• Title/Summary/Keyword: Correction method

Search Result 3,419, Processing Time 0.031 seconds

Convolutional Neural Network Model Using Data Augmentation for Emotion AI-based Recommendation Systems

  • Ho-yeon Park;Kyoung-jae Kim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.12
    • /
    • pp.57-66
    • /
    • 2023
  • In this study, we propose a novel research framework for the recommendation system that can estimate the user's emotional state and reflect it in the recommendation process by applying deep learning techniques and emotion AI (artificial intelligence). To this end, we build an emotion classification model that classifies each of the seven emotions of angry, disgust, fear, happy, sad, surprise, and neutral, respectively, and propose a model that can reflect this result in the recommendation process. However, in the general emotion classification data, the difference in distribution ratio between each label is large, so it may be difficult to expect generalized classification results. In this study, since the number of emotion data such as disgust in emotion image data is often insufficient, correction is made through augmentation. Lastly, we propose a method to reflect the emotion prediction model based on data through image augmentation in the recommendation systems.

Assessment of Atmospheric Greenhouse Gas Concentration Equipment Performance (대기 중 온실가스 농도 관측 장비 성능 비교 검증)

  • Chaerin Park;Sujong Jeong;Seung-Hyun Jeong;Jeong-il Lee;Insun Kim;Cheol-Soo Lim
    • Atmosphere
    • /
    • v.33 no.5
    • /
    • pp.549-560
    • /
    • 2023
  • This study evaluates three distinct observation methods, CRDS, OA-ICOS, and OF-CEAS, in greenhouse gas monitoring equipment for atmospheric CO2 and CH4 concentrations. The assessment encompasses fundamental performance, high-concentration measurement accuracy, calibration methods, and the impact of atmospheric humidity on measurement accuracy. Results indicate that within a range of approximately 500 ppm, all three devices demonstrate high accuracy and linearity. However, beyond 1000 ppm, CO2 accuracy sharply declines (84%), emphasizing the need for caution when interpreting high-concentration CO2 data. An analysis of calibration methods reveals that both CO2 and CH4 measurements achieve high accuracy and linearity through 1-point calibration, suggesting that multi-point calibration is not imperative for precision. In dynamic atmospheric conditions with significant CO2 and CH4 concentration variations, a 1-point calibration suffices for reliable data (99% accuracy). The evaluation of humidity impact demonstrates that humidity removal devices significantly reduce air moisture levels, yet this has a negligible effect on dry CO2 concentrations (less than 0.5% relative error). All three observation method instruments, which have integrated humidity correction to calculate dry CO2 concentrations, exhibit minor sensitivity to humidity removal devices, implying that additional removal devices may not be essential. Consequently, this study offers valuable insights for comparing data from different measurement devices and provides crucial information to consider in the operation of monitoring sites.

Which is the More Important Factor for Users' Adopting the Serious Games for Health? Effectiveness or Safety (건강 기능성 게임의 확산을 위한 유통 전략 연구: 유효성과 안전성에 대한 사용자 인식을 중심으로)

  • Yong-Young Kim
    • Journal of Industrial Convergence
    • /
    • v.21 no.9
    • /
    • pp.23-32
    • /
    • 2023
  • Interest in Serious Games for Healthcare (SGHs) that can improve health through games is increasing. Digital Therapeutics (DTx) is a treatment that must be approved for effectiveness and safety, so it should follow the traditional drug distribution method, but SGHs are wellness products that are more flexible in terms of adoption and diffusion than DTx. SGHs are effective because it can provide customized services through continuous monitoring and feedback. When SGHs are applied to cognitive impairment treatment or behavioral correction, malfunctions and side effects are minor. This study developed research model based on the Valence Framework, gathered data from 142 undergraduates, and demonstrated that only the perceived benefits have a statistically significant positive (+) effect on SGHs acceptance intentions. Based on these results, this study suggests that SGHs companies should promote benefits in accepting SGHs for general users and they need for a distribution and analytics platform strategy based on a data-driven approach.

