• 제목/요약/키워드: Core Specimen

검색결과 314건 처리시간 0.027초

강봉댐퍼로 보강한 기존 저층 철근콘크리트 필로티 건물의 내진성능 (Seismic Performance of an Existing Low-Rise Reinforced Concrete Piloti Building Retrofitted by Steel Rod Damper)

  • 백은림;오상훈;이상호
    • 한국지진공학회논문집
    • /
    • 제18권5호
    • /
    • pp.241-251
    • /
    • 2014
  • In this study, shaking table test was carried out to evaluate the seismic behavior and performance of low-rise reinforced concrete (RC) piloti structures with and without retrofit. The specimens were designed considering the characteristics of existing building with pilotis such as natural period, distribution factor of strength and stiffness between columns and core wall on the first soft story. The test for the non-retrofit specimen showed that damage was concentrated on the stiffer member on the same floor as the core wall failed by shear fracture whereas columns experienced slight flexural cracks. Considering the failure mode of the non-retrofit specimen, the retrofit method using steel rod damper was presented for improving the seismic performance of piloti structures. The results of the test for retrofit specimen revealed that the retrofit method was effective for controlling the damage as the main RC structural members were not destroyed and most of input energy was dissipated by hysteretic behavior of the damper.

부산 해성 점토의 일축압축강도 특성 및 교란도에 관한 연구 (Unconfined Compression Strengh Characteristics and Degree of Disturbance of Busan Marine Clay)

  • 김병일;이승원;이승현;조성민
    • 한국방재학회 논문집
    • /
    • 제5권4호
    • /
    • pp.29-36
    • /
    • 2005
  • 본 연구는 부산 가덕도 부근 해성점토에 대하여 일축압축시험을 실시하여 일축압축강도, 최대강도에서의 변형률, 심도와의 관계를 비교 및 분석하였으며 시료에 포함되어 있는 불순물과 시료채취시 충진율이 흙의 일축압축강도와 교란도에 미치는 영향을 파악하였다. 시험결과 시료의 일축압축강도는 최대강도에서의 변형률이 증가함에 따라 감소하는 결과를 보였으며 채취 심도가 깊을수록, 시료채취시의 충진율이 좋을수록 증가하는 추세를 보였다. 특히 시료 충진율의 증가는 일축압축강도 증가를 가져왔고 시료의 등급 또한 높여주었다.

양생환경 및 수중펌프압송이 고강도 그라우트의 강도에 미치는 영향 (The Effects of Curing Environment and Submerged Pump Pressure on the Strength of High-Strength Grout)

  • 김범휘;손다솜;이종구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.191-192
    • /
    • 2023
  • In recent years, the use of high-strength grout has gained popularity in offshore wind power generation complexes for facility foundations and bridges. These marine wind farms require support for horizontal loads from wind and waves. To ensure the strength of the grout produced in environments similar to the actual placing site, this study investigated the curing of high-strength grout discharged through pump pressure in various environments, and examined the difference in strength according to different variables. Compressive strength measurements revealed that the core specimen collected from the bottom (3cm) and uppermost (50cm) of the specimen exhibited lower strength compared to other height specimens, while the core specimen obtained from the corner exhibited lower strength compared to the center. These findings suggest that the strength difference between the center and the corner is more pronounced when curing at low temperatures. This effect is greater than the strength reduction that typically occurs during low-temperature curing, and thus, necessitates careful attention in similar construction environments.

  • PDF

암석의 파괴인성 측정에서 나타나는 CB 시험편의 치수효과에 관하여 (The Size Effect in Measuring the Fracture Toughness of Rock using Chevron Bend Specimen)

  • 김재동;백승규
    • 터널과지하공간
    • /
    • 제2권2호
    • /
    • pp.251-264
    • /
    • 1992
  • In this study, the size effect in measuring the fracture toughness of rock was investigated using the ISRM Suggested Method for Fracture toughness using Chevron Bend Specimens. Total 58 specimens were prepared with 4 different diameters, 29, 42, 54, 68mm and center cut-chevron notch. In addition to this, to evaluated the effect of anisotropy of Jecheon granite, which is the sample for this study, core drilling direction was adjusted perpendicular(short transverse) and parallel(arrester) to the rift plane in the sample and the measured fracture toughness for each direction were compared. Important results obtained from this study are as follows. Level ll test condition is more adequate than l, because of low data scattering and precision and corrected fracture toughness of Jechoen granite measured and 2.2MPa{{{{ SQRT { m} }}}} for arrester direction with minimum initial crack length 0.7cm. From the relationship between core diameter and initial crack length presented in the ISRM testing method, the specimen diameter should be bigger than 47mm. The fracture toughnesses measured for arrester and short transverse directon show 10% difference. This is to the anisotropy of Jecheon granite possessing rift plane.

  • PDF

광섬유 TR-EFPI 센서를 이용한 GFRP 직교 적층판의 변형률 해석 (Strain Analysis in GFRP Cross-Ply Laminates Using TR-EFPI Optical Fiber Sensor)

  • 우성충;최낙삼;권일범
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.150-153
    • /
    • 2003
  • Longitudinal strains({$varepsilon}_x$) of the core and skin layers in glass fiber reinforced plastic(GFRP) cross-ply composite laminates have been studied using the embedded optical fiber sensor of totally-reflected extrinsic Fabry-Perot interferometer(TR-EFPI). Foil-type strain gauges bonded on both the upper and lower surfaces were used for the measurement of the surface strains. Both TR-EFPI sensor and strain gauge bonded on the specimen surface showed excellent agreement within -0.0086 ~ +0.0302% strain. It was shown that values of {$varepsilon}_x$ in the interior of the surface layer and the core layer measured by embedded TR-EFPI sensor was significantly higher than that of the specimen surface measured by strain gauges. The experimental results were ascertained with finite element analysis. Embedded TR-EFPI optical fiber sensor could measure accurately the internal strains which were different from the surface.

