• 제목/요약/키워드: Corona inception

검색결과 14건 처리시간 0.018초

Suppression of Glow Corona on Streamer and Influence of Thin Wire on its Inception

  • Sima, Wenxia;Fan, Shuochao;Yang, Qing;Wang, Qi
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1759-1764
    • /
    • 2015
  • Glow corona is a kind of streamer-free corona that can suppress upward leaders in transmission lines. Thus, it has good application potential in lightning protection. This paper investigates its corona characteristics. The suppression characteristic of glow corona on streamer is studied in air gap under negative DC voltage by wrapping thin wires on the electrode. The effect of thin wire winding patterns on the gap breakdown voltage is analyzed. Results are considered to be attributed to the inception condition of glow corona. Thus an inception test of glow corona is also conducted, and the inception voltage is obtained. Results show that the inception voltage decreases with short winding pitch. Thus an investigation on the inception of glow corona influenced by thin wire is conducted, and an influential factor is proposed to evaluate the influence. The inception regular of thin wire glow corona presented in this paper has certain reference value for the application of glow corona in transmission lines.

식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구 (A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer)

  • 정중일;허창수
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

$SF_6$ 기체와 $SF_{6}-N_{2}$ 혼합기체의 초기코로나 특성 (The first corona inception characteristics in $SF_6$ gas and $SF_{6}-N_{2}$ mixtures)

  • 이복희;김정일;박성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2002-2004
    • /
    • 2000
  • The discharge processes in electro-negative gases with non-uniform field gape are composed of the formation of pulsed streamer corona, the transition of the streamers into leader step, the temporal development of the leader channel, and the stepped propagation of leader through the gap. In this paper, the first corona inception characteristics in $SF_6$ gas and $SF_{6}-N_{2}$ mixtures, related to the propagation of loader and the space charge effect, were experimentally investigated with positive and negative transient impulse voltages.

  • PDF

DC 코로나 방전이 적용된 에틸렌 정상 확산 화염의 Soot 배출 저감 (Reduction of Soot Emitted from a $C_2$$H_4$ Normal Diffusion Flame with Application of DC Corona Discharge)

  • 이재복;황정호
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.496-506
    • /
    • 2001
  • The effect of corona discharge on soot emission was experimentally investigated. Size and number concentrations of soot aggregates were measured and compared for various voltages. Regardless of the polarity of the applied voltage, the flame length decreased and the tip of flame spreaded with increasing voltage. For the experimental conditions selected, the flame was blown off toward the ground electrode by corona ionic wind. When the negative applied voltage was greater than 3kV(for electrode spacing = 3.5cm), soot particles in inception or growth region were affected by the corona discharge, resulting in the reduction of number concentration. The results show that the ionic wind favored soot oxidation and increased flame temperature. Number concentration and primary particle size greatly increased, when the corona electrodes were located the region of soot nucleation or growth(close to burner mouth).

공기중 코로나방전의 초음파신호 특성 (Ultrasonic Signal Characteristics of Corona Discharges in Air)

  • 이상우;김인식;이광식;이동인;이동헌;배상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1702-1704
    • /
    • 1998
  • In order to establish the usefulness of ultrasonic techniques for detecting corona discharges in high-voltage power apparatus, it is first necessary to determine the relationship between electrical and ultrasonic signals of corona discharges in air. In this paper, various characteristics of ultrasonic signal detection for point-to-plane corona discharges using a 200[kHz] ultrasonic sensor are examined. In regard to the attenuation and directivity of ultrasonic signals, the signals were inversely proportional to the distance between corona sources and ultrasonic receiving sensors, and half attenuation angles were approximately 7.0 degree. Ultrasonic signals of positive polarities were first obserbed at corona inception voltages. and the signals were increased with increasing the applied voltages.

  • PDF

$SF_6$ 개스 중에시 wire형 도전성 입자가 절연파괴전압에 미치는 영향 (The Effect of Wire-shaped Conducting Particles on the Breakdown Voltage in Compressed $SF_6$)

  • 이동인;이형호;최병주;김영배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.258-262
    • /
    • 1988
  • Investigations were made on the effects of wire-shaped conducting particles in compressed gas chamber on breakdown voltage. The objective was to recognize the relationship between the length of wire-shaped conducting particles and a.c breakdown voltage. Also the influence of conducting particles on corona inception voltage and extinction voltage were investigated. The values of breakdown voltage and corona inception, extinction voltages were calculated by wire shaped-conducting particles lengths.

