• Title/Summary/Keyword: Copper grid

Search Result 44, Processing Time 0.024 seconds

Effects of Rectifier and Copper Grid Interference on the Detection Reliability of Coating Flaws on Buried Pipes (매설 배관 피복 결함 탐상 정확도에 미치는 인접 정류기 및 접지 구리망 간섭의 영향)

  • Kim, M.G.;Lim, B.T.;Kim, K.T.;Chang, H.Y.;Park, H.B.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.211-223
    • /
    • 2020
  • The external corrosion of buried piping can be controlled using both coating and cathodic protection. Several factors are involved in the damage and deterioration of the coating on pipes. There are many detection methods for coating defects on pipes and the direct current voltage gradient (DCVG) method is one of the most powerful methods. However, the detection reliability of DCVG can be affected by interferences such as stray current, metal objects connected to rectifiers, and copper grids. Therefore, this study focused on the interference effects of rectifiers and a copper grid on the reliability of coating flaw detection. As the length of the interference pipe connected to the rectifier increased, the reliability decreased. In contrast, as the distance between the pipe and the copper grid increased, the reliability of the coating flaw detection increased. The detection results produced by the DCVG method were discussed using current and potential simulations for a pipe with a rectifier and copper grid interference in the soil.

Development of the Copper Core Balls Electroplated with the Solder of Sn-Ag-Cu

  • Imae, Shinya;Sugitani, Yuji;Nishida, Motonori;kajita, Osamu;Takeuchi, Takao
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1207-1208
    • /
    • 2006
  • We developed the copper core ball electroplated with Sn-Ag-Cu of the eutectic composition which used mostly as Pb free solder ball with high reliability. In order to search for the practicality of this developed copper core ball, the evaluation was executed by measuring the initial joint strength of the sample mounted on the substrate and reflowed and by measuring the joint strength of the sample after the high temperature leaving test and the constant temperature and the humidity leaving test. This evaluation was compered with those of the usual other copper core balls electroplated with (Sn,Sn-Ag,Sn-Cu,Sn-Bi) and the Sn-Ag-Cu solder ball.

  • PDF

Effects of electrode configurations on uniformity of copper films on flexible polymer substrate prepared by ECR-MOCVD (ECR-MOCVD에 의해 연성 고분자 기판에 제조된 구리막의 균일도에 전극의 형태가 미치는 영향)

  • 전법주;이중기
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.34-46
    • /
    • 2004
  • Copper films were prepared by using ECR-MOCVD(Electron Cyclotron Resonance Metal Organic Chemical Vapor Deposition) coupled with a DC bias system. The DC bias is connected to the electrode which placed 1∼3cm above the polymer substrate. The pulse electrical field around the electrode attracts the positive charged copper ions generated from the dissociation of copper precursor, $Cu(hfac)_2$, under ECR plasma. Condensation of supersaturated copper ions in the space between the electrode and substrate, makes it possible to deposit copper film on the polymer substrate even at room temperature. In this study, optimization of the electrode configuration was carried out in order to obtain the uniform films. The uniformity of the deposited films were closely related to the parameters of electrode geometry such as electrode shape, thickness, grid size and the spacing between electrodes. The most uniform copper film was observed with the electrode that enabled uniform electrical field distribution across the whole dimension of electrode.

Ag Grid를 이용한 플렉시블 투명 전극의 투명 안테나 특성 연구

  • Jo, Chung-Gi;Kim, Han-Gi
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.27.2-27.2
    • /
    • 2011
  • 본 연구에서는 저저항/고투과 플렉시블 투명 전극 개발을 위해 금속 그리드가 적용된 투명 전극을 개발하였다. Lift off 공정을 도입하여 플렉시블 PET 기판 위에 Ag grid를 성막하고 이후 연속 공정이 가능한 Roll-to-Roll sputtering system을 이용하여 최적화된 ITO(40nm)/Ag(12nm)/ITO(40nm) 다층 투명 전극을 성막하였다. 제작된 플렉시블 투명 전극의 전기적, 광학적, 구조적 특성 및 기계적/전기적 안정성 평가를 위해 four-point probe measurement, Hall effect measurement, UV/Vis spectrometer, scanning electron microscopy 및 bending tester를 이용하여 각각의 특성을 분석하였다. Ag grid가 적용된 ITO/Ag/ITO 투명 전극에서 Ag의 배선 간격이 0.75 mm일 때 0.18 ohm/sq. 의 낮은 면 저항과 가시광선 영역에서 80% 이상의 높은 투과율을 나타내었으며, 이러한 저저항 및 고투과율 특성으로 인해 최적화된 배선 간격 0.75 mm에서 $538.11{\times}10^{-3}\;ohm^{-1}$의 매우 높은 figure of merit ($T^{10}/R_{sh}$) 값을 확보할 수 있었다. 기계적 응력에 따른 전기적 안정성 특성 분석 결과 5,000회 이상의 bending cycle 에서도 초기 저항 값과 유사한 전기적 특성을 나타냄으로써 Ag grid가 적용된 ITO/Ag/ITO 플렉시블 투명 전극의 기계적 응력에 따른 전기적 안정성을 확인할 수 있었다. Ag grid가 적용된 ITO/Ag/ITO 투명 전극의 투명 안테나 적용 가능성을 타진하기 위해 low band 및 high band 영역에서의 안테나 효율을 측정하였으며, 모든 영역에서 상용화된 copper 안테나와 유사한 효율을 나타내었다. Ag grid를 이용한 플렉시블 투명 전극의 저저항/고투과율 특성은 플렉시블 광전소자의 투명 안테나로의 적용 가능성을 나타낸다.