  • PDF

연구용 원자로 2호기 해체과정 전산모사 (3D Graphic Simulation on the Dismantling Process of the KRR-2)

  • 김성균;정운수;이근우;박진호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1199-1204
    • /
    • 2003
  • The 3D simulations of the shielding concrete and the Rotary Specimen Rack(RSR) in the Korea Research Reactor-1&2(KRR-1&2) were carried out in present work. Four main dismantling processes, which are the removal of the RSR, reactor core region, beam tube, and thermal column and activated concrete, were selected for the graphic simulation by the consideration of the activation, worker training, work difficulty and so on. On the basis of these, we constructed their 3D CAD models and then drawn and reviewed their dismantling processes. In this study, the 3D simulation results of the shielding concrete and the RSR among main components are also presented and discussed.

  • PDF

노후아파트 현장에서의 콘크리트 압축강도 추정 (Concrete Compressive Strength Prediction from Deteriorating Apartment Site)

  • 이규동;임홍철;임병호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.155-158
    • /
    • 2006
  • Deduction of compressive strength in concrete members is very important to decide stability of structures. In this study, we compare the compressive strength of concrete between nondestructive test done to the building which was to be demolished at residential reconstruction site and destructive test of core specimen from the site. The result is more reliable because ore can compare the measurement of nondestructive tell with the result from destructive test using drilled cores. Compressive strength of each material was calculated with the result of rebound number test. In addition, we performed ultrasonic test for another result of compressive strength. And we made a comparative study of compressive strength of concrete drawn from both nondestructive and destructive tests.

  • PDF

현장 타설용 콘크리트의 시공품질 검토를 위한 연구 (A Study on Construction Quality Inspection of Field use Concrete)

  • 김민석;강병훈;강태경;박선길;이종균;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.1057-1062
    • /
    • 2000
  • The purpose of this study is to practice the method which can estimate 28-days strength of concrete in advance. This method is made for reliant quality control. Based on existing experiment, concrete that flyash added and normal concrete are placed into wall structure, and it is examined the difference between experiment use concrete and field use concrete. The result of this study are as follows : 1) Core test specimen have 10% lower strength to standard curing specimen. 2) At 28-days accelerated strength by microwave, average 35% in normal concrete, average 23% in flyash added concrete. 3) At coefficient of determination between compressive strength and accelerated strength, 0.84 in normal concrete core, 0.86 in standard curing normal concrete, 0.86 in flyash added concrete, 0.90 in standard curing flyash added concrete.

첨가제에 따른 전력선 통신용 자심 재료의 전자기적 특성 및 발열거동 (The Electromagnetic and Thermal Properties of Magnetic Core Materials for the Power Line Communication as the function of Additives)

  • 오영우;이혜연;김현식;허정섭;민복기;김종령
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권2호
    • /
    • pp.61-66
    • /
    • 2003
  • The electromagnetic properties and thermal behavior of Mn-Zn ferrite cores used for the blocking filter in he Power Line Communication(PLC) application were investigated as the function of additives. The highest density and permeability of 4.98 g/㎤) and 8,221 respectively were obtained to the specimen with composition of MnO 24 mol%, ZnO 25 mol% and Fe$_2$O$_3$ 51 mol% added MnO$_3$ 400 ppm, SiO$_2$ 100 ppm and CaO 200 ppm since the uniform grains were organized and the microstructures were compacted through reduction of pores. The permeability was increased up to 13,904 as temperature of specimen increased to 11$0^{\circ}C$, however, it was decreased precipitously under 100 over 11$0^{\circ}C$. The exothermic behavior was observed in the frequency range from 1 kHz to 1 MHz that the maximum temperature of specimens became 102$^{\circ}C$ at 1 MHz. In the consequence, the Mn-Zn ferrite core developed by this research will maintain the stable electromagnetic properties since the temperature of ferrite core rose to 93$^{\circ}C$ in the range of 10 kHz to 450 kHz bandwidth qualified for PLC.

지르코니아 코어의 두께에 따른 분광광도계 투과율에 관한 연구 (A study on the transmittance due to thickness of zirconium core)

  • 정인호;박명자;김주원
    • 대한치과기공학회지
    • /
    • 제33권2호
    • /
    • pp.129-136
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the transmittance differences of zirconium core due to thickness within the visible light spectrum. Methods: 36 specimens were divided into 3 groups (0.6mm, 0.8mm, 1.0mm) which have each 12 specimens. The size of specimens was 10mm high and 10mm wide. The transmittance of specimens are measured by spectrophotometer Model Cary 500 that can measure infrared-ray, visible wave and ultraviolet-ray. Results: The results shows that there was no significant difference between specimen's thickness and transmittance. Conclusion: The individual's color perception is personal and there are numerous factors that influence on it. In general, human eye can perceive the color of thing only within visible light spectrum but in this experiment through spectrophotometer there was no big difference between specimen's thickness and transmittance. To sum up, The most important factors were a layed porcelain structure and its thickness rather than core thickness in the porcelain crown.