• Title/Summary/Keyword: Core Concrete

Search Result 785, Processing Time 0.027 seconds

Composite action in connection regions of concrete-filled steel tube columns

  • Johansson, Mathias
    • Steel and Composite Structures
    • /
    • v.3 no.1
    • /
    • pp.47-64
    • /
    • 2003
  • In a nonlinear finite element study on the mechanical behavior of simple beam connections to continuous concrete-filled steel tube columns, two principally different connection types were analyzed: one with plates attached to the outside of the tube wall, relying on shear transfer, and one with an extended plate inserted through the steel section to ensure bearing on the concrete core. The load was applied partly at the connection within the column length and partly at the top, representing the load from upper stories of a multistory building. The primary focus was on the increased demand for load transfer to ensure composite action when concrete with higher compressive strength is used. The results obtained from the analyses showed that the design bond strength derived from push tests is very conservative, mainly due to the high frictional shear resistance offered by pinching and contraction effects caused by connection rotation. However, with higher concrete strength the demand for load transfer increases, and is hard to fulfill for higher loads when connections are attached only to the steel section. Instead, the connection should penetrate into the concrete core to distribute load to the concrete by direct bearing.

Structural Behavior on Horizontal Connection for Hybrid Precast Concrete Panel (복합 프리캐스트 콘크리트 패널 수평접합부의 구조적 거동)

  • Lee, Sang-Sup;Park, Keum-Sung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.155-162
    • /
    • 2019
  • Hybrid precast concrete panel is a wall element that is able to quickly construct the core wall structure for moderate-rise modular buildings. Hybrid precast concrete panel has unique characteristics which is a pair of C-shaped steel beams combined at the top and bottom of a concrete wall, In this study, an improved anchorage detail for vertical rebar is proposed to ensure the lateral force resistance performance of hybrid precast concrete panel emulating monolithic concrete wall. Also, the structural performance of horizontal connection is investigated experimentally with the bolt spacing parameter. And the behavior of hybrid precast concrete panel with the improved detail is compared with the monolithic concrete wall tested in a previous study. Finally, the required thickness of C-shaped steel beam to eliminate or minimize the deformation in horizontal connection is calculated by prying action equation.

The Investigation of Deteriortion of Concrete Structures due to the De-icing Salts (융빙제 사용으로 인해 열화된 콘크리트 구조물의 내구성 조사)

  • 문한영;김성수;류재석;김홍삼
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.77-82
    • /
    • 1996
  • The study was performed for the purpose of obtaining the fundamental data to improve the durability of concrete structures due to de-icing salts. To assume the degree of concrete deterioration, soluble chloride content in concrete, the depth of carbonation and compressive strength of core specimens were measured. The porgress of corrosion of concrete bridge was electrochemically monitored. The results show that the concrete structure was deteriorated and reinforced steel in concrete was corroded due to de-icing salts.

  • PDF

Field Application of Rapid Neutralization Assessment Method Using Core Drilling in Concrete Structures (코어드릴링에 의한 중성화 신속평가 방법을 이용한 콘크리트 구조물의 중성화 현장 적용성 평가)

  • Lim, Gun-Su;Lee, Hyeon-Jik;Beak, Sung-Jin;Lee, Hyuk-Ju;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.15-16
    • /
    • 2023
  • In this paper, we aimed to develop a new method for diagnosing the depth of neutralization in architectural and civil engineering structures using the core drilling method, which combines the speed of drilling with the accuracy of core ringing. When compared to the drilling method, the core drilling method showed a lower measurement deviation of 1-2mm (7.6%) in confirming the depth of neutralization. This is believed to be a result of potential interference during the sample collection process in the drilling method, where the drill may pass through aggregates, leading to overestimation, as indicated in previous studies. The rapid evaluation of neutralization using the core drilling method serves as an alternative to address the issues associated with both drilling and core ringing methods in diagnosing the depth of neutralization. It offers a solution to the inaccuracy caused by coarse aggregates and the cumbersome post-processing steps required for neutralization diagnosis. Our proposed technique aims to provide an accurate and expedited diagnosis of neutralization depth without the need for additional processes.

  • PDF

A Study on the Quality of Concrete Place under Raining Condition (우기중에 타설된 콘크리트의 품질 특성에 관한 연구)

  • 권영웅;정성철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.729-736
    • /
    • 1997
  • This paper gives the information of field concrete placed under raining condition. Experimental factors in this study are concrete strength, standard deviation and coefficient of variation. The results are as follows: 1. The strength of field concrete placed under raining condition is not largely dependent on the raining condition. 2. But, the quality of concrete is very critical.

  • PDF

An Constructive Experiment through Mock-up and Monolith of High-Strength High-Performance Concrete (고강도-고성능 콘크리트의 모의 부재 및 실대 구조물 시공 실험)

  • 김태영;이영호;정헌수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.357-364
    • /
    • 1997
  • In this experiment high-strength concrete of good workability is made by means of either replacing unit cement quantity to fly-ash by 20% or using low heat cement to reduce the internal hydration heat suggested as the fault of concrete. Concrete is poured through ready mixed concrete to test the ability of applying to the substantial works and is carried out the test of flowing and core strength and record of temperature of imitating specimens. It is capable to apply high-strength concrete replaced to fly-adh 20% to the substantial works through the experiment

  • PDF

A Study on the Scalability of Multi-core-PC Cluster for Seismic Design of Reinforced-Concrete Structures based on Genetic Algorithm (유전알고리즘 기반 콘크리트 구조물의 최적화 설계를 위한 멀티코어 퍼스널 컴퓨터 클러스터의 확장 가능성 연구)