  • PDF

폴리머 애자의 End-fitting 설계 및 성능 평가기술 (End-fitting Design and Performance Evaluation of Polymer Insulator)

  • 조한구;이운용;한세원;한동희;지원영;여학규;강두원;천종욱;이형규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.25-29
    • /
    • 2004
  • Corona on polymer materials causes deterioration by the combined action of the discharge striking the surface and the action of certain chemical compounds that are formed by the discharges. In the design and manufacture of polymer insulators must be sufficiently large to avoid corona discharges, otherwise a shielding or corona ring (grading ring) needs to be installed on the insulator. To conduct this purpose, many researchers have investigated end-fitting of polymer insulator by voltage distribution simulation and electrical test. Grading rings are used to improve the performance of the insulator in multiple ways. They can reduce corona and associated audible noise and radio influence and television interference. The factors determining the uses of a grading ring are line voltage, geometry and dimensions of end fittings, geometry and dimensions of line hardware, and environmental conditions. In this paper, electrical property of polymer insulator with end-fitting design have been investigated by electrical field analysis, various end-fitting design, tracking wheel test, corona inception voltage and extinction voltage. Electrical field analysis is conducted by FEM program and various end-fitting is designed through this result. Designed end-fittings are manufactured and their performance is conducted by electrical performance test.

  • PDF

연소화염에 의한 수평배치 공기갭의 섬락전압 특성 (Flashover Characteristics of the Horizontal Air Gaps Caused by Combustion Flames)

  • 김인식;김이국;김충년;지승욱;이상우;이광식
    • 조명전기설비학회논문지
    • /
    • 제16권1호
    • /
    • pp.27-34
    • /
    • 2002
  • 본 연구에서는 불평등 전계인 침대침 갭을 수평배치하였을 때, 고전압 전극 부근에 설치한 화염에 의한 교류 및 직류 섬락전압 특성을 조사하였다. 화염에 의해 섬락이 발생할 때, 코로나 개시전압과 섬락극성을 조사하기 위해 전압 및 전류파형을 측정하였으며, 인가전압의 상승에 따른 코로나풍과 쿨롱력에 의한 화염의 형상이 왜곡되고 요동되는 현상을 관찰하였다. 실험 결과, 화염이 전극의 중간위치에 있을 때 화염에 의한 교류 섬락전압은 화염이 없는 경우에 비해 평균 62.7[%] 저하된 것으로 나타났으며, 화염의 높이에 따른 섬락전압의 특성에서 화염의 높이 h=5, h=7 및 h=9[cm]인 경우 교류 섬락전압의 평균값은 화염이 없을 때에 비해 각각 34.2[%], 27.3[%] 및 21.4[%] 저하된 것으로 나타났다.

전기수력학적 미립화에서 액적 형성에 영향을 미치는 인자에 관한 실험적 연구 (A Study on Influence Factors on Drop Formation in Electrohydrodynamic Atomization)

  • 성기안;이창식
    • 한국분무공학회지
    • /
    • 제8권2호
    • /
    • pp.24-30
    • /
    • 2003
  • An experimental study was performed to investigate the influence factors of drop formation in electrohydrodynamic atomization. The mode of electrohydrodynamic atomization depended on the various factors such as the flow rate of the liquid, the inner diameter of the nozzle, the distance between the nozzle tip and the ground electrode, the shape of the ground electrode. and the applied high voltage. This work was performed to investigate the experimental analysis for the flow pattern visualization of droplets, and the relationship between voltage application and the behavior of liquid atomization. Uniform drops of different sizes can be obtained at the inception of the spindle mode by charging the flow rate and the electric field. The drop size also decreased when the flow rate was raised for the spindle mode. The whipping motion occurred beyond 7kV and before the corona started to take effect.

  • PDF

모의 GIS 결함에 따른 UHF 신호의 스펙트럼 분석 (Spectrum analysis of UHF Signals Generated by Defects in a Simulated GIS)

  • 전재근;곽희로;노영수;김두석;김경화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1797-1799
    • /
    • 2003
  • In this paper, we measured partial discharge inception voltage(PDIV) and frequency spectra of UHF signal under following three cases, (1) a corona discharge due to a non uniform electric field for needle-plate electrode (2) a surface discharge caused by particles attached to a spacer in GIS, (3) free movements of particle in GIS. As a result of the experiment, it was revealed that the PDIV of Case (3) is higher than PDIVs of Case (1) and Case (2). It was also seem that UHF signal frequency spectra of one case are different from those of the other cases.

  • PDF