  • PDF

Efficiency of Vitrification using Conventional Straw and Grid as a Vihicle in Mouse Oocytes (마우스 성숙난자의 Straw와 Grid를 이용한 유리화동결법의 효율성 검토)

  • 정형민;박이석;박성은
    • Journal of Embryo Transfer
    • /
    • v.16 no.3
    • /
    • pp.233-237
    • /
    • 2001
  • To develop an effective vitrification method, we examined the use of a conventional straw as vessel fur vitrification of mouse oocytes, and to compare the post-thaw survival and chromosome configuration of these oocytes with those vitrified in grids. Intact cumulus-enclosed oocytes were vitrified with DPBS with 5.5 M ethylene glycol and 1.0 M sucrose, and loaded into straws and onto eletron microscopic copper grid fur storing in liquid nitrogen. Intact vitrified and thawed oocytes were karyotying for chromosome. The rates of post-thawed survival were 88.5% in vitrified oocytes with straws, and 83% in vitrified ooctyes with grids. Vitrified and thawed oocytes with straws and grids were increased chromosomal abnormality (31.4% and 30.9%) compared with fresh oocytes (17.8%). The conventional straws can be used as vessel for vitrification to prevent of inflection in liquid nitrogen.

  • PDF

Copper Oxide Spike Grids for Enhanced Solution Transfer in Cryogenic Electron Microscopy

  • Dukwon Lee;Hansol, Lee;Jinwook Lee;Soung-Hun Roh;Nam-Chul Ha
    • Molecules and Cells
    • /
    • v.46 no.9
    • /
    • pp.538-544
    • /
    • 2023
  • The formation of uniform vitreous ice is a crucial step in the preparation of samples for cryogenic electron microscopy (cryo-EM). Despite the rapid technological progress in EM, controlling the thickness of vitreous ice on sample grids with reproducibility remains a major obstacle to obtaining high-quality data in cryo-EM imaging. The commonly employed classical blotting process faces the problem of excess water that cannot be absorbed by the filter paper, resulting in the formation of thick and heterogeneous ice. In this study, we propose a novel approach that combines the recently developed nanowire self-wicking technique with the classical blotting method to effectively control the thickness and homogeneity of vitrified ice. With simple procedures, we generated a copper oxide spike (COS) grid by inducing COSs on commercially available copper grids, which can effectively remove excess water during the blotting procedure without damaging the holey carbon membrane. The ice thickness could be controlled with good reproducibility compared to non-oxidized grids. Incorporated into other EM techniques, our new modification method is an effective option for obtaining high-quality data during cryo-EM imaging.

