• Title/Summary/Keyword: Correction method

Search Result 3,419, Processing Time 0.05 seconds

The push-out bond strength of BIOfactor mineral trioxide aggregate, a novel root repair material

  • Akbulut, Makbule Bilge;Bozkurt, Durmus Alperen;Terlemez, Arslan;Akman, Melek
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.1
    • /
    • pp.5.1-5.9
    • /
    • 2019
  • Objectives: The aim of this in vitro study was to evaluate the push-out bond strength of a novel calcium silicate-based root repair material-BIOfactor MTA to root canal dentin in comparison with white MTA-Angelus (Angelus) and Biodentine (Septodont). Materials and Methods: The coronal parts of 12 central incisors were removed and the roots were embedded in acrylic resin blocks. Midroot dentin of each sample was horizontally sectioned into 1.1 mm slices and 3 slices were obtained from each root. Three canal-like standardized holes having 1 mm in diameter were created parallel to the root canal on each dentin slice with a diamond bur. The holes were filled with MTA-Angelus, Biodentine, or BIOfactor MTA. Wet gauze was placed over the specimens and samples were stored in an incubator at $37^{\circ}C$ for 7 days to allow complete setting. Then samples were subjected to the push-out test method using a universal test machine with the loading speed of 1 mm/min. Data was statistically analyzed using Friedman test and post hoc Wilcoxon signed rank test with Bonferroni correction. Results: There were no significant differences among the push-out bond strength values of MTA-Angelus, Biodentine, and BIOfactor MTA (p > 0.017). Most of the specimens exhibited cohesive failure in all groups, with the highest rate found in Biodentine group. Conclusions: Based on the results of this study, MTA-Angelus, Biodentine, and BIOfactor MTA showed similar resistances to the push-out testing.

Compensation for The Solar Radiation Effect of Radiosonde's Temperature Sensor Using Solar Panel (솔라패널을 이용한 라디오존데 온도센서의 일사보정)

  • Park, Myeong-Seok;Lee, Jin-Wook;Jeung, Se-Jin;Jang, Jea-Won
    • Atmosphere
    • /
    • v.29 no.3
    • /
    • pp.283-294
    • /
    • 2019
  • For the upper air observations, a temperature measurement using radiosonde is a common method, and the compensation of solar radiation effects in the radiosonde temperature sensor is an important factor. In this paper, we present various experiments and compensation methods of the radiosonde temperature sensor to overcome the errors caused by the movement of the radiosonde rotation, etc. The methods and procedures of this study are as follows. First, we used the solar simulator to analyze the temperature variation and solar effect of the temperature sensor in the radiosonde according to the insolation. We also analyzed the temperature variation and solar effect of the temperature sensor according to the incident angle between the solar simulator and radiosonde. Second, we measured and analyzed solar radiation absorbed by solar cells attached to radiosonde. Third, we present combined compensate solution of the first and the second experiment results, to overcome errors caused by insolation effects in the radiosonde temperature sensors. Fourth, we compared that the reference temperature in similar environment with the upper air conditions, to verify the new radiated compensation performance of the radiosonde temperature sensor. Finally, the radiosonde fabricated in this study was raised to the atmosphere, and the laser correction algorithm proposed through experiments was reviewed. As a result of the radiosonde SRS-10 produced in this study, the temperature deviation from Vaisala RS92 was $0.057^{\circ}C$ in nighttime observation, $0.17^{\circ}C$ in daytime observation, It is expected that the GRUAN under WMO will be able to obtain a high test rating of 5.0.

Nonlinear thermoelastic analysis of FGM thick plates

  • Bouhlali, Malika;Chikh, Abdelbaki;Bouremana, Mohammed;Kaci, Abdelhakim;Bourada, Fouad;Belakhdar, Khalil;Tounsi, Abdelouahed
    • Coupled systems mechanics
    • /
    • v.8 no.5
    • /
    • pp.439-457
    • /
    • 2019
  • In this paper, a new application of a four variable refined plate theory to analyze the nonlinear bending of functionally graded plates exposed to thermo-mechanical loadings, is presented. This recent theory is based on the assumption that the transverse displacements consist of bending and shear components in which the bending components do not contribute toward shear forces, and similarly, the shear components do not contribute toward bending moments. The derived transverse shear strains has a quadratic variation across the thickness that satisfies the zero traction boundary conditions on the top and bottom surfaces of the plate without using shear correction factors. The material properties are assumed to vary continuously through the thickness of the plate according to a power-law distribution of the volume fraction of the constituents. The solutions are achieved by minimizing the total potential energy. The non-linear strain-displacement relations in the von Karman sense are used to derive the effect of geometric non-linearity. It is concluded that the proposed theory is accurate and simple in solving the nonlinear bending behavior of functionally graded plates.

