Minimization of Residual Stress of the Steel Cord for the Tire-reinforcement Using Finite Element Analysis (유한요소해석을 이용한 타이어 보강재용 스틸코드의 잔류응력 최소화)

  • Lee, Jong-Sup;Huh, Hoon;Lee, Jun-Wu;Lee, Byung-Ho
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.201-204
    • /
    • 2008
  • In this paper, several process parameter studies of the manufacturing process of the steel cords are carried out to verify the relation between the process parameters and the residual stresses on the steel cords. At first, the finite element analysis of the drawing process is performed and the residual stress distributions with respect to the wire material and the area reduction ratio are obtained. The residual stress of the drawn wire is imported the finite element analysis of the twisting process as an initial stress. After that a parameter study of the twisting process is carried out. The process parameters are the applied tension, the over-twisting angle and the tensile strength of the drawn wire. Based on these studies, the optimum values of the process parameters which can remove or reduce the undesired residual stresses are determined. The optimum value of the process parameters are confirmed by the finite element analysis of the elastic recovery process of the steel cords. Finally, the finite element analysis of the roller straightening process is done to study the variation of the distribution of the residual stress before and after the process.

  • PDF

Pedicle Morphometry for Thoracic Screw Fixation in Ethnic Koreans : Radiological Assessment Using Computed Tomographic Myelography

  • Choi, Yang-Soo;Kim, Young-Jin;Yi, Hyeong-Joong;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.317-321
    • /
    • 2009
  • Objective : In the thoracic spine, insertion of a pedicle screw is annoying due to small pedicle size and wide morphological variation between different levels of the spine and between individuals. The aim of our study was to analyze radiologic parameters of the pedicle morphometry from T1 to T8 using computed tomographic myelography (CTM) in Korean population. Methods : For evaluation of the thoracic pedicle morphometry, the authors prospectively analyzed a consecutive series of 26 patients with stable thoracic spines. With the consent of patients, thoracic CTM were performed, from T1 to T8. We calculated the transverse outer diameters and the transverse angles of the pedicle, distance from the cord to the inner cortical wall of the pedicle, and distance from the cord to the dura. Results : Transverse outer pedicle diameter was widest at T1 ($7.66{\pm}2.14\;mm$) and narrowest at T4 ($4.38{\pm}1.55\;mm$). Transverse pedicle angle was widest at T1 ($30.2{\pm}12.0^{\circ}$ and it became less than $9.0^{\circ}$ below T6 level. Theoretical safety zone of the medial perforation of the pedicle screw, namely, distance from the cord to inner cortical wall of the pedicle was more than 4.5 mm. Conclusion : Based on this study, we suggest that the current pedicle screw system is not always suitable for Korean patients. Computed tomography is required before performing a transpedicular screw fixation at the thoracic levels.

Finite Element Analysis of Air Springs with Fiber-Reinforced Rubber Composites Using 3-D Shell Elements (3차원 셸 요소를 이용한 섬유보강 고무모재 공기 스프링의 유한요소해석)

  • Lee, Hyoung-Wook;Huh, Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.4
    • /
    • pp.602-609
    • /
    • 2001
  • This paper is concerned with the orthotropic problem of diaphragm-type air springs which consist of rubber linings, nylon reinforced rubber composite and bead ring. The analysis is carried out with a finite element method developed to consider the orthotropic properties, geometric nonlinearity using four-node degenerated shell element with reduced integration. Physical stabilization scheme is used to control the zeroenergy mode of the element. The analysis includes an inflation analysis and a lateral analysis of an air spring for the deformed shape and the spring load with respect to the vertical and l ateral deflection. Numerical results demonstrate the variation of the outer diameter, the fold height, the vertical force and the lateral force with respect to the inflation pressure and the lateral deflection.

Performance Test and Finite Element Analysis of Pneumatic Muscle Actuator (공기압 근육 구동기의 유한요소 해석 및 성능시험)

  • Huh Shin;Bae Sang-Kyu;Kim Dong-Soo;Kim Wan-Doo;Hong Sung-In
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.6 s.249
    • /
    • pp.662-669
    • /
    • 2006
  • The pneumatic muscle actuator consists of an air bellows tube with two end-flanges. The air bellows tube is made from rubber layers and flexible sheathing formed from nylon 6 fibers. This structure can be stretched or compressed to convert the radial expansive forces into contractile forces. We performed the finite element analysis and the performance test of pneumatic muscle actuator. Also, the pneumatic muscle actuator was manufactured and tested by home-made tester. The results of FEA was similar with performance test below the maximum error of 42 %.