Open Pulled Straws, EM Grid, Nylon Loop법에 의한 돼지성숙난자의 유리화동결 비교

  • 안미현;김인덕;석호봉
    • Proceedings of the KSAR Conference
    • /
    • 2003.06a
    • /
    • pp.83-83
    • /
    • 2003
  • 돼지 난자의 유리화 동결 처리 방법 중 난자를 담는 용기(loading vessel)의 재료로 최근에 알려진 것으로 open-pulled straws(OPS)[Vajta등, Mol Reprod Dev, 51:53-58, (1998)], electron microscope grids(EMG) [Martino등,Biol Reprod, 54:1059-1069, (1996)〕, nylon loop system(NLS) [Lane등, Fertil Steril,72: 1073-1078, (1999)] 등이 보고되고 있다. OPS는 1/4cc straws를 열을 가하여 길게 뽑아 내벽을 얇게 함으로써 filing된 난자나 수정란이 액체 질소와 접촉했을 때 유리화가 신속하게 되도록 하는 방법으로 돼지에서는 별로 보고된 것이 없다. EMG는 열전도가 예민한 전자현미경용 copper grid를 이용한 방법으로 최근 국내 기술진의 연구성적을 포함한 몇몇 학자들에 의하여 보고되었고 NLS는 0.5mm직경의 nylon loop를 이용하여 급속 동결한 성적이 보고되었으나, 돼지 난자에 응용 된 것은 없다. 따라서 이와 같은 동결 재료는 사람과 반추류, mouse외에 돼지 난자에 대하여는 전혀 시도되지 않았지만 유리화 동결기술에서 가장 중요한 실험으로 생각된다. 성공적인 유리화 동결을 위해서는 수정란이 냉각의 전도성이 빠르고, 작은 용액을 수정란과 같이 filling해야 하며 모든 동작이 신속 간편해야 하며 융해 방법도 초급속도의 융해가 요구되므로 이에 부합되어야 한다. 연구 목적은 돼지 난자를 유리화 동결/융해 시 동결 재료-straw/glass, copper grid, nylon 3가지에 대한 제작 방법, 난자 loading, 동결 처리, 보관 방법, 융해 방법 등을 난자의 회수, 수정 후 생존율을 비교 조사하여 가장 우수한 방법을 선택할 목적이었다. 수행 내용은 3가지의 재료의 sample을 제작하고 소독한 다음 준비된 돼지 COCs을 40시간동안 IVM한 후 난자를 5~l5개 정도로 선정 하여 준비된 VS 용액에 평형처리 하였다. 각 재료의 용기에 loading 한 후 동결/보관하였고, 융해는 역순으로 평형하여 maturation 배지에 3~4시간 배양한 다음 경검하고 IVF한 후 NCSU-23 배지에 담아 IVC 배양하면서 cell cleavage상태를 확인하였다.

  • PDF

Growth and analysis of Copper oxide nanowire

  • Park, Yeon-Woong;Seong, Nak-Jin;Jung, Hyun-June;Chanda, Anupama;Yoon, Soon-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.245-245
    • /
    • 2009
  • l-D nanostructured materials have much more attention because of their outstanding properties and wide applicability in device fabrication. Copper oxide(CuO) has been realized as a p-type metal oxide semiconductor with narrow band gap of 1.2 -1.5eV. Copper oxide nanostructures can be synthesized by various growth method such as oxidation reaction, thermal evaporation thermal decomposition, sol-gel. and Mostly CuO nanowire prepared on the Cu substrate such as Copper foil, grid, plate. In this study, CuO NWs were grown by thermal oxidation (at various temperatures in air (1 atm)) of Cu metal deposited on CuO (20nm)/$SiO_2$(250nm)/Si. A 20nm-thick CuO layer was used as an adhesion layer between Cu metal and $SiO_2$

  • PDF

A Two-dimensional Grid of Copper (I) Coordination Polymer: Preparation and Structure of Bromo(pyrazine)copper(I), [CuBr(pyz)] (2차원 격자 형태의 구리 배위 고분자: Bromo(pyrazine)copper(I), [CuBr(pyz)]의 합성 및 구조)

  • Baeg, Jee-Young;Kim, Han-Na;Lee, Yeon-Kyoung
    • Korean Journal of Crystallography
    • /
    • v.15 no.1
    • /
    • pp.5-8
    • /
    • 2004
  • The hydrothermal reaction of copper(I) bromide (CuBr) and pyrazine ($C_4H_4N_2$, pyz) gave a 2-D corrdination polymer [CuBr(pyz)] (1). X-ray structure determination revealed that polymer 1 has a 2-D network based on rectangular grids, each of which has the dimensions of 4.0${\times}$5.7 ${\AA}$. Polymer 1 has channels along the b-axis.

Experimental measurements on Single-Phase Local heat transfer coefficients in $6{\times}6$ rod bundles with LSVF mixing vanes (LSVF 혼합날개를 이용한 $6{\times}6$ 연료봉 다발에서의 단상 국부적 열전달계수의 실험적 측정)

  • Bae, Kyenug-Keun;Choi, Young-Don
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.300-305
    • /
    • 2005
  • The present experimental study investigates single-phase heat transfer coefficients downstream of support grid in $6{\times}6$ rod bundles. Support grid with split mixing vanes enhance heat transfer in rod bundles by generating it make turbulence. But this turbulence is confined to short distance. Support grid with LSVF mixing vanes enhanced heat transfer to longer distance. The corresponding Reynolds number investigated in the present study is Re=30,000. The heat transfer coefficients are measured using heated and unheated copper sensor.

  • PDF