Prediction of Fire Curves Considering the Relationship between Mass Increase and Combustion Time of Combustibles (연소물의 질량증가와 연소시간의 상관관계를 고려한 화재곡선 예측)

  • Eun-Joon Nam;Tae-Il Lee;Goang-Seup Zi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.2
    • /
    • pp.9-16
    • /
    • 2024
  • In this paper, we aimed to convert the fire curve in volume units to a fire curve per unit area for application in the Fire Dynamic Simulator (FDS) surface heat release rate method. The fire curve was expressed dimensionlessly considering the total combustion characteristic time, and improvements were made to represent the appropriate ratios for the growth , steady, and decay phases concerning the fire intensity. Additionally, a correction function for combustion characteristic time varying with mass increase was derived. Also to control the growth time values according to the increase in mass, a function to correct the growth phase ratio was derived. Consequently, utilizing existing data, a formula was established to determine the reference mass for combustion materials and predict the fire curve based on mass increase.

Warping and porosity effects on the mechanical response of FG-Beams on non-homogeneous foundations via a Quasi-3D HSDT

  • Mokhtar Nebab;Hassen Ait Atmane;Riadh Bennai;Mouloud Dahmane
    • Structural Engineering and Mechanics
    • /
    • v.90 no.1
    • /
    • pp.83-96
    • /
    • 2024
  • This paper suggests an analytical approach to investigate the free vibration and stability of functionally graded (FG) beams with both perfect and imperfect characteristics using a quasi-3D higher-order shear deformation theory (HSDT) with stretching effect. The study specifically focuses on FG beams resting on variable elastic foundations. In contrast to other shear deformation theories, this particular theory employs only four unknown functions instead of five. Moreover, this theory satisfies the boundary conditions of zero tension on the beam surfaces and facilitates hyperbolic distributions of transverse shear stresses without the necessity of shear correction factors. The elastic medium in consideration assumes the presence of two parameters, specifically Winkler-Pasternak foundations. The Winkler parameter exhibits variable variations in the longitudinal direction, including linear, parabolic, sinusoidal, cosine, exponential, and uniform, while the Pasternak parameter remains constant. The effective material characteristics of the functionally graded (FG) beam are assumed to follow a straightforward power-law distribution along the thickness direction. Additionally, the investigation of porosity includes the consideration of four different types of porosity distribution patterns, allowing for a comprehensive examination of its influence on the behavior of the beam. Using the virtual work principle, equations of motion are derived and solved analytically using Navier's method for simply supported FG beams. The accuracy is verified through comparisons with literature results. Parametric studies explore the impact of different parameters on free vibration and buckling behavior, demonstrating the theory's correctness and simplicity.

Treatment outcome and long-term stability of orthognathic surgery for facial asymmetry: A systematic review and meta-analysis

  • Yoon-Ji Kim;Moon-Young Kim;Nayansi Jha;Min-Ho Jung;Yong-Dae Kwon;Ho Gyun Shin;Min Jung Ko;Sang Ho Jun
    • The korean journal of orthodontics
    • /
    • v.54 no.2
    • /
    • pp.89-107
    • /
    • 2024
  • Objective: This systematic review aimed to provide a comparative analysis of the treatment outcomes, including hard and soft tissues, postoperative stability, temporomandibular disorders (TMD), and quality of life (QoL), in patients with facial asymmetry who underwent orthognathic surgery. Methods: The primary objective was to address the question, "How do different factors related to surgery affect the outcomes and stability of orthognathic surgery in the correction of facial asymmetry?" A meta-analysis was conducted on the outcome parameters, such as skeletal, dental, and soft tissue symmetry, TMD, QoL, and relapse, using the Hartung-Knapp-Sidik-Jonkman method for random-effects models. Subgroup analyses were conducted considering surgery-related factors such as surgical techniques (one-jaw vs. two-jaw), use of the surgery-first approach, utilization of computer simulation, and analytical methods employed to evaluate asymmetry (2D vs. 3D). Results: Forty-nine articles met the inclusion criteria. The metaanalysis demonstrated a significant improvement in the symmetry of hard and soft tissues. The subgroup analysis indicated that the treatment outcomes showed significant improvement, regardless of the factors related to surgery. Changes in TMD signs and symptoms varied according to the surgical technique used. Quality of life improved in the facial, oral, and social domains. Skeletal relapse was observed during the follow-up. Conclusions: Our findings support the positive outcomes of orthognathic surgery in the treatment of facial asymmetry in terms of skeletal and soft tissue improvements, stability, relief of TMD symptoms, and enhancement of QoL. However, most of the included studies showed a low certainty of evidence and high heterogeneity.