The Effect of Etching on Low-stress Mechanical Properties of Polypropylene Fabrics under Helium/Oxygen Atmospheric Pressure Plasma

  • Hwang, Yoon J.;An, Jae Sang;McCord, Marian G.;Park, Shin Woong;Kang, Bok Choon
    • Fibers and Polymers
    • /
    • v.4 no.4
    • /
    • pp.145-150
    • /
    • 2003
  • Polypropylene nonwoven fabrics were exposed to He/$O_2$ atmospheric pressure glow discharge plasma. Surface chemical analysis and contact angle measurement revealed the surface oxidation by formation of new functional groups after plasma treatment. Weight loss (%) measurement and scanning electron microscopy analysis showed a significant plasma etching effect. It was investigated in low-stress mechanical properties of the fabrics using Kawabata Evaluation System (KES-FB). The surface morphology change by plasma treatment increased surface friction due to an enhancement of fiber-to-fiber friction, resulting in change of other low-stress mechanical properties of fabric.

Circular Texture of Drawn High-Carbon Steel Wire for Tire Cord (타이어 코드용 고탄소강선의 원형집합조직)

  • 엄경근;안종규;정효태;이동녕
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.10a
    • /
    • pp.194-197
    • /
    • 1997
  • The texture of a 0.25mm dia high-carbon(0.73%) steel wire made by drawing the patented and brass coated 1.4mm wire through 22 dies with a die-angle of 12$^{\circ}$has been measured. The ideal fiber texture was obtained in the center layer, while the circular texture and the near fiber texture having {111}<110> and weak {112}<110> components were obtained in the intermediate and surface layers, respectively. The circular texture was approximated by {110}<110> plus {110}<114>. The texture could be predicted by the Taylor-Bishop-Hill theory coupled with FEM for deformation.

  • PDF

Identifications of Reflex Muscle Activities and Joint Moments Triggered by Electrical Stimulation to Sole of the Foot during Lokomat Treadmill Walking

  • Kim, Yong-Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.344-350
    • /
    • 2010
  • The aim of this study was to investigate the characteristics of the flexion withdrawal reflex modulated during Lokomat treadmill walking in people with spinal cord injury. The influence of the limb position and movement were tested in 5 subjects with chronic spinal cord injury. EMG activities from tibialis anterior and moments of the hip joint elicited by the foot stimulation were examined during Lokomat treadmill walking. To trigger the flexion withdrawal reflex during Lokomat treadmill walking, a train of 10 stimulus pulses was applied at the skin of the medial arch. The TA EMG activity was modulated during gait phase and the largest TA reflex was obtained after heel-off and initial swing phase. During swing phase, TA EMG was 40.9% greater for the extended hip position (phase 6), compared with flexed hip position (phase 8). The measured reflex moment of the hip joint was also modulated during gait phase. In order to characterize the neural contribution of flexion reflex at the hip joint, we compared estimated moments consisted of the static and dynamic components with measured moment of the hip joint. The mean static gains of reflex hip moments for swing and stance phase are -0.1, -0.8, respectively. The mean dynamic gains of reflex hip moments are 0.25 for swing, 0.75 for stance phase. From this study, we postulate that the joint moment and muscle response of flexion withdrawal reflex have the phase-dependent modulation and linear relationship with hip angle and angular velocity for swing phase during Lokomat treadmill walking.

The Effect of EA and TENS on GAP-43 Expression in Spinal Cord after Rat Sciatic Nerve Crush Injury (전침자극과 경피신경전기자극이 흰쥐 좌골신경 압좌손상 후 척수내 GAP-43 발현에 미치는 영향)

  • Lee, Hyun-Min;Park, Eun-Se;Kim, Min-Hee;Kim, Souk-Boum;Kim, Dong-Hyun;Kim, Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.1
    • /
    • pp.65-73
    • /
    • 2006
  • Purpose: The purpose of this study was to identify the effect of electroacupuncture(EA) and transcutaneous electric nerve stimulation(TENS) after sciatic nerve crush injury in rats. Methods: The EA for experimental group I (Exp I, n=15) and TENS for experimental group II (Exp II, n=15) was applied from post-injury day(PD) 1 to PD 14 after sciatic nerve injury using low frequency stimulator that gave electrical stimulation(15min/60Hz). In order observe the effect of EA and TENS, this study examined GAP-43 expression in rat lumbar spinal cord at the PD 1, PD 7 and PD 14. In addition, the stride length(SL) and toe out angle(TOA) were measured at the PD 7 and PD 4. Results; Exp I and Exp II had higher GAP-43 immunoreactivity than control group(PD 1, 7, 14). The SL of Exp I and Exp II were significantly higher than control group(PD 7, 14). The TOA of Exp I and Exp II were significantly lower than control group(PD 7, 14). Conclusion: EA and TENS application increased motor nerve recovery and expression of GAP-43 immunoreactivity after sciatic nerve crush injury. Therefore effect of TENS and EA had similar effect on nerve regeneration and functional recovery.

