• 제목/요약/키워드: Correlated Flow

검색결과 503건 처리시간 0.029초

The investigation of combined ventilation-biofilter systems using recycled treated wastewater on odor reduction efficiency

  • Febrisiantosa, Andi;Choi, Hong L.;Renggaman, Anriansyah;Sudiarto, Sartika I.A.;Lee, Joonhee
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권7호
    • /
    • pp.1209-1216
    • /
    • 2020
  • Objective: The present study aimed to evaluate the performance of odor abatement by using two different ventilation-biofilter systems with recycled stablized swine wastewater. Methods: The performance of odor removal efficiency was evaluated using two different ventilation-biofilter-recycled wastewater arrangements. A recirculating air-flow ventilation system connected to a vertical biofilter (M1) and a plug-flow ventilation system connected to a horizontal biofilter (M2) were installed. Water dripping over the surface of the biofilter was recycled at a flow rate of 0.83 L/h in summer and 0.58 L/h in winter to reduce odorous compounds and particulate matter (PM). The experiments were performed for 64 days with M1 and M2 to investigate how these two ventilation-biofilter systems influenced the reduction of odor compounds in the model houses. Odorous compounds, NH3 and volatile organic compounds (VOCs) were analyzed, and microclimatic variables such as temperature, humidity, and PM were monitored. Results: Ammonia concentration inside M1 was about 41% higher on average than that in M2. PM and total suspended particles (TSPs) inside M1 were about 62.2% and 69.9%, respectively, higher than those in M2. TSPs in the model house were positively correlated with the concentration of NH3 and VOCs. Conclusion: M2 emitted lower concentration of odorous compounds than M1. Moreover, M2 could maintain the optimum temperature condition for a swine house during the cooler season. The plug-flow ventilation-horizontal biofilter system could be used for pig houses to minimize air pollution produced by swine farming activities and maintain optimum microclimate conditions for pigs.

100MPa급 이상의 초고강도 콘크리트의 특성에 관한 연구 - 유동성 및 rheology 특성 (A study on properties of ultra high strength concrete of above 100MPa - fluidity and rheology properties)

  • 서일;이진우;박희곤;배연기;조성현;이한승
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.317-320
    • /
    • 2008
  • 본 연구는 최근 건축물의 대형화 다양화 되어감에 따라 초고강도 콘크리트에 대한 높은 관심과 연구가 활발하게 이루어지고 있는 상황에서 국내에서도 200MP급 이상의 초고강도 콘크리트가 개발 되었고, 150MPa의 초고강도 콘크리트의 실용화 연구가 진행되고 있는 상황이다. 하지만, 100MPa급 이상의 초고강도 콘크리트는 물-결합재비가 낮기 때문에 점성이 높아 기존의 슬럼프 실험만으로는 유동성을 평가하기에는 부족하기 때문에 레올로지(rheology)를 이용한 평가와 O-lot, V-funnel 실험 평가를 하여 상관 관계를 밝힘으로써 100MPa급 이상의 초고강도 콘크리트의 실용화를 위한 기본 정보를 제공하는데 그 목적을 두었다. 실험 결과, Yield stress과 slump flow, V-funnel는 높은 상관관계가 있음을 알 수 있었고, plastic viscosity도 O-lot시간과 V-funnel시간과 높은 상관관계가 있음을 알 수 있었다.

  • PDF

관상동맥의 기하학적 형상변화에 따른 동맥경화 위험도 (Atherogenic Risk Stratification According to Changes in the Geometrical Shape of the Coronary Artery)

