• Title/Summary/Keyword: Corrosion prevention.

Search Result 155, Processing Time 0.03 seconds

Prevention of Soil Contamination from Underground Storage Facilities (유류저장시설로 인한 토양오염 예방대책)

  • 배우근;홍종철;정진욱;강우재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.169-173
    • /
    • 1998
  • The practice of the construction and management of the underground petroleum storage facilities in Korea was investigated extensively, and the problems were identified. The advanced technologies in the U.S.A was comparatively studied. Considering the effectiveness of leak prevention and technology applicability, the following measures were suggested. To prevent corrosion of the tank, a clad tank, an interior-lining tank, or a double-wall tank was appropriate and appeared to be most cost effective. For piping, non-metalic material was suggested. To prevent spill, a catchment basin can be effective. For monitoring of leak, construction of more than one of one or combination of an automatic leak-detection device, a vapor-detection system, a ground water-monitoring system, and a double-wall detection system was recommended.

  • PDF

Risk Assessment Using RBI for Internal Corroded Pipelines in CDU Desulfurization Process (CDU 내 탈황공정의 내부부식 된 파이프라인을 대상으로 한 RBI기법을 이용한 위험성 평가)

  • Lim, Donghui;Jeong, Taehun;Lee, In-Dong;Jung, In Hee;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.3
    • /
    • pp.33-39
    • /
    • 2019
  • in 2010s, many factories are operating without any safety guarantees due to the aging process. Although it is difficult to fundamentally solve the problem of aging process and equipment, Prevent risk by risk assessment in advance. This study targets the corrosion caused by sulfur in the piping in the CDU(Crude Distillation Unit) process desulfurization equipment and conducts the risk assessment by RBI(Risk Based Inspection) referring to API RP 581. RBI expresses the risk by combining frequency and consequence, and creates a risk matrix based on these expression. In this study, the hole size of the pipe was selected as Small and Medium, and the sensitivity of the frequency was selected as 'Low'. You can refer to the Risk Matrix created from the standard to evaluate the risk of corrosion of sulfur from pipes in the piping and to plan future accident prevention. Similarly, prevention of aging in a similar way can prevent large and small incidents that are not visible.

Buffer Intensity of Ammonia and MPA in Water-Steam Cycle of PWRs (가압경수로 원전 물-증기 순환영역에서 암모니아와 MPA의 완충세기)

  • Rhee, In-H.;Ahn, Hyun-Kyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2708-2712
    • /
    • 2010
  • Amines, ammonia or 3-methoxypropylamine (MPA), are used to maintain the optimized pH for the prevention of corrosion in the secondary side of Pressurized Water Reactors (PWRs). They are differently dissociated as a function of temperature which is not same in each location of the water-steam cycle. pH at the operation temperature depends on temperature of fluid and equilibrium constants of water and amines. Thus, every amine provides the different pH in the entire secondary side so that pH is not only the sufficient parameter in corrosion control. The secondary parameter, i.e., buffer intensity, is the ability to maintain a stable pH when $H^+$ are added or removed due to the ingress of impurities or the reaction of corrosion. The buffer intensity is necessary to provide the selection criteria for the best pH control agent for secondary side and the basic understanding of the reason why the flow-accelerated corrosion(FAC) rate may demonstrate the bell-shape curve over temperature. The buffer intensities of ammonia and MPA were reviewed over the entire operation temperature of PWRs. The sufficient buffer intensity is provided for the inhibition of corrosion by ammonia in low temperature $(25{\sim}100^{\circ}C)$ and by DMA in high temperature $(150{\sim}250^{\circ}C)$. In terms of buffer intensity, i) the best pH control agent is an amine with $pK_a(T)$ range of pH(T)- $1{\leq}pK_a(T){\leq}pH(T)$ + 0.5 and ii) the amine solution should have sufficient buffer intensity, ${\beta}$ to inhibit corrosion, and iii) FAC rate may be maximum at the temperature, where ${\beta}_B/{\beta}$ ratio is lowest.

Real time Wireless Remote Monitoring System for Stray Current of Subway System (지하철 누설전류 모니터링용 실시간 무선 원격 감시 시스템)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Lee, Jae-Duck;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2729-2731
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. In this paper, results of development about Real-time Wireless Remote Monitoring System for Stray Current of Subway System are presented.

  • PDF

The Buried Type Reference Electrode for Real time Wireless Remote Monitoring System for Stray Current of Subway System (지하철 누설전류의 실시간 무선 원격 감시 시스템용 매설형 기준전극)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Lee, Jae-Duck;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2732-2734
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. So, we have developed the Real-time Wireless Remote Monitoring System for Stray Current of Subway System. In this system, the permanent buried type reference electrode is necessary. In this paper, results of development about the permanent buried type reference electrode($Cu/CuSO_4$) are presented.

