion behavior of heat-resistant alloys, More 1 and Super 22H in molten salts of LiCl and $LiCl-Li_2$O was investigated in the temperature range of $650~850^{\circ}C$. In a molten salt of LiCl, a dense protective oxide scale of $LiCrO_2$ was formed, following growth of oxide scale with parabolic kinetics. But in a mixed molten salt of LiCl, a dense protective oxide scale of $LiCrO_2$ was formed, following growth of oxide scale with parabolic kinetics. But in a mixed molten salt of $LiCl-Li_2$O, a porous non-protective scale of Li\ulcorner(Cr, Ni, Fe)\ulcornerO$_2$was formed, following growth of oxide scale with linear kinetics. The corrosion rate increased slowly with the increase of temperature up to $750^{\circ}C$, but above $750^{\circ}C$ rapid increase in corrosion rate observed. The corrosion behavior of Super 22H alloy was similar to that of More 1 alloy, but Super 22H showed higher corrosion resistance than More 1.

  • PDF

Corrosion Behavior of Cr-bearing Corrosion Resistant Rebar in Concrete with Chloride Ion Content

  • Tae, Sung Ho
    • Architectural research
    • /
    • v.7 no.1
    • /
    • pp.49-54
    • /
    • 2005
  • Conventional studies have focused on the reduction in the water-cement ratio, the use of various admixtures, etc., to ensure the durability of reinforced concrete structures against such deterioration factors as carbonation and chloride attack. However, improvement in the concrete quality alone is not considered sufficient or realistic for meeting the recent demand for a service life of over 100 years. This study intends to improve the durability of reinforced concrete structures by improvement in the reinforcing steel, which has remained untouched due to cost problems, through subtle adjustment of the steel components to keep the cost low. As a fundamental study on the performance of Cr-bearing rebars in steel reinforced concrete structures exposed to corrosive environments, The test specimens were made by installing 8 types of rebars in concretes with a chloride ion content of 0.3, 0.6, 1.2, 2.4 and $24kg/m^3$. Corrosion accelerated curing were then conducted with them. The corrosion resistance of Cr-bearing rebars was examined by measuring crack widths, half-cell potential, corrosion area and weight loss after 155 cycles of corrosion-accelerating curing. The results of the study showed that the corrosion resistance increased as the Cr content increased regardless of the content of chloride ions, and that the Cr-bearing rebars with a Cr content of 5% and 9% showed high corrosion resistance in concretes with a chloride ion content of 1.2 and $2.4kg/m^3$, respectively.

AN ELECTROCHEMICAL STUDY ON THE CORROSION OF DENTAL AMALGAM (치과용 아말감의 부식(腐蝕)에 관한 전기화학적 연구)

  • Chang, Gye-Bong
    • Restorative Dentistry and Endodontics
    • /
    • v.6 no.1
    • /
    • pp.115-122
    • /
    • 1980
  • The corrosion of silver amalgam is regarded as one of major causes in the failures of dental amalgam restorations. To evaluate the corrosion resistance of dental amalgam alloys, electrochemical tests such as potential and polarization measurement were used widely. But these commonly used methods have not provided the sufficient informations on relative resistance of amalgam to corrosion. In this experiment, the corrosion currents were measured using electronic potentiostat to compare some commercial dental amalgam alloys. All alloys were triturated in a amalgamator and condensed into a mold described in A.D.A. Specification No. 1 to produce cylinder form specimens of 4mm diameter by 5mm long. After specimen kept for 1 week at $37^{\circ}C$, each specimen was embedded in epoxy resin. The surfaces of specimens were then polished with a emery paper, diamond dust, and $Al_2O_3$. These specimens were immersed in artifical saliva kept at $37^{\circ}C$, and currents of each specimen were measured for 24 hours at 0.0volt (SCE). The author obtained conclusions as follows: 1. High copper amalgam showed superior resistance against corrosion to conventional amalgam, but a pellet form of high copper amalgam seemed to be susceptible to corrosion. 2. In lathe-cut alloys, fine-cut had superior resistance against corrosion to regular-cut. 3. Non-zinc conventional amalgam alloys were more resistant to corrosion than that of zinc containing conventional amalgam alloys. 4. In both of high copper and conventional amalgams, predispensed forms tended to have better resisitance to corrosion than that of pellet forms.

  • PDF

Corrosion resistant self-compacting concrete using micro and nano silica admixtures

  • Jalal, Mostafa
    • Structural Engineering and Mechanics
    • /
    • v.51 no.3
    • /
    • pp.403-412
    • /
    • 2014
  • In this paper, enhancement of corrosion and chloride resistance of high performance self compacting concrete (SCC) through incorporating nanosilica into the binder has been investigated. For this purpose, different mixtures were designed with different amounts of silica fume and nano silica admixtures. Different binder contents were also investigated to observe the binder content effect on the concrete properties. Corrosion behavior was evaluated by chloride penetration and resitivity tests. Water absorption and capillary absorption were also measured as other durability-related properties. The results showed that water absorption, capillary absorption and Cl ion percentage decreased rather significantly in the mixtures containing admixtures especially blend of silica fume and nano silica. By addition of the admixtures, resistivity of the SCC mixtures increased which can lead to reduction of corrosion probability.

Study on the Characteristics of Cavitation Erosion-Corrosion for Mild Steel ( 2 ) - Damage Behaviour of Vibration Cavitation Erosion-Corrosion - (연강의 캐비테이션 침식-부식 특성에 관한 연구 ( 2 ) - 진동 캐비테이션 침식-부식 손상 거동 -)

  • Hwang, Jae-Ho;Lim, Uh-Joh
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.3
    • /
    • pp.302-309
    • /
    • 1996
  • Cavitation erosion-corrosion implies damage to materials due to the shock pressure or shock wave that results when bubbles form and collapse at a metal surface within a liquid. If the liquids corrosive to the material, a condition typically encountered in industry, the component materials may suffer serious damage by a combination of mechanical and electrochemical attack. To suppress cavitation erosion as well as cavitation erosion-corrosion to hydraulic equipments, innovations such as the improvement in the geometric design of the equipment or the selection of suitably resistant construction materials are necessary. This study was tested by using the piezoelectric vibrator with 20kHz, 24${\mu}$m for cavitation generation. And also, the vibratory cavitation erosion-corrosion tests on commercial mild steel SS41were carried out. We carefully observed the erosion pattern and surface photography. The geometrical mechanism of pit growth, which is to be likely these processing; shallow typelongrightarrowundercut typelongrightarrowwide shallow type.

  • PDF

A Study on Wear Characteristics of Machine Structural Steel by Surface Modification (표면개질에 의한 기계구조용강의 마멸특성에 관한 연구)

  • Park Heung-Sik;Woo Kyu-Sung
    • Tribology and Lubricants
    • /
    • v.22 no.2
    • /
    • pp.73-78
    • /
    • 2006
  • The surface modification of automobile parts is of great technological importance for the improvement of corrosion resistance, wear resistance, fatigue strength and so on. Recently, research on the development of the technology of surface modification substituting 6-balance chrome process has progressively been achieved in automobile parts. Although the innovation technology for the improvement of the corrosion-resisting and wear resistant properties through post oxidation after nitrocarburising process had attracted a great attention. For this, anodically potentiodynamic polarisation testing was carried out to corrosion resistance and friction and wear experiment according to applied load and sliding distance was carried out to evaluate the wear resistance of machine structural steel with nitrocarburising and non-nitrocarburising SM45C. The presumed wear volume was calculated with the image processing far evaluation of wear resistance of two materials. The results show that the nitrocarburising had a distinguished corrosion resistance and wear resistance than non-nitrocarburising.

Effects of Sr Additions on Microstructures and Mechanical Properties in Al-10%Si-0.3%Mg Alloy (Al-10%Si-0.3%Mg 합금에서 Sr첨가가 미세조직 및 기계적 성질에 미치는 영향)

  • Kim, Kyung-Hyun;Lee, Jung-Moo;Jung, Shin-Kum
    • Journal of Korea Foundry Society
    • /
    • v.13 no.1
    • /
    • pp.94-101
    • /
    • 1993
  • The effects of strontium content as modifier on microstructure and mechanical properties were studied in Al-10%Si-0.3%Mg cast alloys. There were not big differences in the form of eutectic Si particle and its morphology depending on adding amount of strontium, but the alloy modified by 0.012%Sr had shown the higher values than the alloy modified 0.038%Sr in strength, elongation and impact value.

  • PDF