  • 서상호;박준길;노형운;이병권;권혁문
    • 대한기계학회논문집B
    • /
    • 제34권10호
    • /
    • pp.893-899
    • /
    • 2010
  • 박동유동조건에서 관상동맥 내의 유동특성과 혈류역학적 인자 분포를 선행연구에서 수행하여 혈류역학이 관상동맥 내의 협착현상과 연관관계가 있음을 밝혔다. 동맥경화증의 호발부위인 관상동맥 분지부에서 혈류역학적 변수를 분석하여 동맥경화증의 발생기전을 규명하는 것이 본 연구의 목적이다. 동맥경화증에 의한 협착현상은 혈액과 혈관벽 사이의 생화학 반응뿐 아니라 유동박리나 벽전단응력과 같은 혈류역학적 인자와도 관계 있음을 확인하였다. 관상동맥 분지부의 분지각이 증가할수록 분지부 단면에서의 재순환영역의 크기가 증가하고 교란유동이 발생하게 된다. 이 재순환영역이 관상동맥에서 동맥경화의 시작점으로 의심되는 영역이라 할 수 있다.

무마취 가토 신장기능에 미치는 Atrial Natriuretic Factor의 영향 (Effect of Atrial Natriuretic Factor on the Renal Function and Renin Release in Unanesthetized Rabbit)

  • 이준규;조경우
    • The Korean Journal of Physiology
    • /
    • 제20권1호
    • /
    • pp.103-124
    • /
    • 1986
  • Since it has been suggested that atrial receptor may be involved in the mechanism of extracellular volume regulation, it was shown that the granularity of atrial cardiocytes can be changed by water and salt depletion, and that an extract of cardiac atrial tissue, when injected intravenously into anesthetized rats, was shown to cause a large and rapid increase in renal excretion of sodium. Various natriuretic peptides were isolated and synthetized, and the effects were investigated by many workers. Most studies, however, have been carried out under anesthesia and there have teen some controversies over direct effect of the factor on the renal function. Therefore, it was attempted in this study to access the effects of an atrial extract and a synthetic natriuretic factor in unanesthetized rabbits. Intrarenal arterial infusion of atrial extract caused a rapid increase of urinary volume and excretion of sodium. Glomerular filtration rate and renal plasma flow were both increased with no change in filtration fraction. The ventricular extract produced no change in urinary excretion of electrolytes, nor in renal hemodynamics. Intrarenal infusion of synthetic atrial natriuretic factor caused increases of renal excretory rate of sodium, chloride and potassium, and $FE_{Na}$. Glomerular filtration rate, renal plasma flow increased. And free water clearance also increased. Accentuated excretory function correlated well with increased glomerular filtration rate and renal plasma flow during infusion and for 10 minutes following the cessation of the infusion. Renin secretion rate decreased during constant infusion of atrial natriuretic factor. However, no correlation was found with the changes in glomerular filtration rate, renal plasma flow, or urinary excretion of sodium. These results suggest that atrial extract or atrial natriuretic factor induces changes in renal hemodynamics, as in excretion of electrolytes either indirectly through hemodynamic changes or directly by inhibiting tubular reabsorption. At the same time, renin secretory function is affected by the factor possibly through an unknown mechanism.

  • PDF

비대면 원격 수업에서 간호대학생의 학업성취도에 영향을 미치는 요인 (Factors Affecting Academic Achievement of Nursing Students in Non-face-to-face Distance Learning)

  • 박순아;이승민
    • 문화기술의 융합
    • /
    • 제8권5호
    • /
    • pp.111-119
    • /
    • 2022
  • 연구의 목적은 비대면 원격 수업에서 간호대학생의 자기주도학습능력, 교수실재감, 학습몰입, 학업성취도 간의 상관관계를 파악하고, 학업 성취도에 영향을 미치는 요인들을 규명하기 위함이다. 2021년 6월 1일부터 6월 20일까지G시에 위치한 일 개 대학 간호대학생 150명을 편의표집 하였으며, 부적절한 응답자를 제외한 146명의 자가보고 설문지를 SPSS/WIN 23.0 프로그램을 이용하여 분석하였다. 본 연구결과 지각된 학업 성취도는 자기주도학습능력, 교수실재감. 학습몰입과 유의한 정적 상관관계를 보였다. 회귀분석 결과 학습몰입, 자기 주도 학습능력과 교수실재감은 학업성취도에 대해 67.0%의 설명력을 보였다. 따라서 본 연구를 토대로 비대면 수업에서 간호대학생의 자기주도학습능력, 교수실재감, 학습몰입을 함께 향상 시킬 수 있는 수업설계와 맞춤형 교육방법을 적용한다면 학업성취도 향상에 더 효과적일 것이다.

