• Title/Summary/Keyword: Correction of small eye

Search Result 8, Processing Time 0.024 seconds

Neural network based distortion correction of wide angle lens (신경회로망을 이용한 광각렌즈의 왜곡보정)

  • 정규원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.299-301
    • /
    • 1996
  • Since a standard lens has small sight angle, a fish-eye lens can be used in order to obtain wide sight angle for the robot vision system. In spite of the advantage, the image through the lens has variable resolution; the central information of the lens is of high resolution, but the peripheral information is of low resolution. Owing to this difference of resolution, the variable resolution image should be transformed to a uniform resolution image in order to determine the positions of the objects in the image. In this work, the correction method for the distorted image is presented and the performance is analyzed. Furthermore, the camera with a fish eye lens can be used to determine the real world coordinates. The performance is shown through experiments.

  • PDF

Influence of Correction Makeup on physiognomic Images (수정 메이크업이 인상학적 이미지에 미치는 영향)

  • Lee, Kang-Mi;Kim, Ju-Seub
    • Journal of the Korean Society of Fashion and Beauty
    • /
    • v.4 no.1 s.7
    • /
    • pp.19-27
    • /
    • 2006
  • This study aims to analyze e potential and practical influences of physiognomic correction makeup that may change personal impression on faces, especially general physiognomy including eyebrow, cheek bones, lips. To meet this goal, this study looked into various literature materials on the basic concept and principles of physiognomy. With a series of photos showing 3 steps of makeup, i.e. a face before makeup, a face after general self-makeup and a face after makeup modified in physiognomic manner, a questionnaire survey was applied to the subjects. The results of survey can be outlined as follows It was found that physiognomic correction makeup could change various disadvantageous impressions into positive direction, impression of persons with thin eye brow looking like those with neither brightness nor deserving of any help from others, impression of persons with high cheek bones looking like the strong and masculine, impression of persons with small lips looking like the narrow-minded. Furthermore, physiognomic makeup changed positively changing the impression of persons with round chin looking like the ordinary than before.

  • PDF

Correction of Small Eye Opening with Combined Method (복합 안검 성형술을 이용한 작은 눈의 교정)

  • Joh, Se Heum;Lee, Han Earl;Lee, Hae Min
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.187-192
    • /
    • 2008
  • Purpose: Generally speaking, most of Korean have smaller eyes than those of Caucasian and they have epicanthus with narrow palpebral fissure. It makes external appearance looking dull because the length of the palpebral fissure is short and there is a epicanthus. In case the function of the levator muscle is weak, their eyes look much smaller. Epicanthus and weak levator muscle function make the eyes look dull. The above mentioned, authors want to introduce double eyelid operation, epicanthoplasty, levator plication to extend and lengthen the palpebral fissure. Methods: From August 2001 to August 2004, there were 138 cases that had double eyelid operation with epicanthoplasty or levator plication. the 69 cases of them had double eyelid operation and epicanthoplasty, the 33 cases of them had double eyelid operation and levator plication and the 36 cases of them had double eyelid operation and epicanthoplasty and levator plication. Results: After the operation, the length and height of the eyelid are improved remarkably, and most of the patients were satisfied. The length of the eyelid is improved 3 to 5mm($3.4{\pm}0.5mm$) in case of the epicanthoplasty, the width of the eyelid is improved 3 to 4mm($3.1{\pm}0.3mm$) by the levator plication. The length of the eyelid is improved 3 to 5($3.4{\pm}0.4mm$) and the width is improved 2 to 4mm($2.9{\pm}0.5mm$) by the epicanthoplasty used levator plication. Conclusion: The improvement of the eyelid length is almost the same as epicanthoplasty and levator plication are done simultaneously. But the improvement of the eyelid width is less shorter when epicanthoplasty and levator plication are done simultaneously than the case of levator plication alone. This is because there is a tension influencing on the limitation of widening palpebral fissure to fix the epicanthal tendon. This method is recommendable for the patients who want to have much bigger eyes.

Strategies of upper blepharoplasty in aging patients with involutional ptosis

  • Lee, Tae-Yul;Shin, Yong Ho;Lee, Jin Gyu
    • Archives of Plastic Surgery
    • /
    • v.47 no.4
    • /
    • pp.290-296
    • /
    • 2020
  • In many aging individuals, dermatochalasis and involutional ptosis appear together. Therefore, for functional and aesthetic purposes, ptosis correction and upper blepharoplasty are performed together. The aim of this article is to investigate factors that should be considered in order to achieve good results when simultaneously performing involutional ptosis correction and upper blepharoplasty in aging patients. Involutional ptosis is usually corrected through aponeurosis advancement in mild cases. In moderate or severe ptosis, the Muller muscle and aponeurosis are used together to correct ptosis. Using the two muscles together has the advantages of reducing lagophthalmos and increasing the predictability of outcomes after surgery. Broadly speaking, the surgical method used for involutional ptosis varies depending on the specific case, but unlike congenital ptosis, it is often not necessary to perform overcorrection. In particular, if there are problems such as severe dry-eye symptoms or risk of lagophthalmos, undercorrection should be considered. When performing ptosis correction, the surgeon should be careful not to overdo skin excision; instead, limited excision should be performed. After ptosis surgery, the brow may descend and the double fold may look too small. However, in order to make the double eyelids look larger, the surgeon should consider making the double eyelid design high rather than excising an excessive amount of skin. In some cases, to obtain more natural double eyelids and favorable results, it may be necessary to perform a sub-brow lift or forehead lift before or after involutional ptosis surgery.