  • PDF

The Development of Buried Type Reference Electrode Using Porous Ceramic(${\alpha}-Al_{2}O_{3}$) (다공성 세라믹(${\alpha}-Al_{2}O_{3}$)를 이용한 지중 매설형 기준전극)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.145-147
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. So, we have developed the Real-time Wireless Remote Monitoring System for Stray Current of Subway System. In this system, the permanent buried type reference electrode is necessary. In this paper, results of development of buried type reference electrode using porous ceramic$({\alpha}-Al_{2}O_{3})$ are presented.

  • PDF

Ultrasonics and electromagnetics for a wireless corrosion sensing system embedded in structural concrete

  • Hietpas, K.;Ervin, B.;Banasiak, J.;Pointer, D.;Kuchma, D.A.;Reis, H.;Bernhard, J.T.
    • Smart Structures and Systems
    • /
    • v.1 no.3
    • /
    • pp.267-282
    • /
    • 2005
  • This work describes ongoing development of an embedded sensor system for the early detection and prevention of deterioration of reinforcing steel tendons within reinforced concrete. These devices will evaluate the condition of the steel tendon using ultrasonic techniques and then wirelessly transmit this data to the outside world without human intervention. The ultrasonic transducers and the interpretation of the sensed signals that allow detection and prognosis of tendon condition are detailed. Electrical characterization of concrete mixtures used in bridge construction is conducted and a wideband microstrip antenna is designed and fabricated to operate between 2.4 and 2.5 GHz when embedded in such a medium. Simulations and measurements of the embedded antenna element are presented. Transceiver selection and implementation are discussed as well as future work in operational protocols, sensor networking, and power sources. By implementing commercially available off-the-shelf components whenever possible, these devices have the potential to save millions of dollars a year in evaluation, repair and replacement of reinforced concrete.

Determination of the repair grout volume to fill voids in external post-tensioned tendons

  • Im, Seok Been;Hurlebaus, Stefan
    • Structural Engineering and Mechanics
    • /
    • v.42 no.1
    • /
    • pp.25-38
    • /
    • 2012
  • Recently, investigated failures of external post-tensioned (PT) tendons have called attention to the corrosion of strands in PT bridges, and the prevention of ongoing corrosion is required to secure their structural integrity. Since voids inside ducts can be a source for the ingress of water or deleterious chemicals, the vacuum grouting (VG) method and a volumeter for estimating amount of repair grouts were employed to fill voided ducts. However, the VG method is expensive and time-consuming for infield application because it requires an air-tight condition of entire ducts. Thus, latest research assessed three different repair grouting methods, and the pressure vacuum grouting (PVG) method was recommended in the field because it showed good filling capability in voided ducts and did not require an air-tight condition. Thus, a new method is required to estimate the volume of repair grouts because the PVG method is not applied in air-tight ducts. This research assesses the relationship between voided areas on ducts identified with soundings and required grout volume for repair using experimental results. The results show that the proposed equations and assumptions for estimating repair grout volume provide a sufficient amount of repair grouts for filling voided ducts.

Shell Wall Thinning and Mitigation Plan and Design Modification of a Feedwater Heater Impingement Baffle (급수가열기 동체 감육 현상과 완화 방안 및 충격판 설계개선)

  • Kim, Kyung-Hoon;Hwang, Kyeong-Mo;Park, Sang-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.6
    • /
    • pp.55-63
    • /
    • 2010
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damage, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle inside feedwater heater installed downstream of the turbine extraction stream line. At that point, the extract steam from the turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows to reverse direction after impinging the impingement baffle, the shell wall of feedwater heaters may be affected by flow-accelerated corrosion. In this paper, to compare degree of shell wall thinning mitigation rate to squared type with mitigation rate of other type baffle plate, three different types of impingement baffle plate-squared, curved and mitigating type-applied inside the shell. With these comparison data, this paper describes operation of experiments and numerical analysis which is composed similar condition with real feed water heater. And flow visualization is operated for verification of experiments and numerical analysis. In conclusion, this study shows that mitigating type baffle plate is more effective than other baffle plate about prevention of pressure concentration and pressure value decrease.

A Study on the Performance Development of Sewage Concrete by Application of Antibiotics (항균제 도포에 의한 하수시설 콘크리트의 성능향상에 관한 연구)

  • Kim, Moo-Han;Kim, Gyu-Yong;Khil, Bae-Su;Cho, Bong-Suk;Lee, Eui-Bae
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.371-378
    • /
    • 2006
  • Recently sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. In this study, to prevent biochemical corrosion of the sewer concrete, antibiotics which prevent growth of sulfur-oxidizing bacteria were developed and antimicrobial performance of it was investigated. After that, to consider applicability of antibiotics to concrete, physical properties of concrete covered with antibiotics were investigated. As a results of the study, it was proved that the antimicrobial performance of antibiotics was available. Also compressive strength and bond strength of concrete didn't closely connected with antibiotics, and resistance to abrasion, water absorption, air permeability, carbonation, salt damage and chemical attack of concrete was improved remarkably by covering with it.