신동맥내 투여한 Angiotensin II가 신장기능 및 Renin 분비에 미치는 영향 (Effect of Unilateral Renal Arterial Infusion of Angiotensin II on Renal Function and Renin Secretion in Unanesthetized Rabbit)

  • 김종훈;강남부;김영진;김선희;조경우
    • The Korean Journal of Physiology
    • /
    • 제23권2호
    • /
    • pp.363-375
    • /
    • 1989
  • It has been well known that peripheral infusion of angiotensin II results in an increase of blood pressure, and an elevation of aldosterone secretion, and an inhibition of renin relase. However, the direct effect of angiotensin II on renal function has not been clearly established. In the present study, to investigate the effect of angiotensin II on renal function and renin release, angiotensin II (0.3, 3 and 10 ng/kg/min) was infused into a unilateral renal artery of the unanesthetized rabbit and changes in renal function and active and inactive renin secretion rate (ARSR, IRSR) were measured. In addition, to determine the relationship between the renal effect of angiotensin II and adenosine, the angiotensin II effect was evaluated in the presence of simultaneously infused 8-phenyltheophylline (8-PT, 30 nmole/min), adenosine A 1 receptor antagonist. Angiotensin II infusion at dose less than 10 ng/kg/min decreased urine flow, clearances of para-amino-hippuric acid and creatinine, and urinary excretion of electrolytes in dose-dependent manner. The changes in urine flow and sodium excretion were significantly correlated with the change in renal hemodynamics. Infusion of angiotensin II at 10 ng/kg/min also decreased ARSR, but it has no significant effect on IRSR. The change in ARSR was inversely correlated with the change in IRSR. The plasma concentration of catecholamine was not altered by an intarenal infusion of angiotensin II. In the presence of 8-PT in the infusate, the effect of angiotensin II on renal function was significantly attenuated, but that on renin secretion was not modified. These results suggest that the reduction in urine flow and Na excretion during intrarenal infusion of angiotensin II was not due to direct inhibitions of renal tubular transport systems, but to alterations of renal hemodynamics which may partly be mediated by the adenosine receptor.

  • PDF

Myocardial Blood Flow Quantified by Low-Dose Dynamic CT Myocardial Perfusion Imaging Is Associated with Peak Troponin Level and Impaired Left Ventricle Function in Patients with ST-Elevated Myocardial Infarction

  • Jingwei Pan;Mingyuan Yuan;Mengmeng Yu;Yajie Gao;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.709-718
    • /
    • 2019
  • Objective: To investigate the association of myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) with troponin level and left ventricle (LV) function in patients with ST-segment elevated myocardial infarction (STEMI). Materials and Methods: Thirty-five STEMI patients who successfully had undergone reperfusion treatment within 1 week of their infarction were consecutively enrolled. All patients were referred for dynamic CT-MPI. Serial high-sensitivity troponin T (hs-TnT) levels and left ventricular ejection fraction (LVEF) measured by echocardiography were recorded. Twenty-six patients with 427 segments were included for analysis. Various quantitative parameters derived from dynamic CT-MPI were analyzed to determine if there was a correlation between hs-TnT levels and LVEF on admission and again at the 6-month mark. Results: The mean radiation dose for dynamic CT-MPI was 3.2 ± 1.1 mSv. Infarcted territories had significantly lower MBF (30.5 ± 7.4 mL/min/100 mL versus 73.4 ± 8.1 mL/min/100 mL, p < 0.001) and myocardial blood volume (MBV) (2.8 ± 0.9 mL/100 mL versus 4.2 ± 1.1 mL/100 mL, p = 0.044) compared with those of reference territories. MBF showed the best correlation with the level of peak hs-TnT (r = -0.682, p < 0.001), and MBV showed a moderate correlation with the level of peak hs-TnT (r = -0.437, p = 0.026); however, the other parameters did not show any significant correlation with hs-TnT levels. As for the association with LV function, only MBF was significantly correlated with LVEF at the time of admission (r = 0.469, p = 0.016) and at 6 months (r = 0.585, p = 0.001). Conclusion: MBF quantified by dynamic CT-MPI is significantly inversely correlated with the level of peak hs-TnT. In addition, patients with lower MBF tended to have impaired LV function at the time of their admission and at 6 months.