GFRs Measured by Gates' Method According to 5 Background Sites: Comparison with GFR Measured by I-125-Iothalamate Method (다양한 배후 방사능 설정에 따른 Cates 법 사구체 여과율의 차이: I-125-Iothalamate 측정법과의 비교)

  • Jung, Hyun-Seok;Chung, Yong-An;Kim, Sung-Hoon;Kim, Chung-Ho;Lee, Sung-Young;Sohn, Hyung-Seon;Baik, Jun-Hyun;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.306-310
    • /
    • 2004
  • Purpose: The aim was to assess how the background site affects the Gates' glomerular filtration rate(GFR) measurement using Tc-99m-DTPA in correlation with GFR by I-125-lothalamate method. Material and methods: The study populations were 63 adults with 39 men and 24 women aged from 20 to 59 yrs (mean=37.9 yrs). The fellowing five background regions of interest were used in measurement of GFR using Gates' method: 1) lower side of each kidney(subrenal), 2) around each kidney(circumferential), 3) upper side of each kidney(suprarenal), 4) lateral side of each kidney(lateral), 5) between the two kidneys(inter-renal). We also measured GFR using I-125-iothalamate in each subject. The two studies were separated by 1 to 3 weeks. The subjects were divided into two groups by renal depth. Group 1 with renal $depth{\geq}7cm$ and group 2 with renal depth<7cm. We calculated the means and standard deviations of the GFRs measured by two studies. And we statistically analyzed the correlation and differences among GFRs by Gates' method and the GFR by iothalamate method with correlation analysis. Results: The GFRs by Gates' method using suprarenal and inter-renal background correction showed better correlation with the GFR measured by I-125-iothalamate. And GFRs measured by Gates' method showed statistically significant correlation with the GFR measured by I-125-iothalamate in the group with renal depth<7cm. But GFRs measured by Gates' method did not show statistically significant correlation with the GFR measured by I-125-iothalamate in the group with renal $depth{\geq}7cm$. Conclusion: GFRs measured with Gates' method showed higher correlation with the GFR measured by I-125-iothalamate when the regions of interest were plated over the suprarenal and inter-renal backgrounds. And GFRs measured with Gates method showed statistically significant correlation with the GFR measured by I-125-iothalamate in the group with renal depth<7cm.

The Difference of Standardized Uptake Value on PET-CT According to Change of CT Parameters (PET-CT에서 CT의 관전압 및 관전류에 따른 SUV값의 변화)

  • Shin, Gyoo-Seul;Dong, Kyeong-Rae
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.373-379
    • /
    • 2007
  • Purpose : There is difference between PET and PET/CT method on their transmission image for attenuation correction. The CT image is used for attenuation correction on PET/CT and the parameters of CT may be affected on PET image. We performed the phantom study to evaluate whether the change of CT parameters(kilovolts peak and milliampere) affect standardized uptake value(SUV) on PET image. Material and Method: The data spectrum lung phantom containing diluted [18F]fluorodeoxyglucose ([18F]FDG) solution(1.909 mCi for phantom 1, $913\;{\mu}Ci$ for phantom 2) was used. The CT images of phantom were acquired with varying parameters (80, 100, 120, 140 for kVp, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 for mA). The PET images were reconstructed with the each CT images and SUVs were compared. Result : The SUVs of phantom 1 reconstructed with each 80, 100, 120 and 140 kVp showed $12.26{\pm}0.009$, $12.27{\pm}0.005$, $12.27{\pm}0.006$ and $12.27{\pm}0.009$, respectively. The SUVs of phantom 2 revealed $4.52{\pm}0.043$, $4.53{\pm}0.004$, $4.52{\pm}0.007$ and $4.52{\pm}0.005$ with elevation of voltage. There was no statistically significant difference of SUVs between groups based on various kVp. Also SUVs of phantom 1 and 2 showed no significant change with elevation of milliampere in CT parameter. Conclusion : The parameters of CT did not significantly affect SUV on PET image in our study. Therefore we can apply various parameters of CT appropriated for clinical conditions without significant change of SUV on PET CT image.