A COMPARATIVE STUDY ON THE CORRECTION METHODS OF NOSTRIL IN PATIENTS WITH CLEFT LIP NASAL DEFORMITY (구순열비변형 환자에서 비교정술에 대한 비교 연구)

  • Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.4
    • /
    • pp.287-294
    • /
    • 2006
  • The secondary correction of cleft lip nasal deformity (CLND) presents difficult surgical problems. Characteristically, nostrils are asymmetric. The present study was aimed to examine and compare the effect of Straith's alar web Z-plasty, Millard's alar web Z-plasty, alar web excision, and lateral V-Y advancement of the alar base for augmentation of the nostril with or without lengthening the columella in CLND. The subjects were 28 patients with unilateral cleft lip, who had secondary nostril correction. The nostril correction methods were Straith's alar web Z-plasty, Millard's alar web Z-plasty, alar web excision, and lateral V-Y advancement of the alar base. Facial photographs were taken before and 20 days after the operation. By using Adobe photoshop, the columella length and the nostril width were measured from the facial frontal photograph and Worm's eye view. The degree of improvement was calculated and statistically analyzed. The degree of improvement of the columella length using Straith's alar web Z-plasty was 70.20%. And then Millard's alar web Z-plasty was 55.01%, alar web excision was 39.93%, and lateral V-Y advancement of the alar base was 16.38% in order. The degree of improvement of the nostril size using lateral V-Y advancement of the alar base was 55.26%. And then alar web excision was 52.72%, Millard's alar web Z-plasty was 34.86%, and Straith's alar web Z-plasty was 16.06% in order. Straith's alar web Z-plasty and Millard's alar web Z-plasty resulted in elongation of the columella, equalization of asymmetrical nostril, and enlargement of small nostrils. Alar web excision enlarged nostrils and restored symmetry. Lateral VY advancement of the alar base increased nostril width and enlarged nostrils. These results indicate that the correction of nostrils improve the shape and the symmetry of the nostrils in CLND.

Effects of Induced Dioptric Blur on Visual Acuity and Contrast Sensitivity (유발된 광학적 흐림이 시력과 대비감도에 미치는 영향)

  • Kim, Chang-Jin;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.261-270
    • /
    • 2014
  • Purpose: To study the effect of an artificially induced dioptric blur on acuity and contrast sensitivity using the $Optec^{(R)}$ 6500. Methods: Healthy 31 subjects aged $22.90{\pm}1.92$ (male 16, female 15) who were recruited from university students with 6/6 (20/20) or better corrected visual acuity and normal binocularity. They were measured objective and subjective refraction for full correction and dioptric blur using 0.00 ~ +3.00 D (+0.50 D steps) trial lenses and trial frame. They were measured binocularly visual acuity and contrast sensitivity with the $Optec^{(R)}$ 6500 (Stereo Optical Co., Inc., Chicago, Illinois, USA) under day conditions (photopic condition, $85cd/m^2$). Results: The higher dioptric blur, the less distance visual acuity and decrease rate of visual acuity. The higher dioptric blur, the less contrast sensitivity at all frequencies, and the peak of contrast sensitivity was shifted from middle frequency (6 cpd) to low frequency (1.5 cpd). When the visual acuity was best visual acuity to 0.77, there was the peak point at 6 cpd which was normal contrast sensitivity peak point. Conclusions: If the low refractive error is uncorrected or the refractive error is inappropriate, the contrast sensitivity is decreased and the peak point of contrast sensitivity frequency is shifted abnormally though small uncorrected refractive error. So it will be considered that regular eye test and decision of refractive error correction is important.

The Usefulness of F-18-FDG PET and The Effect of Scan Protocol in Diagnosis of Intraocular Tumors (안구 내 종양의 진단에 있어서 F-18-FDG PET의 유용성과 검사 방법의 영향)

  • Lee, Jae-Soung;Yang, Won-Il;Kim, Byoung-Il;Choi, Chang-Woon;Lim, Sang-Moo;Lee, Tae-Won;Sin, Min-Kyeung;Hong, Soung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.5
    • /
    • pp.439-451
    • /
    • 1999
  • Purpose : It is important to differentiate malignant from benign lesions of intraocular masses in choosing therapeutic plan. Biopsy of intraocular tumor is not recommended due to the risk of visual damage. We evaluated the usefulness of F-18-FDG PET imaging in diagnosing intraocular neoplasms. Materials and Methods: F-18-FDG PET scan was performed in 13 patients (15 lesions) suspected to have malignant intraocular tumors. There were 3 benign lesions (retinal detachment, choroidal effusion and hemorrhage) and 10 patients with 12 malignant lesions (3 melanomas, 7 retinoblastomas and 2 metastatic cancers). Regional eye images ($256{\times}256$ and $128{\times}128$ matrices) were obtained with or without attenuation correction. Whole body scan was also performed in eight patients (3 benign and 6 malignant lesions). Results: All malignant lesions were visualized while all benign lesions were not visualized. The mean peak standardized uptake value (SUV) of malignant lesions was $2.64{\pm}0.57g/ml$. There was no correlations between peak SUV and tumor volume. Two large malignant lesions ($> 1000 mm^3$) showed hot uptake on whole body scan. But two medium-sized lesions ($100-1000mm^3$) looked faint and two small ($<100mm^3$) lesions were not visualized. The images reconstructed with $256{\times}256$ matrix showed lesions more clearly than those with $128{\times}128$ matrix Conclusion: F-18-FDG PET scan is highly sensitivity in detecting malignant intraocular tumor For the evaluation of small-sized intraocular lesions, whole body scan is not appropriate because of low sensitivity. A regional scan with sufficient acquisition time is recommended for that purpose. Image reconstruction in matrix size of $256{\times}256$ produced clearer images than the ones in $128{\times}128$, but it does not affect the diagnostic sensitivity.

  • PDF

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF