• Title/Summary/Keyword: Corrected visual acuity

Search Result 91, Processing Time 0.022 seconds

Contrast Sensitivity and Glare with Spherical and Toric Soft Contact Lenses in Low-astigmatic Eyes (구면과 토릭 소프트 렌즈로 교정한 약도 난시안의 대비감도와 눈부심)

  • Lee, Min-Ah;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the visual performance by contrast sensitivity (CS) and disability glare (DG) in low astigmatic eyes corrected with toric soft lenses and other optical corrections. Methods: Twenty university students with myopia (-1.00 to -6.50D Sph. with astigmatism up to 1.50 cyl) were enrolled and corrected by five different methods: 1) soft toric lenses; 2) spherical soft contact lenses; 3) RGP lenses; 4) best spectacle corrected visual acuity; 5) spherical equivalent spectacles. All subjects had corrected vision acuity of 20/20 or better. Contrast sensitivity and disability glare were measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView Functional Vision Analysis software at photopic or mesopic conditions with glare. Results: At photopic condition, best corrected spectacle wearers had the highest monocular contrast sensitivity at all spatial frequency followed by soft toric lenses, RGP lenses, spherical equivalent spectacles, and spherical soft contact lenses. However, all of them were in normal contrast sensitivity value at photopic condition. At mesopic condition with glare, toric soft lenses were the highest and followed by RGP lenses, spherical equivalent spectacles, best spectacle corrected visual acuity and spherical soft contact lenses. It was observed that spherical soft contact lens wearers demonstrated lower range than normal contrast sensitivity value at mesopic condition with glare. Conclusion: Toric soft lenses gave better visual performance than spherical soft lenses in low astigmatic eyes. Subjects requiring the use of contact lenses under mesophic conditions could benefit from toric soft lenses.

  • PDF

Visual Performances of the Corrected Navarro Accommodation-Dependent Finite Model Eye (안구의 굴절능 조절을 고려한 수정된 Navarro 정밀모형안의 시성능 분석)

  • Choi, Ka-Ul;Song, Seok-Ho;Kim, Sang-Gee
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.337-344
    • /
    • 2007
  • In recent years, there has been rapid progress in different areas of vision science, such as refractive surgical procedures, contact lenses and spectacles, and near vision. This progress requires a highly accurate modeling of optical performance of the human eyes in different accommodation states. A new novel model-eye was designed using the Navarro accommodation-dependent finite model eye. For each of the vergence distances, ocular wavefront error, accommodative response, and visual acuity were calculated. Using the new model eye ocular wavefront error, accommodation dative response, and visual acuity are calculated for six vergence stimuli, -0.17D, 1D, 2D, 3D, 4D and -5D. Also, $3^{rd}\;and\;4^{th}$ order aberrations, modulation transfer function, and visual acuity of the accommodation-dependent model eye were analyzed. These results are well-matched to anatomical, biometric, and optical realities. Our corrected accommodation-dependent model-eye may provide a more accurate way to evaluate optical transfer functions and optical performances of the human eye.

A Relationship between Kinetic Visual Acuity and Contrast Sensitivity (동적시력과 대비감도의 상관관계)

  • Shim, Moon-Sik;Kang, Hye-Sook;Kim, Sang-Hyun;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.225-229
    • /
    • 2014
  • Purpose: The study was to analyze the correlation between kinetic visual acuity (KVA), visual acuity(static visual angle, SVA) and contrast sensitivity. Methods: Ninety-nine undergraduate students studying Ophthalmic Optics were fully corrected by the Topcon CV-3000 Phoropter. The contrast sensitivity was measured for the participants under the photopic condition ($100cd/m^2$) with Vector Vision CSV-1000E at 2.5 meter, while KVA was measured with KOWA AS-4A. The participants were classified into three groups L, M and H depending on the KVA (0.1~0.3, 0.31~0.6 and greater than 0.61, respectively) and were analyzed whether there was the correlation between the contrast sensitivity, visual acuity and refractive error. Results: The KVA was correlated with the contrast sensitivity for 3 cpd (r=0.26), for 6 cpd (r=0.48), for 12 cpd (r=0.38) and 18 cpd (r=0.47). Except for the low frequency of 3 cpd, they all were higher than the one of the SVA and the KVA (r = -0.37). The contrast sensitivity for 3, 6, 12 and 18 cpd was 59.41, 92.22, 38.41 and 14.39 in the group L, respectively. The contrast sensitivity in the group M was 66.03, 108.78, 53.51 and 19.20 and the one in the group H was 70.90, 146.10, 62.90 and 25.33 for 3, 6, 12 and 18 cpd, respectively. Conclusions: The correlation of the contrast sensitivity and the KVA was higher than the one of the contrast sensitivity and the SVA. It can be assumed that the contrast sensitivity will be high if the KVA is high, except for the case for low spatial frequency.

Effects of Induced Dioptric Blur on Visual Acuity and Contrast Sensitivity (유발된 광학적 흐림이 시력과 대비감도에 미치는 영향)

  • Kim, Chang-Jin;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.261-270
    • /
    • 2014
  • Purpose: To study the effect of an artificially induced dioptric blur on acuity and contrast sensitivity using the $Optec^{(R)}$ 6500. Methods: Healthy 31 subjects aged $22.90{\pm}1.92$ (male 16, female 15) who were recruited from university students with 6/6 (20/20) or better corrected visual acuity and normal binocularity. They were measured objective and subjective refraction for full correction and dioptric blur using 0.00 ~ +3.00 D (+0.50 D steps) trial lenses and trial frame. They were measured binocularly visual acuity and contrast sensitivity with the $Optec^{(R)}$ 6500 (Stereo Optical Co., Inc., Chicago, Illinois, USA) under day conditions (photopic condition, $85cd/m^2$). Results: The higher dioptric blur, the less distance visual acuity and decrease rate of visual acuity. The higher dioptric blur, the less contrast sensitivity at all frequencies, and the peak of contrast sensitivity was shifted from middle frequency (6 cpd) to low frequency (1.5 cpd). When the visual acuity was best visual acuity to 0.77, there was the peak point at 6 cpd which was normal contrast sensitivity peak point. Conclusions: If the low refractive error is uncorrected or the refractive error is inappropriate, the contrast sensitivity is decreased and the peak point of contrast sensitivity frequency is shifted abnormally though small uncorrected refractive error. So it will be considered that regular eye test and decision of refractive error correction is important.

Loss of Corrected Visual Acuity According to Different Meridional Visual Acuity in Astigmatic Eyes (난시안에서 주경선 간 시력차이와 교정시력의 손실)

  • Jo, Na Young;Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.77-81
    • /
    • 2016
  • Purpose: This study was performed to investigate the difference of meridional visual acuity and the loss of corrected visual acuity (VA) in order to emphasis the importance of astigmatic correction. Methods: 64 subjects (122 eyes) aged $22.75{\pm}2.36years$ participated in this study. After full correction of astigmatic refractive error, VA was measured in which the direction of the slit filter was matched with astigmatic axis and $90^{\circ}$ to the astigmatic axis. Results: 52 eyes showed no difference in VA between the two direction. However 70 eyes had difference VA between them. 14 out of 52 eyes and 24 out of 70 eyes had under 1.0 in monocular VA. The astigmatic degree was higher in the existence of VA difference between the two direction than non-existence. The difference is higher with under 1.0 monocular VA. Monocular VA is closely related to the focal line having better VA in the principal focal line. Glasses replacement period was analyzed as 6~12 months for the preservation of better VA. Conclusions: The final glasses prescription has to be given with full correction because continued under-correction for astigmatism causes meridional VA difference.

Predicting of Uncorrected Astigmatism from Decimal Visual Acuity in Spherical Equivalent

  • Moon, Byeong-Yeon;Kim, Sang-Yoeb;Cho, Hyun Gug
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.219-223
    • /
    • 2013
  • The purpose of this study was to determine the relationship between the spherical equivalent visual acuity (VA) and uncorrected astigmatism. On 108 emmetropic eyes, the spherical equivalent VA was measured for cross cylindrical lens (CC lens)-induced astigmatic eyes and the VA-astigmatism relation determined. On 158 astigmatic eyes, the spherical equivalent VA and corrected astigmatism were measured and the measured values were compared with the calculated values from the VA-astigmatism relation by correlation coefficient analysis. Subsequent to that, the relationship between spherical equivalent VA and uncorrected astigmatism was made. The relationship was fitted for an exponential equation. Correlation coefficient between calculated values by equation and measured values for astigmatic eyes was 0.991 (p<0.01). The relationship between the spherical equivalent VA and the uncorrected astigmatism was decided as follows (spherical equivalent VA / uncorrected astigmatism): 1.0 / 0.25 D, 0.9 / 0.50 D, 0.8 / 0.75 D, 0.7 / 1.00 D, 0.6 / 1.25 D, 0.5 / 1.50 D, 0.4 / 2.00 D, 0.3 / 2.50 D, 0.2 / 3.00 D, 0.1 / 4.00 D, and 0.05 / 4.75 D. In conclusion, the relationship table devised from this study is a useful reference for predicting uncorrected astigmatism by measurement of decimal VA in spherical equivalent.

