References
- Corven, J.A. (2001), Mid-Bay Bridge Post-tensioning Evaluation - Final Report, Florida Department of Transportation (FDOT), Corven Engineering Inc., Tallahassee, FL.
- FHWA (2004), Post-Tensioning Tendon Installation and Grouting Manual, Federal Highway Administration (FHWA), Washington, DC.
- Im, S.B., Hurlebaus, S. and Trejo, D. (2010a), "Effective repair grouting methods and materials for filling voids in external post-tensioned tendons", Transport. Res. Record: J. Tran. Res. Board, 2172, 3-10. https://doi.org/10.3141/2172-01
- Im, S.B., Hurlebaus, S. and Trejo, D. (2010b), "Inspection of voids in external tendons of post-tensioned bridges", Transport. Res. Record: J. Tran. Res. Board, 2172, 115-122. https://doi.org/10.3141/2172-13
- O'Neil, E.F. and Schupack, M. (1997), "Steel post-tensioning tendon behavior - up to 35-year marine exposure", Proceedings of ASCE Structures Congress, 324-328.
- Park, R. (1975), "Post-tensioned tendons in prestressed concrete - to grout or not to grout?", New Zealand Eng., 30(11), 315-319.
- PCI (1997), Chapter 3: Fabrication and Construction, PCI Bridge Design Manual, Prestressed Concrete Institute, Chicago, IL.
- Pearson-Kirk, D. (2003), "The performance of post-tensioned bridge", Role of Concrete Bridges in Sustainable Development - Proceedings of the International Symposium, 129-140.
- Pielstick, B. (2002), "Grouting of segmental posttensioned bridges in America", Transport. Res. Record, 1813, 235-241. https://doi.org/10.3141/1813-28
- Pillai, R.G. (2009), "Electrochemical characterization and time-variant structural reliability assessment of posttensioned, segmental concrete bridges", Ph.D Dissertation, Texas A&M University, College Station, TX.
- Raiss, M. (1995), "Post-tensioned concrete bridges: the UK debate", Concrete Int., 29(2), 23-26.
- Schokker, A.J., Breen, J.E., and Kreger, M.E. (2001), "Grouts for bonded post-tensioning in corrosive environments", ACI Mate. J., 98(4), 296-305.
- Shoji, N., Noritaka, S., Yasushi, K. and Koichiro, S. (2003), "Development of repair method for poorly grouting of PC structures", Concrete J., 41(11), 31-43. https://doi.org/10.3151/coj1975.41.11_31
- Sprinkel, M. and Napier, C.S. (2008), "VDOT experience with grouted tendons in Varina-Enon precast segmental post-tensioned bridge", Virginia Concrete Conference.
- Trejo, D., Hueste, M.B., Gardoni, P., Pillai, R., Reinschmidt, K., Im, S.B., Kataria, S., Hurlebaus, S., Gamble, M. and Ngo, T. (2009a), Effect of Voids in Grouted Post-tensioned Concrete Bridge Construction, Vol. 2, Texas Department of Transportation (TxDOT), Austin, TX.
- Trejo, D., Im, S.B., Pillai, R., Hueste, M.B., Gardoni, P., Hurlebaus, S. and Gamble, M. (2009b), Effect of Voids in Grouted Post-Tensioned Concrete Bridge Construction: Inspection and Repair Manual for External Tendons in Post-tensioned Bridges, Texas Department of Transportation (TxDOT), Austin, TX.
- TxDOT (2004), Critical Evaluation and Condition Assessment of Post-Tensioned Bridges in Texas, Texas Department of Transportation (TxDOT), Austin, TX.
- VSL (2002), Grouting of Post - Tensioning Tendons. Report Series 5, VSL International Ltd., Lyssach, Switzerland.
- Woodward, R.J. and Miller, E. (1990), "Grouting post-tensioned concrete bridges: the prevention of voids", Highw. Transport., 37(6), 9-17.
Cited by
- Electromagnetic characterization of grouting materials of bridge post tensioned ducts for NDT using capacitive probe vol.60, 2013, https://doi.org/10.1016/j.ndteint.2013.07.010
- Filtration-induced pressure evolution in permeation grouting vol.75, pp.5, 2012, https://doi.org/10.12989/sem.2020.75.5.571