  • Park, Keunhyoung;Choi, Se Woon;Kim, Yousok;Park, Hyo Seon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.4
    • /
    • pp.275-281
    • /
    • 2013
  • In this paper, determination of the scalability of the cluster composed common personal computer was performed when optimization of reinforced concrete structure using genetic algorithm. The goal of this research is watching the potential of multi-core-PC cluster for optimization of seismic design of reinforced-concrete structures. By increasing the number of core-processer of cluster, decreasing of computation time per each generation of genetic algorithm was observed. After classifying the components in singular personal computer, the estimation of the expected bottle-neck phenomenon and comparison with wall-clock time and Amdahl's law equation was performed. So we could obseved the scalability of the cluster appear complex tendency. For separating the bottle-neck phenomenon of physical and algorithm, the different size of population was selected for genetic algorithm cases. When using 64 core-processor, the efficiency of cluster is low as 31.2% compared with Amdahl's law efficiency.

A Review of the Physical Performance of Lightweight Aerated Concrete for Use as an Interior Core Material in Fire Doors (방화문 내부 심재로 적용하기 위한 경량기포콘크리트의 물리적 성능 검토)

  • Hong, Sang-Hun;Kim, Bong-Joo;Jung, Ui-In;Kim, Hae-Nah;Park, Jun-Seo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.111-112
    • /
    • 2023
  • With the development of cities, the density of the population is continuously increasing as buildings become larger and more high-rise, but since the Haeundae residential complex fire in Busan in 2010, there has been a growing need to meet the fire protection performance of buildings as large-scale fires continue to occur every year. On the other hand, fire doors, which are one of the fire protection performance of buildings, have been judged unqualified in 82% of cases when fire doors constructed on the actual site were inspected after completion. The reason for this is that paper honeycomb and glasswool, which are used as core materials for fire doors, absorb moisture, reducing thermal insulation performance, and sagging due to increased weight, leading to performance degradation due to warping in empty spaces. To overcome these problems, research is underway to apply lightweight aerated concrete, an inorganic material, as a core material. Therefore, in order to select a blowing agent that produces stable bubbles prior to the production of lightweight bubble concrete for application as a fire door inner core, this study examined the physical performance according to the type of blowing agent and dilution concentration, and the following conclusions were drawn. Compared to vegetable bubbles and independent bubbles, synthetic bubbles have 3~8% higher thermal conductivity than independent bubbles, but 3~6% lower slurry density than vegetable bubbles, and 2~13% higher compressive strength, which is thought to be an improvement of synthetic bubbles.

  • PDF

Analysis of rectangular hybrid steel-GFRP reinforced concrete beam columns

  • El-Heloua, Rafic G.;Aboutaha, Riyad S.
    • Computers and Concrete
    • /
    • v.16 no.2
    • /
    • pp.245-260
    • /
    • 2015
  • In this study, nominal moment-axial load interaction diagrams, moment-curvature relationships, and ductility of rectangular hybrid beam-column concrete sections are analyzed using the modified Hognestad concrete model. The hybrid columns are primarily reinforced with steel bars with additional Glass Fiber Reinforced Polymer (GFRP) control bars. Parameters investigated include amount, pattern, location, and material properties of concrete, steel, and GFRP. The study was implemented using a user defined comprehensive $MATLAB^{(R)}$ simulation model to find an efficient hybrid section design maximizing strength and ductility. Generating lower bond stresses than steel bars at the concrete interface, auxiliary GFRP bars minimize damage in the concrete core of beam-column sections. Their usage prevents excessive yielding of the core longitudinal bars during frequent moderate cyclic deformations, which leads to significant damage in the foundations of bridges or beam-column spliced sections where repair is difficult and expensive. Analytical results from this study shows that hybrid steel-GFRP composite concrete sections where GFRP is used as auxiliary bars show adequate ductility with a significant increase in strength. Results also compare different design parameters reaching a number of design recommendations for the proposed hybrid section.

Research on prefabricated concrete beam-column joint with high strength bolt-end plate

  • Shufeng, Li;Di, Zhao;Qingning, Li;Huajing, Zhao;Jiaolei, Zhang;Dawei, Yuan
    • Structural Engineering and Mechanics
    • /
    • v.74 no.3
    • /
    • pp.395-406
    • /
    • 2020
  • Many prefabricated concrete frame joints have been proposed, and most of them showed good seismic performance. However, there are still some limitations in the proposed fabricated joints. For example, for prefabricated prestressed concrete joints, prefabricated beams and prefabricated columns are assembled as a whole by the pre-stressed steel bar and steel strand in the beams, which brings some troubles to the construction, and the reinforcement in the core area of the joints is complex, and the mechanical mechanism is not clear. Based on the current research results, a new type of fabricated joint of prestressed concrete beams and confined concrete columns is proposed. To study the seismic performance of the joint, the quasi-static test is carried out. The test results show that the nodes exhibit good ductility and energy dissipation. According to the experimental fitting method and the "fixed point pointing" law, the resilience model of this kind of nodes is established, and compared with the experimental results, the two agree well, which can provides a certain reference for elasto-plastic seismic response analysis of this type of structure. Besides, based on the analysis of the factors affecting the shear capacity of the node core area, the formula of shear capacity of the core area of the node is proposed, and the theoretical values of the formula are consistent with the experimental value.