Lens Design of the Eyepiece Combined with the Accommodation-dependent Navarro Eye at an On-axis Point

  • Choi, Ka-Ul;Song, Seok-Ho;Kim, Sang-Gee
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.55-62
    • /
    • 2010
  • We introduce a new method for lens design that combines an eyepiece with the finite model eye, to make a corrected version of the accommodation-dependent Navarro eye. The optical system that we designed, which includes a human eye, takes into account the aberration of the eye and increases the performance of the image in the retina. In the design results, for the optimized eyepiece combined with the corrected Navarro eye, visual acuity is 1.40. Compared with the existing method of eyepiece design using inverse ray tracing with the corrected Navarro eye, MTF value was recorded as 0.079 to 0.283 at 160 lp/mm and visual performance was improved.

Clinical Evaluation on Variation of Face Form Angle of Eyewear (안경 안면각 변화에 대한 임상적 고찰)

  • Ko, Da-young;Kim, Ki-hong;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.477-484
    • /
    • 2015
  • Purpose: This study was investigated to evaluate the effect of the variation of the face form angle(FFA) of spectacle frame on the visual acuity and the visual function. Methods: The visual acuity, the contrast sensitivity, the stereopsis, and the phoria were measured with the spectacle frame whose the FFA is at $5^{\circ}$ and $25^{\circ}$ and the surveys were conducted on subjective symptoms. Here, 30 adults (14 men and 16 women, average age:$25.46{\pm}3.9$), who did not have ocular diseases and were fully corrected in case of having had refractive error, were to act as experimental subjects for this measurement. Results: The visual acuity and the contrast sensitivity was decreased and the phoria was tended to increase to the esophoria direction at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. The stereopsis was significantly reduced at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. Also when the FFA was larger, the higher the degree of refractive error was, the more the increase of the subjective symptoms such as being blurred characters, being disturbed head, and having sore eyes was, which reveals a statistically significant correlation between them. Conclusions: If the FFA increases, the visual acuity, the contrast sensitivity and the stereopsis was found to decrease and the phoria to increase to the esophoria direction. Therefore it shows that the variation of the FFA of spectacle frame can influence the visual acuity and the visual function.

Study on Relationship between Eye Health and Household Income of the Elderly (노인의 가구 소득과 눈 건강과의 관계)

  • Park, Jee-Hyun;Kim, Hyo-Jin;Ye, Ki-Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.209-217
    • /
    • 2011
  • Purpose: In this study, eye-health inequity was investigated by analyzing the relationship between household incomes and eye-health of senior citizens. Further, this study suggested the preliminary data for establishment of public eye-health policy in order to improve low income senior citizens' life quality. Methods: The data from the 2009 Survey of Korea National Health and Nutrition Examination were analyzed in this study. The objectives of the KNHNE survey were over 65 year old group (1,668 people). Main factors of eye-health (visual acuity, cataract, pterygium, intraocular pressure, retinophathy, age-related macular degeneration, diabetic retinophathy, myopia, hyperopia, astigmatism, and anisometropia prevalence) were analyzed with t-test and chi square test. Results: Low income group revealed that refractive error rate and intraocular pressure were low, however, naked eye visual acuity and corrected visual acuity were high at 0.1 to less than 0.5. On the other hands, in the high income group, there was high prevalence of hyperopia. Cataract mainly occurred at low income group besides group which maximum corrected visual acuity was below 0.8 also highly showed cataract. Moreover, the prevalence of cataract showed that it related with smoking, drinking, occupation, and education level. Conclusions: Results revealed that there was inequity of eye-health which related with socioeconomic status of the elderly. Especially, the prevalence of cataract was correlated with life quality. Consequently, establishment of public eye-health policy seems to be required for eye-health inequity of low income senior citizens.

The effect of the visual impairment on the Island Elder (섬지역 노인의 시력장애 요인 실태조사)

  • Kim, Jeong Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.107-112
    • /
    • 2002
  • In order to investigate the situation of ocular disorders involving visual functions of elder in the Island area, the survey was carried out subjective methods on 228 persons(456 eyes) over the of 60. The analysis of data resulted in as follows : 1. Among the total 456 eyes, the ocular disorders was 54.8%. 2. The causes of ocular disorders with visual impairment ; Senile cataract(44.8%), Pterygium(55.2%) 3. Age distribution of cataract showed the sixties 46.4%, the seventies 37.5% and the eighties($80{\leq}$) 16.1%. 4. As to the distribution corrected visual acuity in cataract ; 0.1 below(8.9%). 0.1~0.3(14.3%), 0.4~0.6(36.6%), 0.7 over(40.2%). 5. Age distribution of pterygium showed the sixties 60.9%, the seventies 26.1% and the eighties($80{\leq}$) 13.0%. 6. As to the distribution corrected visual acuity in pterygium ; 0.1 below(5.l%), 0.1~0.3(5.8%), 0.4~0.6(20.3%), 0.7 over(68.8%).

  • PDF