  • PDF

Utility Evaluation of Split VMAT Treatment Planning for Nasopharyngeal cancer (비인두암 Split VMAT 치료계획 유용성 평가)

  • Tae Yang Park;Jin Man Kim;Dong Yeol Kwon;Jun Taek Lim;Jong Sik Kim
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.13-20
    • /
    • 2022
  • Purpose : IMRT using Tomotherapy during nasopharyngeal cancer radiation therapy irradiate an accurate dose to tumor tissues and is effective to reduce a dose rapidly in normal tissues. However, this has high MU and long Beam On Time. This study aims to analyze differences in tumors, normal tissues and low-dose distributions and the efficiency of Split VMAT after applying Helical IMRT (Tomotherapy), VMAT (Linac : 2Arc) and Split VMAT (Linac : 4Arc) plans. Materials and Methods : This study targeted ten nasopharyngeal cancer patients of this hospital and compared three treatment plans (Helical IMRT, VMAT, Split VMAT). For Helical IMRT planning, Precision® (Version 1.1.1.1, Accuray, USA) was used, and for VMAT and Split VMAT planning, Pinnacle (Version 9.10, Philips, USA) was used. The total dose applied was 38.4 Gy / 32 Gy (Daily Dose 2.4 Gy (GTV + 0.3 cm) / 2 Gy (CTV + 0.3 cm) 16Fx), and for GTV + 0.3 cm (P_GTV), 95% of V38.4Gy was prescribed. VMAT with an angle of 360° 2Arc was applied, and for Split VMAT, the field was divided into the right, the left, the top and the bottom and an angle of 360° 4Arc, 6MV was set. For evaluating the quality of the treatment plans, differences in tumors, normal tissues and low-dose area were compared, and Beam On Time was measured to analyze the efficiency. Results : When calculating the mean values of evaluation items of the three treatment plans (Helical IMRT, VMAT, Split VMAT) for the patients, the H.I (Homogeneity Index) of P_GTV was 1.04, 1.11 and 1.1 respectively, and the C.I (Confomity Index) of P_CTV was 1.03, 0.99 and 1.00 respectively. The mean dose of RT Parotid Gland (Gy) was 14.54, 17.06 and 14.76 respectively, the mean dose of LT Parotid Gland (Gy) was 14.32, 17.32 and 15.09 respectively, the maximum dose of P_Cord (Spinal Cord + 0.3 cm) (Gy) was 20.57, 22.59 and 21.06 respectively, and the maximum dose of Brain Stem (Gy) was 22.35, 23.99 and 21.68 respectively. The 50% isodose curve (cc) was 1332, 1132.5 and 1065.2 respectively. Beam On Time (sec) was 373.7, 130.7 and 254.4 respectively. Conclusion : Displaying a similar treatment plan quality to Helical IMRT, which is used a lot for head and neck treatment, Split VMAT reduced the low-dose area and Beam On Time and produced a better result than VMAT. Therefore, it is considered that Split VMAT is effective not only for nasopharyngeal cancer but also for other head and neck cancers.

AN ACOUSTIC ANALYSIS OF PRONUNCIATION IN CHILDREN WITH ANGLE'S CLASS II DIV. 1 MALOCCLUSION (Angle씨 II급 1류 부정교합아동의 발음에 관한 음향학적 연구)

  • Park, Yun-Chung;Lee, Sang-Hoon;Shon, Dong-Su
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.95-111
    • /
    • 1997
  • The human speech organ consists of respiration system (lung, larynx), phonation system (vocal cord), articulation system (esophagus, pharynx, uvula, teeth, gingiva, palate, tongue, lip) and resonating system(oral cavity, nasal cavity, paranasal sinus). Because teeth are components of the articulation system, it has been reported that the persons with abnormally positioned teeth generally have abnormal occlusion and pronunciation. In this study, using /ㅅ(s)/, the most commonly mispronunced consonant in children with malocclusion, and the seven single vowels, /사(sa), 서($s\delta$), 소(so), 수(su), 스($s\omega$), 시(si), 세(se)/ and / ㅏ(a), ㅓ($\delta$), ㅗ(o), ㅜ(u), ㅡ($\omega$), 1(i), ㅔ(e)/ were recorded and analyzed using speech analysis program on computer by measuring formants and compared them for investigating the differences in pronunciation in children with Angle's class I occlusions and those with Angle's class II div.1 malocclusion. The result were as follows: 1. In the Angle's Class II div.1 group, there were no significant differences in F1 of all recorded sounds as compared with Angle's Class I group(p>0.05). 2. In the consonants, there were significant differences in F2 of /스($s\omega$)/ and F2/F1 ratio of /사(sa), 서($s\delta$), 시(si)/ between the two group(p<0.05). 3. In the vowels, there were significant differences F2/F1 ratio of /ㅓ($\delta$)/(p<0.05) and no significant differences in F2/F1 ratio between two group(p>0.05). 4. In the consonants, there were significant differences in F2 and F2/F1 ratio when succeeding vowels were high or low, and F2/F1 ratio when front in accordance with tongue position (p<0.05). 5. In the vowels, there were no significant differences in formant in accordance with tongue position(p>0.05)

  • PDF