An Improved Decoding Scheme of Hamming Codes using Soft Values (소프트 값을 이용한 해밍 부호의 개선된 복호 방식)

  • Cheong, Ho-Young
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.1
    • /
    • pp.37-42
    • /
    • 2019
  • In this paper, we propose a syndrome decoding scheme that can correct two errors for single error correcting Hamming codes within a code length. The decoding scheme proposed in this paper has the advantage of significantly improving the error rate performance compared to the decoder complexity by correcting multiple errors without substantially increasing the decoding complexity. It is suitable for applications in which the energy use of encoder/decoder is extremely limited and the low error rate performance is required, such as IoT communications and molecular communications. In order to verify the improvement of the error rate performance of the Hamming code with the proposed decoding scheme, we performed simulation on Hamming codes with short code length in the AWGN and BPSK modulation environments. As a result, compared with the conventional decoding method, the proposed decoding scheme showed performance improvement of about 1.1 ~ 1.2[dB] regardless of the code length of the Hamming code.

Valid Algorithm for Short Distance based on Mnemonic System in Mobile Environments (모바일 환경에서 기억법 기반 짧은 거리 유효 알고리즘)

  • Kim, Boon-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.2
    • /
    • pp.301-306
    • /
    • 2021
  • In the field of year-based interpretation of important data, memory laws can be used as a way to enhance educational effectiveness. Studies related to how to remember numbers are conducted in the form of increasing memory rates by presenting information in the form of conventional simple images. We attempt to supplement the method proposed in the paper of numerical algorithm for modifying errors based on mnemonic system in mobile environments. We want to complement the error correction numerical algorithm proposed in previous work. The study was a way to compensate the errors that occur when users enter numerical information in the apps they use. In this work, we want to increase the memory rate based on two-dimensional information by imposing the concept of angles, rather than simply showing data to help recall memories from mistakes. To this end, we propose a problem-solving process using developed app, and implement and evaluate the short distance valid algorithms.

A Study on the Design of Small SMT Platform for Education (교육용 소형 SMT 플랫폼 설계에 관한 연구)

  • Park, Se-Jun
    • Journal of Platform Technology
    • /
    • v.8 no.1
    • /
    • pp.24-32
    • /
    • 2020
  • This paper designed and manufactured a chip mounter based on 3D printer technology that can be used for educational research or sample production to disseminate chip mounter, a core technology of SMT line. A stepper motor with open loop control is used for low cost drive design. The shortcomings of the motor's vibration and disassembly caused by the use of the step motor were compensated by the Micro-Step control method. In the chip mounter experiment, the gerber file was generated on the small chip mounter, printed at the actual size, and the solder cream was printed on the HASL-treated PCB in the same manner as the sample board fabrication. As a result of the experiment, unlike the 2012 micro components, parts such as SOIC and TQFP that require correction are twice as long as the component mounting time, but it can be confirmed that they are mounted relatively accurately. In addition, as a result of repeatedly measuring the error of the initial position 10 times, it was confirmed that a relatively small error of about 0.110mm occurs.

  • PDF

Underwater Drone Development for Ship Inspection Part 1: Design, Production and Testing (선박 검사용 수중 드론 개발 Part 1: 설계·제작 및 시험)

  • Ha, Yeon-Chul;Kim, Jin-Woo;Kim, Goo;Jeong, Kyeong-Teak;Choi, Hyun-Deuk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.1
    • /
    • pp.38-48
    • /
    • 2020
  • In order to inspect the existing or newly constructed ship's hull, a professional diver directly inspects the ship's bottom of the water. However, since it is a work done by people, there are many dangers such as human casualties and crashes. To solve this problem, it is necessary to develop underwater drones for ship inspection for visual inspection. The technology applied to underwater drones, the use and manufacturing process of each component, and the method of manufacture such as firmware development were described, and the difference was compared by measuring the drone's own driving ability and driving ability using crawler under water, and the location tracking device test confirmed the error from the actual location. It is estimated that the use of underwater drones produced through this research will prevent human casualties and achieve economic effects and stability.