  • PDF

Evaluation of Image Quality Change by Truncated Region in Brain PET/CT (Brain PET에서 Truncated Region에 의한 영상의 질 평가)

  • Lee, Hong-Jae;Do, Yong-Ho;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.68-73
    • /
    • 2015
  • Purpose The purpose of this study was to evaluate image quality change by truncated region in field of view (FOV) of attenuation correction computed tomography (AC-CT) in brain PET/CT. Materials and Methods Biograph Truepoint 40 with TrueV (Siemens) was used as a scanner. $^{68}Ge$ phantom scan was performed with and without applying brain holder using brain PET/CT protocol. PET attenuation correction factor (ACF) was evaluated according to existence of pallet in FOV of AC-CT. FBP, OSEM-3D and PSF methods were applied for PET reconstruction. Parameters of iteration 4, subsets 21 and gaussian 2 mm filter were applied for iterative reconstruction methods. Window level 2900, width 6000 and level 4, 200, width 1000 were set for visual evaluation of PET AC images. Vertical profiles of 5 slices and 20 slices summation images applied gaussian 5 mm filter were produced for evaluating integral uniformity. Results Patient pallet was not covered in FOV of AC-CT when without applying brain holder because of small size of FOV. It resulted in defect of ACF sinogram by truncated region in ACF evaluation. When without applying brain holder, defect was appeared in lower part of transverse image on condition of window level 4200, width 1000 in PET AC image evaluation. With and without applying brain holder, integral uniformities of 5 slices and 20 slices summation images were 7.2%, 6.7% and 11.7%, 6.7%. Conclusion Truncated region by small FOV results in count defect in occipital lobe of brain in clinical or research studies. It is necessary to understand effect of truncated region and apply appropriate accessory for brain PET/CT.

  • PDF

Real-time Body Surface Motion Tracking using the Couch Based Computer-controlled Motion Phantom (CBMP) and Ultrasonic Sensor: A Feasibility Study (CBMP (Couch Based Computer-Controlled Motion Phantom)와 초음파센서에 기반한 실시간 체표면 추적 시스템 개발: 타당성 연구)

  • Lee, Suk;Yang, Dae-Sik;Park, Young-Je;Shin, Dong-Ho;Huh, Hyun-Do;Lee, Sang-Hoon;Cho, Sam-Ju;Lim, Sang-Wook;Jang, Ji-Sun;Cho, Kwang-Hwan;Shin, Hun-Joo;Kim, Chul-Yong
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.27-34
    • /
    • 2007
  • Respiration sating radiotherapy technique developed In consideration of the movement of body surface and Internal organs during respiration, is categorized into the method of analyzing the respiratory volume for data processing and that of keeping track of fiducial landmark or dermatologic markers based on radiography. However, since these methods require high-priced equipments for treatment and are used for the specific radiotherapy. Therefore, we should develop new essential method whilst ruling out the possible problems. This study alms to obtain body surface motion by using the couch based computer-controlled motion phantom (CBMP) and US sensor, and to develop respiration gating techniques that can adjust patients' beds by using opposite values of the data obtained. The CBMP made to measure body surface motion is composed of a BS II microprocessor, sensor, host computer and stopping motor etc. And the program to control and operate It was developed. After the CBMP was adjusted by entering random movement data, and the phantom movements were acquired using the sensors, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using a rabbit, the real-time respiration gating techniques were drawn by operating the phantom with the opposite values of the data. The result of analysing the acquisition-correction delay time for the data value shows that the data value coincided within 1% and that the acquistition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. And the movement was the maximum movement was 6 mm In Z direction, In which the respiratory cycle was 2.9 seconds. This study successfully confirms the clinical application possibility of respiration gating techniques by using a CBWP and sensor.

  • PDF