여러 가지 교반조에서 Paddle 임펠러의 교반소요동력 특성 (Characteristic of Power Consumption for Paddle Impeller in Various Agitated Vessels)

  • 이영세
    • 공업화학
    • /
    • 제16권5호
    • /
    • pp.698-704
    • /
    • 2005
  • 구형교반조 및 원통교반조에서 paddle 임펠러의 교반소요동력을 넓은 범위의 레이놀즈수 영역에서 측정하였다. 구형교반조는 교반조 높이가 직경과 같고, 구형교반조의 체적과 같은 원통교반조의 겉보기 직경을 이용하여 구형교반조 및 원통교반조 모두에 적용할 수 있는 교반소요동력 상관식을 구했다. 이 상관식은 Nagata 등 및 Hixson 등의 실험결과에도 양호하게 상관되었다. 또한 임계레이놀즈수는 본 상관식에서 얻은 층류영역에서 난류영역으로의 전이에 관한 계수 $C_{tr}$에 잘 상관되었다.

오염총량관리제도의 TOC 목표수질 설정 방안 (Establishment of Target Water Quality for TOC of Total Water Load Management System)

  • 김용삼;이은정
    • 한국물환경학회지
    • /
    • 제35권6호
    • /
    • pp.520-538
    • /
    • 2019
  • In this study, it was proposed that a method of setting the target water quality for TOC using the watershed model and the load duration curves to manage non-biodegradable organics in the total water load management system. To simulate runoff and water quality of the watershed, the HSPF model is used which is appropriate for urban and rural areas. Additionally, the load duration curve is used to reflect the variable water quality correlated with various river flow rates in preparing the TMDL plans in the U.S. First, the model was constructed by inputting the loads calculated from the pollutant sources in 2015. After the calibration and verification process, the water quality by flow conditions was analyzed from the BOD and TOC simulation results. When the BOD achieved the target water quality by inputting the target year loads for 2020, the median and average values of TOC were proposed for the target water quality. The provisional method of TOC target water quality for the management of non-biodegradable organics, which is one of the challenges of the total water load management system, was considered. In the future, it is expected to be used as basic data for the conversion of BOD into TOC in the total water load management system.

전열면적 및 유체의 종류가 핵비등 열전달에 미치는 영향과 그 원인 (MECHANISM OF NUCLEATE BOILING HEAT TRANSFER FROM WIRES IMMERSED IN SATURATED FC-72 AND WATER)

  • 김주한;유승문;박종연
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.232-239
    • /
    • 2001
  • The present study is an experimental investigation of nucleate boiling heat transfer mechanism in pool boiling from wire heaters immersed in saturated FC-72 coolant and water. The vapor volume flow rate departing from a wire during nucleate boiling was determined by measuring the volume of bubbles, varying $25{\mu}m,\;75{\mu}m,\;and\;390{\mu}m$, from a wire utilizing the consecutive-photo method. The effects of the wire size on heat transfer mechanism during a nucleate boiling were investigated by measuring vapor volume flow rate and the frequency of bubbles departing from a wire immersed in saturated FC-72. One wire diameter of $390{\mu}m$ was selected and tested in saturated water to investigate the fluid effect on the nucleate boiling heat transfer mechanism. Results of the study showed that an increase in nucleate boiling heat transfer coefficients with reductions in wire diameter was related to the decreased latent heat contribution. The latent heat contribution of boiling heat transfer for the water test was found to be higher than that of FC-72. The frequency of departing bubbles was correlated as a function of bubble diameters.

  • PDF