The Manufacture of Digital X-ray Devices and Implementation of Image Processing Algorithm (디지털 X-ray 장치 제작 및 영상 처리 알고리즘 구현)

  • Kim, So-young;Park, Seung-woo;Lee, Dong-hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.195-201
    • /
    • 2020
  • This study studied scoliosis, one of the most common modern diseases caused by lifestyle patterns of office workers sitting in front of computers all day and modern people who use smart phones frequently. Scoliosis is a typical complication that takes more than 80% of the nation's total population at least once. X-ray are used to test for these complications. X-ray, a non-destructive testing method that allows scoliosis to be easily performed and filmed in various areas such as the chest, abdomen and bone without contrast agents or other instruments. We uses NI DAQ to miniaturize digital X-ray imaging devices and image intensifier in self-shielding housing with Vision Assistant for drawing lines to the top and the bottom of the spine to acquire angles, i.e. curvature in real-time. In this way, the research was conducted to see scoliosis patients and their condition easily and to help rapid treatment for solving the problem of posture correction in modern people.

Feasibility Study for an Optical Sensing System for Hardy Kiwi (Actinidia arguta) Sugar Content Estimation

  • Lee, Sangyoon;Sarkar, Shagor;Park, Youngki;Yang, Jaekyeong;Kweon, Giyoung
    • Journal of agriculture & life science
    • /
    • v.53 no.3
    • /
    • pp.147-157
    • /
    • 2019
  • In this study, we tried to find out the most appropriate pre-processing method and to verify the feasibility of developing a low-price sensing system for predicting the hardy kiwis sugar content based on VNIRS and subsequent spectral analysis. A total of 495 hardy kiwi samples were collected from three farms in Muju, Jeollabukdo, South Korea. The samples were scanned with a spectrophotometer in the range of 730-2300 nm with 1 nm spectral sampling interval. The measured data were arbitrarily separated into calibration and validation data for sugar content prediction. Partial least squares (PLS) regression was performed using various combinations of pre-processing methods. When the latent variable (LV) was 8 with the pre-processing combination of standard normal variate (SNV) and orthogonal signal correction (OSC), the highest R2 values of calibration and validation were 0.78 and 0.84, respectively. The possibility of predicting the sugar content of hardy kiwi was also examined at spectral sampling intervals of 6 and 10 nm in the narrower spectral range from 730 nm to 1200 nm for a low-price optical sensing system. The prediction performance had promising results with R2 values of 0.84 and 0.80 for 6 and 10 nm, respectively. Future studies will aim to develop a low-price optical sensing system with a combination of optical components such as photodiodes, light-emitting diodes (LEDs) and/or lamps, and to locate a more reliable prediction model by including meteorological data, soil data, and different varieties of hardy kiwi plants.

Investigation of Standard Error Range of Non-Contact Thermometer by Environment (외부 환경 변화에 의한 비 접촉 체온계의 오차 범위 측정)

  • Kim, Jeongeun;Park, Sangwoong;Choi, Heakyung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.307-321
    • /
    • 2020
  • Purpose : A person infected by SARS-CoV2 may present various symptoms such as fever, pain in lower respiratory tract, and pneumonia. Measuring body temperature is a simple method to screen patients. However, changes in the surrounding environment may cause errors in infrared measurement. Hence, a non-contact thermometer controls this error by setting a correction value, but it is difficult to correct it for all environments. Therefore, we investigate device error values according to changes in the surrounding environment (temperature and humidity) and propose guidelines for reliable patient detection. Methods : For this study, the temperature was measured using three types of non-contact thermometers. For accurate temperature measurement, we used a water bath kept at a constant temperature. During temperature measurement, we ensured that the temperature and humidity were maintained using a thermo-hygrometer. The conditions of the surrounding environment were changed by an air conditioner, humidifier, warmer, and dehumidifier. Results : The temperature of the water bath was measured using a non-contact thermometer kept at various distances ranging from 3~10 cm. The value measured by the non-contact thermometer was then verified using a mercury thermometer, and the difference between the measured temperatures was compared. It was observed that at normal surrounding temperature (24 ℃), there was no difference between the values when the non-contact thermometer was kept at 3 cm. However, as the distance of the non-contact thermometer was increased from the water bath, the recorded temperature was significantly different compared with that of mercury thermometer. Moreover, temperature measurements were conducted at different surrounding temperatures and the results obtained significantly varied from when the thermometer was kept at 3 cm. Additionally, it was observed that the effect on temperature decreases with an increase in humidity Conclusion : In conclusion, non-contact thermometers are lower in lower temperature and dry weather in winter.