• Title/Summary/Keyword: Corrosion measurement

Search Result 432, Processing Time 0.021 seconds

Probing of Steel Bar Location inside Concrete using Multi-electrode Array (다전극 배열을 이용한 콘크리트 매립 철근의 위치탐사)

  • 이형우;임홍철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.663-666
    • /
    • 2003
  • Using numerical analysis modeling of Multi-electrode Array that could be applied to the corrosion state measurement of a reinforcing steel bar in concrete, the steel bar location inside concrete can be probed by the investigation of the change of the measured impedance from concrete surface determined by the electrical impedance of interface between the steel bar and concrete, the electrical resistivity of concrete, the array of electrodes and the relative location and diameter of the steel bar.

  • PDF

Deformation of the Tubes in Copper/Brass Radiator with Rise of Temperature and Pressure (온도 및 압력상승에 따른 동/황동 라디에터 튜브의 변형)

  • 정명진
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.4
    • /
    • pp.16-20
    • /
    • 1993
  • The combined effect of increased pressure/temperature and the reduced material thicknesses act to increase the stress on the radiator componets. The design life of the radiator is influenced by the cyclic stresses and corrosion, which act to weaken the materials, radiator mechanical failure occurs when a tube or solder Joint ruptures, causing coolant loss or insufficient heat rejection. Therefore, in this study, through strain measurement of the tubes in copper/brass radiator, the strain distribution of the tubes in radiator as function of temperature and pressure is obtained.

  • PDF

Characteristics of OCP of Reinforced Concrete Using Socket-type Electrodes during Periodic Salt Damage Test (주기적 염해 시험에 따른 소켓 타입 전극을 활용한 철근 콘크리트의 OCP 특성)

  • Lee, Sang-Seok;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.28-36
    • /
    • 2021
  • It is known that buried rebars inside concrete structures are protected from corrosion due to passive layer. It is very important to delay the timing of corrosion or evaluate a detection of corrosion initiation for the purpose of cost-beneficiary service life of a structure. In this study, corrosion monitoring was performed on concrete specimens considering 3 levels of cover depth(60 mm, 45 mm, and 30 mm), W/C(water to cement) ratio(40.0%, 50.0%, and 60.0%) and chloride concentration(0.0%, 3.5%, and 7.0%). OCP(Open Circuit Potential) was measured using agar-based socket type sensors. The OCP measurement showed the consistent behavior where the potential was reduced in wet conditions and it was partially recovered in dry conditions. In the case of 30 mm of cover depth for most W/C ratio cases, the lowest OCP value was measured and rapid OCP recovery was evaluated in increasing cover depth from 30 mm to 45 mm, since cover depth was an effective protection against chloride ion ingress. As the chloride concentration increased, the effect on the cover depth tended to be more dominant than the that of W/C ratio. After additional monitoring and physical evaluation of chloride concentration after specimen dismantling, the proposed system can be improved with increasing reliability of the corrosion monitoring.

Investigation on the Studies for Welding Residual Stresses in Nuclear Components (원전 기기 용접 잔류응력 평가 연구 고찰)

  • Kim, Jong Sung
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.30-40
    • /
    • 2016
  • The paper investigates the previous studies about welding residual stresses in nuclear components. First, various residual stress measurement methods are reviewed in applicability. Second a finite element welding residual stress analysis technique, which was developed from the viewpoint of FFS (Fitness-For-Service) assessment, is explained. Third, characteristics of the welding residual stresses on J-groove welds and butt welds were presented via investigating the previous studies. Last, engineering formulae for residual stresses in the FFS assessment codes such as R6 and API 579/ASME FFS-1 Code is summarized.

Experimental Study on the Effect of Specimen Size on Electrical Resistivity Measurement (전기비저항 측정에서 실험체 크기의 영향에 대한 실험적 연구)

  • Lim, Young-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.164-169
    • /
    • 2018
  • In this study, the effect of the size of the specimen on the apparent resistivity was investigated at the laboratory level for electrical resistivity. The specimens were measured for apparent resistivity by fabricating specimens with different sides and heights. Experimental results show that the apparent resistivity increases as the side and height of the specimen become smaller. Also, it was confirmed that the influence of the size of the specimen on the electrical resistivity measurement was not linear.

A Study on the Surface Properties Test of the Grinding Disk Assembly for Crushing Materials in Secondary Cells (이차전지 원료 해쇄용 그라인딩 디스크 어셈블리 표면 특성 시험에 관한 연구)

  • Sang-Pil Han;Dong-Hyuk Lee
    • Design & Manufacturing
    • /
    • v.17 no.2
    • /
    • pp.33-41
    • /
    • 2023
  • Metal raw materials and chemical additives, which are raw materials for secondary batteries, are pulverized by the high-speed rotation of the Grinding Disc of the Classifier Separator Mill (CSM). Grinding discs are required to withstand abrasion, corrosion, high-speed rotational force and impact. In order to analyze the stability of domestic and foreign grinding discs, quality tests including surface roughness, surface lubrication, surface state measurement, and surface 3D shape measurement were analyzed. When producing developed products, it shows that excellent products can be produced.

A study on Electronic Properties of Passive Film Formed on Ti

  • Kim, DongYung;Kwon, HyukSang
    • Corrosion Science and Technology
    • /
    • v.2 no.5
    • /
    • pp.212-218
    • /
    • 2003
  • Electronic properties of passive films formed on Ti at film formation potentials $(E_f)V_{SCE}$ in pH 8.5 buffer solution and in an artificial seawater were examined through the photocurrent measurement and Mott-Schottky analysis. The passive films formed on Ti in pH 8.5 buffer solution exhibited a n-type semiconductor with a band gap energys $(E_g);E_g^{n=2}=3.4$ eV for nondirect electron transition, and $E_g^{n=0.5}=3.7$ eV for direct electron transition. These band gap values were almost same as those for the passive films formed in artificial seawater, indicating that chloride ion ($Cl^-$ in solution did not affect the electronic structure of the passive film on Ti. $E_g$ for passive films formed on Ti were found to be greater than those ($E_g^{n=0.5}=3.1$ eV, $E_g^{n=2}=3.4$) for a thermal oxide film formed on Ti in air at $400^{\circ}C$. The disorder energy of passive film, determined from the absorption tail of photocurrent spectrum, was much greater than that for the thermal oxide film farmed on Ti in air at $400^{\circ}C$. The greater $E_g$ and the higher disorder energy for the passive film compared with those for the thermal oxide fIlm suggest that the passive film on Ti exhibited more disorded structure than the thermal oxide film. The donor density (about $2.4{\times}10^{20}cm^{-3}$) for the passive film formed in artificial seawater was greater than that (about $20{\times}10^{20}cm^{-3}$) formed in pH 8.5 buffer solution, indicating that $Cl^-$ increased the donor density for the passive film on Ti.

Monitoring of Concrete Deterioration Caused by Steel Corrosion using Electrochemical Impedance Spectroscopy(EIS) (EIS를 활용한 철근 부식에 따른 콘크리트 손상 모니터링)

  • Woo, Seong-Yeop;Kim, Je-Kyoung;Yee, Jurng-Jae;Kee, Seong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.651-662
    • /
    • 2022
  • The electrochemical impedance spectroscopy(EIS) method was used to evaluate the concrete deterioration process related to chloride-induced steel corrosion with various corrosion levels(initiation, rust propagation and acceleration periods). The impressed current technique, with four total current levels of 0C, 13C, 65C and 130C, was used to accelerate steel corrosion in concrete cylinder samples with w/c ratio of 0.4, 0.5, and 0.6, immersed in a 0.5M NaCl solution. A series of EIS measurements was performed to monitor concrete deterioration during the accelerated corrosion test in this study. Some critical parameters of the equivalent circuit were obtained through the EIS analysis. It was observed that the charge transfer resistance(Rc) dropped sharply as the impressed current increased from 0C to 13C, indicating a value of approximately 10kΩcm2. However, the sensitivity of Rc significantly decreased when the impressed current was further increased from 13C to 130C after corrosion of steel had been initiated. Meanwhile, the double-layer capacitance value(Cdl) linearly increased from 50×10-6μF/cm2 to 250×10-6μF/cm2 as the impressed current in creased from 0C to 130C. The results in this study showed that monitoring Cdl is an effective measurement parameter for evaluating the progress of internal concrete damages(de-bonding between steel and concrete, micro-cracks, and surface-breaking cracks) induced by steel corrosion. The findings of this study provide a fundamental basis for developing an embedded sensor and signal interpretation method for monitoring concrete deterioration due to steel corrosion at various corrosion levels.

Analysis of Error Rate in the Variations of Shearing Amount in Measuring the Internal Defect using a Shearography (전단간섭계를 이용한 압력용기 내부 결함 측정시 전단량 변화에 따른 오차분석)

  • Hong, Kyung-Min;Kang, Young-June;Choi, In-Young;Ahn, Yong-Jin;Yoon, Suk-Bum
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.726-732
    • /
    • 2012
  • Pipe and Pressure Vessels that is used in power plant and chemical industry have many Internal Defects that is corrosion caused by the flow of fluid. These Internal Defects that have possibility of explosion are very dangerous because it can not see from the outside. This days many companys using NDT method to find an Internal Defect. Most of the NDT methods have limitations that are constraint of shape and materials. But Sheargoraphy have many advantages compared conventional NDT method. It has very fast measuring speed, non-destructive and non contacting measurement. As well as it hasn't constraint of shape and materials. As a paper on the analysis of measurement of error, the important factors were the Shearing Amount and pressure, and discovered measurement of the Internal Defect of the object by using shearography. The optimal Shearing Amount and pressure was discovered and utilized.

Construction of the Electrochemical Impedance Measurement System Using Fourier Transform (푸리에 변환을 이용한 전기화학적 임피던스 측정 시스템 제작)

  • Hwang, Eui-Jin;Oh, Sang-Hyub
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.713-719
    • /
    • 1991
  • Electrochemical impedance measurement system using Fourier transform was constructed in the range of the frequencies up to 100 kHz. This system consists of pseudo-random noise generator, specially designed potentiostat, fast data acquisition system, system controller, and computer interface. The performance of the constructed system was found to be almost same as the commercially available system using lock-in amplifier. Measuring time was significantly reduced because the minimum time for the measurement depended on one cycle of the lowest frequency used. It would be possible to study time-varying electrochemical impedance systems such as the initial stages of corrosion processes using this system.

  • PDF